Global Ambulatory Infusion Product Catalogue

2y ago
75 Views
8 Downloads
3.40 MB
27 Pages
Last View : 26d ago
Last Download : 2m ago
Upload by : Amalia Wilborn
Transcription

Global Ambulatory InfusionProduct CatalogueFor home, pain managementand oncology treatments

23Who are BD?BD is a global medical technology company that isadvancing the world of health by improving medical discovery,diagnostics and the delivery of care. BD is leading in patientand healthcare worker safety and the technologies thatenable medical research and clinical laboratories. We provideinnovative solutions that help advance medical research andgenomics, enhance the diagnosis of infectious disease andcancer, improve medication management, promote infectionprevention, equip surgical and interventional procedures andsupport the management of diabetes. BD offers infusion andintravenous (IV) therapy systems, solutions and devicesincluding pumps, software, interoperability, IV setsand accessories.and are able to offer the highest levels of quality whenservicing or repairing your devices.There for you - service and supportOur commitment to youOur team of skilled, dedicated and passionate clinicians andtechnicians support both healthcare workers and patientsusing our devices.Patient SafetyTechnical SupportOur field-based technical service team is the center ofexcellence for the repair, service and calibration of yourdevices. Our qualified engineers have a completeunderstanding of the device, down to component level,Clinical Support and EducationTo ensure our products are safe and easy to use for patientsand clinicians, our team of trained professionals offer deviceuser training. To support the provision of safe and efficientcare in hospital, in the community or at home, our dedicated,knowledgeable and attentive customer support team iscommitted to getting it right, on time, first time, every time.Whether you are a clinician, an engineer or a patient usingour products or services, our team of experienced customersupport professionals are available to deal with your enquiry.At BD, we are committed to patient and medicationsafety. We understand that each and every healthcareprovider is unique and we have the knowledge, insight,skills and experience to support our customers withimproving patient safety.

Table of contents45BD BodyGuard infusion pumps6BD BodyGuard 8BD BodyGuard Duo10BD BodyGuard Pain Manager12BD BodyGuard Epidural14BD BodyGuard T16BD BodyGuard MicroSets17Extension Sets for Syringe pumps18General Admin Sets20TPN Infusion Sets22PCA Infusion Sets25Transport Set26Regional Anaesthesia and Epidural Infusion Sets28Regional Anaesthesia and Epidural Infusion Sets with NRFit connection30Oncology Infusion Sets34Accessories35Pouch/Bag40Lockbox42Chargers and batteries44Power cord and cables46Bolus cable47Miscellaneous5Pumps

BD BodyGuard6 7BD BodyGuard infusion pump specificationsOrder Codes†Multi-therapy solutionsThe BD BodyGuard infusion pump is a small, lightweightambulatory infusion pump which offers flexibility and reliability.Effortless transition between hospital and home care requirementsis the core of the BD BodyGuard infusion pump.ContinuousTotal parenteralnutrition (TPN)25 dosesPatient-controlledanalgesia (PCA)IntermittentDrug librariesDimensions and weightProtocols libraryWeight (with standard battery) 410 gPump only (H/W/D) 112 x 89 x 40 mmFully programmable drug library, with automatic calculationof drug concentration programmable via PC withBodyComm software**Wide flow rate rangeUp to 128 drugs referred to as protocols0.1 - 1200 ml/h2000 user events logPiggyback (Secondary) 0.1 - 1200 ml/hPower supplyBolus 0 - 1200 ml/h110-240 VAC, 50/60 Hz. 0.3A maxKVO Rate 0 (OFF) - 20 ml/hrBattery specificationsFlow rate accuracy* 5 %Rechargeable Li-Polymer 7.4 V BatteryVolume to be infused1800 mAh.0.1 - 9999 mlRate (mL/h)Approx. Battery life (hours)Patient safety25 & 1251512008LanguageProduct CodeUltrasonic Air Sensor Air bubble size 0.04 – 2 mlEnglish999-603BDENOcclusion Pressure 100-1500 mmHg (10 mmHg 03RUTurkish999-603TUGreek999-603GRProgrammable infusion time (Dose over time)100 hrsComplies with the current version of the following standardsIEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8,IEC 60601-1-11, IEC 60601-1-12, IEC 60601-2-243600 mAh. Life at 125 ml/h (optional) up to 30 hPump alarms/alertsAir in line / Up Occlusion, Down Occlusion, Near End Program,End Program / End of Infusion, Low Battery, End Battery, PumpUnattended, Door Open, System Error, Missing Set Key, with the useof flow sensor accessoryPorts1 x RJ45 – for drop sensor1 x RS232 (Male) – for PC communicationAdditional specificationsInsulation class II, type CFIngress Protection: IP33Linear Peristaltic mechanism* Achieved under nominal conditions** Only trained CME or BD associates or authorized representatives are allowed to configure BD BodyGuard infusion and syringe pumps and upload the clinician-approved protocolsto supported pumps.† Each order code contains several languages in addition to the primary language. Check with your local representative on product availability.

BD BodyGuard Duo 89BD BodyGuard Duo infusion pump specificationsDimensions and weightNumber of channelsWeight (with standard battery) 450g2 (independent)Weight (with battery and standard pole mount charger) 600gPump only (H/W/D) 150x 90 x 45mmWide flow rate range0.1 - 1200 ml/hPiggyback (Secondary) 0.1 - 1200 ml/hBolus 0 - 1200 ml/hOptimized drug delivery through simple workflow,safety, and reduced medication leftover.With 2 infusion channels, a single simplified user interface,and true concurrent flow capability, the BD BodyGuard Duoinfusion system addresses the needs of high intensity multi-channelinfusion environments such as out-patient medical oncology, patienttransport, and general infusion therapy. The BD BodyGuard Duo andBD BodyGuard MicroSet systems offer flexibility and convenience toboth healthcare worker and patient by helping free up nurse time,helping ensure adherence to medication protocols, improving workflowefficiency, and helping reduce equipment cost and footprint.Order Codes†KVO Rate 0 (OFF) - 20 ml/hrFlow rate accuracy* 5 %Power supply110-240 VAC, 50/60 Hz. 0.3A maxBattery specificationsRechargeable Li-Polymer 7.4VEnglish999-903EN0.1 - 9999 mlBattery 1800 mAhSpanish999-903ESTotal time setting (volume over time)Rate (mL/h)Approx. Battery life (hours)Italian999-903IT100 hours25 12French999-903FRKVO rate125 8German999-903DE0.1 – 20 mL/h1200 4Russian999-903RUPatient safetyPump alarms/alertsTurkish999-903TUUltrasonic Air Sensor Air bubble size 0.04 – 2 mlAir in line / Up Occlusion, Down Occlusion, Near End Program,End Program / End of Infusion, Low Battery, End Battery, PumpUnattended, Door Open, System Error, Missing Set Key, with theuse of flow sensor accessory100 hrsIEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8,IEC 60601-1-11, IEC 60601-1-12, IEC 60601-2-24Dose Mode(Drug libraries)2000 user events logVolume to be infusedComplies with the current version of the following standardsTotal parenteralnutrition (TPN)Up to 128 drugs referred to as protocolsProduct CodeProgrammable infusion time (Dose over time)IntermittentFully programmable drug library, with automatic calculationof drug concentration programmable via PC withBodyComm software**LanguageOcclusion Pressure 100-1500 mmHg (10 mmHg increments)ContinuousProtocols libraryPorts2 x RJ45 – for drop sensor1 x RS232 (Male) – for PC communicationAdditional specificationsInsulation class II, type CFIngress Protection: IP33Linear Peristaltic mechanism25 doses* Achieved under nominal conditions** Only trained CME or BD associates or authorized representatives are allowed to configure BD BodyGuard infusion and syringe pumps and upload the clinician-approved protocolsto supported pumps.† Each order code contains several languages in addition to the primary language. Check with your local representative on product availability.

BD BodyGuard Pain Manager 1011BD BodyGuard Pain Manager infusion pump specificationsDimensions and weightProtocols libraryWeight (with standard battery) 410 gPump only (H/W/D) 112 x 89 x 40 mmFully programmable drug library, with automatic calculationof drug concentration programmable via PC withBodyComm software**Flow rate rangeUp to 2000 user events logBasal rate 0 to 100 ml/hr in 0.1 ml increments(depends on infusion modes)Power supplyKVO Rate 0 (OFF) - 5 ml/hrFlow rate accuracy - 5 %110-240 VAC, 50/60 Hz. 0.3 A maxBattery specifications*Volume to be infusedPain management solutionsDesigned around patients, the BD BodyGuard Pain Manageris an ambulatory infusion pump that offers a number of painmanagement modes to help improve quality of life and patientcomfort. The BD BodyGuard Pain Manager infusion pump has3 configurable modes: PCA, epidural and regional. It can be setto patients’ needs or clinical specialty via different infusion modes:continuous only, bolus only, continuous plus bolus, and auto bolus.The BodyGuard Pain Manager infusion pump can be used forinfusion through intravenous, subcutaneous, epidural, regionaland wound infiltration routes.Infusion Modes PCA Epidural RegionalMultiple Delivery Methods Basal only Basal & bolus Bolus onlyMultiple Bolus Types Patient bolus Auto bolus Patient bolus combinedwith auto bolusMediGuard Weight-basedDosing SoftwareOrder Codes†LanguageProduct rgeable Li-Polymer 7.4 V Battery1800 mAh.0.1 – 1000 mlRate (mL/h)Approx. Battery life (hours)Patient safety2515Ultrasonic Air Sensor Air bubble size 0.04 – 1 ml10015Occlusion Pressure adjustable 250-1500 mmHg(adjustable depending on infusion mode)Pump alarms/alertsComplies with the current version of the following standardsIEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8, IEC60601-1-11, IEC 60601-2-24, IEC 62304 and IEC 62366.Air in line / Up Occlusion, Down Occlusion, Pump Unattended, Endof infusion, Near End of Infusion, Low Battery, End Battery, PumpUnattended, Door Open, Missing Set Key, System ErrorPorts1 x RS232 (Male) – for PC communicationAdditional specificationsInsulation class II, type CFIngress Protection: IP33Linear Peristaltic mechanismFully Programmable Drug Library* Achieved under nominal conditions** Only trained CME or BD associates or authorized representatives are allowed to configure BD BodyGuard infusion and syringe pumps and upload the clinician-approved protocolsto supported pumps.† Each order code contains several languages in addition to the primary language. Check with your local representative on product availability.

BD BodyGuard Epidural12 13BD BodyGuard Epidural infusion pump specificationsDimensions and weightBattery specificationsWeight (with standard battery) 410 gRechargeable Li-Polymer 7.4 V BatteryPump only (H/W/D) 112 x 89 x 40 mm1800 mAh.Flow rateBasal rate 0 to 30 ml/hr in 0.1 ml incrementsFlow rate accuracy - 5 %*Volume to be infusedEpidural solutionsDesigned around patients, the BD BodyGuard Epidural infusionpump offers specific pain management modes to help improvequality of life and patient comfort. This latest edition of infusionpumps, specifically designed to meet clinicians’ needs, will help youmeet the strict demand of epidural. The BD BodyGuard Epiduralinfusion pump has features that help make even the mostchallenging regimes safer and simpler to infuse.Approx. Battery life (hours)25153015Protocols libraryPatient safetyFully programmable drug library, with automatic calculationof drug concentration programmable via PC withBodyComm software**Ultrasonic Air Sensor Air bubble size 0.04 – 1 mlUp to 2000 user events logOcclusion Pressure adjustable 250-1100 mmHgPIAB programming capabilitiesPower supplyPump alarms/alerts0.1 – 1000 mlOrder Codes†Rate (mL/h)Air in line / Up Occlusion, Down Occlusion, Pump Unattended, Endof infusion, Near End of Infusion, Low Battery, End Battery, DoorOpen, Missing Set Key, System ErrorLanguageProduct Code110-240 VAC, 50/60 Hz. 0.3 A maxEnglish999-683BDENComplies with the current version of the following 99-683FRAdditional specificationsGerman999-683DEInsulation class II, type CFDutch999-683NLIngress Protection: IP33Linear Peristaltic mechanismInfusion Mode EpiduralMediGuard Weight-basedDosing SoftwareDanish999-683DKSwedish999-683SEMultiple Delivery Methods Basal only Basal & bolus Bolus onlyFully Programmable Drug LibraryFinnish999-683FINorwegian999-683NOIEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8,IEC 60601-1-11, IEC 60601-2-24, IEC 62304 and IEC 62366Ports1 x RS232 (Male) – for PC communicationMultiple Bolus Types Patient bolus Auto bolus Patient bolus combinedwith auto bolus* Achieved under nominal conditions** Only trained CME or BD associates or authorized representatives are allowed to configure BD BodyGuard infusion and syringe pumps and upload the clinician-approved protocolsto supported pumps.† Each order code contains several languages in addition to the primary language. Check with your local representative on product availability.

BD BodyGuard T14 15BD BodyGuard T syringe pump specificationsDimensions and weightPatient safetyWeight (without battery) 230 gOcclusion Pressure adjustable 200–1500 mmHgPump only (H/W/D) 167 x 68 x 39 mmPost Occlusion Bolus Reduction System (POBRS)Flow rateBattery specificationsAdjustable between 0.1 ml/h and 650 ml/h9 V alkaline, IEC 6LR61 typeFlow rate accuracy - 5 %*Rate (mL/h)Approx. Battery life (hours)Bolus1 ml/h505 ml/h35Bolus flow rate 1–650 ml/hBolus volume 0–20 ml in 0.1 ml incrementsProgrammable infusion time1 min–99 hOrder CodesCompact designThe BD BodyGuard T syringe pump is a small, lightweightambulatory infusion pump which offers flexibility and reliability.Effortless transition between hospital and home care requirementsis the core of the BD BodyGuard T syringe pump.Infusion Mode: Continuous Bolus†Syringe sizesPump alarms/alertsOcclusion or Syringe Empty, Syringe Displaced during infusion,End Program, System Error, End BatteryAdditional specificationsInsulation class II, type CF2 ml to 50 ml (most commonly used manufacturers)**Ingress Protection: IP22Linear syringe driver mechanismLanguageProduct CodeComplies with the current version of the following standardsEnglish999-103BDENSwedish999-103BDSEIEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8,IEC 60601-1-11, IEC 60601-2-24, IEC 62304 and IEC 62366Program Types: Program lock on/off Rate mode or volume/time 3 point syringe detectionSyringes size 2 ml to 50 ml(most commonly used manufacturers)†* Achieved under nominal conditions** Only trained CME or BD associates or authorized representatives are allowed to configure BD BodyGuard infusion and syringe pumps and upload the clinician-approved protocolsto supported pumps.† Each order code contains several languages in addition to the primary language. Check with your local representative on product availability.

BD BodyGuardMicroSet range 16BD BodyGuard MicroSets17We offer a wide range of infusion sets that are specifically designed to optimize the outcomes of thedifferent therapies administered with the BD BodyGuard infusion pumps.From basic administration, to specialty sets for TPN, PCA, Epidural, Regional Anaesthesia and Oncology.Features of the range: All the sets have a microbore tubing (1.6 mm of innerbore) that translates into low priming volume As a safety feature, in all sets there is an anti-syphonvalve that prevents against free flow and back flow* Epidural sets yellow and yellow striped Regional anaesthesia sets grey and green Light resistant sets to be used with light sensitive drugsFilter sets with a 0.2 and 1.2 micron size for the use withspecific drugs or TPN therapy NRFit sets according to the new ISO standard(80369-6) to prevent missconnections in regionalanaesthesia care setting TPN set with a manual priming valve, a by-passableanti-syphon valve Color-coded sets for each therapy care areaLow sorbing oncology sets designed for theadministration of multiple secondary infusions throughthe SmartSite ports PCA sets blue and blue striped*Except the secondary sets and extension sets that have a back check valve.Check with your local representative on product availability.

General Admin SetsGeneral Admin Sets18SKUGEN00001120-160XYSKGEN00002GEN00004Type tubingClearClearClearLight resistantTubing Needle-freeIn-line FilterNoNoNoNoDrip chamber ventedDrip chamber ventedDrip chamber ventedDrip chamber ventedClampSlideSlideSlideRoller and slideAnti-syphon valveYesYesYesYes11 ml11 ml11 ml11 mlApprox. Tubing230 cm240 cm240 cm240 cmInner box Qty20Case Qty100Distal connectionApprox. Priming volume**The priming volume was calculated with half of the drip chamber YV100-163XNKSType tubingClearClearClearClearTubing materialPVCPVCPVCPVCY-PortNoNeedle-free2x Needle-freeNoIn-line FilterNoNoNoNoUnvented SpikeUnvented SpikeVented SpikeSyringe AdaptorClampSlideSlideSlideSlideAnti-syphon valveYesYesYesYesApprox. Priming volume4 ml6 ml5 ml5 mlApprox. Tubing230 cm250 cm280 cm250 cmInner box Qty20162020Case Qty10080100100Distal connection

TPN Infusion SetsTPN Infusion TF1.2 micron0.2 micron1.2 micron0.2 micron0.2 micron1.2 micron1.2 micron1.2 micron0.2 micronType tubingClearClearClearLight resistantClearType tubingClearClearClearClearTubing materialPVCPVCPVCPVCPVCTubing materialPVCPE-lined PVC - Low edle-portNo1.2 µm1.2 µm1.2 µm1.2 µm1.2 µm1.2 µm1.2 µm1.2 µm1.2 µmUnvented SpikeUnvented SpikeUnvented SpikeUnvented SpikeVented SpikeUnvented SpikeUnvented SpikeUnvented Spike2 x Unvented ideRollerYesYesYesYesYesAnti-syphon valveYes with manualpriming valveYesYesYes10 ml10 ml10 ml8 ml8 mlApprox. Priming volume7 ml8 ml8 ml8 ml per ChannelApprox. Tubing310 cm300 cm280 cm300 cm300 cmApprox. Tubing250 cm300 cm310 cm100 cmInner box Qty1616201620Inner box Qty20201610Case Qty80801008080Case Qty80808050In-line FilterDistal connectionClampAnti-syphon valveApprox. Priming volumeIn-line FilterDistal connection

PCA Infusion SetsPCA Infusion PCA00003120-160XSFMKPCA000050.2 micron0.2 micron0.2 micronType tubingType tubingBlue StripedBlue StripedClearBlue StripedTubing materialPVCPVCPE-lined PVC - Low sorbingPVCTubing materialY-PortNoNoNoNoY-PortIn-line FilterNoNoNoNoIn-line FilterUnvented SpikeUnvented SpikeUnvented SpikeAngle Spike - UnventedRollerRollerSlideSlideAnti-syphon valveYesyesYesApprox. Priming volume4 ml5 mlApprox. Tubing230 cmInner box QtyCase QtyDistal connectionClampClearClearBlue StripedPE-lined PVC - Low sorbingPVCPVCNoNoNo0.2µm0.2µm0.2µmUnvented SpikeUnvented SpikeNeedle-free - bag 150 mlClampSlideSlideSlideYesAnti-syphon valveYesYesYes4 ml6 mlApprox. Priming volume7 ml8 ml7 ml250 cm200 cm230 cmApprox. Tubing270 cm270 cm250 cm20202020Inner box Qty202010200100100100Case Qty10010050Distal connection

PCA Infusion SetsPCA Infusion Sets24SKU120-160XCSEK120-160XCSK121-160XCSEKBlue StripedBlue StripedBlueType tubingBlueBluePVCPVCPVCTubing materialPVCPVCLuer lockLuer lockLuer lockLuer lockNoNoNoNoNoNoUnvented SpikeUnvented SpikeUnvented SpikeSyringe AdaptorSyringe hon valveYesYesYesAnti-syphon valveYesYesApprox. Priming volume6 ml5 ml6 mlApprox. Priming volume5 ml5 mlApprox. Tubing240 cm250 cm240 cmApprox. Tubing240 cm240 cmInner box Qty202020Inner box Qty2020Case Qty100100100Case Qty100100Type tubi

IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8, IEC 60601-1-11, IEC 60601-2-24, IEC 62304 and IEC 62366. Protocols library Fully programmable drug library, with automatic calculation of drug concentration programmable via PC with BodyComm software** Up to 2000 user

Related Documents:

Ambulatory Infusion Pump Kit REF Description 350-1000 1 - Curlin 4000 Plus Ambulatory Infusion Pump 2 - “C” size alkaline batteries 1 - AC power adapter/charger 1 - Hard carrying case 1 - User’s Manual 4000 Plus Ambulatory Infusion System EASY TO USE EASYTO SETUP SOP

Infusion NursingJournal of The Journal of Infusion Nursing is a member benefit of the Infusion Nurses Society. INS is a professional association dedicated to enhancing infusion prac-tices that will improve patient outcomes. Through its many member benefits, INS offers access to the latest infusion research, technology, and education. For

This manual concerns only the CADD-Prizm VIP (Variable Infusion Profile) Model 6100 and Model 6101 ambulatory infusion pumps. The pump has the following delivery modes: PCA PCA 6210 (all revision letters) Continuous CONTIN 6220 (all revision letters) TPN TPN 6230 (all revision letters) Intermittent INTERMT 6240 (all revision letters) This manual is intended for clinician use only.

To resume an infusion: 1 From the toolbar, select CONTINUE. TO STOP/RESUME AN INFUSION To stop an infusion using the STOP hard key: 1 At the bottom of the pump, press STOP. The infusion pauses. To resume an infusion: 1 From the toolbar, select CONTINUE. 2 From the toolbar of the Attentio

Roboz Surgical Instrument Co Subject: Vascular Access Keywords: infusion instruments, infusion tubing, polyethylene tubing, introduction needle, infusion canula, fastbreak cannulas, splitable introducer cannula, heart holding forceps, micro injection needles, advance infusion pump, advance infusion table,

IV INFUSION FAQ SHEET . 20. 14. 1. A Hydrating infusion is defined as an infusion of fluid and electrolytes (eg, normal salin e, D5-1/2 normal saline 30mEq KCL/liter). Administration of electrolytes for a therapeutic purpose is billed as a hydrating infusion. 2. Do we charge for IV fluids (IVF) used behind blood, heparin or nitroglycerin? a.

infusion pump is the preferred and safer way of delivering this type of infusion. Community IV services may use a control flow administration set. When the infusion bag is empty and disconnected from the patient the infusion giving set tubing will contain a residual quan

Jan 01, 2021 · Code Ambulatory Surgical Center Services Fee Schedule 2021 The Ambulatory Surgical Center fee schedule does not have rates listed due to reimbursement though . 11750 11755 11760 11762 11765 Ambulatory Surgical Center Fee Schedule 2021 Page 3. Code