COMPACT NS400/630 Circuit BreakersIEC 947-2 Rated COMPACT NS400/630 Circuit BreakersComplete DeviceCOMPACT NS400/630N Circuit Breaker with STR23SE Trip Unit—45 kA at 380/415 VacBus Bar ConnectionNS400Npushtotrip90 %Ir105alarmSTRIo.9.823 SE.851.54Ir .933.95Im568Ir2.88.98.63Im101.5 Irx1.8x Iox IntestRating (A)1502504006303PCatalog No.List PriceNJNFE36150E20 047874PCatalog No.List PriceNJNFE46150E20 00E20NJNLE46630E20NS630NCable 8295969COMPACT NS400/630H Circuit Breaker with STR23SE Trip Unit—70 kA at 380/415 VacBus Bar 864686771NS630HCable Connection100NS400HNS630HCOMPACT NS400/630L Circuit Breaker with STR23SE Trip Unit—150 kA at 380/415 VacBus Bar 8738810119NJNFE36000S402663NJNFE46000S40 634399NS630LCable Connection150NS400LNS630LCOMPACT NS400/630NA Molded Case Switchsputohtrip90105a la rSTRte s23 SEm% IrBus Bar Connection400NS400NA630NS630NACable Connection400NS400NA630NS630NAtContinued on next pageRatings and interrupting ratings: page 65Cable range: pressure terminals are suitablefor copper and aluminum cables:c 400 A terminal:1 cable: 35 to 300mm2 Cu or Alc 630 A terminal:2 cables: 85 to 240mm2 Cu or AlDE2Other termination: page 81Other trip units: page 79Accessories: page 83International Catalog Number: page 102Additional information:c Catalog no. ABTED297054ENc Installation Guide no. ABTED297054ENc Data Sheet no. ABTED396041c D-Fax no. 2384DiscountSchedule77Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersComplete Device—continuedCOMPACT NS400/630H Circuit Breaker for DC Application—Magnetic OnlyBus Bar ConnectionsputoNS400HRating (A)400NS630H630htrip90105a la rSTR23 SE4% IrmIm56TypeMP1MP2MP1MP2MP3Magnetic ��4000Trip FunctionD10D32D10D32D36Catalog D32NJHLE36630D36List Price 4548454847104710471038Ir21 .5te stIm10x IrCable MPACT NS400/630H Circuit Breaker for Motor Circuit Protection—Magnetic OnlyBus Bar e 02016–4000M36NJHFE36400M36 646880COMPACT NS400N Circuit Breakers – 1000 Vac—10 kA at 1150 VacRating (A)pushtotrip400IrImBus Bar Connection150NS400N with250STR23SP Trip400UnitCable Connection150NS400N with250STR23SP Trip400UnitRatings and interrupting ratings: page 65Cable range: pressure terminals are suitablefor copper and aluminum cables:c 400 A terminal:1 cable: 35 to 300mm2 Cu or Alc 630 A terminal:2 cable: 85 to 240mm2 Cu or Al78DE23PList PriceNJNFE1150E20NJNFE1250E20NJNFE1400E20 304030403385NJNLE1150E20NJNLE1250E20NJNLE1400E20 322032203625Other termination: page 81Other trip units: page 79Accessories: page 83Additional information:c Catalog no. ABTED297054ENc Installation Guide no. ABTED297054ENc Data Sheet no. ABTED396041, ABTED397078 (1000 Vac)c D-Fax no. 2384, 998 (1000 Vac)DiscountScheduleCourtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersCOMPACT NS400/630 Circuit Breaker Basic Frame3PCatalog No.Rating (A)List Price4PCatalog No.List PriceNS400/630N—Bus Bar Connectionpushtotrip150250400630NJNFE36150F40 33629NJNFE46150F40 LFE46630F635990599059908641NS400/630H—Bus Bar Connection150250400630NS400/630L—Bus Bar Connection150250400630Electronic Trip Unit75STRIo.9.8.88.6353 UEIr .93.95.98.851.5x Intr1.8 et x Iocurr.s2401206030testtrtmIrIm I240151.5 Ir(s) at10590I60Im54638210Ir1.5up xpick.3.3.243%Ir68102121.5 up x Inpick-tm(s) .2.1.1Trip FunctionCatalog No.List PriceE2032420 3244132434169126026026192602606926700 2t offIonLong-time and Instantaneous ProtectionSTR23SELong-time, Short-time, Instantaneous Protection and municaton wiringReplacement battery for STR53UEMotor Circuit ProtectionSTR43ME-FOptional STDAM (110/240 Vac)Optional STDAM (24/48 Vdc)STR43ME-FIOptional STDAM (110/240 Vac)Optional STDAM (24/48 Vdc)Communicaton wiringReplacement battery for STR43MESummary of options:F: Fault indicatorsT: Residual type ground fault protectionI: AmmeterDE2E48Continued on next pageDiscountSchedule79Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersVIGITM Module or Ammeter ModuleTrip Function3PCatalog No.List PriceVDVE3245532453Operation is identical to that of a VIGI module but without circuit breaker tripping220 to 440 VacVF32659Rating4PCatalog No.List Price 27652765324563245432457 8976976VIGI ModuleMB 220 to 440 Vac0.3-30 AMB 440 to 550 Vac0.3-30 AConnection for a 4P VIGI on a 3P circuit breakerInsulating Monitoring ModuleAmmeter Module400 A630 265732857929929AAmmeter Module with I Max400 A630 AACurrent Transformer Module400 A630 A80DE2DiscountScheduleCourtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersInstallation and Connectionc For factory-installed connection accessories complete the circuit breaker catalog numberby inserting the termination numbers in the appropriate block.c For field-installable accessories order the 5-digit catalog number.NJN LE36400E20Termination No.Term. No.Catalog No.List Price3696636967 Bus Bar ConnectionBus Bar Connection Hardware3P (three per set)4P (four per set)Front ConnectionDistance between poles of all COMPACT and VIGICOMPACT NS400/630/N/H/L circuit breakers is 1.8 in./45mmA set of spreaders is available for connection to extend this distance to 2.1 in./52.5mm or 2.8 in./70mm2.1 in./52.5mm3P4P2.8 in./70mm3P4PTerminal Extensionsangular terminalsset of 3set of 4edgewise padsset of 3set of 63248796128197264Cable Connection400 A Lugs (1) 2/0 AWG to 600 kcmil Cu or 500 kcmil Al/35 to 300mm2 Cu/AlField-installableOne side3P4PFactory-mountedBoth sides3P4PLine side only3P4PLoad side only3P4P630 A Lugs (2) 2/0 AWG to 500 kcmil Cu/Al/35 to 240mm2 Cu/AlField-installableOne side3P4PFactory-mountedBoth sides3P4PLine side only3P4PLoad side only3P4PVoltage Take Offs for 400 and 630 A Lugs (Set of Two)3247932480LLMMPP3248132482 18324773247832475 (2)324763256232475 (2)32476 (2)32563538712139 ea.16694139 ea.166 ea.1023P4P3P4P3P4PSet of r Connection Bus Bar Connection Rear ConnectionMixed Rear Connection KitConsisting of:3P4PShort rear connectionsLong rear connectionsShort terminal coversShort rear connectionsLong rear connectionsShort terminal coversKit 3PKit 4PpushtotripSSConnection AccessoriesTerminal ShieldsShort (1 pair)Long (1 pair)For spreaders (1 pair)Phase BarriersTwo Insulating Screens(fixed breaker)2.1 in./52.5mm pitch2.8 in./70mm pitchContinued on next pageDE2DiscountSchedule81Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersInstallation and Connection—ContinuedTerm. No.Catalog No.List PriceNN3253832539 Plug-in Mounting Bus Bar Connection Plug-in KitKit for COMPACT Circuit Breaker(Stationary and Moving Part)Consisting of:3P4PStationary PartPlug-in base3P4PMoving PartSafety trip interlockShort terminal coverspushtotripPower connectionsKit for VIGICOMPACTTM Circuit Breaker(Stationary and Moving Part)Consisting of:Stationary PartPlug-in base3251632517Power 518 (3)32518 (4)3254032541NN3P4PMoving partSafety trip interlockShort terminal covers9801208299410260 ea.60 ea.11871484325163251767783732520325623256332519 (3)32519 (4)2994102129 ea.129 ea.HJ003P4P3P4PDrawout Mounting Bus Bar Connection Drawout KitKit for COMPACT Circuit Breaker(Stationary and Moving Part)Consisting of:3P4PStationary PartPlug-in baseFixed part of chassisMoving PartSafety trip interlockShort terminal coverspushtotripPower connectionsMoving part of chassisKit for VIGICOMPACTTM Circuit BreakerConsisting of:Stationary PartPlug-in baseDD3P4P2P/3P/4P3254232543 4P3P4PDD299410260 ea.60 P/4P32520325623256332519 (3)32519 (4)325332994102129 ea.129 ea.1479-wire connector9-wire connectorSupport for 3 moving connectors292733252332525603827Two IP4 shutters for plug-in baseLong insulated terminals3P4P325213252632527516485Extended escutcheon for toggleExtended escutcheon for VIGI moduleLocking devices (not included)Two position indicating switches 131Fixed part of chassisMoving partSafety trip interlockShort terminal coversPower connectionsMoving part of chassis3P4P2P/3P/4P32520325623256332518 (3)32518 (4)325333254432545HJ00Plug-in and Chassis AccessoriesSecondary Disconnecting BlocksFixed partMoving partPlug-In Base AccessoriesOF1SDMN/MX82OF2SDEMTOF3SDVCOMR/TChassis AccessoriesDE2DiscountScheduleCourtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersAccessoriesc For factory-installed accessories complete the circuit breaker catalog number by insertingN J N L E36 4 00E 20A B S AOptionsthe option number in the appropriate block.c For field-installable accessories order the 5-digit catalog number.Volts (V)ElectricalAccessoriesOption No.Catalog No.List PriceAAABACBC ➀BD ➀AEAFAGBH ➁BJ ➁2945029450 (2)29450 (3)29450294502945229452 (2)29452 (3)2945229452 Auxiliary Switch (SPDT Type)StandardOne auxiliary switch (OF)Two auxiliary switches (OF)Three auxiliary switches (OF)Alarm switch (SD)Overcurrent trip switch (SDE)Low LevelOne auxiliary switch (OF)Two auxiliary switches (OF)Three auxiliary switches (OF)Alarm switch (SD)Overcurrent trip switch (SDE)Auxiliary, Alarm and Overcurrent Trip Switches with Communication ModuleLow levelOF SD SDE189189 ea.189 ea.189189236236 ea.236 5545580745535277545532029272144Shunt trip and Undervoltage TripMX(Shunt trip)AC 50/60 HzDCMNAC 50/60 Hz(Undervoltage 250MN 48 Vac with time delayConsisting of:MN 48 VdcDelay unit 48 V 50/60 HzMN 220/240 Vac with time delayConsisting of:MN 250 VdcDelay unit 220/240 V 50/60 URUSWiring Harness9-wire disconnecting harnessContinued on next page➀ BE BC BD➁ BK BH BJDE2DiscountSchedule83Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersAccessories—Continuedc For factory-installed accessories complete the circuit breaker catalog number by insertingN J N L E36 4 00E 20A B S AMAOptionsthe option number in the appropriate block.c For field-installable accessories order the 5-digit catalog number.ElectricalAccessoriesMotor Operator with SDE AdapterMT400 forNS400AC 50/60 Hz21tou/aumanOpushIpushONOFFDCMT630 forNS630AC 50/60 HzDCVoltage (V) Option No.Catalog No.List Price48 2648 5503233952Locking device with Ronis key lock (not included)Operations counterMLMAMDMFMHMOMPMRMSMLMAMDMFMHMOMPMRMSWiring Harness9-wire disconnecting harnessMotor Operators with Communication and Auxiliary Switches ModulesMT400 forAC 50/60 HzNS400MT630 forAC 50/60 HzNS63021tou/aumanOpushIpushONOFFTest KitsMini test kit (battery not supplied)Portable test kitCommunicationModuleData ConcentratorDC150AC 50/60 Hzand DCJBusBBucomscomerror24VOKerrorN 1N 1Continued on next page84DE2DiscountScheduleCourtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT NS400/630 Circuit BreakersAccessories—Continuedc For factory-installed accessories complete the circuit breaker catalog number by insertingN J N L E36 4 00E 20A B S AMA R D 1 2Optionsthe option number in the appropriate block.c For field-installable accessories order the 5-digit catalog number.Operating HandlesOption No.Catalog No.List PriceStandard black handleRed handle on yellow bezelMCC conversion accessoryCNOMO conversion accessoryRD12RD2232597325993260632602 Standard black handleRed handle on yellow bezelTelescopic handle for drawout 22CSJ109422A121622424363Direct MountedONIOOFF23225865123Door MountedONIOOFFONIOFFAccessoriesKey lock adapterKey locks➀Ronis 1351.500Profalux KS5 B24 D4ZIndicationOne early-break switchauxiliary switchTwo early-make switchesCable Operating Mechanism and A1 Handle3P operating mechanism36/914cable length (in./mm)90/1524120/3048A1 painted handle (order separately)ONIprofaluxOOFFOFFpushtotripONOFFLocks, InterlockingCP1 DiscountCP1 DiscountCP1 DiscountCP1 DiscountHandle Padlocking DeviceRemovable (lock OFF or ON)Fixed (lock OFF or ON)Fixed (lock OFF only)2937032631NJPAF327777Mechanical for circuit breakers with rotary operating handles32621313Mechanical for circuit breakers with toggles32614313Key lock type(2 locks, 1 560109293753255329314282175Interlocking (Not UL anel EscutcheonsToggleRotary operating handle, motor operator or extended escutcheonVIGI moduleVIGI module or ammeter (IP405)Handle Rubber BootSealing AccessoriesSpare Extended Handles100 Identification Labels➀ Will need the key lock adapter above (Catalog No. 32604) for both Ronis and Profalux key lock installation.Spare PartsDE2DiscountSchedule85Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT C801/1001/1251 Circuit BreakersIEC 947-2 Rated COMPACT C Circuit BreakersComplete DeviceCOMPACT C801/1001/1251 Circuit Breaker with STR25DE Trip UnitBus Bar ConnectionRating (A)3P 3TCatalog No.List Price4P 3TCatalog No.List PriceCKAXFE36080LICKAXFE36100LICKAXFE36125LI LI KIXLE46100LI1214923875C801/1001/1251N—50 kA at 380/415 0 kA at 380/415 VacC801HC1001HC1251H80010001250C801/1001L—150 kA at 380/415 VacC801LC1000L8001000Cable ConnectionC801/1001/1251N—50 kA at 380/415 0 kA at 380/415 VacC801HC1001HC1251H80010001250C801/1001L—150 kA at 380/415 VacC801LC1000L8001000COMPACT C801/1251NI Molded Case SwitchBus Bar 62010308Cable ConnectionC801NIC1251NIRatings and interrupting ratings: page 65Cable range: pressure terminals are suitablefor copper and aluminum cables:c 800 A terminal:1 to 3 cables: 70 to 185mm2 Cu or Alc 1250 A terminal:1 to 4 cables: 70 to 240mm2 Cu or Al86DE2Other termination: page 89Other trip units: page 88Accessories: See page 91Additional information:c Catalog no. ABTED297054ENc Installation Guide no. ABTED297054ENc Data Sheet no. ABTED396042c D-Fax no. 999DiscountScheduleCourtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

COMPACT C801/1001/1251 Circuit BreakersComplete Device—ContinuedCOMPACT C1251N Circuit Breaker with STR25DE Trip Unit —1000 VacRating (A)3P 3TCatalog No.List PriceCKAXFE31040LICKAXFE31080LICKAXFE31125LI LI77901007812316Bus Bar Connection4008001250Cable Connection4008001250COMPACT C1251N DC Circuit Breaker for DC Application—Magnetic OnlyRating (A)TypeMagnetic3PCatalog No.List PriceCKAXFE37125M2CKAXFE37125M4 99349934Bus Bar Connection1250P21P411600–3200 A3200–6400 ARatings and interrupting ratings: page 65Cable range: pressure terminals are suitablefor copper and aluminum cables:c 800 A terminal:1 to 3 cables: 70 to 185mm2 Cu or Alc 1250 A terminal:1 to 4 cables: 70 to 240mm2 Cu or AlDE2Other termination: page 89Other trip units: page 88Accessories: See page 91Additional information:c Catalog no. ABTED297054ENc Installation Guide no. ABTED297054ENc Data Sheet no. ABTED397062c D-Fax no. 99

IEC 947-2 Rated COMPACT NS400/630 Circuit Breakers Courtesy of Steven Engineering, Inc. 230 R! yan Way, South San Francisco, CA 94080-6370 M! ain Office: (650) 588-9200 !Outside Local Area: (800) 258-9200 ! www .stevenengineering.comFile Size: 1MB

Related Documents:

¾Norma Europea: EN 60947 ¾Norma Española: UNE-EN 60947 IEC 947-1 Parte 1: Reglas generales IEC 947-1 Parte 2: Interruptores automáticos IEC 947-1 Parte 3: Interruptores, INt. Secc., Int. Fusible IEC 947-1 Parte 4: Contactores y Arrancadores motor IEC 947-1 Parte

Posição de Operação 2 PO1 Positive Opening 1 to IEC 947-5-1 Apertura positiva 1 Zwangsöffnung 1 Ouverture positive 1 Apertura forzata 1 Abertura Positiva 1 para según IEC 947-5-1 gemäß IEC 947-5-1 selon CEI 947-5-1 Conforme alla norma IEC 947-5-1 IEC 947-5-1 PO2 Positive O

IEC 61215 IEC 61730 PV Modules Manufacturer IEC 62941 IEC 62093 IEC 62109 Solar TrackerIEC 62817 PV Modules PV inverters IEC 62548 or IEC/TS 62738 Applicable Standard IEC 62446-1 IEC 61724-1 IEC 61724-2 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/

IEC has formed IECRE for Renewable Energy System verification - Component quality (IEC 61215, IEC 61730, IEC 62891, IEC 62109, IEC 62093, IEC 61439, IEC 60947, IEC 60269, new?) - System: - Design (IEC TS 62548, IEC 60364-7-712, IEC 61634-9-1, IEC 62738) - Installation (IEC 62548, IEC 60364-7-712)

IEC 61869-9, IEC 62351 (all parts), IEC 62439-1:2010, IEC 62439-3:2010, IEC 81346 (all parts), IEC TS 62351- 1, IEC TS 62351- 2, IEC TS 62351- 4, IEC TS 62351- 5, Cigre JWG 34./35.11, IEC 60044 (all parts), IEC 60050 (all parts), IEC 60270:2000, IEC 60654-4:1987, IEC 60694:1

la norme CEI 947--5--2 . IEC 947--5--2 10--55Hz, 1mm de amplitud, satisface o supera IEC 947--5--2 10--55Hz, 1mm de amplitude, atende ou excede a norma IEC 947--5--2 Poweronfalsepulseprotection Protection l’impulsion à la mise sous tension Protezione falsi impulsi in accensione Einsc

Rated voltage : 15.8kV (ANSI)/17.5kV (IEC) Rated current : 7500A Rated frequency : 50/60Hz Rated breaking current : 63kA Standards : IEEE (ANSI) C37.013, IEC 60694, IEC 60298, IEC 60129, IEC 60044-1 & -2, IEC 60099-4, IEC 60358 The Investors’ and

Key words: Korean language teaching, Indian contexts, problems faced in learning Korean 1. Introduction The much awaited Korean Language course began in September 2012 in Manipur University. It is now a well-known fact that the people of Manipur, especially the youth, are very drawn to Korea and its culture. It is due to this emulation towards .