Consumables and Supplies Reference GuideOptima 7300 V ICP-OESDemountable TorchesDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow.Demountable Quartz Torches# of Slots33 ABC Fully Demountable Torch KitPart No.N0771500N0774075Ceramic D-TorchDescriptionD-Torch with Quartz Outer TubeQuartz Outer TubeBase and Inner TubeRetaining RingPart No.N0777051N0777053N0777054N0777055Torch BonnetDescriptionTorch BonnetPart No.N0775289Quick-Change Torch ModulesDescriptionQuick-Change Torch Module for HF-Resistant AnalysisQuick-Change Torch Module for Used Oil AnalysisPart No.N0770911N0770910Ignitor TapeDescriptionCopper Ignitor TapePart No.N0775297Torch O-RingsLocationDimensionsBall Joint0.301 i.d., 0.070 w.d.Complete O-Ring KitIncludes:Qty1221Part No.09926070N0770916Part No.09902155099022070990224709926070

NebulizersOffer high-quality sample introduction for a wide variety of applications.Meinhard NebulizersProvide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%).MEINHARD Nebulizers are self-aspirating and must not be used with solutions containing hydrofluoric acid. All requirean end cap for use with Ryton Scott spray chambers.TypeType AType CType KApplicationGeneral purposeHigh dissolved solidsReduced flow, and organicsPart No.0047202000472022N0681574Meinhard Nebulizer PartsDescriptionLiquid-End Connector Kit, 4 mmPart No.N0777414Nebulizer Clip for MEINHARD NebulizersN0777460End Cap for Concentric Glass NebulizersDescriptionEnd CapPart No.N0680504MicroMist NebulizersAr Flow Rate0.7 L/min0.7 L/min0.7 L/min0.7 L/minUptake Rate0.05 mL/min0.1 mL/min0.2 mL/min0.6 mL/minPart No.N0775349N0775348N0775347N0775346Requires Quick Disconnect Part No. N0770336.SeaSpray NebulizersAir Flow Rate0.7 L/minUptake Rate2 mL/minPart No.N0775345PEEK MiraMist NebulizerThe MiraMist fits regular spray chambers as a direct replacement for glass concentric nebulizers. Its features includestandard pressure (45 psi), low sample flow and enhanced parallel path design.DescriptionPEEK MiraMist Uptake Rate0.2 to 2.5 mL/minPart No.N0775330MicroFlow NebulizersMicroFlow nebulizers are constructed entirely from chemically resistant fluoropolymers, ideal for strong acids, alkalis,organics, high salt solutions and high solid concentrations. They are resistant to clogging, are reliably self-aspirated orpumped and produce a fine aerosol for high transport efficiency and high sensitivity.DescriptionPolyPro ST NebulizerPFA-ST NebulizerPFA-ST3 Microflow NebulizerPart No.N0777219N0777049N0777676GemCone NebulizersLow-flow GemCones permit lower nebulizer gas flow rates, useful for spectral lines with high excitation energiesand for providing a more robust plasma. GemCone Nebulizers require an end cap for use with Ryton Scott SprayChambers.DescriptionPart No.GemCone Low-Flow NebulizerN0770358GemCone High Dissolved SolidsN0690670GemCone Sample Capillary AdapterN0371505End Cap for GemCone NebulizersN0680504Quick Disconnect TubingN07703362

Nebulizers, continuedGemTip Cross-Flow II NebulizersExcellent general purpose nebulizer for the analysis of strong mineral acids (including HF) and samples with less than5% dissolved solids.DescriptionGemTip Cross-Flow II NebulizerGemTip Cross-Flow II Tip KitsO-Ring Kit for GemTip Cross-Flow NebulizersPart No.N0770546N0690676N9300067Spray ChambersThe spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriatedroplet size distribution to reach the plasma.Baffled Cyclonic Spray ChambersTypeStandardO-Ring FreeHF ResistantPart No.N0771501N0775356N0771550Unifit Drain Connectors with Tubing for Baffled Cyclonic Spray ChambersSample Tube Size1 16 in. o.d. x 0.75 mm i.d. x 700 mm1.3 mm o.d. x 0.75 mm i.d. x 700 mmQty33Part No.N0774080N0774077Tracey TC44 Spray ChambersTypeTC-44 Cyclonic Spray ChamberTracey TFE Spray Chamber with HelixPart No.N0771550N0777497Injectors and Injector Support AdaptersAlumina InjectorsAlumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with lessvolatile organic solvents, e.g., xylene.Dimensions2.0 mm i.d.1.2 mm i.d.Part No.N0695362N0771531Sapphire InjectorsSapphire injectors are ideal for silicon applications.Dimensions2.0 mm i.d.Part No.N0695494Quartz InjectorsQuartz injectors are designed for organic solvents and non-HF matrices.Dimensions0.8 mm i.d.1.2 mm i.d.1.6 mm i.d.2.0 mm i.d.Part No.N0695461N0695460N0695449N0695442Injector Support AdaptersSpray Chamber(bottom) Cyclonic(top) Cyclonicwww.perkinelmer.com/suppliesPart No.N0771526N07715273

Purge Windows and Load CoilPurge Extension WindowsViewRadialPart No.N0581497Load CoilDescriptionLoad CoilPart No.N0771536Autosampler Pump Tubingi.d.(mm)Stop ColorsStandard PVC(Pkg 12)Flared PVC(Pkg 12)0.19 orangeredN0695476N07731110.25 orangeblueN0773117N07731120.38 orangegreenN0777110N0777042Solvent Flex(Pkg 12)Viton (Pkg 12)Santoprene (Pkg 3550Silicone(Pkg 6)00473552whitewhite1.02 N0777442 43N0777447greengreen1.85purple2.79white3.18 pler Tubes with CapsCapacitySizeTypeQtyPart No.15 mL17 mm x 120 mmConical Bottom500B019323350 mL28 mm x 115 mmConical Skirted Bottom500B0193234Autosampler Tubes4CapacitySizeTypeQtyPart No.8 mL13 mm x 100 mmRound Bottom1,200N07771568 mL13 mm x 100 mmRound Bottom250N077715915 mL17 mm x 100 mmRound Bottom1,200N077716715 mL17 mm x 100 mmRound Bottom250N077716816 mL17 mm x 100 mmRound Bottom1,000 (packs of 125)N930120550 mL30 mm x 115 mmRound Bottom500 bulkN077715850 mL30 mm x 115 mmRound Bottom500 (50 tubes per bag)N0777164Plug for 15 mL N0777167 Vials1,200N0777599

StandardsSingle-Element Standards – 1,000 mg/LWhatever your application, you can depend on PerkinElmer Pure Standards to yield reliable, accurate results.PerkinElmer offers a wide selection of atomic spectroscopy calibration standards. Each solution is supplied with acomprehensive Certificate of Analysis that documents the quality and reliability.ElementSymbolMatrixPure Grade 125 mLPart No.Pure Grade 500 mLPart No.AluminumAl2% HNO3N9300184N9300100CadmiumCd2% HNO3N9300176N9300107CalciumCa2% HNO3N9303763N9300108ChromiumCr2% HNO3N9300173N9300112CopperCu2% HNO3N9300183N9300114IronFe2% HNO3N9303771N9300126LeadPb2% HNO3N9300175N9300128MercuryHg10% HNO3N9300174N9300133SodiumNa2% HNO3N9303785N9300152ZincZn2% HNO3N9300178N9300168Universal Data Acquisition Standards KitMatrixContentsVol.Solution Kit (Includes items listed below – 1 bottle of each)Part No.N93062255% HNO310 mg/L: Ce, Dy, Er, Eu, Gd, Ho, La, Lu, Nd, Pr, Sm, Sc,Tb, Th, Tm, Y, Yb125 mLN93002325% HNO310 mg/L: Al, Ag, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cs, Cu,Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Rb, Se, Sr, Ti, V, U, Zn125 mLN930023310% HCl/ 1% HNO3 10 mg/L: Au, Hf, Ir, Pd, Pt, Rh Ru, Te, Sb, Sn125 mLN93002345% HNO310 mg/L: Hg125 mLN9300253H2O/tr HF10 mg/L: B, Ge, Mo, Nb, P, Re, S, Si, Ta, Ti, W, Zr125 mLN9300235Vol.Part No.125 mLN9300231125 mLN9300232125 mLN9300233Multi-Element StandardsMatrixContentsMulti-Element Solution 12% HNO310 mg/L: Be, Bi, Ce, Co, In, Mg, Ni, Pb, UMulti-Element Solution 25% HNO310 mg/L: Ce, Dy, Er, Eu, Gd, Ho, La, Lu, Nd, Pr,Sc, Sm, Tb, Th, Tm, Y, YbMulti-Element Solution 35% HNO310 mg/L: Ag, Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr,Cs, Cu, Fe, Ga, Hg*, In, K, Li, Mg, Mn, Na, Ni,Pb, Rb, Se, Sr, Tl, U, V, Zn*Supplied in separate bottle.Multi-Element Solution 3 without Mercury N9301720Multi-Element Solution 410% HCl/1% HNO310 mg/L: Au, Hf, Ir, Pd, Pt, Rh, Ru, Sb, Sn, Te125 mLN9300234125 mLN9300235Multi-Element Solution 5H2O/tr HF10 mg/L: B, Ge, Mo, Nb, P, Re, S, Si, Ta, Ti, W, Zr5

Standards, continuedInterference Check StandardsMatrixContentsVol.Part No.5,000 mg/L: Al, Ca, Mg2,000 mg/L: Fe500 mLN93002261,000 mg/L: Cr, Cu, Mn,Ni, Ti, V500 mLN9300228125 mLN9300227125 mLN9300229Interferents A5% HNO3Alternate Interferents A5% HNO3Analytes B5% HNO3/trTartaric Acid/tr HF100 mg/L: Cd, Ni, Zn60 mg/L: Sb50 mg/L: Ba, Be, Co, Cr, Cu, Mn, V20 mg/L: Ag10 mg/L: As, TlAlternate Analytes B5% HNO3/tr Tartaric Acid/tr HF100 mg/L: Al, As, B, Mo, Na, Sb, Se, Tl10 mg/L: Ca, Fe, Mg, SiInstrument Setup SolutionsMatrixContentsVol.Part No.Vis Wavecal Solution2% HNO350 mg/L: K10 mg/L: La, Li, Mn, Na, Sr1 mg/L: Ba, Ca250 mLN9302946UV Wavecal Solution5% HCl100 mg/L: K, P, S20 mg/L: As, La, Li, Mn, Mo, Na, Ni, Sc125 mLN06814705% HCl100 mg/L: K, P, S20 mg/L: As, La, Li, Mn, Mo, Na, Ni, Sc500 mLN0582152Low UV Standard2% HNO310 mg/L: Al, P, S250 mLN0691580Calcium Stray Light StandardH 2O10,000 mg/L: Ca125 mLN0691581Every day you count on PerkinElmer to provide you with solutions that deliver reliable performance, control operating costs andmaximize operational time. Our complete portfolio of consumables, parts, supplies, training and service helps you meet bothroutine and demanding measurement challenges. We invest heavily in testing and validating our products to ensure you receiveguaranteed compatibility and performance – on-time, for every instrument in your laboratory.For a complete listing of consumables and supplies, please visit www.perkinelmer.com/suppliesPerkinElmer, Inc.940 Winter StreetWaltham, MA 02451 USAP: (800) 762-4000 or( 1) 203-925-4602www.perkinelmer.comFor a complete listing of our global offices, visit www.perkinelmer.com/ContactUsCopyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.009641 01

Vis Wavecal Solution 2% HNO 3 50 mg/L: K 250 mL N9302946 10 mg/L: La, Li, Mn, Na, Sr 1 mg/L: Ba, Ca UV Wavecal Solution 5% HCl 100 mg/L: K, P, S 125 mL N0681470 20 mg/L: As, La, Li, Mn, Mo, Na, Ni, Sc 5% HCl 100 mg/L: K, P, S 500 mL N0582152 20 mg/L

Related Documents:

ITEM ICC ICP 1 Adaptation of Space, Materials and Equipment.62 ICP 2 Adult Involvement in Peer Interactions.78 ICP 3 Adult Guidance of Children's Play.11 ICP 4 Conflict Resolution.70 ICP 5 Membership.84 ICP 6 Relationships between Adults and Children.75 ICP 7 Support for Communication.51 ICP 8 Adaptations of Group Activities.72 ICP 9 Transitions between Activities.95

same time period that ICP-MS has been available, the difference is even more dra-matic. From 1983 to the present day, more than 17,000 ICP-OES systems have been installed — more than four times the number of ICP-MS systems. If the comparison is made with all atomic spec-troscopy instrumentation (ICP-MS, ICP-OES, graphite furnace atomic absorption

Spare part drawing heating system OES Mini ETZ E - HL-Heizung MPKR E OES 6.10 Mini OES 10.10 Mini OES 6.06 2in1 OES 6.10 2in1 E008 E007 E005 E010 E011 E012 E004 E003 E001. . C0055019322 Data cable between easyTOUCH operating module and control module P3 C0062619973 Retrofit kit for supply module (P2, P3, OES mini)

AAnalyst 200/400 Atomic Absorption Spectrometers 11 PinAAcle 900 Atomic Absorption Spectrometers 11 Optima 8x00 ICP-OES Spectrometers 11 NexION 300 ICP-MS Spectrometers 12 Importance of Atomic Spectroscopy To Specific Markets 13 Atomic Spectroscopy Detection Limits

Spare part drawing upper casing OES mini easyTouch. ETZ C - Oberkasten ET DI 8 M P . C. OES mini 6.06 easyTOUCH. C009 C013 C005 C007 C018 C015 . Spare part drawing heating system OES mini. ETZ E - HL-Heizung 8MPKR. E. OES 6.06 mini . C005 - 5019322 - Data cable between easyTOUCH operating module and control moC005 - 5019322 - Datenkabel .

Four reasons to upgrade to next-generation ICP-OES technology Introduction Users report that several features of most conventional ICP-OES spectrometers can cause

The next component to consider is the torch for the ICP-OES instrument. To clean the torch of the Agilent 5100 Series ICP-OES instrument, the outer tube should be soaked in aqua regia (mixture of hydrochloric acid and nitric acid) for one hour - Agilent offers a very convenient cleaning stand for this purpose.

The Avio 220 Max ICP-OES instrument is bench-mounted and may need to be moved for service and preventative maintenance. It is preferred to leave a space of 45 cm (18 in.) between all sides of the instrument and lab walls to facilitate access. The heat dissipated directly into the room air by the Avio 220 Max ICP-OES is about 2200 watts