Metasys System Field Equipment Controllersand Related Products Product BulletinLIT-120110422020-10-05OverviewThe Metasys system family of Field EquipmentControllers (FECs) comprises a group of versatile fieldcontrollers designed to monitor, control, and integrate awide variety of HVAC and other building equipment. Somecontrollers use the BACnet /IP communications protocoland other controllers are switchable to use either the MS/TP or N2 communications protocol. Both the BACnet/IPcontrollers and the field controllers in MS/TP mode areBACnet network-compliant devices. Controllers running inN2 mode can be used to maintain or modernize sites withinstalled legacy Johnson Controls controllers.The FEC family of controllers integrate into the web-basedMetasys system, and include the following broad portfolioof controllers: Advanced Application Field Equipment Controllers(FACs) Field Equipment Controllers (FECs) Variable Air Volume Modular Assembly (VMA) VMA16series, VMA18 series and VMA1930 controllers Input/Output Modules (IOMs)The FAC, FEC, VMA16 (32-bit), VMA18, VMA1930, andIOM models feature an advanced design that providesoptimum performance and easy access to power, network,and field terminations. These controllers come with 32bit microprocessors to meet and exceed demandingindustry standards. Some FEC models include an intuitiveUI with an integral LCD screen and a 6-button navigationtouchpad that provides enhanced local monitoring ofcontrolled field equipment.The embedded capabilities of the VMA18 Controller, inaddition to its modular accessories, make it well suitedas a replacement for legacy VMA14xx Series Controllers.VMA16 (16-bit) Series Controllers are also part of thisfamily of controllers but cannot be configured as N2Controllers.For demanding environments, such as rooftopapplications, extended temperature range models areavailable that provide accurate control over a wideroperational temperature range. Look for the ET (ExtendedTemperature) suffix in the controller model.Devices in the Field Equipment Controller family integrateeasily with the NS Series Network Sensors, ZFR and ZFRPro Series Wireless Field Bus Systems, and WRZ SeriesWireless Sensors. The Field Equipment Controller familyalso supports the WRZ Series Wireless Sensors using theWRZ-78xx One-to-One Wireless Receiver. These productscomplement the FEC family of controllers and enableenhanced capabilities in both wired and wireless fieldcontroller network applications.Figure 1: Metasys System Field Equipment Controllers and Accessories

A wide variety of Johnson Controls network sensor modelsprovides options for measuring and displaying zonetemperature, duct temperature, zone humidity, carbondioxide level, setpoint adjustments, fan speed control, anddischarge air temperatures.The Wireless ZFR, ZFR Pro, and WRZ Series devices useopen wireless technology standards, including Institute ofElectrical and Electronic Engineers, Inc. (IEEE) 802.15.4 andmeshing technology, to provide flexibility and reliability.Features and benefits Large product family—Provides a wide range of pointmix to meet application requirements and allows forthe addition of one or more IOMs and Network Sensorsto provide even more I/O capacity. Standard hardware and software platform—Uses acommon hardware design throughout the family line tosupport standardized wiring practices and installationworkflows; also uses a common software design tosupport use of a single tool for control applications,commissioning, and troubleshooting to minimizetechnical training. Universal Inputs and configurable Outputs—Allowsmultiple signal options to provide input/outputflexibility. Auto-Tuned Control Loops—Reduce commissioningtime, eliminate change-of-season re-commissioning,and reduce wear and tear on mechanical devices. Patented proportional adaptive control (P-Adaptive)and PRAC—Provide continuous loop tuning. Standard BACnet Protocol—Provides interoperabilitywith other Building Automation System (BAS) productsthat use the widely accepted BACnet standard. BACnet Testing Laboratories (BTL) listed andcertified—Ensures interoperability with other BTL-listeddevices. BTL is a third-party agency, which validatesthat BAS vendor products meet the BACnet industrystandard protocol. Models to support communications protocols thatare switchable between BACnet MS/TP and N2—With Controller Configuration Tool (CCT) Release 10.1and later, FACs, FECs, and VMAs can be configured tocommunicate using either the BACnet MS/TP or the N2field bus networking protocol. The operation of the IOMis not affected by the selection of the BACnet MS/TP orthe N2 protocol in the host controller. Models to support BACnet/IP communications—The FAC4911 and the VMA1930 communicate overthe BACnet/IP protocol. This allows more flexibility inchoosing the devices for your site's network. ZFR Wireless FC or SA Bus Interface—Both the ZFRand ZFR Pro Series provide a wireless alternative tohard-wired Metasys system counterparts, offeringapplication flexibility and mobility with minimaldisruption to building occupants. Bluetooth Wireless Commissioning—Provides aneasy-to-use connection to the configuration andcommissioning tool. Optional Local User Interface Display—Allowsconvenient monitoring and adjusting capabilities at thelocal device.Network diagram with Field ControllersFigure 2: Metasys system with Field Equipment ControllersIntegration to the Metasys SystemSupervisory DevicesThe FEC family is designed to integrate seamlessly intothe Metasys system by connecting to, communicatingwith, and being supervised by Metasys network engines(including SNE, SNC, NAE, NIE, and NCE series network2engines). This seamless integration of field controllerswith Metasys delivers coordinated, system-wide controland enables building operators to monitor and adjustequipment controllers from the Metasys system UI.In addition, service personnel can view equipmentcontroller information locally through an optional localcontroller display (MS-DIS1710-0) available for equipmentMetasys System Field Equipment Controllers and Related Products Product Bulletin

controllers, or through the optional Mobile Access Portal(MAP) Gateway.Field Equipment Controller familyThe full range of FAC and FEC models combined with theIOM models can be applied to a wide variety of buildingapplications ranging from simple fan coil or heat pumpcontrol to advanced central plant management. Allcontrollers in the Metasys Field Equipment Controllerfamily run pre-engineered and user-programmedapplications and provide the I/O required to monitor andcontrol a wide variety of HVAC equipment.This large family of diverse field controllers is designed toinstall easily and communicate through standard RS485BACnet MS/TP protocol or BACnet/IP protocol, whichenables you to build an almost endless variety of fieldcontroller network applications, ranging from simplefan coil, heat pump, or VAV control applications to veryadvanced central plant management and stand-aloneapplications.Metasys Field Controller featuresFeatures and benefits common to the FAC, FEC, VMA16Series, VMA18 Series, VMA1930, and IOM devices includethe following: 32-bit Microprocessor—Ensures optimumperformance and meets industry specifications. BACnet automatic discovery—Supports easycontroller integration into a Metasys BAS. End-of-Line (EOL) switch in MS/TP Field Controllers—Enables field controllers to be terminating devices onthe communications bus. Pluggable Communications Bus and supplypower terminal blocks—Expedites installation andtroubleshooting. Wireless ZFR and ZFR Pro Series Wireless Field Bussystems in MS/TP Controllers—Enables wireless meshconnectivity to supervisory controllers, facilitating easyinitial location and relocation.Additional features and benefits common to FAC, FEC, andVMA field controllers include the following: Writable Flash Memory—Allows standard orcustomized applications to be downloaded from theCCT and enables persistent application data. Local UI Display—Provides enhanced local monitoring. User-friendly graphic theme and clear pushbuttonidentification—Facilitate easy navigation of theintegral or optional UI/display.Communications protocolsBy default, the Metasys system FEC Family Controllersand network sensors communicate using the standardBACnet protocol based on the ANSI/ASHRAE 135-2008.The BACnet protocol is a standard for ANSI, ASHRAE,and the International Standards Organization (ISO) forbuilding controls.FEC, VMA16, and VMA18 are BTL-listed as BACnetApplication Specific Controllers (B-ASCs). FAC FieldControllers and the VMA1930 Field Controller are BTLlisted as BACnet Advanced Application Controllers (B-AACs). The NS Series Sensors are BTL-listed as BACnetSmart Sensors (B-SSs).Release 10.1 and later of the Controller Configuration Tool(CCT) can be used to switch the Field Bus communicationsprotocol in supported FEC Family Field Controllers to beeither the standard BACnet MS/TP or the N2 protocol.All new controllers use either BACnet MS/TP or BACnet/IP as the default communications protocol. Switchablecommunications protocols in the MS/TP models providea cost-effective upgrade and modernization path forcustomers with existing N2 controllers.The Modernization Guide for Legacy N2 Controllers(LIT-12012005) and the controller-specific documentationprovide installation and commissioning support includingtips for efficient and safe replacement. For informationabout mapping N2 Objects in controllers with switchablecommunications protocols, refer to the N2 CompatibilityOptions chapter of the Controller Tool Help (LIT-12011147).The N2-capable FEC Family Controllers can be used asfunctional replacements for legacy N2 controllers. The N2capable FEC Family Controllers: have the input and output (I/O) quantities andcharacteristics of the FEC Family Controllers must be programmed with CCT support SA Bus devices support WRZ wireless sensors from the controller usingthe WRZ-7860 receiver (most models) are available in Buy American versions (most models) are listed for UL 864 UUKL/ORD-C100-13 UUKLC 10thEdition Smoke Control (some models). N2 is nowsupported as part of the Metasys 10th Edition listingfor Smoke Control System Equipment. For details, referto the Metasys System UL 864 10th Edition UUKL/ORDC100-13 UUKLC Smoke Control System Technical Bulletin(LIT-12012487).The N2-capable controllers: do not support Zone Bus (for example, TMZ sensorsand M100 actuators) or XT-Bus (System 91) devices (forexample, XT, XTM, and XP modules) do not support a wireless connection to the N2 bus do not support NxE passthroughHardware and installationMetasys field controllers are encased in a durable plastichousing. The plastic housing may eliminate the need for aseparate enclosure for plenum-rated construction. Checkspecific controller documentation and regional, national,and local code requirements for appropriate applications.Metasys field controllers feature bright, color-coded LEDs,visible on the controller cover, that indicate the supplypower, communications bus, and EOL switch status, aswell as a variety of fault conditions to aid troubleshootingthe controller and bus.An integral EOL switch on MS/TP field controllers allowsyou to enable the controller as a bus terminating device,which, when properly configured, reduces reflected noiseon the bus and improves bus communication.Each MS/TP field controller has an easily accessible eightposition DIP switch that allows you to set a valid andunique device address for each field controller on theMetasys System Field Equipment Controllers and Related Products Product Bulletin3

bus. A blank space is included on the controller cover forrecording the device address.The BACnet/IP field controllers feature rotary switchesto give each controller a unique number on the subnetwhere it resides, in order to identify it in the ControllerTool for uploading, downloading, and commissioning.The field controllers feature removable, color-coded,keyed, and labeled terminal block plugs for the supplypower and communications bus terminations. Mostmodels have fixed, color-coded, and labeled terminalblocks for the input and output terminations, whichfacilitate installing and servicing the controllers.The I/O terminations on the VMA models are spade lugs.Pluggable screw terminal blocks that connect to the I/Ospade terminations are available as optional accessories.FAC2612 models have removable, color-coded, andlabeled terminal block plugs for the I/O terminations.On FAC, FEC, and IOM Series Controllers, integralmounting clips and a DIN rail track on the controller backplate allow you to easily mount the field controller eitheron a horizontal section of 35 mm DIN rail or directly to awall or flat vertical surface.Some FEC models have a backlit user interface displaywith adjustable brightness and contrast to ensurereadability in low-light environments. The easy-touse display provides convenient local monitoring andadjusting of key setpoints and control parameters. Forthe FAC and FEC models without a display, a stand-aloneDIS1710 Local Controller Display module or MAP Gatewayare available that connect directly to the SA Bus port.For details, refer to the DIS1710 Local Controller DisplayProduct Bulletin (LIT-12011273) and the Mobile Access PortalGateway Product Bulletin (LIT-1201184).Advanced Application FieldEquipment controller (FAC)The Advanced Application Field Equipment Controller(FAC) Series Controllers are programmable controllersthat can communicate using BACnet/IP, MS/TP, orN2 communications protocols, depending on themodel. The FAC4911 is a BACnet Advanced ApplicationController (B-AAC) that communicates using BACnet/IPcommunications protocol. All other FAC Series controllerscan be switched between MS/TP and N2 communicationprotocols. FAC controllers used as MS/TP devices are BAACs with integral RS-485 MS/TP communications.FAC Series Controllers feature an integral real-time clock.FACs support time-based tasks and maintain time-basedcontrol, which enables these field controllers to monitorand control schedules, calendars, alarms, and trends.FACs can continue time-based control and monitoringwhen offline for extended periods of time from a Metasyssystem network.FAC Series Controllers can also operate as stand-alonecontrollers in applications that do not require a networkedsupervisory device or for network applications where itis preferred to have the scheduling, alarming, and/ortrending performed locally in the field controllers.The FAC4911 controllers operate on BACnet/IP networksand integrate into Johnson Controls and third-partysystems.The FAC3613 models include a fast persistence featurethat allows data values to be held at a configurable value,up to once per second. Persistence refers to how oftensamples of data are stored locally. In the event of aproblem, such as a loss of power, data can be retrievedup to the rate that the data is persisted, minimizing thepotential loss of data. When power is restored, previouslypersisted data, up to the rate of persistence, remainsavailable and accessible. For example, if persistenceis configured for once per second, you only risk losingone second of data. Persisting data may be essential forsituations that require greater data accuracy, includingcertain methods of utility data collection and billing.The FAC2612 controller features line-voltage relayoutputs, which makes this controller well-suited for use interminal units. The FAC2612-2 model uses a line-voltagepower supply, which eliminates the need for a 24 VACtransformer in line-voltage applications.The FAC2611, FAC2612, and FAC3613 controllers using theMS/TP protocol support wireless communications usingthe ZFR or ZFR Pro Series accessories and the WRZ-7860One-to-One Receiver.Important: You cannot purchase a similar thirdparty device and install it in a UL/cUL Listed smokecontrol system. Doing so voids the UL/cUL SmokeControl Listing. Third-party devices must be providedand labeled by the factory as described in the UL/cUL Smoke Control Listing.Important: Only those Johnson Controls productsidentified for use in smoke control applications havebeen tested and listed by UL for use in a Metasyssystem UL 864 10th Edition UUKL/ORD-C100-13UUKLC Smoke Control System. Installation of aproduct that is not UL/cUL Listed and labeled for thisapplication prevents the entire system from beingUL/cUL Listed for smoke control.FAC Series model information (Including point type counts)Note: The FAC2513 is only available in certainregions. Contact your local Johnson Controlsrepresentative for more information.4Metasys System Field Equipment Controllers and Related Products Product Bulletin

Table 1: FAC Series model information (Including point type ation protocolBACnet MS/TP, N2BACnet/IPEngines supportedAll Model types. Refer to the Network EnginesProduct Bulletin (LIT-12012138) for details.SNC, SNEOAS, NAEand ODS atRelease 9 orlater.6-pin SA Bus Modular Port supports one communicatingsensor. Or you can wire up to four communicating sensors tothe SA Bus Terminal Block. They cannot be used at the sametime.Modular jacks6-pin FC Bus for tool supportPoint typesSignals acceptedAnalog Input, Voltage Mode, 0–10VDCAnalog Input, Current Mode, 4–20mAUniversal Input(UI)4Analog Input, Resistive Mode, 0–2kCurrent6ohm, RTD (1k NI [Johnson Controls], Mode not1k PT, A99B SI), NTC (10k Type L,supported2.252k Type 2)58104666464Binary Input, Dry ContactMaintained ModeDry Contact Maintained ModeBinary Input (BI)Analog Output(AO)Pulse Counter/Accumulator Mode(High Speed), 100 HzAnalog Output, Voltage Mode, 0–10VDCAnalog Current Mode, 4–20 mA622Current2Mode notsupported2Binary Output(BO)ConfigurableOutput (CO)24 VAC TriacAnalog Output, Voltage Mode, 0–10VDCExternalPoweronly32444Binary Output Mode, 24 VAC TriacRO: Single-Pole, Double-ThrowRelay Output (RO) (SPDT)RO: Single-Pole, Single-Throw (SPST)2 - SPDTand 3 SPST linevoltagerelays, 1/4hp 120VAC, 1/2hp 240VACMetasys System Field Equipment Controllers and Related Products Product Bulletin5

Field Equipment Controller (FEC)The Field Equipment Controller (FEC) Series products areprogrammable controllers that can be switched betweenBACnet MS/TP and N2 communications protocols. Whenthey are used as BACnet MS/TP devices, they are BACnetApplication Specific Controllers (B-ASCs) with integralMS/TP communications. In N2 mode, they can be used tomodernize sites with legacy Johnson Controls controllers.FECs feature 32-bit microprocessor architecture, patentedcontinuous tuning adaptive control, and peer-to-peercommunications, and are available with an optional builtin LCD screen local UI.A full range of FEC models combined with the Input/Output Module (IOM) models can be applied to a widevariety of building applications ranging from simplefan coil or heat pump control to advanced central plantmanagement. All FEC Series Controllers configured forBACnet support wireless communications using the ZFRSystem accessories.Important: You cannot purchase a similar thirdparty device and install it in a UL/cUL Listed smokecontrol system. Doing so voids the UL/cUL SmokeControl Listing. Third-party devices must be providedand labeled by the factory as described in the UL/cUL Smoke Control Listing.Important: Only those Johnson Controls productsidentified for use in smoke control applications havebeen tested and listed by UL for use in a Metasyssystem UL 864 10th Edition UUKL/ORD-C100-13UUKLC Smoke Control System. Installation of aproduct that is not UL/cUL Listed and labeled for thisapplication prevents the entire system from beingUL/cUL Listed for smoke control.FEC Series model information (Including Point Type Counts)Note: The FEC2511 is currently only availablein Europe. Contact your local Johnson Controlsrepresentative for more information.Table 2: FEC Series model information (Including Point Type Counts)FEC2511FEC16

The NS Series Sensors are BTL-listed as BACnet Smart Sensors (B-SSs). Release 10.1 and later of the Controller Configuration Tool (CCT) can be used to switch the Field Bus communications protocol in supported FEC Family Field Controllers to be either the standard BACnet MS/TP or the N2 protocol. All new controllers use either BACnet MS/TP or .

Related Documents:

the design of the network as a whole, and you can use the Metasys IP Network wizard to guide you as you make some of these decisions. For more information on the design of Metasys IP networks, refer to the Metasys IP Networks for BACnet/IP Controllers Technical Bulletin (LIT-12012458). Cisco IE switch communication protocols

4 Metasys System Extended Architecture Graphics Stencil Library (GSL) Technical Bulletin Key Concepts Graphics Stencil Library Overview The Metasys system extended architecture Graphics Stencil Library (GSL) is a set of Visio Stencils, Templates, and add-ons (including Gzip, a compression utility), used with Microsoft Visio Professional

RabbitMQ Server 3.7.3 RabbitMQ is a service bus used to send notification messages to other services and is used for inter-process communication (messages) on the server. Set Rate Limits IIS module that applies rate limiting to Metasys API calls. This module and settings do not apply to SMP or MUI. 8 Metasys Server Installation and Upgrade .

LIT-12011694 2020-10-29 Release 11.0 Custom Dashboards for the Metasys User Interface. Custom dashboards enable Metasys UI designers to create dashboards that provide the most relevant and critical information to Metasys operators for enhanced

Extend building management capability with wireless sensors and controllers. . SQL Server database system, and industry-leading web browsers. Secure, encrypted data exchange between your mail client and the Metasys server or network . Use available options to achieve UL/cUL 864

Procedures Programming Manual, publication 1756-PM001. The term Logix5000 controller refers to any controller that is based on the Logix5000 operating system, such as: CompactLogix controllers ControlLogix controllers DriveLogix controllers FlexLogix controllers SoftLogix5800 controllers

Common Procedures Programming Manual, publication 1756-PM001. The term Logix5000 controller refers to any controller that is based on the Logix5000 operating system, such as: CompactLogix controllers ControlLogix controllers DriveLogix controllers FlexLogix controllers SoftLogix5800 controllers

The Python programming language is a recent, general-purpose, higher-level programming language. It is available for free and runs on pretty much every current platform. This document is a reference guide, not a tutorial. If you are new to Python programming, see the tu-torial written by Guido van Rossum . 3, the inventor of Python. Not every feature of Python is covered here. If you are .