Instruction ManualPN 5102120/rev.AApril 1998Model T/T 1054-A2100Turbidity Systems

ESSENTIALINSTRUCTIONSWARNINGELECTRICAL SHOCK HAZARDREADTHISPAGEBEFOREPROCEEDING!Rosemount Analytical designs, manufactures, and tests itsproducts to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and maintainthem to ensure they continue to operate within their normalspecifications. The following instructions must be adheredto and integrated into your safety program when installing,using, and maintaining Rosemount Analytical products.Failure to follow the proper instructions may cause any oneof the following situations to occur: Loss of life; personalinjury; property damage; damage to this instrument; andwarranty invalidation.Making cable connections to and servicing this instrument require access to shock hazard level voltageswhich can cause death or serious injury.Relay contacts made to separate power sourcesmust be disconnected before servicing.Electrical installation must be in accordance withthe National Electrical Code (ANSI/NFPA-70)and/or any other applicable national or local codes. Read all instructions prior to installing, operating, andservicing the product. If this Instruction Manual is not thecorrect manual, telephone 1-800-654-7768 and therequested manual will be provided. Save this InstructionManual for future reference.Unused cable conduit entries must be securelysealed by non-flammable closures to provideenclosure integrity in compliance with personalsafety and environmental protection requirements. If you do not understand any of the instructions, contactyour Rosemount representative for clarification.For safety and proper performance this instrumentmust be connected to a properly grounded threewire power source. Follow all warnings, cautions, and instructions markedon and supplied with the product. Inform and educate your personnel in the proper installation, operation, and maintenance of the product. Install your equipment as specified in the InstallationInstructions of the appropriate Instruction Manual andper applicable local and national codes. Connect allproducts to the proper electrical and pressure sources. To ensure proper performance, use qualified personnelto install, operate, update, program, and maintain theproduct. When replacement parts are required, ensure that qualified people use replacement parts specified byRosemount. Unauthorized parts and procedures canaffect the product’s performance and place the safeoperation of your process at risk. Look alike substitutions may result in fire, electrical hazards, or improperoperation. Ensure that all equipment doors are closed and protective covers are in place, except when maintenance isbeing performed by qualified persons, to prevent electrical shock and personal injury.Emerson Process ManagementRosemount Analytical Inc.2400 Barranca ParkwayIrvine, CA 92606 USATel: (949) 757-8500Fax: (949) 474-7250http://www.RAuniloc.com Rosemount Analytical Inc. 2001Proper relay use and configuration is the responsibility of the user.Do not operate this instrument without front coversecured. Refer installation, operation and servicingto qualified personnel.DANGER HAZARDOUS AREAINSTALLATIONInstallations near flammable liquids or in hazardous arealocations must be carefully evaluated by qualified on sitesafety personnel. This sensor is not intrinsically Safe,Explosion, or is designed for Hazardous Area Installation.CAUTION SENSOR/PROCESSAPPLICATION COMPATIBILITYThe wetted sensor materials may not be compatible withprocess composition and operation conditions. Application compatibility is entirely the responsibility of the user.

NOTES1.See text for wiring details.Power requirements: 120/240 VAC, 50/60 Hz, 11 watts. Make certain available line voltage matches instrument nomenclature voltage specification.Three conductor type SJT 18 AWG minimum recommended for power cable.Shielded cable 22-24 AWG recommended for output circuits.Alarm contacts rated 240 volts, 5 amps. Contacts normally open.20 feet of cable is supplied as standard with sensor. Sensors with customcable should not be extended beyond 50 feet.7.Signal wiring connected to this instrument must be rated at least 240 VAC.8.Non-metallic enclosure does not provide grounding between conduit connections. Use grounding type bushings and jumper wires.FIG. 2-3. Terminal Wiring Diagram188

WARRANTYGoods and part(s) (excluding consumables) manufactured by Seller are warranted to be free from defects in workmanship and material under normal use and service for a period of twelve (12) months from the date of shipment by Seller.Consumables, pH electrodes, membranes, liquid junctions, electrolyte, O-rings, etc. are warranted to be free from defectsin workmanship and material under normal use and service for a period of ninety (90) days from date of shipment by Seller.Goods, part(s) and consumables proven by Seller to be defective in workmanship and / or material shall be replaced orrepaired, free of charge, F.O.B. Seller's factory provided that the goods, parts(s), or consumables are returned to Seller'sdesignated factory, transportation charges prepaid, within the twelve (12) month period of warranty in the case of goodsand part(s), and in the case of consumables, within the ninety (90) day period of warranty. This warranty shall be in effectfor replacement or repaired goods, part(s) and consumables for the remaining portion of the period of the twelve (12)month warranty in the case of goods and part(s) and the remaining portion of the ninety (90) day warranty in the case ofconsumables. A defect in goods, part(s) and consumables of the commercial unit shall not operate to condemn such commercial unit when such goods, parts(s) or consumables are capable of being renewed, repaired or replaced.The Seller shall not be liable to the Buyer, or to any other person, for the loss or damage, directly or indirectly, arisingfrom the use of the equipment or goods, from breach of any warranty or from any other cause. All other warranties,expressed or implied are hereby excluded.IN CONSIDERATION OF THE STATED PURCHASE PRICE OF THE GOODS, SELLER GRANTS ONLY THE ABOVESTATED EXPRESS WARRANTY. NO OTHER WARRANTIES ARE GRANTED INCLUDING, BUT NOT LIMITED TO,EXPRESS AND IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.RETURN OF MATERIALMaterial returned for repair, whether in or out of warranty, should be shipped prepaid to:Rosemount Analytical Inc.Uniloc Division2400 Barranca ParkwayIrvine, CA 92606The shipping container should be marked:Return for RepairModelThe returned material should be accompanied by a letter of transmittal which should include the following information(make a copy of the "Return of Materials Request" found on the last page of the Manual and provide the following thereon):1. Location type of service, and length of time of service of the device.2. Description of the faulty operation of the device and the circumstances of the failure.3. Name and telephone number of the person to contact if there are questions about the returned material.4. Statement as to whether warranty or non-warranty service is requested.5. Complete shipping instructions for return of the material.Adherence to these procedures will expedite handling of the returned material and will prevent unnecessary additionalcharges for inspection and testing to determine the problem with the device.If the material is returned for out-of-warranty repairs, a purchase order for repairs should be enclosed.

The right people,the right answers,right now.ON-LINE ORDERING NOW AVAILABLE ON OUR WEBSITE http://www.RAuniloc.comCredit Cards for U.S. Purchases Only.Emerson Process ManagementRosemount Analytical Inc.2400 Barranca ParkwayIrvine, CA 92606 USATel: (949) 757-8500Fax: (949) 474-7250http://www.RAuniloc.com Rosemount Analytical Inc. 2001

servicing the product. If this Instruction Manual is not the correct manual, telephone 1-800-654-7768 and the requested manual will be provided. Save this Instruction Manual for future reference. If you do not understand any of the instructions, contact your

Related Documents:

i) MicroScan Turbidity Meter (Dade International, Inc.): Zero the instrument with sterile BHI. Vortex the cell suspension and measure in the turbidity meter. Adjust turbidity of culture with sterile BHI to turbidity reading 1.1 1.3. OR ii) Spectrophotometer: Set wavelength to 610 nm, and zero the instrument with BHI.

needed is in the collection and management of turbidity data. The Importance of Turbidity Data Turbidity data is a part of the compliance record for the water treatment plant. Because the SWMOR is a legal document, when it is signed by a licensed operator, the operator is certifying the accuracy of the data in the report.

Guidance Manual for Compliance with the vii Surface Water Treatment Rules: Turbidity Provisions . NTNCWS Non-Transient Non-Community Water System . NTU Nephelometric Turbidity Units . OSHA Occupational Safety and Health Administration . PAC Powdered Activated Carbon . PBT Perfo

Statistical Analyses - YSI EXO and YSI 6136 Data Slope comparison The following is a summary of final regression analysis for sensor-measured turbidity from a YSI EXO turbidity sensor and a YSI 6136 turbidity sensor at the Kansas Water Science Center laboratory, Lawrence, Kansas, on Febr

Colley and Smith (2001) recommend abandonment of turbidity monitoring in favor of a more reproducible parameter—beam attenuation. However attenuation devices are non-linear and work best when turbidity is less than about 100 attenuation units (personal communication; John Downing, President,

Operational Pressure Rating Regulation Dimension (LxWxH) Cable Length 532590 Turbidity .00-1,000.00 NTU (Nephelometric Turbidity Unit) 0.5NTU 2NTU or 2% of the Value 2NTU or 3% of the Value 0.1NTU T95 12 seconds Field Tested Process Sample or Formazine Calibration Standard Warm White Light 100NTU or Infrared Light 100NTU Scattering 22 .

Jar Testing Experiment Tested two different coagulants: Ferric Chloride (Ferric) Aluminum Sulfate (Alum) Measured Parameters Raw Water: o Alkalinity o pH o TOC o Turbidity o UV Settled Water: o TOC o Turbidity o UV Goal: To investigate how turbidity, UV, and TOC all were influenced by different coagulant dosages

Turbidity values of 2-200 NTU can be measured, but frequent cleaning may be required to maintain turbidity measurements. Cable 20 ft. (6.1 m) or 50 ft. (15.2 m). Maximum 50 ft. (15.2 m). Connector is IP65. Maximum pressure 30 psig (308 kPa) Temperature 40 to 95 F (5 to 35 C) Sensor body rating IP65 when cable is connected. Debubbler and .