APCVAU1605WarningAsk a qualified installer or contractor to install this product. Do not try to install the product yourself.Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer orcontractor to install those parts and accessories. Use of unauthorised parts and accessories orimproper installation of parts and accessories can result in water or refrigerant leakage, electricalshock, fire or explosion.Read the user's manual carefully before using this product. The user's manual provides importantsafety instructions and warnings. Be sure to follow these instructions and warnings.If you have any enquiries, please contact your local importer, distributor and/or retailer.Cautions on product corrosion1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to installthe outdoor unit close to the sea shore, contact your local distributor.S SERIESFor residential and commercial useSpecifications, designs and other content appearing in this brochure are current as of May 2016 but subject to change without notice.c All rights reservedY.K.Heat Pump 50 Hz

Engineered for FlexibilityFirst launched in Japan in 1982, the Daikin VRV system has beenembraced by world markets for over 30 years. Now, Daikin proudlyS SERIESVRV indoor units combine withresidential indoor units, all in one system.introduces the new VRV IV S series-the ideal air conditioning systemfor homes, shops and offices.BP unitMax.14indoorunitsResidential indoor unitsVRV indoor units* VRV is a trademark of Daikin Industries, Ltd.ContentsMain FeaturesIndoor Unit LineupSpecificationsOption ListControl SystemsAir Treatment Equipment LineupP03P09P37P51P57P69OFFICESSHOPS01HOMES02

Main FeaturesCompact & lightweight designEnhanced lineupThe new design has been optimised for the VRV IV S series, with the height of 3.5 class to 5 class models reduced toonly 990 mm. This design gives the building a sleek look externally and provides the occupants with a clear,unobstructed view of the scenery. The VRV IV S series is now slim and compact, with outdoor units that require minimalinstallation space.VRVS SERIESS4, 5 class3.5, 4, 5 class1,345mm990mm320mm320mmTo suit a variety of room sizes, VRV IV S series expands our range to include 3.5 class,8 class and 9 class.S SERIESMo/C*VRVS SERIES4 classS (11.2 kW)4 class(11.2 kW)Height1,345 mmHeight990 mm26%DecreaseProductWeight125 kgProductWeight71 kg43%Decrease3.5 classMo/C*Mo/C*4 class5 class6 class8 class9 class*Mo/C represents Model ChangeLineupS SERIES1,657mm1,430mm930mm765mm940mmS SERIES8 class(22.4 kW)8 class8 class8 class(22.4 kW)Height1,657 mmHeight1,430 mmProduct Weight185 kgProduct Weight138 kgDecreaseFootprint0.71 m2Footprint0.30 m258%Decrease320mm14%6 modelsModel NameRXYMQ3AV4ARXYMQ4AV4APower SupplyRXYMQ5AV4ARXYMQ6AV4A1-phase, 230 – 240 V, 50 HzRXYMQ8AY1RXYMQ9AY13-phase, 380 – 415 V, 50 HzDecreaseCapacity Range3.5 class(9.0 kW)4 class(11.2 kW)5 class(14.0 kW)6 class(16.0 kW)8 class(22.4 kW)9 class(24.0 kW)25%Capacity Index80100125150200215Wide variety of indoor unitsIndoor units can be selected from 2 lineups, both VRV and residentialindoor units, to match rooms and preferences. A mixed combination ofVRV indoor units and residential indoor units can be included into onesystem, opening the door to stylish and quiet indoor units.External view ofa condominiumInternal view of acondominium unit03Elegant appearance withEuropean styleCTXG-P series indoor unit04

Main FeaturesEnergy savingHigher Coefficient of Performance (COP)Collection of cutting-edge technologies realises efficient and quiet operationVRV IV S series provides greater energy saving as compared to VRV III S series, especially for 6 class.The high efficiency compressor to achieve a higher COP12%Increase43.83.63.43.203.693.5 class(9.0 kW)VRV3.803.893.863.564 class(11.2 kW)5 class(14.0 kW)6 class(16.0 kW)3.778 class(22.4 kW)Daikin DC inverter models are equipped with the Reluctance DC motor forcompressor. The Reluctance DC motor uses 2 different types of torque, neodymiummagnet*1 and reluctance torque*2. This motor can save energy because it generatesmore power with a smaller electric power than an AC or conventional DC motor.3.49Motor efficiency (%)CoolingOperationCOP9 class(24.0 kW)*Cooling operation conditions: Indoor temp. of 27ºCDB,19ºCWB, and outdoor temp. of 35ºCDB.SS SERIES80Conventional DC motor70More than 20%60AC motor030*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.*3. In case of 4 class outdoor unit during cooling operation05Capacity %Load %Operation sound dB(A)Combinations of modes 1 and 2 can be useddepending on your needs.120Large loadHigh capacityUse of an optimised sine wave smoothes motor rotation, further improving operating efficiency.RXYMQ3, 4, 5, 6AV4AMode 1. Automatic modeMode 2. Manual modeMode 3. Combined mode901 Smooth sine wave DC inverterOperation sound level selectable from 3 steps for the night modeStarting time and ending time can be input. (Anexternal control adaptor for outdoor unit,DTA104A53/61/62, and a locally obtained timer arenecessary.)60ReluctanceDC motorNote: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.*1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.*2 The torque created by the change in power between the iron and magnet parts.Sine wave DC inverterNighttime quiet operation functionSet on the outdoor PCB. Time of maximumtemperature is memorised. The low operating modewill initiate 8 hours*1 after the peak temperature inthe daytime, and normal operation will resume 10hours*2 after that. The operation sound level for thenight mode can be selected from 49 dB(A) (Step 1),46 dB(A) (Step 2) and 43 dB(A) (Step 3).*32Rotational speed (rps)Small loadLow capacityQuiet operation3Reluctance DC motor9050Mode 1. Automatic mode8, 9 Class1 Compressor equipped with Reluctance DC motor100Peak in outdoor temperature8 hrs10 hrs(Initial setting)50(Initial setting)052Night ModeStep 1 max. - 3 dB(A)Step 1: 49 dB(A)Step 2 max. - 6 dB(A)Step 2: 46 dB(A)43Step 3 max. - 9 dB(A)Step 3: 43 dB(A)8:00Night mode starts12:0016:0020:000:004:00 The structural scrollDaikin swing compressor has integrated therotor with the blade, completely solving therefrigerant leakage and the wear problemcaused by the mechanical friction between therotor and the blade, which enhances thecompressor efficiency and makes thecompressor more quiet and durable.Sucked gas iscompressed in theScroll sectionscrolling part before theDischarge Motor sectionheated motor, so thatthe machine compressthe non-expanded gas,resulting in high efficiency compression.These two features work to reduce sound. Guides are added tothe bell mouth intake to reduce turbulence in the airflow generatedby fan suction. The Aero Spiral Fan features fan blades with thebent blade edges, further reducing turbulence.Night mode endsRXYMQ8, 9AY1 Swing compressor2 Smooth Air Inlet Bell Mouth and Aero Spiral Fan49463.5, 4, 5 ClassWith the bentblade edgeWithout the bentblade edgeSuction3 DC fan motorEfficiency improved in all areascompared to conventional ACmotors, especially at low speeds.DC fan motor structure8:00Note: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in thegraph is just an example.The capacity reduction rate differs depending on the operation sound level step selected.Escaping eddies are sucked in bythe bent blade edges, reducingoverall turbulence.06

Main FeaturesDesign flexibility and simplified installationLong piping design possibleConnectable up to 14 indoor unitsLong piping length offers flexibility in the choice of installation positions, and simplifies system planning.As many as 14 indoor units can be connected to a single outdoor unit, making the VRV IV S series a remarkablyversatile system.When only VRV indoor units are connectedNote: Refer to page 49 for the maximum number of connectable indoor unit.aActual piping lengthMax.14Max.indoorunits120 mMax.BP unitceFirst indoor branchTotal piping lengthBP unitbdgfhiMax.50 m k300 mMax.j15 mResidential indoor unitsMax. allowable pipinglengthVRV indoor unitsMax. allowable leveldifferenceAutomatic test operationSimply press the test operation button and the unit performs an automatic system check, including wiring, stop valves,piping, and refrigerant charging amount. The results are returned automatically after the check finishes.Simple wiring and piping connectionDaikin’s advanced REFNET piping systemmakes installation easy. Only two mainrefrigerant lines are required in any onesystem. REFNET greatly reduces theimbalances in refrigerant flow betweenunits, while using small-diameter piping.Between the first indoor branch and the farthest indoor unit5 class6 class8,9 class50 m70 m120 m100 ma b c d e f g h i250 m300 m300 m300 mb c d i40 m40 m40 m40 mj10 m15 m15 m15 mk30 m30 m50 m50 m30 m30 m40 m40 mIf the outdoor unit is aboveIf the outdoor unit is belowkWhen a mixed combination of VRV and residential indoor units is connected orwhen only residential indoor units are connectedMax.Max.100 m250 mbaFirst indoor branchMax.50 mlCentralremotecontrolleredgfRAoMax.iRAOutdoor unitcBPhnBPjVRVMax.RA15 m15 mkMax.40 mmVRVRAIndoor unitMax. allowable pipinglengthMax. & min.allowable pipinglengthMin. allowable piping lengthMax. allowable leveldifferenceRefrigerant piping lengthTotal piping lengthThe first indoor branch - the farthest BP or VRV indoor unit3.5,4 class5 class6-9 classa b c g k, a b c d50 m70 m100 ma b c d e f g h i j k250 m250 m250 mb c g, b c d40 m40 m40 m2 m–15 m2 m–15 m2 m–15 m2 m–12 m2 m–12 m2 m–12 m2 m–8 m2 m–8 m2 m–8 mIf indoor unit capacity index 60BP unit - indoor unitIf indoor unit capacity index is 60h, i, j, kIf indoor unit capacity index is 71Outdoor unit - the first indoor brancha5m5m5mBetween the indoor unitsl10 m15 m15 m10 m15 m30 m50 mn30 m30 m40 mo30 m30 m40 mmBetween BP unitsOutdoor unit - the indoorunitOutdoor unit - the BP unit073.5,4 classa b c d iBetween the indoor unitsBetween the outdoor unitand the indoor unitTotal piping length Super wiring system REFNET piping systemTotal piping lengthActual piping lengthUnique piping and wiring systems make it possible to install a VRV IV S series quickly and easily.A super wiring system is used to enableshared use of the wiring between indoorand outdoor units and the central controlwiring, with a relatively simple wiringoperation.The DIII-NET communication system isemployed to enable the use of advancedcontrol systems.Refrigerant piping lengthIf the outdoor unit is aboveIf the outdoor unit is belown30 m15 m08

Indoor Unit LineupEnhanced range of choicesA mixed combination of VRV indoor units and residential indoor units can be included intoone system, opening the door to stylish and quiet indoor units.VRV indoor unitsType17 types 97 models20Model Name Capacity Range(kW) 2.2Capacity Index 202532 402.8 3.6 4.525 31.25 40505.650637.162.5718718098010011.210012514125140 14516 16.2140 145180 20020 22.4180 20025028250Residential indoor units with connection to BP unitsTypeModel NameCeiling MountedCassette(RoundFlow with Sensing)FXFQ-SVMCeiling MountedCassette(Round Flow)FXFQ-PVECeiling MountedCassette(Compact Multi Flow)FXZQ-MVEFDXS-CVMA4-Way FlowCeiling SuspendedFXUQ-AVEBCTXG-PVMAWCeiling MountedCassette(Double Flow)FXCQ-MVECeiling MountedCassette CornerFXKQ-MAVESlim CeilingMounted Duct(Standard Series)Slim CeilingMounted DuctFXDQ-PBVEFXDQ-NBVESlim CeilingMounted Duct(Compact Series)FXDQ-SPV1Middle StaticPressure CeilingMounted DuctFXSQ-PVECeiling Concealed(Duct)Ceiling MountedDuctCeiling MountedCassette(Compact Multi Flow)10 types 29 models202535506071Rated Capacity (kW)2.02.53.55.06.07.1Capacity Index202535506071FFQ-BV1BCDXS-EAVMA(700 mm width type)(900/1,100 mm width type)CTXG-PVMASWall MountedFTXS-KVMAFTXS-KAVMA(700 mm width type)Floor StandingFVXS-KV1A(900/1,100 mm width type)Floor/CeilingSuspended DualFLXS-BVMAFLXS-GVMANote: BP units are necessary for residential indoor units.FXDYQ-M(A)V1FXMQ-PVEVRV indoor units combine with residential indoor units, all in one system.FXMQ-MAVECeiling SuspendedWall MountedFloor StandingConcealedFloor Standing09BP idential indoor unitsVRV indoor units*Refer to page 49 for the maximum number of connectable indoor units.FXNQ-MAVE10

Indoor Unit LineupDaikin offers a wide range of indoor units including both VRV and residential models which respond to the variety ofneeds of our customers that require air conditioning solutions.Ceiling Mounted Duct TypeCeiling Suspended TypeFXHQ-MAFXMQ-PVRV indoor unitsCeiling Mounted Cassette(Round Flow with Sensing) TypeFXFQ-SPresence of people and floortemperature can be detected toprovide comfort and energy savingsFXMQ-MACeiling Mounted Cassette(Round Flow) TypeHigh external static pressureallows flexible installationsSlim body with quiet and wideairflowWall Mounted TypeFloor Standing TypeFXFQ-P360 airflow improves temperaturedistribution and offers acomfortable living environmentFXAQ-PFXLQ-MAConcealed Floor Standing TypeFXNQ-MACeiling Mounted Cassette(Compact Multi Flow) TypeFXZQ-M4-Way Flow CeilingSuspended TypeStylish flat panel designharmonised with your interiordécorSuitable for perimeter zone airconditioningFXUQ-AResidential indoor units with connection to BP unitsQuiet, compact, and designed foruser comfortThis slim and stylish indoor unitachieves optimum air distribution,and can be installed without theneed for ceiling cavityCeiling Mounted Cassette(Double Flow) TypeCeiling Mounted CassetteCorner TypeCeiling Mounted Cassette(Compact Multi Flow) TypeFFQ-BSlim Ceiling Mounted Duct TypeCDXS-EAFDXS-CFXCQ-MFXKQ-MAQuiet, compact, and designedfor user comfortSlim and smooth design suitsyour shallow ceilingWall Mounted TypeFloor Standing TypeCTXG-PThin, lightweight, and easy to install innarrow ceiling spacesSlim design for flexible installationFVXS-KFTXS-KFTXS-KASlim Ceiling Mounted Duct Type(Standard Series)FXDQ-PBSlim Ceiling Mounted Duct Type(Compact Series)FXDQ-SPFXDQ-NBSlim and compact design for easy andflexible installationMiddle Static Pressure CeilingMounted Duct TypeCeiling Concealed(Duct) TypeMiddle external static pressureand slim design allow flexible installations11Dual discharges to evenlydistribute air across the whole roomFloor/Ceiling SuspendedDual TypeFLXS-BSlim design, quietness andstatic pressure switchingFXSQ-PStylish flat panel harmoniseswith your interior décorFLXS-GFloor/ceiling dual usemaximises free spaceFXDYQ-M(A)High static pressure offers flexibleduct design that blends in with anyinterior décor in stores and offices12

Indoor Unit LineupVRV Indoor UnitsCeiling Mounted Cassette (Round Flow with Sensing) TypeSensing functionDraft prevention functionDryCoolingHeatingWhen human presencenot detected.FXFQ25S / FXFQ32S / FXFQ40SAuto airflow direction mode(default: OFF) *1. 2When human presencedetected.When human presencenot detected.When human presencedetected.FXFQ50S / FXFQ63S / FXFQ80SFXFQ100S / FXFQ125SSwingPresence of people and floor temperature can bedetected to provide comfort and energy savingsSwingBlown horizontallyWith the Auto airflow direction mode, flaps arecontrolled to deliver optimal air distribution for both coolingand heating operations when there are no people.Blown downwardBlown downward Blown horizontallyWhen a person is detected, drafts are prevented bymaking the flap horizontal.When a person is not detected for 5 minutes, the unit automatically returns to controlling the flaps for an unoccupied room.*1.Airflow direction shoud be set to Auto.*2.Draft prevention function is OFF in the initial setting. It can be set ON using the remote controller.Auto airflow direction mode Auto airflow rate modeComfort and Energy saving preventing over Cooling / Heating *1. 2Detecting thepresence ofpeople in 4 areasBCCoolingFloor temperature is detected and over cooling prevented.Without sensing functionDWith sensing functionA30 C near ceilingRoomtemperature isdetected as30 C.Detecting the averagetemperature of indoor floor20 C near floorIndoor unit offers 360 airflow discharges air in alldirections with more uniform temperature distribution.Individual airflow direction controlThanks to the individual airflow direction controlfunction, airflow direction can be individually adjustedfor each air discharge outlet to prevent uncomfortabledrafts and to deliver optimal air distribution.Infrared presence sensorThe sensor detects human presence and adjusts theairflow direction automatically to prevent drafts.Ceiling height2.7m3.5m4.0mapprox. approx. approx.Detection range8.5m11.5m13.5m*1. The infrared presence sensor detects 80 cm above the floor.(diameter)*1Infrared floor sensorThe sensor detects the floor temperature and automaticallyadjusts operation of the indoor unit to reduce thetemperature difference between the ceiling and the floor.Ceiling height2.7m3.5mapprox. approx.Detection range (diameter) *211m14m*2. The infrared floor sensor detects at the floor surface.134.0mapprox.16mEnergysavingsArea around feet getstoo cold because airconditioner continuesuntil the temperaturenear the ceiling reachesthe set temperature.Without sensing functionDrafts areminimal, but feetget cold.17 C near floorWith sensing functionArea near floor doesn’t reach settemperature and feet feel cold.For this reason, we end upraising the temperature setting.20 C near floorIn order toreduce drafts,air is blownhorizontallywhere aperson islocated.*2When air is blown downward.850 mmFeet arewarm, but draftis strong.Selectable airflow rate: 3 steps and Auto.(Auto airflow rate is available when BRC1E62 is used.)An antibacterial treatment that uses silverions has been applied to the drain pan,preventing the growth of slime, mould andbacteria that cause blockages and odours.(The lifespan of the cartridge dependson the usage environment, but should bechanged once every two to three years.)Automatic control using thetemperature near the personas the room temperature.Feet get cold, because warmair collects near the ceiling.Improved energy efficiency thanks to a new heatexchanger with smaller tubes, DC fan motor, and DC drainpump motor.Drain pump is equipped as standardaccessory with 850 mm lift.24 C near floorFeet are kept warm and comfortable while reducing uncomfortable drafts.When air is blown horizontally.Low operation sound levelRoom temperature iscalculated as 27 C in the area whichis in the vicinity of the person.The floor temperature,which is lower than nearthe ceiling, is detected.The temperature near the person is automatically calculated by detecting the temperature of the floor. Energy issaved, because the area around the feet does not get too cold.HeatingDead spot of airflow30 C near ceiling20 C near floorEnergysavingsUncomfortable draft occurs,because air is blown downward.To avoid draft, air direction ischanged to horizontal and feetget cold.The floor temperature, which is lower, is detected andwarm air is blown downward where no personis present.Comfortable because draft is reduced and area aroundfeet is warm.The tendency of people to raise the temperature too much is prevented, because you are warmed upfrom the feet.To increase comfort, Auto airflow rate mode controls the airflow in accordance withthe difference between floor and ceiling temperatures.When there is a large difference between the ceiling and floor temperatures, the airflow rate is automatically increased.When the difference becomes small, the airflow rate is automatically reduced.*1.Both airflow direction and airflow rate shoud be set to Auto.*2.Draft prevention function is set OFF in the initial setting.14

Indoor Unit LineupVRV Indoor UnitsCeiling Mounted Cassette (Round Flow with Sensing) TypeIndividual airflow settingSensing sensor mode*1.2Sensing sensor low mode (default: OFF)Airflow direction of each of the four air outlets can be controlled individually.(Positions 0 to 4, Swing, Blocked, and No individual setting are selectable.)When there are no people in a room, the set temperatureis shifted automatically.The system automatically saves energy bydetecting whether or not the room isoccupied. The set temperature is shiftedautomatically if the room is unoccupied.Setpoint ( )Example28272627 26 Setpoint ( )201918Occupied26 Automaticallyreverts whenpeople return.TimeIf people do not return, theair conditioner will raise thetemperature 1 every 30minutes and then operateat 30 .134 SwingPosition 2Outlet mark20 18 After another 30 minAutomaticallyreverts whenpeople return.If people do not return, theair conditioner will lowerthe temperature 1 C every30 minutes and thenoperate at 16 C.TimeShift temperature and time can be selected from 0.5 to 4 in 0.5 increments and 15, 30, 45, 60, 90 or 120 minutesrespectively with remote controller.Sensing sensor stop mode (default: OFF)When there are no people in a room, the system stops automatically.*3The system automatically saves energy by detecting whether ornot the room is occupied.Based on preset user conditions, the system automatically stopsoperation if the room is unoccupied.Airflow block function*1Total comfort by individual airflow direction control and “airflow block function”The system automatically saves energy by detectingwhether or not the room is occupied. The set temperatureis shifted automatically if the room is unoccupied.Airflow blockair velocityapprox. 0.3m/s*1Airflow block function prevents uncomfortable drafts byreducing air velocity.It can be set using the BRC1E62 remote controller. There is noneed for sealing material of air discharge outlet (option).This function only works when all-round flow is used. It cannotbe used when sealing material is used in the air dischargeoutlet (option).Airflow block function prevents uncomfortable drafts by reducing air velocity toapprox. 0.3m/s.*2Airflow blockfor cabinet sideEasy setup with remote controllerAirflowblockHorizontal flow*1.These functions are not available when using the group control system.*2.User can set these functions with remote controller.*3.Please note that upon re-entering the room, air conditioner will not switch on automatically.Also can supportsuch caseThe airflow block functionis useful when rearrangingthe room layout.Absent stop time can be selected from 1 to 24 hrs in 1 hr incrementswith remote controller.153 Position 2Swing4UnoccupiedAfter 30 minA28 After another 30 min19 (Auto direction)No ind. set Heating setpoint: 20 C Shift temperature: 1.0 C Shift time: 30 min. Limit heating temperature: 16 C20 No individual2 settingblocked2UnoccupiedAfter 30 minExample1 BlockedOperation isreduced in placeswhere there areno people. Cooling setpoint: 26 Shift temperature: 1.0 Shift time:30 min. Limit cooling temperature:30 OccupiedExampleIndividual airflow direction controlAirflow block500 mm*3Wall*1. Works in one direction only.*2. In case of FXFQ63S type (Data is based on Daikin research.) When using FXFQ80S type or higher, if the airflow rate is set to High, airflow will be on the high side.Under actual conditions, however, the airflow value may differ depending on the effect of surrounding conditions and the way in which the temperature was adjusted.*3. A gap of 1500 mm is required if the air block function is not used.16

Indoor Unit LineupVRV Indoor UnitsCeiling Mounted Cassette (Round Flow) TypeCeiling Mounted Cassette (Compact Multi Flow) TypeFXFQ25P / FXFQ32P / FXFQ40PFXZQ20M / FXZQ25M / FXZQ32MFXFQ50P / FXFQ63P / FXFQ80PFXZQ40M / FXZQ50MFXFQ100P / FXFQ125P360 airflow improves temperature distributionand offers a comfortable living environment.The industry’s first* Round Flow Ceiling MountedCassette type offers 360 airflow with improvedtemperature distribution.4-way flowQuiet, compact, and designed for user comfortDimensions correspond with 600 mm X 600 mmarchitectural module ceiling design specifications.Low operation sound level(240 V)(dB(A))FXZQ-M20/25324050Sound Round FlowComfortable airflowThere are areas ofuneven temperature.There are much fewerareas of uneven temperature.1Wide discharge angle: 0 to 60 Auto swing* As of April 2004, the release date for Japan.The light weight unit at 19.5 kg for FXFQ25-50Pmodels makes installation easy.Drain pump is equipped as astandard accessory with a 850 mmlift.A modern sophisticated decoration panel has beenapplied, with a panel surface that has been treated witha dirt-repellant coating.Treated surfaceResistssoilingUntreated surfaceDirt andgrime Condition afterexposure to thesmoke of 6003cigarettes in 1 menclosed space.Control of the airflow rate can be selected from 3-stepcontrol.Low operation sound levelThe horizontal louvres prevent dew condensation.Their non-flocking surfaces, which repel dirt, areeasy to clean.Example of airflow patterns:0 850 mmAll-round flow60 An antibacterial treatment that uses silver ions hasbeen applied to the drain pan, preventing the growthof slime, mould and bacteria thatcause blockages and odours.(The lifespan of the cartridge dependson the usage environment, but shouldbe changed once every two to threeyears.)The air filter has an anti-mould and antibacterialtreatment that prevents the growth of mouldgenerated from dust or moisture that may adhere tothe filter.4-way flow3-way flow60 Fixed angles: 5 levels0 0 60 Drain pump is equipped as standard accessory with750 mm lift.60 *Angles can be also set on site to prevent drafts (0 -35 )or soiling of the ceiling (25 -60 ), other than standard setting (0 -60 ).22-, 3-, and 4-way airflow patterns are available,enabling installation in the corner of a room.750 mmL-shaped 2-way flowAll-round flow is available, as well as 2-way to4-way flows, so you can choose the mostsuitable airflow pattern depending on location orroom layout.Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.170 4-way flow3-way flowL-shaped2-way flow*For 3-way or 2-way flow installation, the sealing material for air discharge outlet(option) must be used to close each unused outlet.18

Indoor Unit LineupVRV Indoor Units4-Way Flow Ceiling Suspended TypeCeiling Mounted Cassette (Double Flow) TypeFXCQ20M / FXCQ25M / FXCQ32MFXUQ71A / FXUQ100AFXCQ40M / FXCQ50M / FXCQ63MFXCQ80M / FXCQ125MThis slim and stylish indoor unit achievesoptimum air distribution, and can be installedwithout the need for ceiling cavity.Unit body and suction paneladopted round shapes andrealised a slim appearancedesign. The unit can be usedfor various locations such asthe ceilings with no cavity andbare ceilings.The thin unit (only 305 mm high) can be installed in aceiling space as narrow as 350 mm. All models feature acompact design with a depth of only 600 mm.305 mmFlaps close automatically whenthe unit stops, which gives asimple appearance.(When a high-efficiency filter is attached, the unit's height is400 mm.)Unified slim height of 198 mmfor all models that gives theunified impression even whenmodels with different capacitiesare installed in the same area.198 mmBuilt-in electronic expansion valve eliminates the needfor a BEV unit, which improves flexibility of installation.Current modelBEV unit isneededNew modelBEV unit isnot neededWith adoption of the individual flap control, airflowdirection adjustment can be individually set for each airoutlet. 5 directions of airflow and auto-swing can beselected with wired remote controller BRC1E62, whichrealises the optimum air distribution.Control of the airflow rate has been improved from2-step to 3-step control. Auto airflow rate control canbe selected with wired remote controller BRC1E62.Energy efficiency has been improved thanks to theadoption of a new heat exchanger with smallertubes, DC fan motor and DC drain pump motor.Drain pump is equipped as a standard accessory, and thelift height has been improved from 500 mm to 600 mm.Depending on installation site requirements or roomconditions, 2-way, 3-way and 4-way dischargepatterns are available.4-way flow3-way flowL-shaped 2-way flowIndividual airflow direction example casePosition 0Position 319Thin, lightweight, and easy to install innarrow ceiling spaces(240 V)(dB(A))FXCQ-M2025/3240/506380125Sound level(H/L)34/2936/3037/3239/3441/3646/40Designed with higher airflow suitable for high ceilingapplication up to 3 metres.Providing 2 different settings of standard and ceiling soilingprevention, the auto swing mechanism realises evendistribution of airflow and room temperature.Drain pump is equipped as standard accessory with600 mm lift.600 mmPosition 2SwingLow operation sound levelAn antibacterial treatment that uses silverions has been applied to the drain pan,preventing the growth of slime, mould andbacteria that cause blockages and odours.(The lifespan of the cartridge dependson the usage environment, but should bechanged once every two to three years.)Two types of optional high-efficiency filter are available(65% and 95%, colourimetric method).A long-life filter (maintenance free up to one year*) isequipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3Major maintenance work can be performed by removingthe panel. A flat-type suction grille and a detachableblade make cleaning easy.20

Indoor Unit LineupVRV Indoor UnitsCeiling Mounted Cassette Corner TypeSlim Ceiling Mounted Duct Type (Standard Series)Slim design, quietness andstatic pressure switchingFXKQ25MA /

First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for over 30 years. Now, Daikin proudly introduces the new VRV IV S series-the ideal air conditioning system for homes, shops and offices. HOMES OFFICES SHOPS Engineered for Flexibility S SERIES 14 Max. indoor units

Related Documents:

Daikin Introduction Course Objectives Daikin introduction and history Daikin as the global leader recognized for energy efficiency, innovation, and high quality products and services Daikin and the environment Target Audience Recommended for anyone Duration 0.5 Hours Class

www.daikinreefer.com Page 1 of 9 23/11/2006 Daikin LXE10E – Technical Information Model shown above is the DAIKIN LXE10E-A15 (Fitted with Transfresh Provision option.)

1. DAIKIN OVERSEAS PARTS SUPPLY CENTER JAPAN PARTS CENTER DAIKIN INDUSTRIES LTD. Sakai Parts Center. 9 Ishizu-Nishi-machi, Sakai, Osaka 592-8332, Japan Phone: 81 (72) 241–9103, Fax: 81 (72) 243–1290 ASIA PARTS CENTER DAIKIN ASIA SERVICING PTE, LTD. 19 Loyang Way #02-21 Singapore 508724 Phone: (65) 546–8678, Fax: (65) 546–9727

Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: February 2018 Page 1 of 7

Daikin University offers classroom training at distributors and dealer facilities and at our Daikin Authorized training facilities in Carrolton, TX, Irvine, CA and Long Island City, NY. Our training facilities have a complete range of fully functional residential and commercial products, including Daikin Altherma and VRV for invaluable hands-on,

Daikin Flex Branch Selector Box Daikin’s new Flex Branch Selector boxes are engineered to be compact and provide flexibility in design, installation, maintenance, and service. Packed with Daikin’s state of the art technology, the new Flex Branch Selector boxes fit in tight mechanical spaces (common in ceilings) combined

is, Daikin has the reliable products, knowledgeable applications expertise and responsive support to fit all your HVAC requirements. Daikin Middle East and Africa is the regional office for all sales and after-market support for the entire product line for Daikin

Daikin is the only global manufacturer in the market capable of offering a true Plug and Play solution where Eurovent-certified Daikin AHUs, offer off-the-shelf compatibility with Daikin’s unique VRV or DX outdoor unit range for the best performance in the market. This unique integration o