Daikin ResidentialFresh Air SolutionRAHU SeriesA preselected installation package for air handlingand outdoor units

Widest range of DX integratedventilation in the marketDaikin offers a variety of solutions from small heat recovery ventilation to large-scale air handling units for the provision offresh air ventilation.Daikin DX air handling units solutions with matching condensing unit and plug and play controlsFive components ofindoor air quality›› Ventilation: Ensures the correct amountof fresh air›› Energy recovery: Delivers energy savings bytransferring heat and moisture between airflows›› Air processing: Delivers the right supplytemperature to decrease the indoor unit load›› Humidification: Ensures relative indoor humiditylevels are respected›› Filtration: Separates pollen, dust and pollutionodours that are harmful to individuals' ficationSimplifying businessThis unique, total solution approach helps businessespropose better cross-pillar solutions and unmatchedproduct combinations that increase their successratio with end-users and simplify the life of installersas all products come from only one manufacturer.NO OEMPRODUCTSDaikin takes pride in not using OEM products in itsAHU with DX offer. Having a single interface for yourbusiness makes Daikin the right choice.One-stop shopDaikin is the only global manufacturer in the marketcapable of offering a true Plug and Play solutionwhere Eurovent-certified Daikin AHUs, offer offthe-shelf compatibility with Daikin’s unique VRV orDX outdoor unit range for the best performancein the market. This unique integration of crosspillar products under the same umbrella gives thecustomer both peace of mind and added value whenpromoting a total solution approach.BUILT-INCONTROLSEC FANSFOR AHUFiltration 2

Standard Features:AHU›› Structure with base frame and aluminium profiles›› Rounded profile as standard, meeting hygiene requirements›› Double chambered profiles type to ensure fixing screws aretotally concealed and there are no projections inside the AHU›› Structure is completed with three-way connecting corners madeof glass-reinforced nylon1940 grade 6.3›› Performance data in accordance with ISO 5801 and AMCA 210,noise measurements as per DIN EN ISO 3745›› Integrated protective devices Alarm signal with floating contacts (250 V AC, 2 A, cos φ 1) Locked rotor protection Phase failure detection Motor soft start Mains low voltage detection Thermal overload protection for electronics and motorPanelsCertified Characteristics - Mechanical›› 42mm thick double skin step panels with polyurethane foaminsulation, insulation density 40-45 Kg/m³›› Step panels ensures a flat surface inside the unit, ensuringcontinuity between the panel and the profile›› External skin 0.7mm thick prepainted galvanized steel /internalskin 0.5mm thick galvanized steel›› Flat roof provided for FAHU to enable outdoor installation›› Casing strength (CS)›› Casing air leakage (CAL)›› Filter bypass leakage (FBL)›› Thermal transmittance of the casing (TT)›› Thermal bridging factor (TBF)›› Acoustical insulation of casingFrameFilters›› Class G4 Prefilters for Recirculating AHU›› Combination Filter Class G4 F7 for FAHUCoils›› R-410a DX Coils›› Coils made of 3/8” / ½ “ diameter copper tubes mechanicallyexpanded in to aluminium fins›› All coils pressure tested at 450 PsiHeat Wheel (FAHU)›› Rotor matrix made of aluminum substrate with desiccant coating›› High latent recovery›› In-built purge sector to eliminate cross contamination›› The rotor wheel outer edge, intermediate beams and purgesector equipped with adjustable brush seals›› The rotor wheel driven by a belt around the periphery which isconnected to a pulley and motorHeat Pipe (FAHU)›› Heat pipes provided to precool the air and reheat the supply air ina wrap-around configuration›› The tubes made of 1/2” OD copper tubes permanently expandedonto the fin collar to form a firm, rigid, and complete pressurecontact at all operating conditions›› The fin surface made of continuous plate type aluminum toprovide maximum heat transfer efficiency›› Performance certified by third party in accordance to BS EN305Fan›› Direct-drive single-inlet centrifugal fan with high-performanceairfoil impeller with rotating diffuser›› External rotor motor, and integral variable speed drive and controlelectronics›› External rotor motor surpasses efficiency class IE4›› Motorized impeller dynamically balanced according to DIN ISOCertified Characteristics - Performance›› Air flow - available static pressure - power input›› Octave band in-duct sound power level›› Airborne sound power level›› Heating capacity›› Cooling capacity›› Heat recoveryDX Condensing Units›› High-efficiency scroll compressor with pressure and temperatureprotection and quiet shut down solution›› Factory-installed filter drier›› Copper tube/aluminum fin coil with herasite fin coating›› Service valves with sweat connections and easy-access gaugeports›› Contactor with lug connection›› Ground lug connection›› Quiet operating top discharge›› Heavy-gauge galvanized-steel cabinet with attractivearchitectural gray powder-paint finish with steel louver coil guard›› Top and side maintenance accessVRV Condensing Units›› Incorporates VRV IV standards and technologies, VRV configurator,7 segment display and full inverter compressors, 4-side heatexchanger, refrigerant cooled PCB, new DC fan motor, 7thgeneration of inverter compressor with back pressure control›› VRV Configurator Software for the fastest and most accuratecommissioning, configuration and customization›› Outdoor Unit display for quick on-site settings and easy read outof errors together with the indication of service parameters forchecking basic functions›› Suitable for outdoor and indoor installation, made possible as aresult of high external static pressure of up to 78.4 Pa›› Special anti-corrosion treatment of the heat exchanger provides5 to 6 times greater resistance against acid rain and salt corrosion.The provision of rust proof steel sheet on the underside of theunit gives additional protection 3

TECHNICAL SPECIFICATION RECIRCULATING AHU / VRV CONDENSING UNITTechnical Specification Recirculating AHU / VRV Condensing UnitCOMBINATION 70x1180Air 0250250250Motor PowerKW1.01.231.231.231.82.951180DimensionAHUModel 4G4G4G4G4G4PrefilterTotal Cooling Capacity (1)KW11.313.115.117.31920.8Sensible Cooling CapacityKW8.910.311.813.314.816.3Fan TypeEC FANEC FANEC FANEC FANEC FANEC FANTypeVRV IV CO SeriesVRV IV CO SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV 0AR410AR410AR410APower .80Rated Power Input (2)KW5.105.106.756.756.756.75Minimum Circuit Amps (MCA) (3)A16.116.116.116.116.116.1Maximum Fuse Amps (MFA) (4)A20.020.020.020.020.020.0Sound Pressure LeveldBA565657575757QtyHermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1TypePropeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller alVerticalCondensing Unit380-415V/50HzCooling Capacity (1)TypeCompressorFanDimensionCondenserCoilFan Discharge DirectionTypeCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilFin TreatmentBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin 165198198198198Liquid ODmm9.529.529.529.529.529.52Gas ODmm19.119.119.119.119.119.1WeightField RefrigerantPipe SizeNotes1.2.3.4.5.6.7.Cooling Capacity at AHU On Coil 24/17 C (DB/WB), Off Coil 14 C (DB) and 46 C ambient, equivalent piping length: 7.5 m (horizontal)Condensing unit Rated Power Input is based on outdoor temp. 46 CDB (as per ISO 15042)MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running currentMFA is used to select the circuit breaker and the ground fault circuit interruptor (earth leakage circuit breaker)Accesories including Expansion Valve and Control box are Factory fitted and Thermostat or Remote control loose suppliedMaximum Piping Horizontal - 50 meters (55 meters equivalent)Maximum Piping Vertical - 40 meters 4

30x1170930 X .725.126.628.129.6EC FANEC FANEC FANEC FANEC FANEC FANEC FANEC FANEC FANVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV 16464HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)1HermeticallySealed ScrollCompressor(Inverter)2HermeticallySealed ScrollCompressor(Inverter)2HermeticallySealed ScrollCompressor(Inverter)2HermeticallySealed ScrollCompressor(Inverter)2Propeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller alVerticalVerticalVerticalVerticalCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin 8.628.628.628.628.628.6 5

TECHNICAL SPECIFICATION RECIRCULATING AHU / DX CONDENSING UNITTechnical Specification Recirculating AHU / DX Condensing UnitCOMBINATION MODELModel tor 0202020202019801980G4G4G4G4G4G4PrefilterTotal Cooling Capacity (1)KW11.212.614.616.818.720.5Sensible Cooling CapacityKW8.910.311.813.314.816.3EC FANEC FANEC FANEC FANEC FANEC FANFan TypeDX Condensing DX Condensing DX Condensing DX Condensing DX Condensing DX CondensingUnitUnitUnitUnitUnitUnitGoodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman R410AR410AR410AR410AR410AR410A380-415V/50HzPower SupplyCondensing UnitRAHU-DR1750ESPDimensionAHUAir 50Hz220-240V/50Hz220-240V/50HzCooling Capacity (1)KW11.2012.6014.6016.8018.7020.50Rated Power Input (2)KW5.095.095.90(3.84) x 2(3.84) x 2(5.09) x 2Minimum Circuit Amps (MCA) (3)A9.39.311.8(20.9) x 2(20.9) x 2(9.3) x 2Maximum Fuse Amps (MFA) (4)A15.015.020.0(35.0) x 2(35.0) x 2(15.0) x 2Sound Pressure LeveldBATypeCompressorQtyTypeFanQtyDimension(per Unit)75777778HermeticallySealed ScrollCompressor1Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller Fan111(1) x 2(1) x 2(1) x 2VerticalVerticalVerticalVerticalVerticalTypeCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilFin TreatmentHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite (70.8) x 2(70.8) x 2(127.9) x 2Liquid ODmm9.529.529.52(9.52) x 2(9.52) x 2(9.52) x 2Gas ODmm22.222.222.2(19.1) x 2(19.1) x 2(22.2) x 2WeightField RefrigerantPipe Size (5)75HermeticallySealed ScrollCompressor1Propeller FanVerticalFan Discharge DirectionCondenser Coil75HermeticallySealed ScrollCompressor1Propeller FanNotes1.2.3.4.5.6.Cooling Capacity at AHU On Coil 24/17 C (DB/WB), Off Coil 14 C (DB) and 46 C ambient, equivalent piping length: 7.5 m (horizontal)Condensing unit Rated Power Input is based on outdoor temp. 46 CDBMCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running currentMFA is used to select the circuit breaker and the ground fault circuit interruptor (earth leakage circuit breaker)Recommended Field Refrigerant Pipe Sizes are based on 7.5 m equivalent length. For long pipe applications, please refer to Table 1, page 12.Accesories including Expansion Valve and Control box are Factory fitted and Thermostat or Remote control loose supplied 6

30x1170930 X 223.725.126.628.129.6EC FANEC FANEC FANEC FANEC FANEC FANEC FANEC FANEC FANDX Condensing DX Condensing DX Condensing DX Condensing DX Condensing DX Condensing DX Condensing DX Condensing DX man (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman (Daikin Goodman 029.9031.6033.3035.9037.30(5.09) x 2(5.09) x 2(5.9) x 2(5.9) x 2(5.9) x 2(5.09) x 3(5.09) x 3(5.09) x 3(5.09) x 3(9.3) x 2(9.3) x 2(11.8) x 2(11.8) x 2(11.8) x 2(9.3) x 3(9.3) x 3(9.3) x 3(9.3) x 3(15.0) x 2(15.0) x 2(20.0) x 2(20.0) x 2(20.0) x 2(15.0) x 3(15.0) x 3(15.0) x 3(15.0) x 3787880808079797979HermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 2Propeller FanHermeticallySealed ScrollCompressor(1) x 3Propeller FanHermeticallySealed ScrollCompressor(1) x 3Propeller FanHermeticallySealed ScrollCompressor(1) x 3Propeller FanHermeticallySealed ScrollCompressor(1) x 3Propeller Fan(1) x 2(1) x 2(1) x 2(1) x 2(1) x 2(1) x 3(1) x 3(1) x 3(1) x erticalVerticalVerticalCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite 02902902902902902902902902902902902902(127.9) x 2(127.9) x 2(130.6) x 2(130.6) x 2(130.6) x 2(127.9) x 3(127.9) x 3(127.9) x 3(127.9) x 3(9.52) x 2(9.52) x 2(9.52) x 2(9.52) x 2(9.52) x 2(9.52) x 3(9.52) x 3(9.52) x 3(9.52) x 3(22.2) x 2(22.2) x 2(22.2) x 2(22.2) x 2(22.2) x 2(22.2) x 3(22.2) x 3(22.2) x 3(22.2) x 3 7

TECHNICAL SPECIFICATION FRESH AIR HANDLING UNIT / VRV CONDENSING UNITTechnical Specification Fresh Air Handling Unit / VRV Condensing UnitCOMBINATION MODELModel NameCFMRAHU-VF1250RAHU-VF1500620 X 850620 X 950680 X 950690 X 80Return Air FlowCFM67590011251350Return Fan ESPPa250250250250Return Fan Motor PowerKW0.790.790.791.00DimensionPaSupply Fan Motor engthmmPrefilter & Bag FilterRotor Type3670367039103910G4 F7G4 F7G4 F7G4 r DiammMotor Total Cooling Capacity (1)KW14.418.826.029.0Sensible Cooling CapacityKW4.76.28.69.6Fan TypeEC FANEC FANEC FANEC FANTypeVRV IV CO SeriesVRV IV SeriesVRV IV SeriesVRV IV 6ARYFKRXYTQ8U7YFRXYTQ10U7YFRXYTQ10U7YFQty1111Heat Pipe RowsCondensing UnitRAHU-VF1000Supply Fan ESPHeat WheelFAHUSupply Air FlowRAHU-VF750RefrigerantR410AR410AR410AR410APower 15V/50HzCooling Capacity (1)KW14.4023.5026.0029.00Rated Power Input (4)KW5.106.758.518.51Minimum Circuit Amps (MCA) (5)A16.116.122.022.0Maximum Fuse Amps (MFA) (6)A20.020.025.025.0Sound Pressure LeveldBA56575959QtyHermetically SealedScroll Compressor(Inverter)1Hermetically SealedScroll Compressor(Inverter)1Hermetically SealedScroll Compressor(Inverter)1Hermetically SealedScroll Compressor(Inverter)1TypePropeller FanPropeller FanPropeller FanPropeller FanQty1122TypeCompressorFanCondenserCoilFan Discharge DirectionTypeDimensionFin TreatmentVerticalVerticalVerticalCross Fin CoilCross Fin CoilCross Fin CoilBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin 2401,240Depthmm765765765765kg165198234234Liquid ODmm9.529.529.529.52Gas ODmm19.119.122.222.2WeightField Refrigerant PipeSizeVerticalCross Fin CoilNotes1.2.3.4.5.6.7.8.9.Declared Cooling Capacity considering Recovery from Heat Wheel and Precool effect of Heat Pipe,equivalent piping length: 7.5 m (horizontal)Fresh Air Temperature On Heat Wheel : 34 C / 32 C (DB/WB) , Return Air Temperature On Heat Wheel: 25 C / 17.9 C (DB/WB)Air off Heat Pipe Reheat : 19-20 C / 15-15.3 C (DB/WB)Condensing unit Rated Power Input is based on outdoor temp. 46 CDB (as per ISO 15042)MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running currentMFA is used to select the circuit breaker and the ground fault circuit interruptor (earth leakage circuit breaker)Accesories including Expansion Valve and Control box are Factory fitted and Thermostat or Remote control loose suppliedMaximum Piping Horizontal - 50 meters (55 meters equivalent)Maximum Piping Vertical - 40 meters 8

F2750RAHU-VF3000740 X 1040750 X 1150690 X 1360690 X 1430750 X 1450820 X 70412038803880G4 F7G4 F7G4 F7G4 F7G4 F7G4 3.814.415.316.0EC FANEC FANEC FANEC FANEC FANEC FANVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV SeriesVRV IV lly SealedScroll Compressor(Inverter)1Hermetically SealedScroll Compressor(Inverter)2Hermetically SealedScroll Compressor(Inverter)2Hermetically SealedScroll Compressor(Inverter)2Hermetically SealedScroll Compressor(Inverter)2Hermetically SealedScroll Compressor(Inverter)2Propeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller erticalCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin CoatingBlue Fin 6 9

TECHNICAL SPECIFICATION FRESH AIR HANDLING UNIT / DX CONDENSING UNITTechnical Specification Fresh Air Handling Unit / DX Condensing UnitCOMBINATION 0x1100CFM7501,0001,2501,500Supply Fan ESPPa250250250250Supply Fan Motor PowerKW1.181.181.81.8Return Air DimensionReturn Fan ESPReturn Fan Motor engthmm3900390040104010G4 F7G4 F7G4 F7G4 ilter & Bag FilterRotor TypeRotor DiammMotor Total Cooling Capacity (1)KW13.918.125.428.3Sensible Cooling CapacityKW5.06.58.810.0EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman 380-415V/50HzHeat Pipe RowsFan TypeTypeManufacturerPower ng Capacity (1)KW13.9018.1025.4028.30Rated Power Input (4)KW5.095.90(5.09) x 2(5.09) x 2Minimum Circuit Amps (MCA) (5)A9.311.8(9.3) x 2(9.3) x 2Maximum Fuse Amps (MFA) (6)A15.020.0(15.0) x 2(15.0) x 2Sound Pressure LeveldBA75777878QtyHermetically SealedScroll Compressor1Hermetically SealedScroll Compressor1Hermetically SealedScroll Compressor(1) x 2Hermetically SealedScroll Compressor(1) x 2TypePropeller FanPropeller FanPropeller FanPropeller FanQty11(1) x 2(1) x CondenserCoilFan Discharge DirectionDimensionCondensing UnitRAHU-DF1000Supply Air FlowHeat WheelAHUModel NameRAHU-DF750TypeCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilFin TreatmentHeresite CoatingHeresite CoatingHeresite CoatingHeresite hmm902902902902kg127.9130.6(127.9) x 2(127.9) x 2Liquid ODmm9.529.52(9.52) x 2(9.52) x 2Gas ODmm22.222.2(22.2) x 2(22.2) x 2WeightField Refrigerant Pipe Size (5)Notes1.2.3.4.5.6.7.8.Declared Cooling Capacity considering Recovery from Heat Wheel and Precool effect of Heat Pipe,equivalent piping length: 7.5 m (horizontal)Fresh Air Temperature On Heat Wheel : 34 C / 32 C (DB/WB) , Return Air Temperature On Heat Wheel: 25 C / 17.9 C (DB/WB)Air off Heat Pipe Reheat : 19-20 C / 15-15.3 C (DB/WB)Condensing unit Rated Power Input is based on outdoor temp. 46 CDBMCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running currentMFA is used to select the circuit breaker and the ground fault circuit interruptor (earth leakage circuit breaker)Recommended Field Refrigerant Pipe Sizes are based on 7.5 m equivalent length. For long pipe applications, please refer to Table 1, page 12.Accesories including Expansion Valve and Control box are Factory fitted and Thermostat or Remote control loose supplied 10

040504050401040103980G4 F7G4 F7G4 F7G4 F7G4 F7G4 4.215.016.216.4EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman (DaikinGroup)EC FANDX Condensing UnitGoodman .5039.6041.3044.4044.70(5.9) x 2(5.09) x 3(5.09) x 3(5.09) x 3(5.09) x 3(5.09) x 3(11.8) x 2(9.3) x 3(9.3) x 3(9.3) x 3(9.3) x 3(9.3) x 3(20.0) x 2(15.0) x 3(15.0) x 3(15.0) x 3(15.0) x 3(15.0) x 3807979797979Hermetically SealedScroll Compressor(1) x 2Hermetically SealedScroll Compressor(1) x 3Hermetically SealedScroll Compressor(1) x 3Hermetically SealedScroll Compressor(1) x 3Hermetically SealedScroll Compressor(1) x 3Hermetically SealedScroll Compressor(1) x 3Propeller FanPropeller FanPropeller FanPropeller FanPropeller FanPropeller Fan(1) x 2(1) x 3(1) x 3(1) x 3(1) x 3(1) x ross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilCross Fin CoilHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite CoatingHeresite 02902902902(130.6) x 2(127.9) x 3(127.9) x 3(127.9) x 3(127.9) x 3(127.9) x 3(9.52) x 2(9.52) x 3(9.52) x 3(9.52) x 3(9.52) x 3(9.52) x 3(22.2) x 2(22.2) x 3(22.2) x 3(22.2) x 3(22.2) x 3(22.2) x 3 11

Technical RecommendationsTable 1: Recommended Field Refrigerant Pipe Sizes for DX Condensing UnitsREFRIGERANT LINE LENGTH (METERS)0-7.57. 6-15.1Model15.2-22.6Line Diameter OD (mm)SuctLiqSuctLiqSuctLiqGSX130362XK19.19.5222.29 .5222.212 .7GSX130485XK22.29.5228.69 .5228.612 .7GSX130605XK22.29.5228.69 .5228.612 .7Table 2: Refrigerant Connection Size for DX Condensing UnitsModelGSX130362XKGSX130485XKGSX130605XKLiquid Valve Size OD, mm9.529.529.52Suction Valve Size OD, mm19.122.222.2Table 3: Minimal Pipe Thickness for R410A Refrigerant 12

INSTALLATION RECOMMENDATIONS FOR AHUThe area chosen for installation must allow for enough space around the unit for comfortably and safely carrying out installation andsuccessive maintenance operations, including the replacement of any internal component (e.g. removal of the heat exchange coils, thefilters, ) see figure.INSTALLATION RECOMMENDATIONS FOR VRV CONDENSING UNITSMake sure the space around the unit is adequate for servicing and the minimum space for air inlet and air outlet is available (refer to thefigure below and choose one of the possibilities). 13

›› In case of an installation site where sides A B C D have obstacles,the wall heights of sides A C have no impact on service spacedimensions. Refer to the figure above for impact of wall heights ofsides B D on service space dimensions.›› In case of installation site where only the sides A B have obstacles,the wall heights have no influence on any indicated service spacedimensionsINSTALLATION RECOMMENDATIONS FOR DX CONDENSING UNITSSpecial consideration must be given to location of the condensing unit(s) in regard to structures, obstructions,other units, and any/all other factors that may interfere with air circulation. Where possible, the top of the unitshould be completely unobstructed; however, if vertical conditions require placement beneath an obstructionthere should be a minimum of 1.5 meters between the top of the unit and the obstruction(s). The specifieddimensions meet requirements for air circulation only. Consult all appropriate regulatory codes prior todetermining final clearances.Another important consideration in selecting a location for the unit(s) is the angle to obstructions. Eitherside adjacent the valves be placed toward the structure provided the side away from the structure maintainsminimum service clearance. Corner installations are strongly discouraged.NOTRECOMMENDEDBBBOK!OK!BMinimum Airflow Clearance, CMinimum Airflow ClearanceModelTypeABCAA 14Residential10"10"18"20"

ControlsThe main components of a Daikin AHU are:›› Supply and return fast: Supply and return fans are used to regulate the air volume.›› Air filters: pre-filter and bag filter: Every AHU unit can be equipped with severaltypes of filters used to clean the air from little particles of dust etc.›› Device for heat recovery: These devices are used to recover cooling or heatingfrom the return air.›› DX coils: These are the devices used for air temperature conditioning.›› Electrical and Control Section: The AHU is equipped with electrical and controlssection for the power input to the supply fan, return fan and the controllersincluding the switchgear, control components, relays, etc.›› Field Sensors: To control the air handling units the required temperature andpressure sensors will be provided.Controller:Daikin offers maximum flexibility in the control and monitoring of

Daikin is the only global manufacturer in the market capable of offering a true Plug and Play solution where Eurovent-certified Daikin AHUs, offer off-the-shelf compatibility with Daikin’s unique VRV or DX outdoor unit range for the best performance in the market. This unique integration o

Related Documents:

Daikin Introduction Course Objectives Daikin introduction and history Daikin as the global leader recognized for energy efficiency, innovation, and high quality products and services Daikin and the environment Target Audience Recommended for anyone Duration 0.5 Hours Class

VRV Air Conditioning System is the world's first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982. VRV is the trade mark of Daikin Industries, Ltd., which is derived from the technology we call "variable refrigerant volume." VRV is a trade mark of Daikin Industries, Ltd. S

Unit ventilators . 750 to 2,000 cfm Fan coil units. 200 to 3,000 cfm. 1 Choose a Daikin Trailblazer air cooled scroll chiller 2 Add a Daikin air handler or terminal unit. The industry leader in environmental solutions Daikin Applied is comm

Unit ventilators . 750 to 2,000 cfm. Fan coil units. 200 to 3,000 cfm. 1. Choose a Daikin Trailblazer air cooled scroll chiller. 2. Add a Daikin air handler or terminal unit. The industry leader in environmental solutions . Daikin Applied is committed to

VRV Air Conditioning System is the world's first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982. VRV is the trade mark of Daikin Industries, Ltd., which is derived from the technology we call "variable refrigerant volume." VRV is a trade mark of Daikin Industries, Ltd. Dealer

Daikin University offers classroom training at distributors and dealer facilities and at our Daikin Authorized training facilities in Carrolton, TX, Irvine, CA and Long Island City, NY. Our training facilities have a complete range of fully functional residential and commercial products, including Daikin Altherma and VRV for invaluable hands-on,

Unit ventilators 750 to 2,000 cfm Fan coil units 200 to 3,000 cfm 1 Choose a Daikin Magnitude chiller 2 Choose a Daikin air handler or terminal unit Daikin Middle East and Africa The present publication is drawn up by way of information only and does not constitute an offer binding upon

Pearson BTEC Level 3 National Diploma in Business (720 GLH) 601/7157/1 . Pearson BTEC Level 3 National Extended Diploma in Business (1080 GLH) 601/7160/1 . This specification signposts all the other essential documents and support that you need as a centre in order to deliver, assess and administer the qualification, including the staff development required. A summary of all essential .