Rosemount 2160 Field Communication Unit

2y ago
20 Views
4 Downloads
435.37 KB
6 Pages
Last View : 15d ago
Last Download : 3m ago
Upload by : Camryn Boren
Transcription

Product Data SheetDecember 201300813-0100-5160, Rev AARosemount 2160 Field Communication Unit Collects, stores and sends tank gauging data Includes redundant option for higher safety Transmits data using TRL2 bus, RS232 or RS485 Provides six communication ports that can beindividually configured as group bus ports orfieldbus portsSupports connection also to previousgeneration tank gauges Enables write protection

Rosemount 2160December 2013Field Communication UnitThe Rosemount 2160 Field Communication Unit is a dataconcentrator that continuously polls data from Rosemount tankgauging field devices via the 2410 Tank Hub. The 2160 alsosupports connection of older Rosemount tank gauginginstruments such as TankRadar Pro and TankRadar Rex gauges.Redundant field communication unitsThe 2160 stores data in a buffer memory. Whenever a request isreceived from a host, the field communication unit canimmediately send data from the updated buffer memory.Two field communication units can be connected in parallel.One of the units will be configured as the primary, and it will bein an active state. The other will be in a backup state.AlternativeNumber offieldbus portsNumber ofgroup bus ports1 (standard)42233324An interface board can be connected for each communicationport. These boards can be ordered either for TRL2 bus or RS485communication. Two group bus ports can also be configured asRS232.RxTxUSBOn - TERM - OffRS-232RxTxLo - GAIN - HiFBM 2180Ext. pwrRosemount TankRadarRosemount TankRadarUSBOn - TERM - OffFBM 2180RS-232Lo - GAIN - HiExt. pwrRxTxUSBOn - TERM - OffRS-232Lo - GAIN - HiExt. pwrRxTxUSBRS-232FBM 21802180 Field Bus ModemsRosemount TankRadarRosemount TankRadarExt. pwrRosemount 2160 acts as a slave on the group bus and as amaster on the fieldbus. The unit has six communication ports.These ports can be individually configured as either group busports or as fieldbus ports according to one of the alternativesbelow:By designing a tank gauging system with two identical(redundant) devices for critical operations, it is possible to gethigher built-in reliability.Lo - GAIN - HiOn - TERM - OffFBM 21802160 Field CommunicationsUnits2410 Tank HubsEach radar level gauge / Rosemount 2410 Tank Hub has anindividual address on the fieldbus.The units are software monitored and the backup unit isautomatically triggered and activated in case of a primary unitfailure. A message is sent to TankMaster (or a DCS system) thatthe primary unit has failed and that the backup unit has takenover the communication.Groupbuses2160 FieldCommunicationUnitRosemount 2160Field Communication UnitIn addition, buddy mode functionality enables use of redundantfieldbus ports.FieldbusesContentsOrdering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52www.rosemount-tg.com

December 2013Rosemount 2160Ordering informationRosemount 2160 Field Communication UnitAdditional informationSpecifications: page 5Dimensional drawings: page 5Table 1. Rosemount 2160 Field Communication Unit ordering informationModelProduct Description - Pos 160Field Communication UnitPower Supply - Pos 21115 VAC2230 VACPort 1 - Pos 3G1Group bus, TRL2 busG3Group bus, RS485 busG5Group bus, RS232 busPort 2 - Pos 4G1Group bus, TRL2 busG3Group bus, RS485 busG5Group bus, RS232 busPort 3 - Pos 5F1Fieldbus, TRL2 busPort 4 - Pos 6F1Fieldbus, TRL2 busPort 5 - Pos 7F1Fieldbus, TRL2 busG1Group bus, TRL2 busG3Group bus, RS485 buswww.rosemount-tg.com3

Rosemount 2160December 2013Table 1. Rosemount 2160 Field Communication Unit ordering informationPort 6 - Pos 8F1Fieldbus, TRL2 busG1Group bus, TRL2 busG3Group bus, RS485 busCommunication Protocol - Pos 9STankMasterMModbus RTU to other host (required for communication with host)Extended Function - Pos 100NoneRRedundancy function (requires a second FCU with redundancy)BBuddy mode (maximum 16 devices)Special - Pos 110NoneAccessory - Pos 120NoneWSun shelter kitSign - Pos 13SStandard signXOther specified in orderTypical Model Number: 216042G1G5F1F1F1F1SR0WSwww.rosemount-tg.com

December 2013Rosemount 2160SpecificationsTable 2. Rosemount 2160 Field Communication Unit specificationsGeneralProductRosemount 2160 Field Communication UnitHazardous location certificationsNoneCE-markComplies with applicable EU directives (EMC, ATEX and LVD)Configuration / CommunicationNumber of tanks per fieldcommunication unitCommunicationMax 32Fieldbus ports: TRL2 bus, and RS485Recommended number of tank hubs per fieldbus port: Maximum 8 if TRL2, and 32 if RS485Group bus ports: TRL2 bus, RS232 or RS485Group bus baud rate: Programmable up to 19 200 BaudHost communication protocol: Modbus RTUElectricPower supply115 or 230 VAC, 10% to -15%, 50-60 Hz, max. 10 WMechanicalCable entry (connection/glands)Seven M20 x 1.5 entries for cable glands and conduits (plastic glands included in the delivery)Weight4.5 kg (9.9 lbs)InstallationWall-mounted with four screwsEnvironmentAmbient operating temperature-40 to 70 C (-40 to 158 F)Ingress protectionIP 65Write protect switchYesDimensional drawingsFigure 1. Rosemount 2160 Field Communication Unit dimensionsDimensions are in mm (inches)230 (9)280 (11)Rosemount 2160Field Communication UnitCable inletswww.rosemount-tg.com5

Rosemount 2160Product Data Sheet00813-0100-5160, Rev AADecember 2013Emerson Process ManagementRosemount Tank GaugingEmerson Process ManagementRosemount Tank Gauging North America Inc.Box 130 45SE-402 51 GöteborgSWEDENTel: 46 31 337 00 00Fax: 46 31 25 30 22E-mail: sales.rtg@emerson.comwww.rosemount-tg.com6005 Rogerdale RoadMail Stop NC 13677072 TX HoustonUnited StatesPrimary Phone: 1 281 988 4000Secondary Phone: 1 800 722 2865E-mail: sales.rtg.hou@emerson.comEmerson Process ManagementAsia Pacific Pte LtdEmerson Process ManagementRosemount Tank Gauging Middle East & Africa.1 Pandan CrescentSINGAPORE 128461Tel: 65 6777 8211Fax: 65 6777 0947Email: specialist-itg.rmt-ap@ap.emersonprocess.comP. O Box 20048ManamaBahrainTel: 973 1722 6610Fax: 973 1722 7771E-mail: rtgmea.sales@emerson.comThe Emerson logo is a trade mark and service mark of Emerson Electric Co.Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.HART and WirelessHART are registered trademarks of the HART Communication FoundationAll other marks are the property of their respective owners. 2013 Rosemount Tank Radar AB. All rights reserved.

Rosemount 2160 December 2013 www.rosemount-tg.com Field Communication Unit The Rosemount 2160 Field Communication Unit is a data concentrator that continuously polls data from Rosemount tank gauging field devices via

Related Documents:

Rosemount 3051S 305 A11 N/A 306 A11 N/A 304 A12 N/A Rosemount 3051/2051 305 N/A S5 306 N/A S5 304 N/A S6 Rosemount 2088 305 N/A N/A 306 N/A S5 304 N/A N/A Rosemount 4088 305 A11 N/A 306 A11 N/A 304 A12 N/A. Procedure. 1. Specify a completed Rosemount transmitter model number by referencing the applica

Rosemount 3051S 305 A11 N/A 306 A11 N/A 304 A12 N/A Rosemount 3051/2051 305 N/A S5 306 N/A S5 304 N/A S6 Rosemount 2088 305 N/A N/A 306 N/A S5 304 N/A N/A Rosemount 4088 305 A11 N/A 306 A11 N/A 304 A12 N/A. Procedure. 1. Specify a completed Rosemount transmitter model number by referencing the applica

A11(12)(13) Assemble to Rosemount 305 Integral Manifold A12(12) Assemble to Rosemount 304 or AMF manifold with 316 SST traditional flange C11(12) Assemble to Rosemount 405C or 405P Primary Element D11(12) Assemble to Rosemount 1195 Integral Orifice and 305 Manifold EA2(12) Assemble to Rosemount 485 or 405A Annubar

A11(5) Assemble to Rosemount 305 Manifold Assemble to Rosemount 306 Manifold A12(5) Assemble to Rosemount 304 or AMF Manifold with SST Traditional Flange N/A B11(5)(6) Assemble to One Rosemount 1199 Remote Diaphragm Seal with SST transmitter flange Assemble to One Rosemount 1199 Remote Diaphragm

Rosemount 644 Smart Temperature Transmitters may be protected by one or more U.S. Patents pending. Other foreign patents pending. Rosemount 644 Hardware Revision . Rosemount 644 Head Transmitter. Rosemount 644. Rosemount 644. Reference Manual 00809-0100-4728, Rev JA. January 2004

Rosemount 3051 www.rosemount.com 00825-0100-4797G Quick Installation Guide 00825-0100-4797, Rev EA June 2010 Rosemount 3051 Pressure Transmitter with Profibus-PA Rosemount 3051CF Series Flowmeter Transmitter with Profibus-PA Start End Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers

Rosemount 3051S/3051/2051/3095 Rosemount 1151 D C D Rosemount 3051S/3051/2051/3095 Rosemount 1151 Februari 2019. 8 Snelstartgids 2.6 Montagerichting inline-druktransmitter De drukpoort aan de lage kant (ref. atmosferische druk) op de inline-verschildruktransmitter bevindt zich in de hals van de transmitter, achter

4 Shaft Capacity in Clay (Alpha Method) Soft-stiff clay Adhesion factors