Switching Power SupplyS8PSCompact DIN-Rail MountingIndustrial Power Supplies withCapacities Up to 600 W Models range from 50 W to 600 W Universal input: voltage range100 to 240 VAC Power Factor Correction (PFC) on allmodels UL508 approval on 100-W and150-W models DIN-rail mounting brackets provided(except with 600-W model) Protection-ON alarm indicators(300-W and 600-W models) UL, CSA, VDE, and CE approved 3-year warrantyOrdering Information OPEN-FRAME TYPE POWER SUPPLIES WITH FRONT-MOUNTING BRACKETSRated input voltageg100 to 240 VACPower ratingsgOutputPart numberVoltageCurrentFront-mountingbracketDIN-rail mountingbracket5V10 AS8PS-05005S8PS-05005D12 V4.2 AS8PS-05012S8PS-05012D24 V2.1 AS8PS-05024S8PS-05024D100 W24 V4.5 AS8PS-10024S8PS-10024D150 W24 V6.5 AS8PS-15024S8PS-15024D50 W COVERED TYPERated input voltageg100 to 240 VACPower ratingsgOutputPart numberVoltageCurrentFront-mountingbracketDIN-rail mountingbracket5V10 AS8PS-05005CS8PS-05005CD12 V4.2 AS8PS-05012CS8PS-05012CD24 V2.1 AS8PS-05024CS8PS-05024CD100 W24 V4.5 AS8PS-10024CS8PS-10024CD150 W24 V6.5 AS8PS-15024CS8PS-15024CD50 W

S8PSS8PS ENCLOSED TYPERated input voltageg100 to 240 VACPower ratingsgPart numberOutputVoltageCurrentFront-mounting bracketDIN-rail mounting bracket300 W24 V14 AS8PS-30024CS8PS-30024CD600 W24 V27 AS8PS-60024C--- MODEL NUMBER LEGENDS8PS1231. Power Ratings050: 50 W100: 100 W150: 150 W300: 300 W600: 600 W2. Output Voltage3. Configuration05: 5 V12: 12 V24: 24 VC: Covered type with Front-mounting BracketD: Open-frame type with DIN Rail Mounting BracketCD: Covered type with DIN Rail Mounting BracketNone: Open-frame type with Front-mounting Bracket ACCESSORIES (SOLD SEPARATELY)DescriptionLengthWidthPart numberDIN-rail ((See Dimensions section for details.))0.5 m (1.64 ft)7.3 mm (0.29 in)PFP-50N1 m (3.28 ft)7.3 mm (0.29 in)PFP-100N1 m (3.28 ft)16 mm (0.63 in)PFP-100N2SpecificationsItem50 WEfficiency (typical)74 to 80% (depends on the model)100 W150 W300 W600 WLife expectancy (See Note 3.)10 yrs. min. (used at 40 C at the rated input with a 50% load, standard installation)InputVoltage100 to 240 VAC (85 to 264 VAC)Frequency47 to 63 HzCurrent (See Note 1.)0.9 or 0.45 Amax.Power factor (See Note 1.)0.95 TYP.Leakage current(See Note 1.)0.5 or 1.0 mA max.Inrush current (25 C, cold start)(See Note 1.)25 or 50 A max.1.8 or 0.9 A max.2.7 or 1.4 A max.5.4 or 2.7 A max.10 or 5 A max.(This table continues on the next page.)Note: 1. 100% load for rated input voltage (100 VAC or 200 VAC)2. Mean Time Between Failures is calculated according to the probability of accidental device failures, and indicates reliability ofdevices. Therefore, it does not necessarily represent a life of the product.3. The life expectancy shown in the above table indicates average operating hours under the ambient temperature of 40 C and aload rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. It must benoted that the life expectancy of the fan built into the 600-W model is not included.4. The weight indicated is for the open-frame type. (Includes the cover for 300-W and 600-W models.)

S8PSS8PSSpecifications Table -- continued from previous page50 WItem100 W150 W300 W600 WOutputVoltage adjustment range--5% to 10%Ripple (See Note 1.)2% (p--p) max.Input variation influence0.4% max. (at 85 to 132 VAC input/at 170 to 264 VAC input, 100% load)Load variation influence0.8% max. (with rated input, 0 to 100% load)Temperature variation influence (See Note 1.)0.05%/ C max.Rise time1,000 ms max. (up to 90% of output voltage at rated output voltage/current)Hold time (See Note 1.)20 ms min.Additional functionsOverload protection105% min., voltage trailing intermittent operation(With the 600-W model, output is turned OFF at 5 s min.)Overvoltage protectionYesOverheat protectionNoProtection-ON alarm indicatorNoYes (Red)Parallel operationNoYes, 2 units max.YesCharacteristicsCooling methodAmbient temperatureNatural air-coolingFanOperatingSee the derating curve in the Engineering Data section. (with no condensation oricing)Storage--25 C to 65 C (-13 F to 149 F) with no condensation or icingAmbient humidity25% to 85%Dielectric strength3.0 kVAC, 50/60 Hz for 1 min (between all inputs and outputs)2.2 kVAC, 50/60 Hz for 1 min (between all inputs and GR terminals)1 kVAC, 50/60 Hz for 1 min (between all outputs and GR terminals)Insulation resistance100 MΩ max. (between all output and input/GR terminals at 500 VDC)Vibration resistance10 to 55 Hz, 0.75-mm amplitude for 2 h each in X, Y, and Z directionsShock resistance300 m/s2 (approx. 30G), 3 times each in X, Y, and Z directionsOutput indicatorYes (green)Electromagnetic interferenceConforms to FCC Class B, EN50081-1EMC(EMI):Emission Enclosure:Emission AC Mains:Harmonic Current:(EMS):Immunity ESD:Approved standardsUL1012, CSAC22.2 No.950, CSAC22.2 No. 14,EN60950,VDE0160.Mean Time Between Failure (MTBF) See Note 2.135,000 hrs min.Weight (See Note 4.)400 g max.EN50081-1EN55022 class BEN55022 class BEN61000-3-2EN50082-2EN61000-4-2: 4-kV contact discharge (level 2)8-kV air discharge (level 3)Immunity RF-interference:ENV50140:10 V/m (80 MHz to 1 GHz) (level 3)Immunity Conducted Disturbance: ENV50141:10 V (0.15 to 80 MHz) (level 3)Immunity Burst:EN61000-4-4: 2-kV power-line (level 3)2-kV output line (level 4)Immunity Surge:EN61000-4-5: between 3-kV linesbetween 4.5-kV line and FGUL508, UL1012, CSAC22.2 No. 950, CSAC22.2 No. 14, EN60950,VDE0160.700 g max.UL1012, CSA C22.2 No. 950,CSA C22.2 No. 14, EN60950,VDE0160.60,000 hrs min.900 g max.2,200 g max.3,500 g max.Note: 1. 100% load for rated input voltage (100 VAC or 200 VAC)2. Mean Time Between Failures is calculated according to the probability of accidental device failures, and indicates reliability ofdevices. Therefore, it does not necessarily represent a life of the product.3. The life expectancy shown in the above table indicates average operating hours under the ambient temperature of 40 C and aload rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. It must benoted that the life expectancy of the fan built into the 600-W model is not included.4. The weight indicated is for the open-frame type. (Includes the cover for 300-W and 600-W models.)

S8PSS8PSEngineering Data DERATING CURVEOpen-frame TypeCovered Type50- to 150-W ModelsForced air-cooling;600-W ModelLoad (%)Load (%)50- to 150-W ModelsForced air-cooling50- to 150-W ModelsNatural air-cooling50- to 150-W ModelsNatural air-coolingAmbient temperature ( C)Ambient temperature ( C)Note: 1. The derating curve shown is for standard installation. The derating curve depends on mounting direction of the Power Supply.2. Forced air-cooling must be provided with an air volume of 1 m3/mm min. STANDARD INSTALLATION50-W Type20 mm min. 20 mm min.20 mm min.20 mm min.20 mm min.20 mm min.20 mm min.20 mm min.100/150-W Type30 mm min.30 mm min.20 mm min.20 mm min.30 mm min.30 mm min.20 mm min.300-W Type30 mm min.30 mm min.20 mm min.20 mm min.600-W Type20 mm min.20 mm min.20 mm min.20 mm min.20 mm min.

S8PSS8PS OVERLOAD PROTECTIONThe Power Supply has an overload protection function thatprotects the load and the power supply from possibledamage by overcurrent. When the output current rises abovea set value (105% of the rated output current), the protectionfunction is triggered, decreasing the output voltage. Whenthe output current falls within the rated range, the overloadprotection function is automatically cleared.600-W ModelsOutput voltage (V)50- to 300-W ModelsIntermittentoperationIf an excessive current flows for 5 s or more, the output willbe turned OFF and simultaneously protection-ON alarmindicator will be lit. To reset the S8PS, turn OFF the inputvoltage, leave the S8PS for at least three minutes, and thenapply the input voltage again.Note: Do not continue using the S8PS with the output terminals short-circuited or the overcurrent condition continued, otherwise the internal elements of the S8PSmay be damaged or broken.RatingOutput current (%)The Power Supply has an overvoltage protection functionthat protects the load and the Power Supply from possibledamage by overvoltage. When the output voltage risesabove a set value (120% of the rated output voltage), theprotection function is triggered, shutting OFF the outputvoltage. If this occurs, reset the Power Supply by turning itOFF for 1 minute min. and then turning it ON again.300- and 600-W ModelsOutput voltage (V) OVERVOLTAGE PROTECTIONRatedoutputvoltageIf voltage that is 115% of the rated output voltage or above isoutput, the output voltage will be turned OFF andsimultaneously protection-ON alarm indicator will be lit. Toreset the S8PS, turn OFF the input voltage, leave the S8PSfor at least one minute and then apply the input voltageagain.0V OVERHEAT PROTECTION FUNCTION600-W Model OnlyIf the internal temperature of the S8PS rises excessively as aresult of fan failure or any other reason, the overheat protectioncircuit will be triggered to protect the internal elements of theS8PS and simultaneously a protection-ON alarm indicator will belit. To reset the S8PS turn OFF the input voltage, leave the S8PSfor at least one minute and then apply the input voltage again.OvervoltageprotectionoperatingVariable range

S8PSS8PS INRUSH CURRENT, RISE TIME, HOLD TIMEInput ONInput OFFAC inputvoltageInrush current on input applicationAC inputcurrent96.5%90%OutputvoltageRise time(1,000 ms max.)Hold time(20 ms min.)Operation BLOCK DIAGRAMSS8PS-050 (50 W)Rectifier VAC(L)FuseINPUTAC(N)Noise filterDC OUTInrush currentprotection /smoothingcircuitDrive controlcircuitOverloaddetection circuitDetectorOvervoltagedetection circuit

S8PSS8PSS8PS-10024S8PS-15024S8PS-30024 (100 W) (150 W) (300 W)RectifierAC(L)FuseINPUT VNoise filterDC OUTAC(N)Inrush currentprotection /smoothingcircuitControl circuitOverloaddetection circuitDetectorOvervolltagedetection circuitS8PS-60024C (600 W)DC OUTRectifier/smoothingcircuitControl ctionOvervoltagedetection circuit

S8PSS8PSDimensionsUnit: mm (inch) FRONT-MOUNTING BRACKET TYPENote: For instructions on how to install the front-mounting brackets, refer to the a subsequent section: FRONT-MOUNTING BRACKETS.S8PS-050S8PS-050 (50 W) C (50 W)40(1.57)11.5 max.127 (5)3.57885(3.35)7108.6Five, M4terminal screws3.5 dia.3.5 dia.117 (4.6)11753.52828242014Three, M3depth: 6 max.100 (3.94)12.5S8PS-10024 (100 W)S8PS-10024C (100 W)50(1.97)11.5 max.145 (5.71)4.57892(3.62)108.6Five, M4 terminal screws74.5 dia.135 (5.31)Mounting holes (also onopposite side)1354.5 dia.4.5252827.515Three, M4depth: 6 max.100 (3.94)12.5

S8PSS8PSS8PS-15024 (150 W)S8PS-15024C (150 W)50(1.97)163 (6.43)11.5 max.4.5781092(3.62)78.6Five, M4 terminal screws153 (6.02)4.5 dia.153Mounting holes (also onopposite side)54.5 dia.4.5252827.515Three, M4 (depth: 6 max.)100 (3.94)12.5S8PS-30024C (300 W)Eight, M4depth: 8 max.,(also for theopposite side)10175 (6.89)14Seven, M4 terminal screws92(3.62)50(1.97)8.621110 (4.33)13150 (5.91)Four, M4depth: 8 max.100(3.94)13150 (5.91)5

S8PSS8PSUnit: mm (inch)S8PS-60024C (600 W)Seven, M4depth: 8 max.Eight, M4depth: 8 max.,(alsofor the opposite side)170 (6.69)108.6179 (7.05)60(2.36)92(3.62)1631160 (6.30)Four, M4depth: 8 max.,(opposite sideFour, M4only)depth: 8 max.14100(3.94)45(1.77)1234150 (5.91)100 (3.94)

S8PSS8PS FRONT-MOUNTING BRACKETS50-W ModelsUsing the Mounting Bracket1.59114.6Attach the Mounting Bracket to the panel and loosely tighten the two screws. Insertthe projected parts of the Bracket (b) to the square holes of the power supply (a).Then securely tighten the screws.15Two,3.5 dia.60744.6205Mounting Holes1131.54.715Two, M36020.520Mounting Bracket100/150-W ModelsAppearance andMounting DimensionsDimensions with Mounting BracketUsing the Mounting BracketMounting BracketMounting Bracket6.5115 dia.23.51.5115(4.53)max. 10538Mounting Bracket30Two, 5 dia.

S8PSS8PSUnit: mm (inch)300/600-W ModelsAppearance and Mounting Dimensions10 dia.R2.515307.57.5145 (5.71)160 (6.30)Two,5 dia.92 (3.62)48(1.89)32(1.26)Dimensions with Mounting Bracket -- 300-W modelsUsing the Mounting BracketNote: Mounting screws for the Power Supply Unit are provided.300-W models145(5.71)80(3.15)Note: Mount the Unit 21.6 mm away from the mounting surface inorder to provide air ventilation on the rear side.Four, M4Dimensions with Mounting Bracket -- 600-W models600-W models145(5.71)Note: Mount the Unit 28 mm away from the mounting surface inorder to provide air ventilation on the rear side.140 (5.51)Four, M4

S8PSS8PS DIN-RAIL MOUNTING TYPENote: DIN-Rail Mounting Bracket is attached to the Power Supply Unit when the Unit is shipped.S8PS-050S8PS-050 D (50 W) CD (50 W)40(1.57)11.5max.127 (5)9.13.57285(3.35)46108.673.5 dia.5Five, M4terminalscrews117132.6 (5.22)5.6(With slide: 9 max.)S8PS-10024D (100 W)S8PS-10024CD (100 W)50(1.97)9.111.5max.145 (5.71)4.5461092(3.62)8.67Five, M4terminalscrews4.5 dia.5135 (5.31)5.6(With slide: 9 max.)150.6 (5.93)S8PS-15024D (150 W)S8PS-15024CD (150 W)50(1.97)9.111.5max.163 (6.42)4.59278 (3.62)10468.6Five, M4terminalscrews153 (6.02)4.5 dia.168.6 (6.64)5.6(With slide: 9 max.)

S8PSS8PSUnit: mm (inch)S8PS-30024CD (300 W)141017.8175 (6.89)Seven, M4 terminal screws92(3.62)8.646(1.81)189.3 (7.45)110 (4.33)5.6(Withslide:9 max.) DIN-RAIL (ORDER SEPARATELY)PFP-100N2PFP-100N/PFP-50N167.3 0.154.54.535 0.315252510* For PFP-50N251,000500*2510155*27 0.15135 0.315252510251,00025 1510272429.211.5

S8PSS8PSInstallation 50-W MODELS 100-/150-W MODELS4545113322 300-W MODELS 600-W MODELS4515 462136231. DC Output Terminals: Connect the load lines to these terminals.2. Input Terminals: Connect the input lines to these terminals.Note: A fuse is inserted into the AC (L) side.3.4.5.6.Ground Terminal (GR): Connect a ground line to this terminal.Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON.Output Voltage Adjuster (V.ADJ): It is possible to increase or decrease the output voltage by 10%.Protection-ON Alarm Indicator: The red indicator will be lit if the overvoltage (for a 300-/600-W model) or overheat protection (fora 600-W model) circuit is triggered. This indicator will also be lit when overcurrent (for a 600-W model) is detected.

S8PSS8PSPrecautions! WARNINGDo not touch the S8PS or heat radiation fin while thepower is being supplied or immediately after the power isturned OFF. Otherwise, a skin burn may result from thehot Switching Power Supply or radiator. GENERATING OUTPUT VOLTAGE ( )An output of can be generated by using two Power Supplies asshown below, because the Power Supply produces a floatingoutput. VLoadINPUT-- V VINPUTLoadWhen mounting the power supply, allow space for adequateair flow around it -- to improve and maintain the reliability ofthe power supply over a long period of time. The power supply is designed to dissipate heat through natural air-flow.Omron recommends mounting the power supply to a metalplate.Forced air-cooling is recommended.InputOnly 300- and 600-W models can be in parallel operationprovided that they are operated under 90% of the ratings. Do notoperate any other models in parallel.Make sure that the thickness and the length of all wiresconnected to the load are the same to ensure that the wires willhave no voltage drop differences. MOUNTING PARALLEL OPERATION-- V VINPUT-- V FAN REPLACEMENTThe service life of the fan is approximately 50,000 hours (at25 C). The service life varies, however, depending on theambient temperature or other surrounding environmentalconditions such as dust. As a preventive maintenance measure,replace the fan within two years if it is used at an ambienttemperature of 40 C.LoadFans are available as replacements. VINPUTModel: S82Y-JFAN-- V SERIES OPERATIONOnly models with power ratings of 100/150 W allow seriesoperation.As shown in the following diagram, the output voltage from eachSwitching Power Supply can be added. VINPUTLoad--V VINPUT--VFan Set:Fan (above), four M4 x 35 sems screws, instruction sheet, andpacking case.Replace the fan as shown in the following illustration.

S8PSS8PSNOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC.OMRON CANADA, INC.One East Commerce DriveSchaumburg, IL 60173885 Milner AvenueScarborough, Ontario M1B 5V81-800-55-OMRON416-286-6465Cat. No. GC PS57/99Specifications subject to change without notice.Printed in U.S.A.

Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 50 W to 600 W Universal input: voltage range 100 to 240 VAC Power Factor Correction (PFC) on all models UL508 approval on 100-W and 150-W models DIN-rail mounting brackets provided (except with 600-W model) Protection-ON .

Related Documents:

5.5 Switching power supply LED: if you want to use this charger as a switching power supply unit, please press and hold (3-5s) the mode selection button repeatedly until the switching power supply LED turns on. There are three colours in switching power supply mode. Green- 13.2V, red- 13.4V, orange-

POWER SUPPLY TDR-480-48 AC-DC Industrial 3 Phase DIN Rail Power Supply Mean Well LRS 50-24 Single Output Switching Power Supply Mean Well LRS50-12 50W Single Output Switching Power Supply MDR-20-12 AC-DC Industrial DIN Rail Power Supply O u r P r o d u c t R a n g e

QuickSpecs HP ProLiant ML350 Generation9 (Gen9) Overview c04375628 - DA - 15035 North America — Version 3 — October 13, 2014 Page 2 Rear View (Tower Model) 1. Power supply Power LED 2. Power supply Power connection 3. HP Flexible Slot 4 Power Supply (Optional - 500w Power Supply shown) 4. Power supply Power LED 5. Power supply Power .

Design of Efficient Flyback Switching Power Supply Based on LM5021 HOU Xingang1, a,WANG Lei1, b,CHEN Heng1, c,and CHEN Jinglei1, d 1 Xijing U nivers ty ,' aS hx , C 7 10 23 a 707861498@qq.com, b774383203@qq.com, cchenhenrys@qq.com, d 843699667@qq.com Keywords: flyback switching power supply; LM5021; current-limiting circuit; transformer Abstract. The paper introduces the process of .

Switching power supply technology is ubiquitous! Cheap switching power supplies are used in LED fixtures, electric fences, desktop and laptop computers, tablets, wi-fi routers, DC to AC power inverters cell phone battery chargers, doorbell cameras, radios. In general, if it powers a USB device, chances are, it's a switching power supply.

Switching regulators operate by rapidly switching the pass transistor between two efficient operating states: 1. Cutoff- where there is a high voltage across the pass transistor, but no current flow. 2. Saturation- where there is a high current through the pass transistor, but a very small voltage drop. Characteristics of Switching Power .

that we have finite switches in finite time. In this paper we study continuous switching systems. A continuous switching sys-tem is a switching system with the additional constraint that the switched subsystems agree at the switching time. More specifically, consider Equation (1) and suppose

CUERPOS Y ROSTROS Alfredo López Austín lnstituto de Investigaciones Antropológicas - UNAM En una reseña allibro Literatura náhuatl de Arnos Segala,r Miguel León-Portilla se refiere a dos afi¡maciones que aparecen en mi li- bro Cuerpo humano e ideología:z en una ocasión para criticar mi interpretación filológica de la palabra tlacatl y en otra para contes-