Table Of Contents - Conquest Imaging

3y ago
52 Views
3 Downloads
5.95 MB
129 Pages
Last View : 29d ago
Last Download : 3m ago
Upload by : Sutton Moon
Transcription

GE Logiq E9/Vivid E9 Training ManualTable of ContentsTable of Contents . iModule 1 Introduction . 1Other Course Offerings .1Vivid E9 . 2Module 2 System Hardware and Theory . 3Vivid E9 Basic Block Diagram . 4Electronic Sub-systems.4System Front End Components .5E9 Front End Processor (FEP) .5Front End Signal Flow .6Front End Signal Flow MRX Configuration . 7System Backend Components.7Back End Processor (BEP) .7Generic BEP Block Diagram . 8Logiq E9 BEP . 8IO Board .9VIVID E9 Video Audio & USB Connectors . 9Patient I/O Module . 10Touch Screen . 10Control Panel. 11Logiq E9 Control Panel . 11Vivid E9 Control Panel . 12Video Monitor . 12System Audio . 13Power Distribution Components. 13Main Power Supply (MPS). 13Vivid E9 Power Supply . 13Temperature Control . 14Power Down Sequences. 14Normal Power Shut Down Sequence . 14Vivid E9 Shut Down . 14Logiq E9 Shut Down . 15Forced Power Shut Down . 15Unexpected Power Loss . 15Module 3 Operating Modes . 16B-Mode . 16Harmonic Imaging . 16M-Mode . 17Color Flow Doppler Mode . 17Power Doppler. 18Pulsed (PW) Doppler . 18Continuous Wave (CW) Doppler . 18 2016 Conquest Imagingi

GE Logiq E9/Vivid E9 Training ManualOther Modes . 19Module 4 Network Configuration . 20DICOM. 20Prepare for Network Configuration . 20GE Dataflows . 20Vivid E9 Connectivity . 21Vivid E9 Dataflow Descriptions . 21Vivid E9 Dataflow Adjustments . 22Adjusting the Assigned Devices . 23Additional Outputs . 25P1 / P2 / Record button configuration . 25Unlock Patient Record. 26Logiq E9 Connectivity . 26TCPIP . 27Device . 28Service . 28Basic DICOM Preset Parameter Descriptions. 29DICOM Image Storage . 29DICOM Performed Procedure . 30DICOM Print . 30DICOM Query/Retrieve . 32DICOM Storage Commitment . 33DICOM Worklist. 33Standard Print . 35Video Capture . 35Save As . 35Dataflow . 36Print Button Setup. 36Removable Media . 37Formatting Removable Media . 38Miscellaneous . 38Module 5 Preventive Maintenance . 43System Backup. 43Backup Procedure for Vivid E9 . 43Restore Procedure for Vivid E9 . 46Backup Procedure for Logiq E9 . 48Backup and Restore Strategy: Patient Data . 50Cleaning the Air Filters . 51Cleaning the Trackball Vivid E9 (OP-5) . 51Module 6 General Safety Precautions . 53Electrical Safety . 53Electromagnetic Interference . 54Electrostatic Discharge ESD Precautions. 54Fire Safety. 55ii 2016 Conquest Imaging

GE Logiq E9/Vivid E9 Training ManualGeneral Cautions . 55Module 7 Troubleshooting . 56Normal Power On/Boot Sequence . 56Connect AC (mains) Power to the Vivid E9/Logiq E9 . 56Turn System ON . 57Sleep Mode . 57Troubleshooting Log/Image Capture. 58Trouble Shooting Network Issues . 59Trouble Shooting Operator Panel Issues . 61No Audio . 61No Video on LCD Display . 62Wrong Key Activated on the Touch Panel . 62Touch Panel Not Responding . 62Probe Recognition . 62Module 8 Parts Replacement . 64System Power Down . 64Chassis Cover Removal . 64Side Covers . 65Top Cover . 65Foot Rest Bumper . 65Front Cover. 66Back Filter Cover . 66Rear Cover . 67Remove Bulkhead Cover . 68Slots for Bulkhead Cover . 68Remove Handle, Left/Right Top Handle . 69Release Hatches . 69Handle Left Top / Handle Right Top reinstallation. 69Palm Rest Assembly . 70LCD Monitor Replacement . 71Logiq E9 LCD Monitor Replacement . 71LCD Monitor (P/N 5167953) Replacement. 71LCD Monitor V2 (5392293-21) Replacement . 72Vivid E9 LCD Monitor Replacement . 72Replacing the LCD Arm assembly . 73Cables at Bulkhead . 74Install the LCD Arm Assembly . 75LCD Mount Lock Handle . 75Replacing the LCD Cables . 75Third Arm Cover Removal . 76Second Arm Section Cover Removal . 76Install the LCD Cables . 77Feed Cable Through First Arm . 77First (left) Arm Section Midpoint Location . 78Second Arm Section Midpoint Location . 78Feed Cable through Third Arm . 78 2016 Conquest Imagingiii

GE Logiq E9/Vivid E9 Training ManualClip Location Securing Power and Video Cables to Bracket . 79LCD Mount Lock Replacement Procedure . 79Replacing Upper Operator Panel/Touch Panel Assembly . 80Re-Install Upper OP Panel/Touch Panel Assembly . 81OP Grounding . 81Replace Lower Operator Panel . 83View from Below with Drawer Extended . 83Replacing the Vivid E9 Trackball . 84Re-Install the Trackball . 84Remove the Lower Operator Panel Frame . 85Lower Frame Assembly Installation . 86Remove Bulkhead Board . 87Bulkhead Board Screws . 87Re-Install the Bulkhead Board . 87Remove the Bulkhead Plate . 87Re-install the Bulkhead Plate . 88XYZ Buttons and Button Board Replacement . 89Top Console Adjustment Controls . 89XYZ Buttons . 89Buttons Removal Procedure . 90Button IF Board Replacement . 90XYZ Mechanism Frog Legs . 91XY Mechanism Installation Procedure . 92XY Park Lock Replacement . 93XY Park Lock Removal . 93Z-Mechanism replacement . 94Z-Mechanism . 94XYZ Control Assembly Replacement . 95Main Power Suppy Replacement . 96Vivid E9 Main Power Supply Replacement . 96Logiq E9 Main Power Supply Replacement. 97Back End Processor (BEP) . 98Logiq E9 BEP Replacement . 99Vivid E9 BEP Replacement . 102Front End Parts Replacement . 104Vivid E9 Front End Processor (FEP) . 104Module 9 System Adjustments . 107Touch Screen Calibration. 107DC Offset Calibration . 108When to do a DC Offset Calibration . 108DC Calibration Procedure . 108Operator Panel Adjustments . 109Using the Park Lock Properly . 109Normal Operator Panel XY Movement . 110XY Brake Adjustment. 111Release the Park Lock Manually . 111iv 2016 Conquest Imaging

GE Logiq E9/Vivid E9 Training ManualGlossary . 112Acronyms . 115Appendix 1 Network Configuration Worksheets . 118Checklist for Configuring Ultrasound System Network Parameters . 118Print Device Information . 119HIS/RIS Server Information . 120DICOM Devices to Connect to System: . 121Other Needed Information: . 121 2016 Conquest Imagingv

GE Logiq E9/Vivid E9 Training ManualModule 1 IntroductionThis manual is specific to the GE Logiq E9/Vivid E9 systems fieldservice training presented by the Conquest Imaging trainingdepartment. After completing the training, you will: Understand overall system operation. Identify the parts, boards and modules. Understand the role of each component in the system. Be able to perform standard maintenance procedures. Have the knowledge to troubleshoot common problems. Be able to safely access and replace boards and modules. Understand of some of the differences in configuration fordifferent system versions.Other Course OfferingsThis course is one of many ultrasound training courses offered byConquest Imaging.The following are some of our current course offerings: Basic UltrasoundDICOM Standards and NetworksPreventive Maintenance 2016 Conquest Imaging1

GE Logiq E9/Vivid E9 Training Manual Probe Care and HandlingNFPA 99 Electrical SafetyCrash CourseOEM PlatformsYou can use this marginfor taking notes.To see the full descriptions and the scheduling of these courses,please visit our training department website:http://conquestimaging.com/education/Vivid E92 2016 Conquest Imaging

GE Logiq E9/Vivid E9 Training ManualModule 2 System Hardware and TheoryThe goal of the System Hardware and Theory Module is to provideyou with a solid grounding on the purpose of the GE Logiq E9/Vivid E9system’s different components and how they function togetherwithin the system.The Logiq E9 is a general system with the capability of performingcardiovascular, abdominal, urologic, pediatric and women’s healthexams.and has been produced since 2009. The focus of the Vivid E9 iscardiovascular exams. We will use a color coded system to call out thedifferences where necessa

GE Logiq E9/Vivid E9 Training Manual 2016 Conquest Imaging 1 Module 1 Introduction This manual is specific to the GE Logiq E9/Vivid E9 systems field

Related Documents:

for the New Philips Epiq 5/7 Systems Sponsored by: Conquest Imaging . Wednesday, November 18, 2015, 2:00pm ET . b / 5: c / 6: c / 7: d / 8: e / 9: d / 10: c. TechNation would like to thank our sponsor, Conquest Imaging! Conquest Imaging is the largest supplier of ultrasound parts, probes/transducers, probe/transducer repair, training, service .

Conquest 464.3250 S 136.5 Hz Shore Exc / Tours 07.2010 Conquest 457.5625 S 254.1 Hz Hotel Ops 01.2010 Conquest 478.5250 S 100.0 Hz Casino Ops 01.2010 Conquest 459.6500 S No PL Paging System 03.2010 Destiny 457.5250 R 467.7500 I 69.3 Hz Ch.02 03.21.20

your remaining 50% balance payment will be required upon Conquest Vehicles completing production of your KnIGHt XV. Upon completion, a consultant from Conquest Vehicles will contact you to inform you that the vehicle is ready and will assist you with completing the final payment process. At this time, a Conquest Vehicles' consultant will also

1. Medical imaging coordinate naming 2. X-ray medical imaging Projected X-ray imaging Computed tomography (CT) with X-rays 3. Nuclear medical imaging 4. Magnetic resonance imaging (MRI) 5. (Ultrasound imaging covered in previous lecture) Slide 3: Medical imaging coordinates The anatomical terms of location Superior / inferior, left .

Head to Toe Imaging Conference 34th Annual Morton A. Bosniak The Department of Radiology Presents: New York Hilton Midtown December 14–18, 2015 Monday, Dec. 14 Abdominal Imaging & Emergency Imaging Tuesday, Dec. 15 Thoracic Imaging & Cardiac Imaging Wednesday, Dec. 16 Neuroradiology & Pediatric Imaging Thursday, Dec. 17 Musculoskeletal Imaging & Interventional

titles in Radiology. Radiology Books Journals Electronic Resources 2016. 3 Contents 3 Neurologic Imaging 6 Abdominal Imaging 7 Breast Imaging 8 Diagnostic Imaging 9 Pediatric Imaging 10 Thieme eRadiology 11 General Radiology 13 Musculoskeletal Imaging 14 Interventional Radiology 16 RadCases

Conquest stories developed as explanations for the existence of institutions, customs, and physical features observed in later times. Alt and Noth were criticized by the proponents of the Conquest model who claimed that the peaceful infiltration model failed to utilize the result

4 Shaft Capacity in Clay (Alpha Method) Soft-stiff clay Adhesion factors