SYSTEM GUIDEUSG CELEBRATIONTORSION SPRING CEILING SYSTEMSYSTEM GUIDEUSG Celebration Torsion Spring Ceiling System is an engineered design that combines amonolithic appearance with easy access to the plenum through downward accessible panels.USG Celebration Torsion Spring panels provide a clean, no reveal look that completely hides thesuspension system as well as maintain superior alignment throughout the ceiling system. The wellthought-out system is a sensible choice to demonstrate the beauty and precision of your designwhile still providing the ease of usability that the torsion spring system provides.INTRODUCTION2 System OverviewSYSTEM DESIGN345671114FOR MORE INFORMATIONPanel SizesComponentsAssemblyFinishesPerforationsGrid LayoutDetailsTechnical Service800 USG.4YOU (874-4968)Web Siteusg.com or cgcinc.com1

SYSTEM OVERVIEWUSG CELEBRATION TORSIONSPRING CEILING SYSTEMFEATURES AND BENEFITSSIZESMATERIALSUSG Celebration Torsion Spring System allows you to create a monolithic ceiling design that isboth easy to install and easy to maintain. As part of the Celebration family of downward accessibleceiling systems, you would be able to choose from a wide variety of finishes and perforationpatterns. Available in wall-to-wall or cloud designs, the USG Celebration Torsion Spring System isengineered to use multiple panel sizes together to further expand your creative design. Aluminum panels provide a monolithic appearanceFull 90 degree swing-down motion provides easy downward access to plenum areasSpring clip design provides superior alignmentNo revealWind load tested and approved for exterior applications with proper bracing and exterior framing24" x 24", 24" x 48", 24" x 72", 24" x 96", 48" x 48"AluminumSUSPENSION SYSTEMStandard USG Donn Brand DX main tees are used in conjunction with slotted cross tees. Theslotted cross tees are available in 2', 4' and 6' lengths with the 6' cross tees specifically designedfor use with the 24" x 72" panels. USG Donn Brand ZXLA main tees used with slotted ZXA crosstees are recommended for exterior applications.PERIMETER DETAILSUSG Compässo Standard trim may be used with the USG Celebration Torsion Spring ceilingsystem for a finished appearance at exposed edges. Please refer to USG Compässo Standard/Elite(IC309) datasheet for additional information.ACOUSTICAL PERFORMANCEPerforated panels with an Acoustibond sound backer achieve a range of 0.35-0.75 NRC,dependent on the perforation pattern, when installed in an enclosed plenum. Available fiberglassfilled polybags provide even greater acoustical performance.2

PANEL SIZES24" x 24"24" x 48"torsion springtorsion springpanelpanel24" x 72"torsion springpanel24" x 96"torsion springpanel48" x 48"torsion springpanel3

DETAILSCOMPONENTSTorsion Spring with spring cliptorsion springslotted tee forspring insertionslotted cross teeUSG Celebration Torsion Spring panelpanel spring clip2' Cross Tee4' Cross Tee6' Cross TeeTS Trim ClipUSG Compässo Standard4

DETAILSCOMPONENTSM7 Wall AngleF-MoldT-15 Hold Down Clip with Double M7T-15 Hold Down Clip with F-MoldASSEMBLYhanger wire2' cross teemain tees 4'-0" OCUSG Celebration Torsion Spring panel4' slotted cross teetorsion spring5

FINISHESPAINTED METALSFlat White (050)Silver Satin (002)Metallic Oyster (1652)Matte White (3708)Brushed Aluminum (PIA12)Polished Brass (PM21)Polished Chrome (PM61)Satin Chrome (PM614)BeechDark BambooDark CherryLight BambooLight CherryMapleRed OakWalnutMetallic finishes shown2ANODIZED METALS1USG Paraline only;PII—Black Reveal not available with these finishesWOOD TONES3USG Celebration and Panz , 1'x4', 1'x5', 20"x60",2'x2' and 2'x4' panels. Coordinating suspension and/or trim color available.6

FINISHESPlease call 866 528-7089 to request a sample.STANDARD PERFORATIONS1Pattern NumberPerforation PatternOpen Area %5A062Round 1/16" Perforations, 0.25" o.c. (without border)5%A062ARound 1/16" Perforations, 0.25" o.c.5%A062D (Micro perf.)Round .062" Perforations, 0.124" o.c.19%A116Round 15/128" Perforations, 0.354" o.c.17%A188Round 3/16" Perforations, 1" o.c.3%A250Round 1/4" Perforations, 0.5" o.c.39%A5005Round 1/2" Perforations, 0.848" o.c.55%B079Round 5/64" Perforations, 0.312" o.c.6%B125Round 1/8" Perforations, 0.375" o.c.10%B188ARound 3/16" Perforations, 0.312" o.c.33%B197Round 13/64" Perforations, 0.316" o.c.35%B250Round 1/4" Perforations, 0.437" o.c.30%Round 1/4" Perforations, 0.32" o.c.58%B250H (Formerly H250)5B312Round 5/16" Perforations, 0.437" o.c.46%B5005Round 1/2" Perforations, 0.600" o.c.63%C0306Round 1/32" Perforations, 0.197" o.c.1.8%C0622Round 1/16" Perforations, 0.351" o.c.2%C062A 2Round 1/16" Perforations, 0.175" o.c.10%C116Round 15/128" Perforations, 0.344" o.c.8%C188Round 3/16" Perforations, 1.414" o.c.1%C250ARound 1/4" Perforations, 0.65" o.c.12%C3752Round 3/8" Perforations, 1.125" o.c.9%C500Round 1/2" Perforations, 1.5" o.c.9%D2502Square 1/4" Perforations, 0.75" o.c.11%D3752Square 3/8" Perforations, 1.125" o.c.11%D500Square 1/2" Perforations, 1.5" o.c.17%D500D5Square 1/2" Perforations, 0.595" o.c.70%EC25D3Round 1/4" dia. x 1/16" Embossing, 1.18" o.c.; No Perforation0%EC25URound 1/4" dia. x 1/16" Embossing, 1.18" o.c.; No Perforation0%EM25D3Round 1/4" dia. x 1/16" Embossing, 1/4" Perforations, 1.14" o.c.2%EM25U3Round 1/4" dia. x 1/16" Embossing, 1/4" Perforations, 1.14" o.c.2%3Notes1. Refer to IC425 USG Perforations Selection Guide for more information.2. Also standard for USG Geometrix panels.3. 2'x2' USG Celebration and Panz panels only.4. Perforation patterns shown at 75% of actual size. When ordering, please refer to the pattern number for perforation samples(for example, “A062”). (All samples are 6"x6".)5. Panels with an open area 50% offered in 2'x2' only.6. 2' wide USG Celebration Snap-In, Celebration Torsion Spring, Panz and Curvatura panels up to 6' long only.7

METAL PERFORATIONSSTANDARD PERFORATIONS4Pattern No. A062/A062APattern No. A062DPattern No. A116Pattern No. A188Round—1/16" perforations0.25" o.c., 5% open areaRound—0.062" perforations0.124" o.c., 19% open areaMicro perf.Round—15/128" perforations0.354" o.c., 17% open areaRound—3/16" perforations1" o.c., 3% open areaPattern No. A250Pattern No. A500A118A116Pattern No. B079Pattern No. B125Round—5/64" perforationsRound—1/8" perforations0.375" o.c., 10% open areaPattern No. B250Pattern No. B250H(formerly H250)Round—1/4" perforationsRound—1/4" perforations0.32" o.c., 58% open areaA062Round—1/4" perforations0.5" o.c., 39% open areaA250A500Pattern No. B188ARound—3/16" perforationsB188A0.312" o.c., 33% open areaB197Round—1/2" perforations0.848" o.c., 55% open areanot to be used with the USGCurvatura One-DirectionalB079Ceiling SystemPattern No. B197Round—13/64" perforations0.316" o.c., 35% open areaB2500.312" o.c., 6% open areaB1250.437" o.c., 30% open areaH2508

METAL PERFORATIONSSTANDARD PERFORATIONS4B312Pattern No. B312Round—5/16" perforations0.437" o.c., 46% open areaPattern No. B500Pattern No. C030Pattern No. B500Round—1/2" perforationsRound—1/32" perforationsRound—1/16" perforations0.351" o.c., 2% open area0.600" o.c., 63% open area C0620.197" o.c., 1.8% open area032not to be used with the USGCurvatura One-DirectionalCeiling SystemB500C062APattern No. C062APattern No. C116Pattern No. C188Pattern No. C250ARound—1/16" perforationsRound—15/128" perforations0.344" o.c., 8% open areaRound—3/16" perforations1.414" o.c., 1% open areaRound—1/4" perforations0.65" o.c., 12% open areaPattern No. D250Pattern No. D375C1160.175" o.c., 10% open areaPattern No. C375Pattern No. C500Round—3/8" perforations1.125" o.c., 9% open areaD250perforationsRound—1/2"1.5" o.c., 9% open areaC500C375C188C250AD375Square—1/4" perforations0.75" o.c., 11% open areaSquare—3/8" perforations1.125" o.c., 11% open areaNotes1. Do not use with USG Curvatura One-Directional Ceiling System.2. Standard for USG Geometrix panels.3. 2'x2' USG Celebration and Panz panels only.4. USG Perforation patterns shown at 75% of actual size. When ordering, please refer to the pattern number for perforationsamples (for example, “A062”). (All samples are 6"x6".)5. Panels with an open area 50% offered in 2'x2' only.6. 2" wide USG Celebration Snap-In, Celebration Torsion Spring, Panz and Curvatura panels up to 6' long only.9

METAL PERFORATIONSSTANDARD PERFORATIONS4D500EMBOSSING ONLY4EM25DEMBOSSING AND PERFORATIONS4EC25DPattern No. D500Pattern No. B312Square—1/2" perforations1.5" D500Do.c., 17% open areaSquare—1/2" perforations0.595" o.c., 70% open area(70% open area required forsprinklers above ceiling)Pattern No. EM25DPattern No. EM25URound—1/4" dia. x 1/16"embossing 1.18" o.c., noperforationRound—1/4" dia. x 1/16"embossing 1.18" o.c., noperforationFace sideFace sideEM25UPattern No. EC25DPattern No. EC25URound—1/4" perforations1.41" o.c., 2% open areaBlack Acoustibond backerstandardRound—1/4" perforation1.41" o.c., 2% open areaAcoustibond backer notavailableFace sideFace sideEC25U10

GRID LAYOUT2' X 2' LAYOUT TYPICALGRID FRAMING PLANhanger wirehanger wirenotched 4' cross teenotched 4' cross teemain teenotched 4' cross tee2'-0" cross tee2'-0" cross teenotched 4' cross tee2'-0" cross tee2'-0" cross teemain tee2'-0" cross teenotched 4' cross tee2'-0" cross teenotched 4' cross tee2'-0" typnotched 4' cross tee2'-0" typmain teenotched 4' cross tee2' cross teewall moldinghanger wireNotesNotes:1. Reference USG publication Celebration Torsion Spring Installation Guide (IC637) for more information.2.exterior applications,contact IC630,your localUSG representativefor more information.1. ForReferenceUSG publication"TorsionSpring InstallationGuide" for more information.2. For exterior applications, contact your local USG representative for more information.Typical Grid Framing Plan – 2' x 2' Layout11

GRID LAYOUT2' X 4' LAYOUT TYPICALGRID FRAMING PLANhanger wirehanger wirenotched 4' cross teenotched 4' cross teemain teenotched 4' cross teemain teenotched 4' cross teenotched 4' cross teenotched 4' cross tee2'-0" typ.notched 4' cross teenotched 4' cross tee4'-0" typ.main teenotched 4' cross teewall moldinghanger wireNotesNotes:1. Reference USG publication Celebration Torsion Spring Installation Guide (IC637) for more information.2.exterior applications,contact IC630,your localUSG representativefor more information.1. ForReferenceUSG publication"TorsionSpring InstallationGuide" for more information.2. For exterior applications, contact your local USG representative for more information.Typical Grid Framing Plan – 2' x 4' Layout12

2'-0" cross teehanger wire2'-0" cross tee2'-0" cross tee2'-0" cross tee2'-0" cross tee2'-0" cross tee2'-0" cross tee2'-0" cross teemain tee2'-0" cross tee2'-0" cross tee2'-0" cross teenotched 6' cross teenotched 6' cross tee2'-0" typ.notched 6' cross teenotched 6' cross teemain teemain teenotched 6' cross teenotched 6' cross tee2'-0" cross teehanger wirenotched 6' cross teenotched 6' cross tee2'-0" cross tee2' X 6' LAYOUT TYPICALGRID FRAMING PLAN2'-0" cross teeGRID LAYOUT2'-0" typ.6'-0" typ.notched 6' cross tee2' cross teewall moldinghanger wireNotes:NotesReference USGpublicationIC630,"Torsion SpringInstallationfor moreinformation.1.1. de"InstallationGuide(IC637) for more ntactyourUSGlocalUSG representativefor more information.2. ForFor exteriorcontactyour localrepresentativefor more information.Typical Grid Framing Plan – 2' x 6' Layout13

DETAILSCUT PANEL PERIMETER WALLINTERFACE (WITH M7 WALL MOLDINGS)12 ga hanger wire6" max.torsion springM7 wall moldingpop rivetcross teemain teefasten towall framingT-15 hold-down clipM7 wall moldingacousticalbacker (optional)USG CelebrationTM TorsionSpring panel12 ga hanger wiretorsion springpop rivetmainteeM7 wall moldingcrossteefasten towall framingT-15 hold-down clipM7 wall moldingacousticalbacker (optional)USG CelebrationTM TorsionSpring panel14

DETAILSCUT PANEL PERIMETER WALLINTERFACE (WITH F-MOLD)12 ga hanger wire6" max.torsion springF-Moldpop rivetcross teemain teefasten towall framingT-15 hold down clipacousticalbacker (optional)CelebrationTM TorsionSpring panelCut Panel Perimeter Wall Interface12 ga hanger wiretorsion springpop rivetmainteeF-Moldcrossteefasten towall framingT-15 hold down clipacousticalbacker (optional)CelebrationTM TorsionSpring panelCut Panel Perimeter Wall Interface15

DETAILSFULL PANEL AT PERIMETER TRIM12 ga hanger wiremain teeCTS USG Compässo attachment clipcross tee6" or 8"USG CelebrationTMTorsion Spring panelacousticalbacker (optional)12 ga hanger wiremain teecross teetorsion spring clipsacousticalbacker (optional)USG Compässo standard trimCTS USG Compässo attachment clip6" or 8"USG Compässo standard trimUSG CelebrationTMTorsion Spring panel16

DETAILSPANEL AT LIGHT FIXTUREsupport structureabove by othersAttach stabilizer bars to grid. Load offixture and housing to be supportedfrom structure above, typical.cross teemain teePANEL AT SPRINKLERUSG CelebrationTMTorsion Spring panelDo not overtighten Luminairerim clips. Avoid contact withTorsion Spring panels, typical.swing-arm assembly isrecommended to allowcentering in torsion springpanels (support to structureabove), by others12 ga hanger wiremain teecross teesprinkler escutcheon andfield cut by others, typicalCelebrationTM TorsionSpring panel17

DETAILSFULL PANEL ATCROSS TEE12 ga hanger wiremain teecross teetorsion spring clipsacousticalbacker (optional)USG CelebrationTM TorsionSpring panel18

PRODUCT INFORMATIONSee usg.com for the mostup-to-date product information.PRODUCT INFORMATIONData Page: IC622Installation Guide: IC637See usg.com or cgcinc.com for the most up-to-date productinformation.CUSTOMER SERVICEUSG 800 950-3839CGC 800 387-2690INSTALLATIONMust be installed in compliance with ASTM C636, ASTM E580,CISCA and standard industry practices, within all applicable coderequirements. Alternative assemblies and installation methods maybe utilized when approved by the authority having jurisdiction.USG recommends checking with the authority having jurisdictionprior to designing and installing a suspended ceiling system.TECHNICAL SERVICE800 USG.4YOU (874-4968)CODE COMPLIANCEThe information presented is correct to the best of our knowledgeat the date of issuance. Because codes continue to evolve, checkwith a local official prior to designing and installing a ceilingsystem. Other restrictions and exemptions may cgcdesignstudio.comNOTICEWe shall not be liable for incidental and consequential damages,directly or indirectly sustained, nor for any loss caused byapplication of these goods not in accordance with current printedinstructions or for other than the intended use. Our liability isexpressly limited to replacement of defective goods. Any claimshall be deemed waived unless made in writing to us withinthirty (30) days from date it was or reasonably should have beendiscovered.IC638/2-20 2020 USG Corporation and/or its affiliates. All rights reserved.The trademarks USG, ACOUSTIBOND CELEBRATION, COMPÄSSO, CURVATURA, DONN, DX, GEOMETRIX, PANZ, PARALINE,ZXLA, IT'S YOUR WORLD. BUILD IT., the USG logo, the design elements and colors, and related marks are trademarks of USGCorporation or its affiliates.NOTICEThe information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for anyerrors that may inadvertently appear in this document.COLOR VARIATIONSSome commercially acceptable color variation may occurbetween lots and between different size canopies of thesame color.SEISMIC APPLICATIONSRefer to Seismic Technical Guide, Specialty DecorativeCeilings (SC2494) for more information on architecturalcomponents.SAFETY FIRST!Follow good safety/industrial hygiene practices duringinstallation. Wear appropriate personal protective equipment. Read SDS and literature before specification andinstallation.WARRANTYOne (1) year limited warranty. See USG Ceilings CommercialApplication Warranty (SC2102) for additional details. ForCanadian product needs, please contact your local salesrepresentative.

SYSTEM GUIDE 1 USG CELEBRATION TORSION SPRING CEILING SYSTEM USG Celebration Torsion Spring Ceiling System is an engineered design that combines a monolithic appearance with easy access to the plenum through downward accessible panels. USG Celebration Torsion Spring panels

Related Documents:

SYSTEM GUIDE 1 USG CELEBRATION TORSION SPRING CEILING SYSTEM USG Celebration Torsion Spring Ceiling System is an engineered design that combines a monolithic appearance with easy access to the plenum through downward accessib le panels. USG Celebration Torsion Spring panels

Software Vantage Report, ZyWALL IPSec VPN Client, SSL Win/Mac OS Garanzia 3 Anni 5 Anni USG 1900 USG 1100 USG 310 USG 210 USG 40/40W USG 60/60W USG 110 USG 20/20W 5 10 10 25 25 50 50 75 75 200 200

USG Celebration Torsion Spring Ceiling System 10 Step 1: Determine the location of the hanger wires. For any type of cloud system, this depends on the size and coniguration. To ensu re proper hanger wire location, refer to USG Celebration Torsion Spring Systems Guide (IC638.) In ca

ZyWALL USG Series Model USG 20 USG 20W USG 50 USG 100 USG 100-PLUS USG 200 . Card slot--- 1 - 1 System Capacity & Performance*1 SPI firewall throughput*2 (Mbps) 175 175 225 225 600 250 VPN throughput (AES)*3 (Mbps) 75 75 90 90 150 90 UTM throughput (AV IDP)*4 (Mbps) - - 30 30 30 40 . t Support Kaspersky

usg eclipse pÁg. 7 usg olympia micro pÁg. 7 usg millenia pÁg. 7 alto diseÑo usg pÁg. 8 nuevos productos k m sistema de muro elevador pÁg. 11 usg levelrock pÁg. 11 usg roofing pÁg. 12 sistema acÚstico pÁg. 13 los productos usg inc

8 32 28 Class A 0.70 36 0.84 1.7 Low 72% USG Frost 414 USG CHEYENNE 156 SL 2'x2'x3/4" Paper-Back 8 32 28 Class A 0.65 35 0.70 1.7 Low — 72% USG Glacier Basic 707 USG SANDRIFT R808 SL 2'x2'x3/4" 8 32 28 Class A 0.70 38 0.83 1.7 Low 72% USG Sandrift

69 USG DRYWALL SUSPENSION SYSTEM Ceiling Grid Framing System For More Information echnical T Servic e usg.com800.USG.4YOU Website . Page 2 intentionally left blank. DESCRIPTION USG Paraline II Linear Metal Pans combine a unique linear appearance with the strength and corros

Accounting records will be maintained in accordance with ORGANIZATION NAME's fiscal year, ie. January 1-December 31. 2. The double-entry method of bookkeeping and the accrual method of accounting shall be used. 3. ORGANIZATION NAME's computer system will be utilized in maintaining and creating the general ledger, all related journals and financial reports. 4. All revenues, support and expenses .