INTERNATIONAL ISO This Is A Preview Of ISO 10360-2:2009 .

3y ago
78 Views
13 Downloads
238.22 KB
6 Pages
Last View : 4d ago
Last Download : 3m ago
Upload by : Milena Petrie
Transcription

INTERNATIONALISOThis is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.STANDARD10360-2Third edition2009-12-01Geometrical product specifications(GPS) — Acceptance and reverificationtests for coordinate measuring machines(CMM) —Part 2:CMMs used for measuring lineardimensionsSpécification géométrique des produits (GPS) — Essais de réception etde vérification périodique des machines à mesurer tridimensionnelles(MMT) —Partie 2: MMT utilisées pour les mesures de dimensions linéairesReference numberISO 10360-2:2009(E) ISO 2009

ISO 10360-2:2009(E)This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.PDF disclaimerThis PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed butshall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. Indownloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariataccepts no liability in this area.Adobe is a trademark of Adobe Systems Incorporated.Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creationparameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. Inthe unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.COPYRIGHT PROTECTED DOCUMENT ISO 2009All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below orISO's member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. 41 22 749 01 11Fax 41 22 749 09 47E-mail copyright@iso.orgWeb www.iso.orgPublished in Switzerlandii ISO 2009 – All rights reserved

ISO 10360-2:2009(E)This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.ContentsPageForeword .vIntroduction.vi1Scope .12Normative references.13Terms and definitions .24Symbols.455.15.25.35.45.5Environmental and metrological requirements.4Environmental conditions .4Operating conditions .5Length measurement error, EL .5Repeatability range of the length measurement error, R0 .5Workpiece loading effects 5.36.66.6.16.6.2Acceptance tests and reverification tests .6General .6Principle.6Length measurement error with zero ram axis stylus tip offset, E0 .7General .7Measuring equipment .7Procedure .8Derivation of test results .9Repeatability range of the length measurement error, R0 .9Length measurement error with ram axis stylus tip offset of 150 mm, E150 .10Measuring equipment .10Procedure .10Derivation of test results .12Dual ram CMMs.12Simplex operating mode.12Duplex operating mode.1277.17.1.17.1.27.2Compliance with specifications.13Acceptance test .13Acceptance criteria .13Data rejection and repeated measurements.14Reverification test .1488.18.28.3Applications .14Acceptance test .14Reverification test .15Interim check .159Indication in product documentation and data sheets.15Annex A (informative) Interim check.16Annex B (normative) Artefacts that represent a calibrated test length.18Annex C (informative) Alignment of gauges .23Annex D (normative) Mathematical adjustments to low CTE artefacts.25Annex E (informative) Location of the single stylus probing test .27 ISO 2009 – All rights reservediii

ISO 10360-2:2009(E)This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.Annex F (informative) Relation to the GPS matrix model .28Bibliography .29iv ISO 2009 – All rights reserved

ISO 10360-2:2009(E)This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies(ISO member bodies). The work of preparing International Standards is normally carried out through ISOtechnical committees. Each member body interested in a subject for which a technical committee has beenestablished has the right to be represented on that committee. International organizations, governmental andnon-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with theInternational Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main task of technical committees is to prepare International Standards. Draft International Standardsadopted by the technical committees are circulated to the member bodies for voting. Publication as anInternational Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be the subject of patentrights. ISO shall not be held responsible for identifying any or all such patent rights.ISO 10360-2 was prepared by Technical Committee ISO/TC 213, Dimensional and geometrical productspecifications and verification.This third edition cancels and replaces the second edition (ISO 10360-2:2001), which has been technicallyrevised.ISO 10360 consists of the following parts, under the general title Geometrical product specifications (GPS) —Acceptance and reverification tests for coordinate measuring machines (CMM): Part 1: Vocabulary Part 2: CMMs used for measuring linear dimensions Part 3: CMMs with the axis of a rotary table as the fourth axis Part 4: CMMs used in scanning measuring mode Part 5: CMMs using single and multiple stylus contacting probing systems Part 6: Estimation of errors in computing Gaussian associated features Part 7: CMMs equipped with imaging probing systems ISO 2009 – All rights reservedv

ISO 10360-2:2009(E)This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.IntroductionThis part of ISO 10360 is a geometrical product specification (GPS) standard and is to be regarded as ageneral GPS standard (see ISO/TR 14638). It influences link 5 of the chains of standards on size, distance,radius, angle, form, orientation, location, run-out and datums. For more detailed information of the relation ofthis part of ISO 10360 to other standards and the GPS matrix model, see Annex F.The tests of this part of ISO 10360 have three technical objectives:1)to test the error of indication of a calibrated test length using a probing system without any ram axis stylustip offset;2)to test the error of indication of a calibrated test length using a probing system with a specified ram axisstylus tip offset; and3)to test the repeatability of measuring a calibrated test length.The benefits of these tests are that the measured result has a direct traceability to the unit length, the metre,and that it gives information on how the CMM will perform on similar length measurements.Clause 3 of this part of ISO 10360 contains definitions that supersede similar definitions in ISO 10360-1:2000.The revised definitions are required to avoid an ambiguity that would otherwise have been introduced with thisissue of ISO 10360-2. Also, definition 3.6 supersedes effectively an identical definition in ISO 10360-1:2000because the symbols used have been revised and expanded for clarification.vi ISO 2009 – All rights reserved

issue of ISO 10360-2. Also, definition 3.6 supersedes effectively an identical definition in ISO 10360-1:2000 because the symbols used have been revised and expanded for clarification. This is a preview of "ISO 10360-2:2009". Click here to purchase the full version from the ANSI store.

Related Documents:

ISO 10381-1:2002 da ISO 10381-2:2002 da ISO 10381-3:2001 da ISO 10381-4:2003 da ISO 10381-5:2001 da ISO 10381-6:1993 da ISO 10381-7:2005 ne ISO 10381-8:2006 ne ISO/DIS 18512:2006 ne ISO 5667-13 da ISO 5667-15 da Priprema uzoraka za laboratorijske analize u skladu s normama: HRN ISO 11464:2004 ne ISO 14507:2003 ne ISO/DIS 16720:2005 ne

ISO 10771-1 ISO 16860 ISO 16889 ISO 18413 ISO 23181 ISO 2941 ISO 2942 ISO 2943 ISO 3724 ISO 3968 ISO 4405 ISO 4406 ISO 4407 ISO 16232-7 DIN 51777 PASSION TO PERFORM PASSION TO PERFORM www.mp ltri.com HEADQUARTERS MP Filtri S.p.A. Via 1 Maggio, 3 20060 Pessano con Bornago (MI) Italy 39 02 957

ISO 18400-107, ISO 18400-202, ISO 18400-203 and ISO 18400-206, cancels and replaces the first editions of ISO 10381-1:2002, ISO 10381-4:2003, ISO 10381-5:2005, ISO 10381-6:2009 and ISO 10381-8:2006, which have been structurally and technically revised. The new ISO 18400 series is based on a modular structure and cannot be compared to the ISO 10381

The DIN Standards corresponding to the International Standards referred to in clause 2 and in the bibliog-raphy of the EN are as follows: ISO Standard DIN Standard ISO 225 DIN EN 20225 ISO 724 DIN ISO 724 ISO 898-1 DIN EN ISO 898-1 ISO 3269 DIN EN ISO 3269 ISO 3506-1 DIN EN ISO 3506-1 ISO 4042 DIN

ISO 8402 was published in 1986, with ISO 9000, ISO 9001, ISO 9002, ISO 9003 and ISO 9004 being published in 1987. Further feedback indicated that there was a need to provide users with application guidance for implementing ISO 9001, ISO 9002 and ISO 9003. It was then agreed to re-number ISO 9000 as ISO 9000-1, and to develop ISO 9000-2 as the .

ISO 37120. PAS 181/ISO 37106. PAS 183 – data sharing & IT. PAS 184. PAS 185. a security-minded approach. ISO/IEC 30145 . reference architecture. ISO/IEC . 30146. ISO 37151. ISO 37153. ISO 37156. Data exchange. ISO 37154. ISO 37157. ISO 37158. Monitor and analyse . data. PAS 182/ ISO/IEC 30182. PD 8101. PAS 212. Hypercat. BIM. PAS 184. Role of .

ISO 14644‐1 FEDERAL STANDARD 209E ISO Class English Metric ISO 1 ISO 2 ISO 31 M1.5 ISO 410 M2.5 ISO 5 100 M3.5 ISO 6 1,000 M4.5 ISO 7 10,000 M5.5 ISO 8 100,000 M6.5 ISO 9N/A N/A Standard 209E classifications are out‐of‐date. This standard was officially retired in 2001. Increasing Cleanliness

ISO 45001 Established:-ISO 10006 -Quality in project management-ISO 10007 -Configuration management-ISO 15161 -Food safety (ISO 9000 and HACCP)-ISO 19600 -Compliance management systems-ISO 20000 -IT services-ISO 20121 -Sustainable event management-ISO 20400 -Sustainable purchasing-ISO 22000 -Food safety-ISO 22301 -Business continuity management