CONTINENTAL HYDRAULICSVSD03M*-S SOLENOID OPERATED .

3y ago
32 Views
2 Downloads
2.39 MB
12 Pages
Last View : 8d ago
Last Download : 3m ago
Upload by : Luis Waller
Transcription

SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES4895 12th Avenue East, Shakopee, MN 55379 / continentalhydraulics.com / 952-895-6400VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESVSD03M*-SCONTINENTAL HYDRAULICS

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESDURABLEVSD03M*-SSOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESDESCRIPTIONThese valves conform to NFPA D03 and ISO 4401 mountingstandards. As the valve spool shifts, the spool lands cross-over thevalve body ports. This can produce high instantaneous flow rates.The anti-shock valve provides a slow spool movement; slower thanthat of a standard directional valve. This results in reduction orelimination of hydraulic system shock produced by the spoolmovement and high flow rates.TYPICAL PERFORMANCE SPECIFICATIONSP - A - B Ports5000 psi350 barT Port3000 psi210 bar20 gpm76 l/minMAXIMUMOPERATINGPRESSUREFLOW RATENFPA D03ISO 4401-03-02-0-03MOUNTING SURFACEMAXIMUMWEIGHTDC4.6 lbs2.1 kgAmbient- 4 to 130 F-20 to 54 CFluid- 4 to 180 F-20 to 82 CRange60 -1900 SUS10 - 400 cSt120 SUS25 cStRANGE TEMPERATURESFLUID VISCOSITYRecommendedFLUID CONTAMINATION2WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COMISO 4406:1999 Class 20/18/15

IDENTIFICATION CODE-S--L-DESIGN LETTERSOLENOIDS - See the codes on page 9FUNCTION1Single Solenoid2 PositionSpring Offset3MECHANICALOMIT IF NOT REQUIREDSEALABuna (STD)GVitonSpool TypeSee Next PageRSingle Solenoid Operator At‘B’ Port End.WDWash-DownCONNECTION BOX OPTIONSOMIT IF NOT REQUIREDSee the codes on page 8ELECTRICAL OPTIONOMITPlug-in terminalsolenoids or lead wiresBConnection box withterminal posts and lightsVSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESVSD03M -Dual Solenoid3 PositionSpring Centered5Single Solenoid2 PositionSpring Centered9Single Operator2 Position - 3 WaySpring OffsetTYPICAL ORDERING ALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM3

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESSPOOLSNAMESYMBOLFUNCTIONCENTER POSITIONCROSSOVERFUNCTION MATCHINGAAll ports blockedAll ports blocked1A1All ports blockedP B and A T restricted orP A and B T restricted3AC-08All ports blockedAll ports blocked3AC-16All ports blockedAll ports blocked3AC-26All ports blockedAll ports blocked3B1All ports openAll ports open1, 3F1P blocked,A and B restricted to TP blocked,A or B restricted to T3, 5FC-08P blocked,A and B restricted to TAll ports blocked3FC-16P blocked,A and B restricted to TAll ports blocked3FC-26P blocked,A and B restricted to TAll ports blocked3L1P TA and B blockedAll ports open, restricted3, 5X-All ports blocked9These are the standard configurations. Contact Continental Hydraulics for special versions.4WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

DCENTERP AP BA TB TP TA, A12233B11332L444439X3310700FLOW CURVE NUMBER5520104015206076Q[gpm][l/min]PERFORMANCE CURVEDC VOLTAGECURVESPOOL1A12L13B1, 9X4F153AC-26, 3FC-2663AC-16, 3FC-1673AC-08, 3FC-0881A, 1B1SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COMVSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESPRESSURE DROPS P-Q(OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70 F - 50 C)5

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESOVERALL AND MOUNTING DIMENSIONS - CONNECTION BOX VERSIONVSD03M, 3*Dimensions in mm [IN]Connection BoxManual OverrideIntegrated in theTube.SOL. ‘B’Coil RemovalSpaceMountingsurface withsealing rings:4 pcs. AS568-01290 Shore AVSD03M-1*, 5*, 9*Manual OverrideIntegrated in theTube.SOL. ‘B’Coil RemovalSpace6WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COMSOL. ‘A’

OVERALL AND MOUNTING DIMENSIONS - DIN STYLE VERSIONDimensions in mm [IN]Coil with DIN style shape(DIN 43650) ConnectorManualOverrideIntegratedin the Tube.SOL. ‘B’Coil RemovalSpaceSOL. ‘A’VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESVSD03M, 3*Mounting surfacewith sealingrings: 4 pcs.AS568-012 90 Shore AVSD03M-1*, 5*, 9*ManualOverrideIntegratedin the Tube.Coil RemovalSpaceSALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM7

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESELECTRICAL CHARACTERISTICSValves are available with an electrical connection box or with DIN 43650 solenoids, Deutsch DT04 or leadwires are also available.CONNECTION BOX OPTIONSTo simplify the connections and prevent wiring mistakes, we offer the option of connection boxes with quickconnect pin receptacles, already wired.Valves are available with receptacles on solenoid side ‘A’ or ‘B’ and several connector styles.Below are the codes to be included in the box ‘option’ of the ordering code, depending on theversion you choose.Wiring diagrams below shows the standard connections for 3-pin, 4-pin and 5-pin connectors. Thecommercially available mating “female” connector are not included.CODEPIN5A55H53A33H34A4D4A444D44SHAPEPORT ENDNOTESASingle and DualSolenoidMale MiniMale MiniBASingle Solenoid OnlyBAMale MicroADifferent Wiring.See Schematics.BB5 PIN RECEPTACLEMale mini receptacles conform toNFPA/T3.5.29 R1 - 2007 used withsingle or double solenoid valve.26 mm [1” ] Wrench3 PIN RECEPTACLEMale mini receptacles conformto NFPA/T3.5.29 R1 - 2007 usedwith single solenoid valve.12345Lead to Solenoid BLead to Solenoid AGround Lead (Green)Lead to Solenoid ALead to Solenoid B123Ground Lead (Green)Lead to SolenoidLead to Solenoid12344A & 4BrownLead to Solenoid AWhiteNo ConnectionBlue Common Lead to Sol. A & BBlackLead to Solendoid B26 mm [1” ] Wrench4 PIN RECEPTACLEMale micro receptacles (M12x1thread) used with DC valve only.23 mm [7/8] Wrench8WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM1234D4A & D4BrownNo ConnectionWhiteLead to Solenoid ABlue Common Lead to Sol. A & BBlackLead to Solendoid B

SOLENOIDSPLUG-IN TERMINAL SOLENOIDDIN 43650This solenoid has three terminal posts. Use bi-polar connectors that meet ISO 4400 / DIN 43650(EN 175301-803). Protection against atmospheric agent: IP 65DEUTSCH DT04 MALELEAD WIRES6 inch length, protection against atmospheric agent: IP 67DEUTSCH DT04 MALEProtection against atmospheric agent: IP 69Connectors must be ordered separately.LEAD WIRESCONNECTION BOX SOLENOIDSThis is a two-pin solenoid which connects to the circuit board. Wiring is done on the terminal stripinside the box.DINCONNECTIONCODELEAD ECTIONCODEVOLTAGE& FREQ.[VOLT - HERTZ]VOLTAGELIMITS[MIN - MAX]RESISTANCE WER[W]4224K424K77024 V DC21 - 2619.21.251.25304412K412K77512 V DC10 - 134.82.52.530VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESListed below are the types of solenoids available and the numbers to be added in the solenoid box on page 3.WASHDOWN OPTION (CODE WD)The wash-down option with the electrical box is designed for an IP65 rating. This option uses a special coverwithout the mounting bolt access holes and uses silicone sealant to help seal between the coil and core tube.The DIN, Deutsch and lead wire coils versions of the wash-down option uses silicone sealant to help sealbetween the coil and core tube.SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM9

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESAPPLICATION DATAFLUIDSAll pressure drops shown on these data pages are based on 170 SUS fluid viscosity and 0.87 specific gravity.For any other specific gravity (G1) the pressure drop ( P) will be approx. P1 P (G1/G). See the chart forother 1.721.83MULTIPIERUse mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBRseals. For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluidsuch as HFA, HFB, HFC, please consult our technical department.Using fluids at temperatures higher than 180 degrees F causes the accelerated degradation of seals as wellas degradation of the fluids physical and chemical properties.From a safety standpoint, temperatures above 130 degrees F are not recommended.RANGE TEMPERATURES:FLUID VISCOSITYFLUID CONTAMINATIONAmbient- 4 to 130 F-20 to 54 CFluid- 4 to 180 F-20 to 82 CRange60 -1900 SUS10 - 400 cSt120 SUS25 cStRecommendedISO 4406:1999 Class 20/18/15INSTALLATIONValves with centering and return springs can be mounted in any position without impairing correct operation.Valves with mechanical detent should have horizontal mounting.Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to orbetter than those indicated in the relative symbols. If minimum values are not observed, fluid can easily leakbetween the valve and support surface.SEAL KITBuna Seal Kit1013326Viton Seal Sit1013327BOLT KITVSD03M10WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM121472

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES11SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVESABOUT CONTINENTAL HYDRAULICSRugged, durable, high-performance, efficient—the reason Continental Hydraulics’ products are used insome of the most challenging applications across the globe. With a commitment to quality customersupport and innovative engineering, Continental’s pumps, valves, power units, mobile and customproducts deliver what the markets demand. Continental has been serving the food production, brickand block, wood products, automotive and machine tool industries since 1962. Learn how ourproducts survive some of the most harsh environments.SALES@CONTHYD.COM4895 12th Avenue East, Shakopee, MN 55379 / continentalhydraulics.com / 952-895-6400FORM NO. 1015682. REV. 01/2013. 2012 CONTINENTAL HYDRAULICS. ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT NOTICE.

VSD03M*-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES VSD03M*-S SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES DESCRIPTION These valves conform to NFPA D03 and ISO 4401 mounting standards. As the valve spool shifts, the spool lands cross-over the valve body ports. This can produce high instantaneous flow rates.

Related Documents:

LVM09/090 2/3 port direct operated solenoid Cv 0.018 139 LVM10/100 2/3 port direct operated solenoid Cv 0.03 0.04 139 LVM15/150 & -20/200 2/3 port direct operated solenoid valve Cv 0.015 0.065 140 VDW10, -20 & -30 2/2 solenoid Cv 0.03 0.44 141 VDW200 & -300 3/2 solenoid Cv 0.03 0.44 142 VCA solenoid valve Cv 0.33 2.1 143 N

S - 5,20 bar (75 psi) check Solenoid Energization Identity Blank - Standard arrangement for ANSI B93.9 (i.e. energize solenoid A to follow flow P to A). V - Solenoid identification determined by position of solenoid (i.e. solenoid A at port A end/solenoid B at port B end). Note 4 and 8 type spools are always V. Solenoid

Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valve and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the .

DC-41DT 12V DC Solenoid Operated Power Up/Power Down . . . . . 99 DC-50SF 12V DC Manual Operated Power Up/Power Down . . . . . 100 DC-60SF 12V DC Solenoid Operated Power Up/Power Down . . . . 101 DC-62SF 12V DC Solenoid Operated Dual Power Up/Power Down . . 102 DC-70SF 12V DC Solenoid Operated Power Up/Power Down . . . . 103

LAPPED SPOOL & SLEEVE, PILOT OPERATED SOLENOID VALVES PM Series The solenoid operated air valves of this series are types with an internal-pilot-type metal seal . 3/5-PORT PAILOT OPERATED SOLENOID VALVE PM25 series �P.26

135.5 147.5 Solenoid operated MFS-O2 ORDERING CODE Solenoid operated modular type. FNC G 0 2 * * * One-way controlled FNC. THF Valve size Voltage for coil Cam operated FKC or Roller operated FYC Controller type of FKC Solenoid controlled FSC. SF. SDF Solenoid modular MFS. FSC-O2 FSC-O3 MFS-O3

Manual 36541 Solenoid Troubleshooting Guide Woodward 1 Chapter 1. General Information Solenoid Operation Single Coil Solenoid A solenoid is a device that converts electrical energy into mechanical force. The basic single coil solenoid is made of a free moving steel plunger that sits within a wound coil of copper wire.

Algae: (11L) 2. Algae: General characters, economic importance and Classification (Chapman and Chapman, 1973) up to classes. 03L . 3. Study of life cycle of algae with reference to taxonomic position, occurrence, thallus structure, and reproduction of Nostoc, Chara, Sargassum and Batrachospermum . 08 L.