SPLIT-TYPE AIR CONDITIONERSNatural ComfortForEverybodyR22POWER CEILING CASSETTECEILING SUSPENDEDWALL MOUNTEDCEILING CONCEALED

P R O D U C TL I N E - U P2.5hp3hpPLH-3AAKPLH-AAKPower ceiling cassettePKH-3FAKPKH-FAKWall mountedPCH-3GAKPCH-GAKCeiling -3YKAPEH-EAKCeiling concealedOUTDOOR UNIT*PUH-3VKA is only for PEH series.1

4hp5hp6hpPLH-4AAKPLH-5AAKPLH-6AAKRemote YKSAPUH-5YKSAPUH-6YKSA2

The MEQ DifferenceHigh performance, low power consumption,and excellent reliability.In today’s competitive environment, simply meeting industry standards, howeverstringent, is not enough. Our aim is to exceed them. That’s why when it comes tocomfort, efficiency and durability: Mitsubishi Electric offers you a distinctive advantage.We call it MEQ — Mitsubishi Electric Quality. And it's a new benchmark that resultsin leading edge products, such as air conditioners that consume minimal power andprotect your investment with a long operational lifespan. You can also enjoy superbreliability, as they’re built to endure the punishment of extreme weather conditionsyear in and year out.Mitsubishi Electric OffersThree Important Advantages3ComfortEfficiencyDurabilityTrue Comfort is Yours toEnjoy with Our Line-upOptimum Cost Performanceand Energy SavingsRugged Construction, RigorousTesting, Long-lasting OperationWe create products designed toensure that you and your surroundingwill always be in a perfect harmony.Whichever model from our Mr. SLIMline-up you may choose for commercial use in restaurants, stores, oroffices will be your guarantee ofexceptional comfort in every and alloperating condition.MEQ results in air conditioners thatare rated among the best in theindustry in terms of quality and energyefficiency. We strive for a perfect balance of performance, reliability, lowpower consumption and long operational life span. This is complemented by continuous introduction of newtechnologies and components thatfurther reduce energy requirementsand improve eco-friendliness.MEQ is behind a mindset that goes toextremes to ensure higher qualityproducts that protect the initialinvestment over years of reliable service. We subject our indoor andoutdoor units to rigorous durabilitytesting, including harsher temperature extremes than likely foundanywhere in the world.

The First Choicefor Any and All ApplicationsWhatever your requirements may be, Mitsubishi Electric offers advancedsplit-type heat pumps perfect for any interior, any need. Significantlydecreased noise levels enhance comfort while a long list of convenientfeatures allow for easy installation and far less maintenance. A variety ofsystem control configurations plus twin multi operation — where multipleindoor units can be connected to a single outdoor unit — makeour units the first choice for the diverse applications of today.New Remote ControllerRenovating air conditioning communicationby advanced MA Remote Controller newly developedDot Liquid Crystal DisplayMulti-language DisplayAcknowledging the operation and control status at a glance.The large size display upgrades visual acknowledgementcapability. The operation and control status can be understoodMultiIanguagepromptly.Display example [Operation mode]8 languagescan be displayed.Display can be switched over for 8 kinds nch][Russian][Chinese][Japanese]Dot liquid crystal display sectionOperation Control FunctionLimiting the settemperature rangeAir conditioning operationalways within a limitedtemperature rangeAuto Off timerAutomatic turning off ofair conditioning operationOperation lockingPreventing the randommodification of settingWeekly TimerThe function of the weekly timer equipped can change the settemperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day.4

Mr. SLIM New A/K Control System ConfigurationControl functionSystem configurationFeaturesNecessary parts & equipment1Group control1. with 1 Indoor UnitOutdoor UnitCombined2. Remote/localcontrolDistantControllerPanelOperation with3. 2 remotecontrollersIndividual4. control fromdistant roomRelayBoxAdapterRemoteControllerIndoor Unit Sequential start adaptable Same mode operation MAC-397IF-E(one for each outdoor unit) Maximum no. of units connectable pergroup: 16-refrigerant (Outdoor 16 sets) Simultaneous ON/OFF remote Operation can be switched betweenthe distant controller panel andhandheld controller 2 remote controllers can be connectedto one group Additional remote controller (option) Control with the latest commandRemoteControllerIndoor UnitRemoteControllerIndoor Unit Extension of remote controller cord(MAX. 500m) Weekly timer operation possible asstandard (7 days-8 patterns)5. TimeroperationOperation byexternal signal Pulse signal receivablePowerSupplyPower failure7. automaticrecoveryConnection of8.remote display5 Remote controller cord (on-site)— Optional adapter allows operation with Timer adapter PAC-SE55RA-Etimer sold on the market(connect to CN32 on indoor circuit board) Static signal receivable6. Timer adapter PAC-SE55RA-E(connect to CN32 on indoor circuit board) Relay box (on-site) Returns to the state before powerfailure as standardIndoor ntrollerAdapterIndoor Unit Connectable to display panel in thefield adapter Timer adapter PAC-SE55RA-E(connect to CN32 on indoor circuit board) Multiple remote controller adpterPAC-725AD(connect to CN51 on indoor circuit board) Function setting by remote controller Multiple remote controller adpterPAC-725AD(connect to CN51 on indoor circuit board) Relay OMRON made LY-1 (DC12V)PAC-SE55RA-EMAC-397IF-EPAC-725ADTimer AdapterMA & Control Terminal InterfaceMultiple Remote Controller Adapter(10 units of PAC-SA88HA-E)

Twin Multi OperationTwo indoor units can be connected to a single outdoor unitINDOOR UNITINDOOR UNITand all units can be operated simultaneously from a singleremote controller using the optional multi-distribution pipe(only indoor units of the same capacity and type can beconnected).Outdoor Unit and Twin-Multi CombinationsApplicable indoor -3EAKMulti-Distribution PipeOutdoor unitPUH-5YKSAPUH-6YKSAMulti-distribution pipeTwin-multi50:502.5 2.53 3SDD-50S-ENote The capacity of both indoor units must be identical. Different types of indoor units with identical capacities can beconnected. The height difference between both indoor units must be 1meter orless.OUTDOOR UNIT When two units are connected, the main unit can be used to controlthe operation of all units.Mr. SLIM Convenient Remote ControllerAdvanced MA remote controllerWired remote controller*Stylish wireless remote controller with all the latest programming featuresWireless remote controller for PLH-AAK FAN SPEED SELECT button Fan speed indicatorUsed to change fan speed.Displays the fan speed setting(HIGH or LOW). VANE CONTROL buttonUsed to change airflow direction. MODE SELECTION buttonUsed to select operating modes —Cool, Dry, and Heat, and Auto. HOUR and MINUTEbuttonsUsed to set the time and timer settings. TIMER button/RESET button TIMER CONTROL buttons DOT LIQUID CRYSTAL display MULTI-LANGUAGE display OPERATION CONTROL functionSTOP (OFF timer): When this function isactivated, the air conditioner will automatically stop at the preset time.START (ON timer): When this function isactivated, the air conditioner will automatically start at the preset time. WEEKLY TIMER*Please refer to page 4.6

POWER CEILING CASSETTEPLH-AAKS E R I E SPLH-3AAKPLH-4AAKPLH-5AAKPLH-6AAKDesign uniformity improves installation flexibilityFrom the smallest 3HP unit to the largest 6HP model, the new highpower ceiling cassettes offer a uniformly square 950 x 950mm widthand depth design. Thanks to the uniformity of the panel size, planningfor unit positioning in any room is enhanced and the installation of different capacity models within the same floor space is made possible.Unit height of only 258mm [PLH-3]The new high-power ceiling cassette modelsboast slim body height for smoothand aesthetic installationeven in limitedceiling plenumapplications.PLH-3AAK258mm(40mm less thanconventional models)PLH-4/5/6AAK298mmAutomatic vane shutterWhen the air conditioner is not operating, the vane shutter* closes automatically to conceal the air outlet andcreate an aesthetically appealing flatsurface.Vane shutter closes automaticallyDuring operationWhen turned off* This feature will not activate when the vane is set atfixed position.Wide-flow air outletINDEXSpecifications .p.11Option .p.13The new high-power ceilingcassettes offer a wide-flow airoutlet that enables effective air conditioning of atrium-type ceilings upto 4.2 meters in height.Ideal for highceiling applicationsThe demands of highas high asceiling applications suchas halls, showrooms or(PLH-4/5/6)shopping malls can nowbe fully answered thanks to this powerful yet highlyefficient airflow. 4-way high ceiling 24.2m 3-way standard3.6m4.2m 4-way standard3.2mSpecifications according to ceiling height and number of ventsPLH-3PLH-4/5/6StandardHigh ceiling 1High ceiling 2StandardHigh ceiling 1High ceiling ay3.33.5—4.04.2—* Optional air outlet shutter plate (PAC-SG06SP-E) is necessary for two- or three-way airflow settings.Features at-a-glanceInstallation & Maintenance Chargeless system Compact design Drain water lift-up (850mm) Handy corner-pocket Long-life filter (2500 hrs.) Self-diagnostic function Filter indicator(For wired remote controller) Flockless vanes7Comfort Auto-angle airflow Versatile airflow 72 airflow patterns Smudge/draft free High ceiling application Computerized dehumidifier Quiet operation Bacteria- and mold-resistant fiterOthers System control Twin-multi operation Auto vane shutter Auto restart Fresh air intake Outdoor unit operatingrange up to 46ºC

WALL MOUNTEDAuto-flap shutterPKH-FAKS E R I E SPKH-3FAKWhen the unit is turned off, theshutter closes automatically overthe air outlet to enhance the stylishdesign. The shutter also functionsas a flap to adjust airflow angle toensure that comforting air reaches every corner of the room.PKH-4FAKEnhanced noise suppressionLow-noise operation has beenModelachieved through the introductionof a “near-silent” fan and aPKH-3design which minimises airflowPKH-4resistance.Sound pressure level (Lo/Hi)39/4541/46(dB)Multi-directional pipingTo reduce installation time, drain piping can be connected from leftand right. Refrigerant piping can also be connected from the rear, left,right and base of the unit.Easy removable filterConvenient thumbscrews on the filtersenable the filters to be quickly removed foreasier cleaning.Back plate installation guideTo save time and effort, the back plate installation guide provides clearinstructions on installation positions. The enlarged back plate securesthe unit firmly to the wall, while the support piece which lifts the unitmakes the left-side piping work much easier.INDEXSpecifications .p.11Option .p.13Drain lift-up mechanism (optional)For greater installation flexibility, the drain water pipe lift-up mechanism has been raised 800mm from the base of the unit.Features at-a-glanceInstallation & Maintenance Chargeless system Easy removable filter Drain water lift-up (800mm)* 4-way multi directional piping Self-diagnostic functionComfort Auto-angle airflow Computerized dehumidifier Quiet operationOthers System control Twin-multi operation Auto-flap shutter Outdoor unit operatingrange up to 46ºC*Optional8

CEILING SUSPENDEDExtra slim, extra stylishPCH-GAKS E R I E SPCH-3GAKPCH-4GAKPCH-5GAKPCH-6GAKSleek and slim with stylishly curved lines, the PCH-GAK Series blendsright into any interior. It also features a single air outlet with an autovane that closes like a shutter when the unit is turned off to enhanceoverall appearance.Innovative auto vane systemThe auto vane system swings up and downautomatically to distribute air more evenlythroughout the room.Auto vaneSwingQuiet and comfortableSmoother airflow, an improved air vent design, and a slimmer fancombine to provide exceptionally quiet operation — a mere 43dB onhigh and 37dB on low (PCH-3GAK).New direct suspension systemFor easier installation, the PCH-GAK Series features a new direct suspension system that makes it unnecessary to remove nuts and boltsfrom the main body. A one-touch suspension system is also available.Direct suspension with attachment fixture attached1. Leave attachment fixture attached to main unit.2. Suspend the attachment fixture from the suspension bolts.3. Simply tighten the nuts to secure the unit.Ceiling surfaceSuspension boltsAttachment fixtureAir outletINDEXSpecifications .p.12Option .p.13Piping flexibility simplifies installationAll piping, including those related to drainage, can be connected fromthe right, rear and top of the unit. This provides greater flexibility inselecting piping layout and installation locations.Flockless vanesWith the adoption of new flockless vanes, dirt and other impurities canbe cleaned off easily with mild household detergent.Fan phase control plus microprocessor control allowairflow settings to match ceiling height.Drain water lift-up mechanism can be pre-installed(optional).Features at-a-glanceInstallation & Maintenance Chargeless system New direct suspensionsystem Drain water lift-up (500mm)* Flexible piping Long-life filter (2500 hrs.) Washable filter* Self-diagnostic functionComfort Auto swing High ceiling application Computerized dehumidifier Quiet operationOthers System control Twin-multi operation Auto restart Auto vane shutter Outdoor unit operatingrange up to 46ºC*Optional9

CEILING CONCEALEDLimitless installation possibilitiesPEH-EAKS E R I E SPEH-2.5EAKPEH-4EAKOffering all the benefits of split-type models plus other importantadvantages, the PEH-EAK Series is not only easy to install but also veryversatile. For example, the distance between the air-intake and air-outlet vents can be varied to allow airflow to be positioned in the optimum location.PEH-3EAKPEH-5EAKPEH-6EAKLong-rectangular roomL-shaped roomPEH-2.5EAKPEH-3EAKPEH-4EAKRoom withfixed ceilingfixturesPEH-5EAKPEH-6EAKComputerized dehumidificationThe computerized dehumidifier mode — where fan speed is controlledprecisely — increases dehumidification volume while improving dehumidifying efficiency.INDEXSpecifications .p.12Option .p.13Features at-a-glanceInstallation & Maintenance Chargeless system Smooth instllation Self-diagnostic functionComfort Computerized dehumidifier Quiet operationOthers System control Twin-multi operation Auto restart Outdoor unit operatingrange up to 46ºC10

S P EC I F I C AT I O N SPLH-AAKModelsFunctionCapacityTotal inputCOPPOWER CEILING CASSETTEPLH-3AAKWkWW/WModel nameIndoor unitExternal finishPower supplyAirflow ( Lo-Hi)External static pressureSound pressure level ( ,4003.112.70Cooling9,7003.462.80PLH-3AAKl/sPa ( mmAq)dBW mmD mmH mmkgDimensionsWeightModel name250 – 33328 – 3425824W mmD mmH mmkgPUH-3YKAWeightPKH-FAKkW2.4l/sWdBdBW mmD mmH mmkgWkWW/WDimensionsWeightOutdoor 66754695570870295 24850755671970345 3.24PKH-4FAKMunsell 3.4Y 7.7/0.8Single phase, 50Hz, 240Vl/sPa (mmAq)dBW mmD mmH mmkg250 – 333367 – 4670 (direct blow)39 – 451,40041 – 461,6802353402428PUH-3YKAPUH-4YKSAMunsell 5Y 7/13-ph., 50Hz, 415V (4 wires)Capillary tubekWProtection devicesAirflowCrankcase heaterSound pressure levelSound power level32Thermal relay, thermal switch, HP switch, anti-phase protectorPKH-3FAKModel nameExternal finishPower supplyRefrigerant (R-22) controlCompressor output37 – 453.5PKH-3FAKExternal finishPower supplyAirflow (Lo-Hi)External static pressureSound pressure level (Lo-Hi)367 – 500WALL MOUNTEDModel nameIndoor unit2.7Internal thermostat, HP switch /thermal relay, thermal switch,anti- phase protectorModelsFunctionCapacityTotal inputCOPPLH-6AAK3-phase 50Hz, 415V (4 wires)Capillary tubeProtection devicesDimensionsPLH-5AAKMunsell 5Y 7/1Outdoor unitAirflowCrankcase heaterSound pressure levelSound power 63.27Heating14,0004.463.14Galvanized sheets with gray heat insulationSingle phase, 50Hz, 240V333 – 4670 (direct blow)33 – 4135 – 438408402983030Munsell 0.70Y 8.59/0.97950950305PUH-4YKSAPUH-5YKSAExternal finishPower supplyRefrigerant (R-22) controlCompressor l finishIndoor grillePLH-4AAKHeating10,4003.453.01l/sWdBdBW mmD mmH mmkg2.4Internal thermostat, HP switch/t hermal relay, thermal switch, HP switch,anti- phase protector8332.7Thermal relay, thermal switch, HP switch, anti-phase protector1,5843852665469870295 24850751,25894

S P EC I F I C AT I O N SPCH-GAKCEILING SUSPENDEDModelsPCH-3GAKFunctionCapacityTotal inputCOPIndoor unitModel nameExternal finishPower supplyAirflow (Lo-Hi)External static pressureSound pressure level utdoor unit Protection devicesAirflowCrankcase heaterSound pressure levelSound power Munsell 0.70Y 8.59/0.97Single phase, 50Hz, 240Vl/sPa (mmAq)dBW mmD mmH mmkg233 – 300333 – 417450 – 5670 (direct blow)37 – 4340 – 4541 – 4642 – 481,3101,620680Model nameExternal finishPower supplyRefrigerant (R-22) controlCompressor KAPUH-4YKSAPUH-5YKSAPUH-6YKSAMunsell 5Y 7/13-ph., 50Hz, 415V (4 wires)Capillary tubekW2.42.73.5Internal thermostat, HP switch/thermalthermal relay, thermal switch,relay, thermal switch, HP switch,HP switch, anti-phase protectoranti-phase protectorl/s8331,584W38dB5254dB6669W mm870D mm295 24H mm85094kg754.0Internal thermostat, thermal switch, HP switch, anti- phase protector1,66755705671970345 241,258114117PEH-EAK CEILING CONCEALEDModelsFunctionCapacityTotal inputCOPWkWW/WModel nameExternal finishPower supplyIndoor unitAirflow (Lo-Hi)External static pressureSound pressure level (Lo-Hi)DimensionsWeightl/sPa (mmAq)dBW mmD mmH 7PEH-2.5EAKPEH-3EAKPEH-4EAKGalvanized sheetsSingle phase, 50Hz, 240VPEH-5EAKPEH-6EAK450 – 567127 (12.7) at Hi-notch567 – 700800 – 1,000367 – 45052 – 5578554 – 584546Model nameExternal finishPUH-2.5AKAPUH-3VKA / PUH-3YKAPower supplySingle ph., 50Hz, 240VSingle ph., 50Hz, 240V/3-ph., 50Hz, 415V (4 wires)Refrigerant (R-22) controlCompressor outputkW2.0Internal thermostat,HP switchProtection devicesOutdoor unitAirflowCrankcase heaterSound pressure levelSound power levelDimensionsWeightl/sWdBdBW mmD mmH mmkg2.2 / 2.4Intermal thermostat, HPswitch/t hermal relay, thermalswitch, HP switch, antiphase protector8331,2557273PUH-4YKSAMunsell 5Y 7/1PUH-5YKSAPUH-6YKSA3-ph., 50Hz, 415V (4 wires)Capillary tube2.73.5Thermal relay, thermalswitch, HP switch, antiphase protectorInternal thermostat,thermal switch,HP switch, anti-phase protector1,6675570870295 24755671970345 24850684.01,584385469526651 – 551,4151,05569042858941,25811411712

GEN ER AL SP ECI F IC ACION S FOR ALL MODELS Notes for All Specifications Rating conditions: Cooling - Indoor 27ºCDB, 19ºCWB; Outdoor 35ºCDB; Outdoor 7ºCDB,6ºCWBHeating - Indoor 20ºCDB Data based on indicated voltage Indoor unit : 1-ph, 240V, 50HzOutdoor unit : 1-ph, 240V, 50Hz/3-ph, 415V, 50Hz Refrigerant piping length (one-way): 5m (16ft) Refrigerant charge is suitable for 5m piping length. Guaranteed Operating RangeLimitsCoolingHeatingIndoors21ºC DB, 15.5ºC WB35ºC DB, 22.5ºC WB20ºC DB27ºC DBLowerUpperLowerUpperOutdoors-5ºC DB46ºC DB-8.5ºC DB, -9.5ºC WB21ºC DB, 15.5ºC WB Refrigerant PipingModelsMax. height difference, mBetween indoor & outdoor unitsMax. piping length, mMax. number of bends505015Ø 9.52Ø 15.88505015Ø 9.52Ø 19.05PLH-3AAK, PKH-3FAK,PCH-3GAK, PEH-2.5EAK, PEH-3EAKPKH-4FAK PLH-4/5/6AAK,PCH-4/5/6GAK, PEH-4/5/6EAKPipe size O.D., mmLiquidGas Optional Refrigerant PipesPipe length5m (16ft)7m (23ft)10m (33ft)15m (49ft)Connection methodPipe size OD, mm (ft)Applicable modelsPart ared-flaredFlared-flaredLiquid: Ø 9.52 (3/8) Gas: Ø 15.88 (5/8)Liquid: Ø 9.52 (3/8) Gas: Ø 19.05 (3/4)PKH-3FAK, PLH-3AAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAKPKH-4FAK, PLH-4/5/6AAK, PCH-4/5/6GAK, PEH-4/5/6EAK Additional Refrigerant Charge [R-22: YKSAPUH-6YKSA5m0000010m0000015m0000020m00000Piping length .930/0.995450.920/0.993500.910/0.990 Cooling Capacity Correction FactorsModelsOne-way piping length, mPEH-2.5EAKPKH-3FAK, PCH-3GAK,PLH-3AAK, PEH-3EAKPKH-4FAK PCH-4GAK,PLH-4AAK, PEH-4EAKPCH-5GAK PLH-5AAK,PEH-5EAKPCH-6GAK, PLH-6AAKPEH-6EAKCorrection factors (Cooling / 990 Main Optional C-SG03TM-EPAC-SG01KFPAC-SG06SP-EPAC-SE85DM A-EPAC-SE86DM 3DescriptionMA & Control Terminal InterfaceTimer AdapterMultiple Remote Controller Adapter (10 sets)Remote SensorDrain SocketDrain SocketAir Outlet GuideDistribution Pipe for Twin UseMulti-Function CasementHigh Efficiency Filter ElementAir Outlet Shutter PlateDrain Lift-Up MechanismDrain Lift-Up MechanismHigh Efficiency FilterHigh Efficiency FilterWireless Remote ControllerWireless Remote ControllerApplicable modelsNew A/K controlNew A/K controlNew A/K controlNew A/K controlPUH-2.5 4PUH-5/6PUH-2.5 6PUH-5/6PLH seriesPLH seriesPLH seriesPCH-3PCH-4 6PCH-3/4PCH-5/6PCH seriesPLH series

Outdoor Unit Installation Location When installing a single outdoor unit:Obstacle at rear onlyObstacle at the front andrear onlyService spaceABCDEFGHITop obstaclesPUH-2.5, 3100mm or more10mm or more500mm or more500mm or moreService space100mm or more500mm or more10mm or more200mm or moreObstacles at the right, leftand rearPUH-4,5,6150mm or more10mm or more500mm or more500mm or more150mm or more500mm or more10mm or more300mm or moreJKLMNOPQObstacles at the front andrear onlyPUH-2.5, 3PUH-4,5,610mm or more10mm or moreObstruction width: 1.5 times the width ofoutdoor unit or smallerObstruction height: Unit height or lowerAir outlet guide500mm or more500mm or more100mm or more150mm or more3000mm or more3800mm or more100mm or more150mm or more When installing many outdoor units:Face-to-face arrangement(with air outlet guides)Face-to-face arrangement(without air outlet guides)Side-by-side arrangementParallel arrangement(with air outlet guides)Parallel arrangement(without air outlet guides)ABCDEFGHIJKPUH-2.5, 3PUH-4,5,6200mm or more300mm or more500mm or more500mm or more200mm or more300mm or more1200mm or more1500mm or more1000mm or more1500mm or more2000mm or more2500mm or more100mm or more150mm or more10mm or more10mm or more200mm or more300mm or moreUp to 10 units (When the optional air outletguides are used, no more than five units shouldbe arranged side by side.)1000mm or more1000mm or morePrecautions/recommendations concerning the installation and operation of Mitsubishi Electric Mr. Slim air conditioners. When used in rooms with high ceilings, it is recommended that a ceiling fan orcirculator be installed to improve air circulation and temperature variations withinthe room. The remote-control circuits under microprocessor control remain on at alltimes whether the air conditioner is or is not in operation. For more economicaloperation, it is recommended that the main power switch be turned off when theair conditioner(s) is not used for long periods. Avoid using air conditioning units in areas where they are exposed to oil or oilysmoke (cooking areas or machine shops). Oil which adheres to the heatexchangers will cause reduced efficiency, generate mist and may damage plasticcomponents. Avoid exposure to high-frequency waves as this may cause the microprocessorto malfunction. Rated noise levels were derived from tests in an anechoic test room. Noiselevels may therefore be greater depending on the surroundings, application,and/or manner of installation. Avoid using air conditioners in rooms with high humidity because excessivecondensation will occur as the air cools. To avoid fire hazards, do not use air conditioners in areas where inflammablegases are present. Odours for buildings, cosmetics, perspiration, cigarette smoke, etc., mayaccumulate in the heat exchanger and emanate from the air conditioner. This isnot indicative of mechanical trouble.14

ISO 9001NATIONALACCREDITATIONOF CERTIFICATIONBOOISCertificate Number 49385Mitsubishi Electric Shizuoka Works acquired ISO9001 certification under Series 9000 of theInternational Standard Organization (ISO) based ona review of Quality warranties for the production ofrefrigeration and air conditioning equipment.Mitsubishi Electric Shizuoka Works acquired environmental management system standard ISO14001 certification.Certificate Number EC97J1132HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANMITSUBISHI ELECTRIC AUSTRALIA PTY LTD.BLACK DIAMOND TECHNOLOGIESwww.mitsubishielectric.com.au (Incorporated in New South Wales)ABN 58 001 215 792New South Wales:348 Victoria Road,Rydalmere 2116Ph: (02) 9684 7555Fax: (02) 9898 1043Victoria/Tasmania:Unit 4,303 Burwood Highway,East Burwood 3151Ph: (03) 9262 9855Fax: (03) 9262 9844QueenslandUnit 12,469 Nudgee Rd.,Hendra 4011Ph: (07) 3623 2000Fax: (07) 3630 1888L-179-0-C3085-F SI-0608 Printed in Japan(NLP)Far NorthQueensland:Capricorn Air,13 Mackley st,Garbutt 4814Ph: (07) 4775 5222Fax: (07) 4775 5305South Australia/Northern Territory:77 Port Road,Hindmarsh 5007Ph: (08) 8340 2000Fax: (08) 8340 0555Western Australia:Unit 5,329 Collier Road,Bassendean 6054Ph: (08) 9377 3400Fax: (08) 9377 3499www.bdt.co.nzWellington:1 Parliament StreetPo Box 30-772Lower HuttWellingtonPh: (04) 560 9147Fax: (04) 560 9133Auckland:Unit 1,4 Walls RoadPo Box 12-726,PenrosePh: (09) 526 9347Fax: (09) 526 9369Christchurch:Suite 2, Level 1,37 Mandeville StreetPo Box 1604Ph: (03) 341 2837Fax: (03) 341 2838Revised publication, effective August 2006Superseding publication of L-179-0-C3085-E November 2005Specifications subject to change without notice.

Whichever model from our Mr. SLIM line-up you may choose for commer-cial use in restaurants, stores, or offices will be your guarantee of exceptional comfort in every and all operating condition. Comfort Optimum Cost Performance and Energy Savings MEQ results in air conditioners that are rat

Related Documents:

Mitsubishi RCN-K-E Mitsubishi RCN-KIT3-E Mitsubishi RCN-T-36W-E Mitsubishi RCN-TC-24W-ER Mitsubishi RKN502A-241D Mitsubishi RKN502A241F Mitsubishi RKS502A503 Mitsubishi RKW502A001 Mitsubishi RKW502A200 Mitsubishi RKW502A200A/B Mitsubishi RKX502A001B Mitsubishi RKX502A001C Mitsubishi RKX502A001G Mitsubishi RKX502A001P Mitsubishi RMA502A001 .

mitsubishi catalogue date: 2017/08/11 seq. photo oem_no description 9 1005a207 mitsubishi 4d56 cyl head gasket 10 1025a091 mitsubishi 4d56 l200 2.5 crdi 16 valv rocker arm with screw 11 md723202 mitsubishi 4d68t/mitsubishi l200 gl gls e . w repair kit for b/master cylinder 120 mr305377 mitsubishi pajero l200/l300 (4g54) speed

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

Mitsubishi ASX 2011 Mitsubishi L200 2015 2017 Mitsubishi L200 2018 Mitsubishi Lancer 2007 2016 Mitsubishi Outlander [mk3] 2012 Mitsubishi Pajero Sport 2015 Nissan 370Z [Z3

CBM01 30 184 Mitsubishi Mitsubishi 3000GT, Stealth AWD- Galant, Eclipse, Expo, Expo LRV AWD- Eagle Summit Wagon, Laser, Talon CBM02 30 158 Mitsubishi Mitsubishi Eclipse AWD (95-99) CBMOP 30 13 194 Mitsubishi Outlander 2001 - 2006 Front CBMOT 30 13 219 Mitsubishi Outlander 2001 - 2006 Rear CBMCO 30 16 162

the user to the presence of important operating and maintenance (serv-icing) instructions in the literature accompanying the product. WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. . Mitsubishi(8x,16x) Mitsubishi(4x) Mitsubishi(3x) Mitsubishi(8, 16x)Mitsubishi(2.4x, 8x) Mitsubishi(4x) .

Mitsubishi Dealer is the best way to protect your new car. By having your vehicle maintained by a Mitsubishi Dealer, it is understood that your vehicle is being serviced by Mitsubishi experts and will be fitted with Mitsubishi Genuine Parts. Doing this maintains your Mitsubishi vehicle and your warranty in the best condition.

10 tips och tricks för att lyckas med ert sap-projekt 20 SAPSANYTT 2/2015 De flesta projektledare känner säkert till Cobb’s paradox. Martin Cobb verkade som CIO för sekretariatet för Treasury Board of Canada 1995 då han ställde frågan