Price ListContentsMoulded Case Circuit Breakers:Compact NSXm: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MCCB with Integrated Earth Leakage Protection. . . . . . . . . . . . . . . . 11 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12MCCB for Motor Protection: GV4LE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 GV4PE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Accessories for GV4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Auxiliary Contact Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Compact NSX: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Circuit Breakers for Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . 24 MCCB with Integrated Earth Leakage Protection. . . . . . . . . . . . . . . . 26 MCCBs for DC Network Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Automatic Source Changeover System. . . . . . . . . . . . . . . . . . . . . . . 31Compact NS: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 MCCBs 800A onwards Manual Fixed. . . . . . . . . . . . . . . . . . . . . . . . . 34 MCCBs 800A onwards Electrical Fixed. . . . . . . . . . . . . . . . . . . . . . . 36 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37EasyPact CVS: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Easy-Pact CVS Switch Disconnector Version. . . . . . . . . . . . . . . . . . . 45 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46EasyPact EZC: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 MCCBs for Distribution Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51EasyPact NKS MCCBs for AC Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . 52 Simpact NKS DC MCCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Ground Fault / Earth Leakage Protection: Unique Modular Ground Fault Protection . . . . . . . . . . . . . . . . . . . . . 54 Earth Leakage Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Vigirex - Earth Leakage Protection Relay . . . . . . . . . . . . . . . . . . . . . 56 Compact- INS & INV Switch Disconnectors. . . . . . . . . . . . . . . . . . . . 57 Switch Disonnector fuse units - range overview. . . . . . . . . . . . . . . . . 58 Fupact Switch Disconnector and Accessories. . . . . . . . . . . . . . . . . . 59Air Circuit Breakers:MasterPact MTZ: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Overview of MicroLogic X Trip Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 64Masterpact NT/NW: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Micrologic Trip system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 ATS Kit range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68www.techmech.yolasite.com

Price ListContentsEasyPact MVS: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 ET/ETA/ETV Trip System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Draw-out type Circuit breakers and Switch Disconnectors . . . . . . . . 72 Fixed type Circuit breakers and Switch Disconnectors. . . . . . . . . . . 74 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76EasyPact SPS: Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Draw-out type Circuit breakers and Switch disconnector . . . . . . . . . 78 Fixed type Circuit breaker and Switch disconnector . . . . . . . . . . . . . 79 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79www.techmech.yolasite.com

Green PremiumTMEndorsing eco-friendly products in the industrySchneider Electric’s Green Premium ecolabel iscommitted to offering transparency, by disclosingextensive and reliable information related tothe environmental impact of its products:Green Premium is theonly label that allows youto effectively develop andpromote an environmentalpolicy whilst preservingyour business efficiency.This ecolabel guaranteescompliance with up-to-dateenvironmental regulations,but it does more than this.Over 75% ofSchneider Electricmanufactured productshave been awarded theGreen Premium ecolabelRoHSSchneider Electric products are subject to RoHS requirements ata worldwide level, even for the many products that are not requiredto comply with the terms of the regulation. Compliance certificates areavailable for products that fulfil the criteria of this European initiative,which aims to eliminate hazardous substances.REAChSchneider Electric applies the strict REACh regulation on its productsat a worldwide level, and discloses extensive information concerningthe presence of SVHC (Substances of Very High Concern) in all ofthese products.PEP: Product Environmental ProfileSchneider Electric publishes complete set of environmental data,including carbon footprint and energy consumption datafor each of the lifecycle phases on all of its products, in compliancewith the ISO 14025 PEP ecopassport program. PEP is especially usefulfor monitoring, controlling, saving energy, and/or reducingcarbon emissions.EoLI: End of Life InstructionsAvailable at the click of a button, these instructions provide: R ecyclability rates for Schneider Electric products.Discover what wemean by green G uidance to mitigate personnel hazards during the dismantling ofproducts and before recycling operations. P arts identification for recycling or for selective treatment, to mitigateenvironmental hazards/ incompatibility with standard recycling processes.Check your products!se.com/inwww.techmech.yolasite.com5

Product Selector-Select Schneider products through digital toolProduct selector is an online software tool embedded in Schneider website or in distributor s website to help selecting the rightproduct with its accessories. Product Selector aims at providing a fast, secure and smart way of selecting products. It includesthe selection of the basic frame, control unit, accessories and Digital Modules. Compared with the traditional way of filling uporder forms or specifying customer functions, it brings the following benefits:Easy access: no login, direct access on Schneider's website or on the website of distributorReliable: The compatibility between the main product and the accessories is constantly testedWide coverage: more than 130 Schneider ranges are available (MasterPact, ComPact, TeSys, Acti 9, Altivar.)Choose Products in simple steps:1. Go to range page on se.com2. Click on Launch Product Selectorse.com/inwww.techmech.yolasite.com6

Introducing Future of Power DistributionNEWMasterpact MTZ Circuit BreakerFUTURE READYStay connected and avoid downtime - The Masterpact MTZapp and EcoStruxure software conveniently bring energydata, circuit breaker control, and more directly to yoursmartphone.Contribute to a better world - with Green Premium MasterpactMTZ circuit breakers you can enhance sustabinability.Access new energy-saving capabilities - Acertified Class1 power meter gives you precise power measurements forgreater efficiency.Keep your electrical system online even in harshenvironments - Masterpact MTZ circuit breakers give youproven reliability by going beyond standards.Customize Micrologic X control unit anytime - Digitalmodules make it easy to upgrade and tailor your system.Simplify your switchboard operation - Masterpact MTZ circuitbreakers are adaptable to different systems because of theirdigital capabilities.Learn more about the future of powerdistribution, Click or ScanStreamline configuration and commissioning withEcoStruxure Power Commission tool.se.com/inwww.techmech.yolasite.com7

Introducing ComPact NSX & NSXm with Integrated EarthLeakage ProtectionNEWThe ComPact NSX range is now complementedwith a new type of MicroLogic trip unit includingcircuit protection, (overload,short circuit,neutralprotection) and earth leakage protectionNEWThe ComPactNSXm range is now available witha new type of MicroLogic trip which offersoverload, short circuit protection along withearth leakage protectionIntegrated earth leakage protection Easy to integrate into a row that does not have earth leakage protection Simple to use, reliable, and now comes in the same frame size, and for the same panel support Gain up to 40% in space when using with integrated earth leakage protection into the MicroogicVigi trip units Now there’s no need to order separate earth leakage modules. Save time, now that there’s one less item to add to thepanel board. Part of the EcoStruxure Power architecture, with digital communication capability and data management (settings,measurement, pre-alarms, trip & test history)se.com/inwww.techmech.yolasite.com8

Compact NSXm circuit breakers:Optimized for your needsThe Compact NSXm range of circuit breakers and switch disconnectorsis a newcomer in the Compact NSX family. It is one of the smallest on themarket with innovative features. Built on the design of roto-activebreaking technology, we have made it as robust as Compact NSXproducts.Compact NSXm main features and innovations Rated Current ,In (A) – 16, 25, 32, 40, 50, 63, 80, 100, 125, 160 Breaking capacity (kA) at 415V – 16, 25, 36, 50, 70 Thermal magnetic trip unit integrated Built-in DIN rail and plate mount Auxiliaries externally visible EverLink connectorsEverLink patented technologyThe Compact NSXm features a new cable connection method with patentedcreep-compensating technology built directly into the terminal - EverLink : With EverLink connectors, save space and time during panel assembly.More than 35patents havebeen registeredfor this newCompact NSXmoffer. Bare cable connections are as safe as compression lug ones.InstallationSpace for spring effectUntightenedTighteningIn contactTightenedOver timeCreep-compensatingeffectSpring maintainscontact pressure:Creep compensationTo experience,Click or Scanse.com/inwww.techmech.yolasite.com9

Compact NSXmMoulded Case Circuit BreakersWith Thermal Magnetic Trip Unit(TMD) and Compression Lug connectors LUG CONNECTIONBreaking Capacity Icuas per IEC 60947-216kA25kA36kA50kA70kARated A50A63A80A100A125A160AIcs 100% Icu as per IEC 60947-2Adjustable thermal setting 0.7 – 1 x InFixed magnetic settingsSingle frame size upto 160A5 breaking capacities from 16kA to 70kAWith compression lug connectorsAll the circuit breakers have a transparent lead-sealable coverThree Pole 8LV426559Unit LP [ ] Four Pole 565LV426566LV426567LV426568LV426569Unit LP [ 0Note: For Everlink type NSXm MCCBs add prices of LV426970 (3Pole) or LV426971(4Pole) -2 Sets in above MCCBsForFor detailsdetails onon stockablenon-standardand references,non stockabletechnicalstatus,parameters,technical parameter,stockablepleaseand non-stockablecontact Customerstatus,CarepleaseCentrecontact Customer Care Centre. NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com10

Compact NSXmMCCB with IntegratedEarth Leakage ProtectionNEWWith integrated earth leakage protection(MicroLogic Vigi 4.1 Trip Unit) Standard protection of distribution cables Earth leakage protection Indication of: Overload alarming (via LEDs and via SDx module) Overload tripping (via the SDx module) Earth leakage alarming (via the SDx module) Earth leakage tripping (via front face screen and theSDx module).Breaking Capacity Icuas per IEC 60947-216kA25kA36kA50kA70kARated CurrentThree Pole V426783LV426790LV426791LV426792LV426793Unit LP [ ] Four Pole 796LV426797LV426798Unit LP [ 0details ontechnicalstockablepleaseand non-stockablestatus,Carepleasecontact Customer Care Centre.For Detailson non-standardstockable ical parameter,Contact CustomerCentre NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com11

Compact NSXmSwitch Disconnector Suitability for isolation as defined by standard IEC 60947-3 Self protected by their high-set magnetic release Single frame size upto 160ACompact NSXm NA switch-disconnectorWith Compression Lug connectorsThree PoleReferenceRated Current50A100A160AFour PoleReferenceUnit LP [ ]LV426650LV426651LV4266528570857017540Unit LP [ ]LV426660LV426661LV426662126801268023390Compact NSXm NA switch-disconnectorWith EverLink connectorsThree PoleReferenceRated Current50A100A160AFour PoleReferenceUnit LP [ ]LV426600LV426601LV4266029060906018550Unit LP [ s for Compact NSXm16A to 07065302210Ue(V)OFFRes40 CCat.AIEC/EN60947-250/60HzUi etactComp559LV426GB14048.2HICHIC1006525Trip40 CCat.A-2IEC/EN6094750/60HzUi 8kV4P frameCom6559LV42Ø 4.OnTrip.8MNØ 4.8Off4P frame250V / ResetResetpactCom6559LV4240 CCat.AUi 8kV50/60Hz 53022108.2AB1NEMAGB1404240480100706530226OnØ 4.8HICTrip47-2IEC/EN6091006525Ø 4.8Trip600Y/347OffØ 4.8ResetTerminal spreadersOF or SD auxiliarycontact standardMN or MX voltagereleases standardDirect rotary handleSide Rotary handleExtended rotary handleNSXm AccessoriesAuxiliary contacts (changeover)DescriptionReferenceStandard OF or SDLV426950Voltage ReleasesUnit LP [ ]820DescriptionShunt ReleaseReferenceUnit LP [ ]Under VoltageReferenceUnit LP [ ]ACRotary HandlesDescriptionDirect rotary handleReferenceStandard black handleLV4269301100LV4269321650LV4269352800Unit LP [ ]Extended rotary handleStandard extended rotaryblack 426801LV426802LV426803LV4268152650DC24 V48 V125 V250 VSide rotary handleStandard side rotary blackhandle24 V 50/60 Hz48 V 50/60 Hz110-130 V 50/60 Hz220-240 V 50/60 Hz380-415 V 50 HzLV426841LV426842LV426843LV426844Rotary HandlesDescriptionReferenceSpreaders & Phase BarriersSpreaders (Set of 3) 3PSpreaders (Set of 4) 4PLV426940LV426941Unit LP [ ]600600Everlink AccessoriesDescriptionEverlink ConnectorsReferenceUnit LP [ ]EverLink connector with controlLV426970wire terminal for 3P (Set of 3)650EverLink connector with controlLV426971wire terminal for 4P(Set of 4)850ForFor detailsdetails onon stockablenon-standardand references,non stockabletechnicalstatus,parameters,technical parameter,stockablepleaseand non-stockablecontact Customerstatus,CarepleaseCentrecontact Customer Care Centre. NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com12

MCCB for Motor ProtectionGV4LE IEC/EN 60947-1, IEC/EN 60947-2, CCC, EACCan be used with class 5, 10 or 20 relayShort Circuit Protection with an adjustable pick-up Ii 6 to 14 In.From 0.25 - 55kWMagnetic Protection Toggle ControlMotor Power AC3(400/415V AC)InMagneticsettingrange25kA breakingcapacityReference50kA 6--GV4LE07N6-Unit LP [ ]ReferenceUnit LP [ ]100kA 4LE07S65.5.1112000Unit LP [ ]GV4LE02S6GV4LE50S615500GV4LE80S6GV4LE115S6Note: For Everlink termination please order after removing the 6 at the end Eg. GV4LE115NGV4PE IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60497-4-1, CCC,EAC, CSA Overload or thermal protection Short time delay protection Short circuit protection Fixed Ground fault protection Phase unbalance or phase loss Front indications through LED Variable Trip class : Trip Class 10/ Trip Class 20Thermal Magnetic Protection Toggle ControlMotor Power AC3(400/415V AC)InThermalsettingrange25kA breakingcapacityReference50kA 9.7--GV4PE07N6-Unit LP [ ]ReferenceUnit LP [ ]100kA nit LP [ 5S6Note: For Everlink version please order after removing the 6 at the end. Eg. GV4PE115NCrimp Lug/busbar connectionDescriptionSold in lots ofReferenceCrimped lug connector screws1GV4LUGTransparent terminal shield for crimped lug connector1LAD96590Interphase barriers6LV4269201LV426940Spreader 3-poleTo increase the pitchto 35 mindetails ontechnicalstockablepleaseand non-stockablestatus,Carepleasecontact Customer Care Centre.For Detailson non-standardstockable ical parameter,Contact CustomerCentre NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com13

Accessories for GV4MX Shunt Trip Trips the circuit breaker when the control voltage rises above 70% of ratedvoltage Shunt trip 110.130V AC is suitable. etc for ground fault protection whencombined with a Class I ground fault sensing elementMN Under Voltage ReleaseTrips the circuit breaker when the control voltage drops below 35% of its ratedvoltageDescriptionMaximum NumberMx Shunt TripMn Undervoltage Release1MountingVoltageInternal, Plug-In1References24 VAC 50/60 HZ, 24 VDCGV4AS02748 VAC 50/60 HZ, 48 VDCGV4AS057110-130 VAC 50/60 HZ, 125 VDCGV4AS1372280220-240 VAC 50 HZ, 208-240 VAC 60 HZ,GV4AS287277 VAC 60 HZInternal, Plug-In380-415 VAC 50 HZ, 440-480 VAC 60 HZGV4AS48724 VAC 50/60 HZ, 24 VDCGV4AU02748 VAC 50/60 HZ, 48 VDCGV4AU057110-130 VAC 50/60 HZ, 125VDCGV4AU137220-240 VAC 50 HZ, 208-240 VAC 60 HZGV4AU247277 VAC 60 HZGV4AU286380-415 VAC 50 HZGV4AU415440-480 VAC 60 HZGV4AU486Unit LP [ ]2980Auxiliary Contact BlocksAn auxiliary contact block provides one changeover contact with one commonpoint for OF and SD function, depending on where it is insertedOpen/Close OF Function: indicates position of the circuit breaker contactsTrip Alarm SD Function: indicates circuit breaker tripping due to: Electrical fault (overload, short circuit) Shunt trip/Undervoltage release “Push to Trip” FunctionResets when the circuit breaker is resetDescriptionAuxiliary Contact BlockMaximum NumberMounting2 (1 Each For Of Or Sd)Internal Plug-InType of ContactsNO NCReferenceGV4AE11Unit LP [ ]800Rotary HandlesDescriptionDirect Mounting Rotary HandleFront Extended Rotary Handle (Min Shaft Length214Mm/Max Shaft Length 627Mm)TypeDegree of ProtectionReferenceBlackIP40GV4ADN01Red Handle on Yellow BezelIP40GV4ADN02Unit LP [ ]1195BlackIP54GV4APN01Red Handle on Yellow BezelIP54GV4APN02Red Handle on Yellow eUnit LP [ ]Side Rotary Handle (Left or Right)1775Connection AccessoriesDescriptionSpreader 3-pole (To increase pitch to 35mm) (1 pce)LV426940600ForFor detailsdetails onon stockablenon-standardand references,non stockabletechnicalstatus,parameters,technical parameter,stockablepleaseand non-stockablecontact Customerstatus,CarepleaseCentrecontact Customer Care Centre. NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com14

Ethernet Ready Next Generation Circuit BreakersCompact NSXLV circuit breakers from 16A to 630AEnergymeasurementand controlse.com/inIncreasedenergyavailabilitySafety andprotectionwww.techmech.yolasite.com15

Compact NSXEthernet ready Next-generation circuit breakers Ethernet based monitoring, control, alarm notification for energy, asset and networkmanagement Built-in energy metering with combined accuracy class of 2% for precisemeasurement Intelligent / Enhanced discrimination for continuity of service Patented reflex tripping, independent of other protection functions, ensures ultra fasttripping in the event of very high short circuit Encapsulated roto-active double break contact system limits fault current for extendedsystem life Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure High performance Ics Icu 100kA @ 690V ACRange Details: 16A to 630A in two frames sizes Breaking capacity up to 200kA @ 415V TMD and Electronic based trip unit Available in Fixed, Plug-in and Draw out type versionsse.com/inwww.techmech.yolasite.com16

Type of Trip UnitsMicrologic Trip Units(ASIC-Application Specific Integrated Circuit)ProtectionCasesMeasurementA AmmeterE Energy MeterApplication1I2 LS0I5 LSI6 LSIG2 NSX100-2503 NSX400-630--- DistributionG GeneratorAB SubsciberM MotorZ 16Hz 2/3Micrologic 1.3 MI400 or 630 AMotorMicrologic 2.2 GLS0I100, 160 or 250 AGeneratorMicrologic 2.3LS0I400 or 630 ADistributionMicrologic 2.3 MLS0I400 or 630 AMotorMicrologic 5.2 ALSI100, 160 or 250 AAmmeterDistributionMicrologic 5.3 ELSI400 or 630 AEnergyDistributionMicrologic 6.3 E-MLSIG400 or 630 AEnergyMotorExampleThermal Magnetic Trip Unit IS0SG-se.com/inAvailable from 16A - 250AOverload Setting (Ir) 0.7 - 1 x InShort Circuit Setting (Im)Fixed upto 160AAdjustable 5 - 10 x Ir (for 200A - 250A)InstantaneousShort Time with Fixed Time DelayShort Time with Adjustable Time DelayGround Faultwww.techmech.yolasite.com17

Compact NSX PV for Photovoltaic applications Circuit Breakers and Switch Disconnectors A complete DC offer for Solar Applications from 80 to1500A. 80A to 500A MCCB with TMD type trip unit 80A to 1500A Switch disconnectorEnsuring safe and efficient operation of yourPhotovoltaic installation.With heat sink supplied as standard, MCCB rating is optimized,avoiding the need to oversize protection components and savingspace in the enclosure.Connection and insulation accessories supplied asstandard with Compact NSX PV MCCB are: Connection plate with heat sink Upstream and downstream terminal shieldsse.com/inwww.techmech.yolasite.com18

PowerPactMultistandard offer for OEM applicationsBe compliant around the worldRange - 16A to 600A in Two frames sizes Compliance to UL489, IEC60947, CCC & CSA standards. Breaking Capacity up to 100kA Voltage rating up to 600V Isolation with Positive Break Indication Fixed, Plug-in and Draw out type TMD and Microprocessor based trip unit Built-in energy metering (2% accuracy class) Smart Integration over Communication NetworkTrust US. to supply worldwide availabilty to apply tested and validated solutions to comply to international op19

Compact NSXMoulded Case Circuit Breakers forDistribution NetworkWith Thermal Magnetic Trip Unit (TMD) Ics 100% Icu as per IEC 60947-2Adjustable thermal setting 0.7 - 1 x InAdjustable magnetic setting 5 – 10 x Ir **Transparent cover for trip unit as standardBreaking Capacity enhancement upto 150kA with a higher capacityupstream (Cascading) Exceptional current limiting 6 x 105 A2SBreaking Capacity Icuas per IEC 60947-225kA36kA50kA70kARated CurrentThree Pole ReferenceUnit LP [ ] Four Pole ReferenceUnit LP [ ]16ALV4295579380LV4295671348025ALV429556 9380LV4295661348032ALV429555 9380LV4295651348040ALV429554 429552 9380LV429562 1348080ALV429551 9380LV42956113480100ALV429550 9380LV429560 13480125ALV430311 16520LV430321 20360160ALV430310 17690LV430320 22180200ALV43111125630LV431121 30830250ALV431110 26120LV431120 3144016ALV429637 11430LV4296471447025ALV429636 11430LV4296461447032ALV429635 11430LV429645 1447040ALV429634 LV429632 11430LV429642 1447080ALV429631 11430LV42964114470100ALV429630 11430LV429640 14470125ALV430631 17080LV430641 21270160ALV430630 17930LV430640 22940200ALV431631 25960LV431641 32000250ALV431630 26710LV431640 LV4298561705032ALV429845 13590LV4298551705040ALV429844 LV429842 13590LV4298521705080ALV429841 13590LV42985117050100ALV429840 13590LV42985017050125ALV430841 20540LV43085123620160ALV430840 20970LV43085024800200ALV431831 27980LV43184134180250ALV431830 LV4296832241063ALV429672 ALV429670 0ALV430670 0ALV431670 37520LV43168048760Note: ** applicable for NSX 200A & 250A For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre. NORMAL STOCK ITEMSW.E.F. January 27, 2020se.com/inwww.techmech.yolasite.com20

Compact NSXMoulded Case Circuit Breakers forDistribution NetworkWith Micrologic 2 (μP -ASIC based) Protection type LS0INIcs 100% Icu as per IEC 60947-2Adjustable overload from 0.40 - 1 x InAdjustable short circuit from 1.5 - 10 x IrInnovative front indication LED s (Ready, Overload pre-alarm & Overload)Two frame sizes up to 630ABreaking Capacity enhancement upto 150kA with a higher capacityupstream (Cascading) Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCBBreaking Capacity Icuas per IEC 60947-2Rated Current25kA36kA50kA70kAThree Pole ReferenceUnit LP [ ] Four Pole ReferenceUnit LP [ ]40ALV429777 16500LV42978721240100ALV429775 16500LV429785 21240160ALV430745 21080LV430750 26890250ALV431140 27710LV431150 3554040ALV42977216780LV42978221340100ALV429770 16780LV429780 21340160ALV430770 21460LV430780 29660250ALV431770 29010LV431780 40210400ALV432676 40220LV432677 45920630ALV432876 42520LV432877 5512040ALV42979720130LV42980727240100ALV429795 20130LV429805 28050160ALV430775 25510LV43078533190250ALV431870 33130LV431875 43070400ALV432693 42050LV432694 54610630ALV432893 43580LV432894 43179038290LV43180055250400ALV432695 47840LV43269662820630ALV432895 49030LV43289676260Note: For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.With Micrologic 2 (μP -ASIC based ) / TMD / MA shunt GFP Protection type LS0IGNIcs 100% Icu as per IEC 60947-2Fault indication for GF (LED type) meant for human safetyAdjustable overload from 0.36 - 1 x InAdjustable short circuit from 1.5 - 10 x IrAdjustable ea

1 power meter gives you precise power measurements for greater efficiency. Keep your electrical system online even in harsh environments - Masterpact MTZ circuit breakers give you proven reliability by going beyond standards. Stay connected and avoid downtime - The Masterpact MTZ app and EcoStruxure software conveniently bring energy

Related Documents:

NS (5kV) Medium Voltage Network Switch IS (5kV) Isolation Switch (Fused or Non-Fused) . (Low Voltage) Power Panel in Vault HDP 600V (High Voltage) Distribution Panel LDP 208V (Low Voltage) Distribution Panel HP 600V (High Voltage) Panelboard LP 208V (Low Voltage) Panelboard . 16.6. Acceptable products: Master Padlock catalogue numbers .

431.196 (a) Low Voltage Transformers (2) The efficiency of low voltage dry-type distribution transformers manufactured on or after January 1, 2016 shall be no less than that required for their kVA rating in the Table 1. Low-voltage, dry-type distribution transformers with kVA ratings not appearing in Table 1 have their

Low Voltage Products Our world class medium and heavy wall heat shrink as well as many specialized . products and kits for low voltage electrical applications Medium Voltage Products Detailed specifications on medium voltage terminations and joints. Equipment Insulation Insulation products for bus bars and industrial equipment .

North American Distribution Transformer Energy Efficiency (Philip J Hopkinson, PE) Definition of Distribution Transformer 1. Stand-alone Transformer not built in 2. Transformer voltage: a) Low (0-1,000 volts) to other Low Voltage b) Medium Voltage ( 1,000 volts to 35,000 volts) to Low voltage 3. Power Frequency 60 Hz in North America 4.

specifically designed for the low-voltage, structured cabling market. The floor bracket is industry-standard orange to identify low-voltage applications, the open design provides the space needed for low-voltage bend radius requirements, and the Leviton QuickPort Quad 106 insert provides up to four low-voltage outlet ports.

Amplifier Configurations . Voltage Amplifier: Voltage input and Voltage output The controlled source is a Voltage -controlled-Voltage Source A. v Open Circuit Voltage Gain can be found by applying a voltage source with R. s 0, and measuring the open circuit output voltage(no load or R. L infinity) Source Amplifier Load . Amplifier Input .

included in our catalogue Low Voltage Essentials - Contractor/Installer Products. ABB has a reputation for manufacturing and supplying quality low voltage components, the result of our on-going research and development programme. Our pro

3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Contact form Rated voltage Rated current (mA) Coil resistance ( ) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW) % of rated voltage DPDT (2c) 3 VDC 66.7 45 70% max. 10% min. 200% (at 23 C) Approx. 200 4.5 VDC 44.6 101 .