CertainTeedSHAFTLINERSHAFTLINERFor A rea Separation FirewallsSHAFTLINER

SHAFTLINERShaftliner Type X for Area SeparationGlasRoc Shaftliner is a speciallyformulated product forapplications where enhancedThe GlasRoc ShaftlinerType X advantage.moisture and mold resistanceGlasRoc Shaftliner and M2Tech Moistureweight, reduced thickness, ease andis preferred. It can be used forand Mold Resistant Gypsum Boards canspeed of installation, no requirement forbe combined to offer superior moldscaffolding, and no requirement for anresistance performance for Areaadditional trade on the job.firewalls in standard multi-familyresidential applications.GlasRocShaftliner Type X Separation Firewalls.Area Separation Firewalls offer theGypsum Area Separation Firewall systemsadvantages of fire resistance and noiseare ICC and NBCC Code Approved andattenuation between adjoining housing units.replace traditional masonry for fireThese walls offer a 2-hour fire resistanceseparation between multi-family units.rating line of defense between units andSome inherent advantages of gypsumprovide sound ratings up to STC 61.Area Separation Firewalls are: lighterGlasRoc Shaftliner is apaperless mold and moistureresistant gypsum boardcombining reinforcing glassmats and a speciallyformulated fire and moistureresistive, non combustible core.GlasRoc Shaftliner offers: Long term protection(12 months) to weatherDouble Beveled edgesexposure. A superior water resistantsurface that does not inhibitReinforcing glass matsGlasRoc Shaftliner is a 1” (25.4 mm)When tested for mold resistancethick gypsum board with a speciallyby an independent lab at the timeformulated, fire resistive, nonof manufacturing, GlasRoc Shaftlinercombustible core combined withachieved the best possible score ofreinforcing glass mats and double10 per ASTM D3273 and 0 perbeveled edges for ease of installation.ASTM G21.GlasRoc Shaftliner is designedGlasRoc Shaftliner may beand engineered for use in construc-substituted for 1” (25.4mm) M2Tech tion of lightweight Shaftwall and AreaShaftliner Type X with 1/2” (12.7 mm)Separation Firewalls. These systemsM2Tech Gypsum Boards in all Areaper ASTM D3273are UL Classified and ULC Listed forSeparation Firewall systems.and ASTM G21.fire resistance.water vapor permeance. Excellent fire resistanceproperties, and numerousfire rated designs. Resists mold growth2Specially formulated fire and moistureresistive, noncombustible core

FirewallsArea Separation FirewallsGlasRoc Shaftliner is used in conjunctionBreakaway aluminum clips are used towith CertainTeed gypsum board productsattach the interior wall to adjacent structuralin Area Separation Firewalls.metal framing and provide lateral support.Area Separation Firewalls are solid typeseparation walls assembled using 1”(25.4 mm) GlasRoc Shaftliner gypsumboard, metal framing and 1/2” (12.7 mm)M2Tech Moisture and Mold ResistantBoard or CertainTeed Regular orWhen one side is exposed to fire, the clipsyield from the heat and break away allowingthe gypsum board interior wall on the fireside to collapse. Thus the Area SeparationFirewall remains intact to protect neighboring spaces.Easi-Lite Gypsum Board for the interiorArea Separation Firewalls are easier andfinish. The firewall is easily stacked, floor tofaster to construct, lighter weight, and takefloor, allowing progressive construction.up less space than masonry wall systems.1/2” (12.7 mm)CertainTeed Regular or Easi-Lite or M2Tech Gypsum BoardNom. 2” x 4” (38 mm x 89 mm)wood studs or min. 3 1/2” (89 mm)25 or 20 gauge steel studsOptional CertainTeedFiber Glass Insulation1” (25.4 mm) GlasRoc Shaftliner Type X (2 layers)3/4” (19mm) Air SpaceH-stud 2” (51 mm)x 24” (610 mm) o.c.CertainTeed respects theenvironment through the responsibleBack to Back C-Trackdevelopment of sustainable buildingproducts and systems.2” (51 mm) x 2-1/4” (57 mm)Aluminum ClipsFire Blocking, As RequiredTMHealth ProductDECLARA TIONThickness: 1” (25.4 mm)Widths: 2’ (610 mm) StandardLengths: 8’ (2440 mm), 10’ (3050 mm) and 12’ (3660 mm) StandardEdges: Double beveledGlasRoc Shaftliner Type X for Area Separation Firewalls Call Toll Free 1-800-233-8990 www.certainteed.com3

Working With the ProductHandling and StorageGlasRoc gypsum boards should bestacked flat on a smooth, level surface,not stored directly on the ground.When spacers are used, position themclosely enough together to minimizewarpage. Care should be taken toprevent damage to edges and corners.Always keep gypsum board dry priorto installation. CertainTeed assumes no responsibility for consequentialdamages that may result from the presence of standingwater or where moisture is in direct contact with AreaSeparation Firewall system components.CuttingThe score and snap method is a fast andefficient way to cut gypsum board.Steps:1. O n the logo side, position a straightedge along the line of the intended cut.2. S core the glass mat sheet with a knifeor other suitable tool.3. W ith a quick, firm motion, snap backaway from the face.4. S core the back glass mat with a knifeor other suitable tool and then snap thepiece in the opposite direction.5. S mooth all cut ends and edges toensure tight joints.4To make cut outs, score around theperimeter on the logo side and back sideand tap out the waste piece from thelogo side. Cut outs can also be madewith a drywall saw. Gypsum boards canalso be cut with a saw. Safetyglasses should always be worn whenusing power tools. For information onavoiding dust inhalation, refer to theSafety Data Sheet available on our website, www.certainteed.com.InstallationArea Separation Firewall(Non-Loadbearing):Steel framing and installation of1’’ (25.4 mm) GlasRoc Shaftlinergypsum board for solid type AreaSeparation Firewalls are used as thecommon wall of one unit. An AreaSeparation Firewall can be constructedby following these steps beforecontinuing to frame the adjacent unit.1. A ttach 2’’ (51 mm) wide C-Track to slabat bottom of wall using suitable fasteners at a maximum of 24’’ (600 mm) o.c.Allow a 3/4’’ (19 mm) space from woodor steel stud framing on each side of thearea separation firewall.2. I nstall vertical C-Track at thebeginning of the wall and support asneeded.3. I nsert two sections of 1’’ (25.4 mm)GlasRoc Shaftliner, with the logoside facing weather exposure duringconstruction, in the bottom channel andplumb to vertical C-Track.4. Install 1’’ (25.4 mm) GlasRoc Shaftlinergypsum boards vertically. Continue wallas needed by placing H-Studs betweenthe proceeding panels every 24’’ (610mm) for the length of the wall andenclose the end boards with verticalC-Track.5. Cap the wall assembly before continuinghigher using C-Track fastened to theH-Studs on alternate sides with 3/8”(10 mm) Type S screws. A secondC-Track for the next row of shaftlinerpanels is then placed back to back withend joints staggered at least 12” (300mm) o.c. and fastened with double 3/8”(10 mm) Type S screws at ends and24” (600 mm) o.c.6. Attachment Clips: Aluminum angle,0.063’’ (1.6 mm) thick, min. 2’’(51 mm) wide with min. 2’’ (51 mm)and 2-1/4’’ (57 mm) legs. Clips

secured with Type S screws 3/8’’Accessible attic areas typically use(10 mm) long to H-Studs and withthis alternate method to preventType W screws 1-1/4’’ (32 mm) longhomeowners from placing itemsto wood framing or with Type Sin contact with or damaging thescrews 3/8” (9.5 mm) long to steelsteel components. Non-accessiblestuds through holes provided in theattic areas do not require the 6”clip. Clips spaced a max of 10’ (3050(150 mm) wide gypsum boarded areas, taking care not to roughmm) o.c. vertically between wood orbatten strips.the surrounding gypsum board paper.steel framing and H-Studs for12. Insulation (Optional) - CertainTeedseparation firewalls up to 23’CertaSound NoiseReducerTM, Fiber(7000 mm) high. For separationGlass Building Insulation, or equivalent,firewalls up to 44’ (13400 mm) high,installed between wood studs to meetclips spaced as described above forlisted STC performance.the upper 24’ (7300 mm) and the13. CertainTeed Regular gypsumcompound. Feather out each coat asdescribed in steps 4-6.8.Spot cover all fastener heads withthree coats of joint compound appliedin different directions.9.Lightly sand the last coat of all treat Smoothing can also be accomplishedwith a damp sponge.Finishing Interior WallsCertainTeed gypsum board can befinished with paint, texture or wallpaper.remaining wall area below requiresboard or M2Tech Moisture andHigh quality primer/sealer must be usedclips spaced a max. 5’ (1525 mm)Mold Resistant Gypsum Board, 1/2’’prior to any type of final decoration. Foro.c. vertically between wood framing(12.7 mm) thick, 4’ (1220 mm) wide,high gloss paint and severe lighting condi-and H-Studs.applied either horizontally or vertical-tions, a thin skim coat of joint compoundly. Gypsum board attached to studsor CertainTeed Level V Wall/Ceiling Primerthan 44’ (13400 mm) and up to 68’with 1-1/4’’ (32 mm) long steel dry-Surfacer should be applied across the(20700 mm) high, clips are spaced awall nails or 1-1/4’’ (32 mm) Type Wentire surface (Level 5 Finish). This will helpmaximum 40” (1015 mm) o.c. for thedrywall screws spaced 8’’ (200 mm)minimize the irregularities and porositylower 24’ (7300 mm) section, a maxi-o.c. Gypsum board attached to steeldifferences between the materials. Refermum 5’ (1525 mm) o.c. for the 24’ tostuds with min. 1” (25.4 mm) Typeto GA-214, GA-216, CAN/CSA-A82.31 and44’ section and a maximum 10’ (3050S drywall screws spaced 12” o.c.ASTM C840 for additional finishing instruc-mm) o.c. for the 44’ to 68’.(300 mm). Vertical joints located overtions. Finishing is not required on the Areastuds. Joints and fasteners finishedSeparation Firewall.7. For separation firewalls greater8. This assembly can be repeated, perwith CertainTeed Finishing system.plan, up to 68 feet (20700 mm) high.Cap the top of the assembly with 2’’(51 mm) C-Track and protect theentire installation from moisture.9. Where required, use an approvedacoustical sealant such as GreenGlue Noiseproofing Sealant to caulkaround the perimeter of wall sectionsand between horizontal back-to-backC-Tracks.Interior Finish Wall:Surface Preparation of Finished SidesJoints, corners and fastener heads on thelogo side shall be finished in accordance withASTM C840, GA-214, GA-216, CAN/CSAA82.31, GA Fire Resistance Design ManualGA-600 and joint compoundmanufacturer’s instructions. Joint compoundshall comply with ASTM C475.1. No surface treatment shall be doneuntil the interior temperature has(Protected Wall - Loadbearing orbeen maintained at a minimum ofNon-Loadbearing)50 F (10 C) for at least 48 hours prior10. Wood Studs - Nom 2’’ (38 mm) byto application of compounds and until4’’ (89 mm) max. spaced 24’’all materials have completely dried.(610 mm) o.c. Steel Studs - Min.Adequate continuous ventilation must3-1/2” (89 mm) 25 or 20 gaugealso be provided.steel studs max. spaced 24” (6102.joint compound.mm) o.c. Studs cross-braced atmid-height where necessary for clipFill and level joints with CertainTeed 3.Embed tape into the wet compoundattachment. Min. 3/4’’ (19 mm)and allow to dry. For inside corners,separation between wood framingcrease the tape and work it into joint.and Area Separation Firewall.4.approximately 4’’ (100 mm) on each(19 mm) airspace the steelside.components are permitted to becovered with 6” (150 mm) wide5.side.mm) CertainTeed gypsum board6.mm) o.c.Allow each coat to dry beforeproceeding.H-Studs with 1” (25.4 mm) TypeS drywall screws spaced 12” (300Apply a third coat and feather toapproximately 6’’ (150 mm) on eachbatten strips of min. 1/2” (12.7screwed to the C-Track andApply a second coat of compoundacross the joint and feather to11. As an alternate to the 3/4”7.Attach corner bead to outsidecorners and apply three coats of jointLimitations A rea Separation Firewalls are fornon-loadbearing partitions only. C ertainTeed gypsum board must not beused in areas that are continuously orrepeatedly exposed to excessivemoisture or dampness. S ystems shall not be exposed tosustained temperatures exceeding 125 F(52 C). G lasRoc and CertainTeed gypsumboards should not come in direct contactwith concrete, masonry or other surfacesthat have a high moisture content. U nsupported wall height between floorsshould not exceed 12’ (3660 mm). Theassembly may be used in buildings upto 4 stories with a total height not toexceed 68’ (20700 mm). Penetrations through the solid 2”(51 mm) Area Separation Firewallshould be protected by a FirestopSystem in accordance with IBC,Chapter 7 and NBCC Part 3.1.9. P enetrations in the solid 2” (51 mm)Area Separation Firewalls designed as aParty Wall (a wall located on a propertyline between adjacent buildings whichis used or adapted for joint servicebetween the two buildings), i.e. townhomes, are usually not permitted bycode authorities. Consult your localbuilding code authority.GlasRoc Shaftliner Type X for Area Separation Firewalls Call Toll Free 1-800-233-8990 www.certainteed.com5

Non-loadbearingFire Rating - 2 HourEXPOSED TO FIRE FROM AREA SEPARATION FIREWALL SIDE ONLY#25 MSG Galv 2”(51 mm) Steel Channel(Fastened 24” (600 mm) o.c. maximum)#25 MSG Galv Steel “H” Studs(Typically 24” (610 mm) o.c. maximum)FIRE TESTUL U366, ULC W3111”(25.4 mm) GlasRoc Shaftliner Type X (2 layers)SOUND TESTRAL-TL00-177STC 57THICKNESS6-3/4” (172 mm)NOM 2”x4” (38 x 89 mm) Wood Studsor Steel Studs 24”(610 mm) o.c.maximum3/4”(19 mm) Air Space.063”(1.6 mm) Aluminum AngleInsulationAttachment Clipsto Achieve STC1/2” (12.7 mm) M2Tech Moistureand Mold Resistant Gypsum Boardor CertainTeed Regular or Easi-Lite Gypsum Board Applied Horizontallyor Vertically APPROX. WT.10 psf (49 kg/m2)EXPOSED TO FIRE FROM EITHER SIDE#25 MSG Galv 2”(51 mm) Steel Channel#25 MSG Galv Steel “H” Studs1”(25.4 mm) GlasRoc Shaftliner Type X (2 layers)(Fastened 24” (600 mm) o.c. maximum) (Typically 24” (610 mm) o.c. maximum)1/2” (12.7 mm) M2Tech Moistureand Mold Resistant Gypsum Boardor CertainTeed Regular or Easi-Lite Gypsum Board Applied Horizontally orVerticallyFIRE TESTUL U366, ULC W311SOUND TESTRAL-TL00-176STC 61THICKNESS11 1/2” (292 mm)APPROX. WT.13 psf (63kg/m2)NOM 2x4”(38 x 89 mm) Wood Studs orSteel Studs 24”(610 mm) o.c. maximum3/4”(19 mm) Air Space.063”(1.6 mm) Aluminum AngleAttachment ClipsInsulationto Achieve STC 61TYPICAL INSTALLATION DETAILSRoof DeckC-TrackRoof Truss11 4”(32 mm)2”(51 mm)IntermediateStory2”x4” (38 x 89 mm) Woodor min. 3-1/2” (89 mm)Steel FramingOptionalCertainTeedInsulation1/2” (12.7 mm) M2Tech Moistureand Mold Resistant GypsumBoard or CertainTeed Regular orEasi-Lite Gypsum Board AppliedHorizontally or Vertically1”(25.4 mm)GlasRoc ShaftlinerType X (2 layers)Two C-TracksH-STUDIntermediateFloor2”(51 mm)First StoryAluminum ClipsCertainTeed Gypsum Board,insulation or other FireStopping/Draft Stoppingas required.2”(51 mm)21 4”(57 mm)ASW ALUMINUM CLIP3/4” (19 mm)Air Space1”(25 mm)First FloorC-TrackJoistC-Track Fasteners24”(600 mm) o.c.Vertical H-Studsnot shownFoundationor Bearing WallNot to scale62”(51 mm)C-TRACK

INTERMEDIATE FLOOR INTERSECTION LOCATION OF ASW CLIPS1” (25.4 mm) GlasRoc Shaftliner Type XDouble C-TrackScrewed Back-to-BackSealantFloorJoistFire Blockingas requiredCeiling3/8”(10 mm) Type S Pan Head Screws1-1/4”(32 mm) Type W Screw1/2”(12.7 mm) M2Tech Moisture and Mold Resistant Gypsum Board orCertainTeed Regular or Easi-Lite Gypsum BoardAluminum ClipCertainTeed Insulation3/4”(19 mm) Air SpaceEXTERIOR WALL INTERSECTION1/2” (12.7 mm) M2Tech Moisture and MoldResistant Gypsum Board or CertainTeed Regular or Easi-Lite Gypsum BoardPROTRUDING EXTERIOR WALL1/2”(12.7 mm)GlasRoc SheathingNominal 2”x4”(38 mm x 89 mm)Wood Studs or Steel Studs @24”(610 mm)o.c. max.1/2” (12.7 mm) M2Tech Moisture and MoldResistant Gypsum Board orCertainTeed Regular orEasi-Lite Gypsum Board1/2”(12.7 mm)GlasRoc SheathingExterior FinishExterior FacingH-StudFlashingH-Stud2” C-Track1”(25.4 mm) GlasRocShaftliner Type X CaulkingGlasRoc Shaftliner Type XCapCaulk3/4”(19 mm) Air Space2” C-Track3/4”(19 mm) Air SpaceExterior Wall FramingNominal 2”x4”(38 mm x 89mm)Wood Studs or Steel Studs @24”(610 mm) o.c. max.18”(450 mm) Min.(or as req’dby local codes)TYPICAL ROOF JUNCTION DETAIL1/2”(12.7 mm) or5/8”(15.9 mm)GlasRoc Sheathing orCertainTeed TypeX boardFire Blocking,as requiredCaulk2” C-TrackRoofingFire Blocking,as requiredTYPICAL ROOF PARAPET DETAILRoof DeckFire Blocking,as required2” C-TrackParapet CapFlashingRoofingAs Required(or As Req’d byLocal Codes)18”(450 mm)Aluminum ClipAluminum Clip1”(25.4 mm) GlasRoc Shaftliner Type X3/4”(19 mm)Air SpaceComponent Specifications GlasRoc Shaftliner Type XStandardThicknessWidthLengthsASTM C1396; C1658;CAN/CSA A82.27Surface Burning CharacteristicsGlasRoc Shaftliner Type XSteelC-Track25 ga, 2” (51 mm)1” (25.4 mm)H-Stud25 ga, 2” (51 mm)2’ (610 mm)Aluminum Clip.063” (1.6 mm), 2” (51 mm)3/4”(19 mm)Air SpaceGlasRoc Shaftliner Type XFlame SpreadSmoke DevelopedASTM E84010 Class ACAN/ULC-S102020Standard8’ (2440 mm), 10’ (3050 mm),12’ (3660 mm)Technical ReferencesApprox.Weight4.0 psf (19.5 kg/m2)EdgesDouble BeveledConsult local building codes for regulations in your area. ICC International CodesUL U366, ULC W311 Gypsum Association Publications GA-214, GA-216, and GA-600 ASTM E84 (CAN/ULC-S102), E119 (CAN/ULC-S101, E90ICC ESR-1338Riverbank Acoustical Laboratories TL00-176 and TL00-177National Building Code of CanadaGlasRoc Shaftliner Type X for Area Separation Firewalls Call Toll Free 1-800-233-8990 www.certainteed.com7

Benefits of GlasRoc Shaftliner Type Xfor Area SeparationFirewalls 12 month limited warranty against weather exposure Resists mold growth per ASTM D3273and ASTM G21 Economical and efficient installation Scores and snaps easily with no special handling required UL Classified and ULC Listed for Fire Resistance Rapid ease of installation reduces overallconstruction time and provides a costeffective system Lightweight construction Reduced wall thickness means greaterfloor area Area Separation Firewall ratings up to twohours with high STC Ratings.The Health Product Declaration and logo is owned by the Health Product Declaration Collaborative and is used with permission.Characteristics, properties or performance of materials or systems manufactured by CertainTeed herein described are derived from data obtainedunder controlled test conditions. CertainTeed makes no warranties, express or implied, as to their characteristics, properties or performance underany variations from such conditions in actual construction. CertainTeed assumes no responsibility for the effects of structural movement. The M2Tech and M2Tech Logo marks are trademarks of CertainTeed Gypsum, Inc. The M2Tech mark is registered in the United States.CertainTeed and the tag line “Quality made certain. Satisfaction guaranteed.” are trademarks of CertainTeed Corporation. All other trademarks arethe property of its affiliates and related companies.NOTICE: The information in this document is subject to change without notice. CertainTeed assumes no responsibility for any errors that mayinadvertently appear in this document.TMHealth ProductDECLARA TIONConfidence worth building on. CertainTeed Corporation20 Moores RoadMalvern, PA 19355www.certainteed.com/gypsum 2/10 CertainTeedGypsum.Rev.in01-2016 12/12 d in U.S.A. on recycled Codepaper.No.CTG-2555/.5M

GlasRoc Shaftliner is used in conjunction with CertainTeed gypsum board products in Area Separation Firewalls. Area Separation Firewalls are solid type separation walls assembled using 1" (25.4 mm) GlasRoc Shaftliner gypsum board, metal framing and 1/2" (12.7 mm) M2Tech Moisture and Mold Resistant Board or CertainTeed Regular or

Related Documents:

of CertainTeed siding. 800-233-8990 CertainTeed Sales Support Group Welcome to the CertainTeed Siding Collection This starts with a comprehensive array of exterior products that allow your customers to express their unique personal style. CertainTeed products deliver higher standards in selection,beauty and performance.

KICKOUT FLASHING DETAIL FLASHING WINDOW DETAIL WITH LAP SIDING. SECTION 6: TRIM 7 CertainTeed FiberCement INSTALLATION TIPS AND TECHNIQUES TRIM With CertainTeed FiberCement Siding, we recommend you install either CertainTeed Fib

The CertainTeed vinyl siding warranty provides property owners with a lifetime warranty that is transferable to subsequent owners. 50. CertainTeed Saint-Gobain provides subsequent owners with a prorated 50 year warranty measured from the date of first installation. 51. Defendants' vinyl siding warranty provides that if CertainTeed determines .

CERTAINTEED VENEER PLASTER BASE TYPE C Provides the same use as CertainTeed Veneer Plaster Base plus a specially formulated enhanced Type X core for use in fire-resistive, proprietary Type C designs. Minimum order required, see your CertainTeed Gypsum Territory Manager. 8 (2440 mm) 12 (3660 mm) Regular 1/4 (6.4 mm) 4 (1220 mm) Tapered C 1396

ideal vision: A beautiful new home. CertainTeed’s ColorMax Finishing System fills the spectrum of design possibilities with vivid shades and deep, rich tones. We Paint It So You Don’t Have To. CertainTeed WeatherBoards Fiber Cement Siding is so strong and durable with ColorMax finish that resists fading, everyday bumps and harmful impacts.

Design your Dream Home with the Click of a Mouse CertainTeed created the ColorView tool to help homeowners bring their creative vison to reality. Just look through a photo library of homes to choose one that looks most like your own. Then click on the roof to easily switch designs and see what CertainTeed product looks best.

GYPSUM CEILINGS INSULATION CertainTeed. Your one source solution. CertainTeed Insulation and CertainTeed Machine Works (formerly Unisul) have everything you need for every insulation job. Backed by decades of experience in the insulation industry and outstanding customer

MySQL. Use this link to run it. Main page PhpMyAdmin. The next option in main menu is explore (F8). We can directly access to folder www of the web server (Apache in this case), were html and php files must be located to run properly: Folder www.