Under CabinetRange Hood ª Range HoodQB seriesInstallation Guide & UsersManualIMPORTANT: Read and save these instructions.NOTICE:Installer: Leave this guide with the homeownerHomeowner: Keep this guide for future reference

This product is designed for indoor residential use only.

INSTALLATIONTools Needed .3Parts Supplied .4Venting Requirements .5Mount Heights & Clearance .5-6Calculating Vent System Length .6Venting Methods .7Electrical Requirements .8Preparation .9Installation .10-11Range Hood Operations .12USE & CARETroubleshooting .13Use & Care Information .14Measurements & Diagrams .15-20MAINTENANCECleaning .21Replacing the Filter .21Replacing the Light Bulb .21WARRANTY & SERVICEWarranty .22Contact Us .23

Venting Requirements Height & ClearanceVent system must terminate to the outside(roof or side wall).DO NOT terminate the vent system in an attic or other enclosed area.DO NOT use 4” (10.2 cm) laundry-type wallcaps.Use metal/aluminum vent only. Rigid metal/aluminum vent is recommended.DO NOT use plastic vent.Always keep the duct clean to ensure properairflow.Calculate the following figures before installation:1. Distance from the floor to the ceiling.2. Distance between the floor to the countertop/stove (recommend* 27” to 30”).3. Distance between the countertop/stoveto the range hood.4. Height of hood and duct cover.CabinetHeightRangeHoodHeightUnder CabinetRange hoodFor the most efficient & quiet operation: A distance of 27” to 30” is recommended*between stove top and the bottom of rangehood.It is recommended that the range hood bevented vertically through the roof through 8”(17.8 cm) or bigger round metal/aluminumvent work.The size of the vent should be uniform.Use no more than three 90 elbows.Make sure there is a minimum of 24” (61cm) of straight vent between the elbows ifmore than one elbow is used.DO NOT install two elbows together.The length of vent system and number ofelbows should be kept to a minimum to provide efficient performance.The vent system must have a damper. Ifroof or wall cap has a damper, DO NOTuse damper (if supplied) on top of the rangehood.Use silver tape or duct tape to seal all jointsin the vent system.Use caulking to seal exterior wall or roofopening around the cap.Cabinet or Singlepiece Chimney(Optional)Min: 27”Max: 30”CeilingHeightCountertop/Stove36”CounterTop

IMPORTANT: A minimum of 8” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separately) must be used to maintain maximum airflow efficiency. Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to providedduct. Please use Duct Run Calculation below to compute total available duct run when using elbows, transitionsand caps. ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increaseduct size from 8” to 9” or 10”. If a reducer is used, install a long reducer instead of a pancake reducer. Reducing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening aspossible. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. Minimum mount height between stove top to hood bottom should be no less than 27-inch*. Maximum mount height between stove top to hood bottom should be no higher than 30-inch*. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heatdamage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performanceand efficiency. If available, also refer to stove top manufacturer’s height clearance requirements and recommended hoodmounting height above range.* Due to different ceiling height configurations, recommended height may not be applicable.Minimum Duct Size: Round - 8” minimum Rectangular - 3-1/4 x 10” minimum (requires a 8” to 3-1/4x10” adaptor, not supplied)Calculating Vent System LengthTo calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the systemfrom the recommended maximum duct run.Duct Run Calculation:Recommended maximum run Duct Run Calcuation example:8” or 3-1/4 x 10” duct50 ft One roof cap, two 90º elbow, and one 45º elbow used:0ft 9ft 9ft 5ft 23ft used.Vent piece deductionEach 90º elbow used9 ft Deduct 23ft from 50ft, 27ft maximum available forEach 45º elbow used5 ft straight duct run.Each 8” to 3/14 x 10” transition used7 ftSide wall cap with damper0 ftRoof cap0 ft

8

Page 21

Use and Care Information :Operations:Read and understand all instructions and warnings in this manual before operating the appliance. Save theseinstructions for future reference.Always leave safety grills and lters in place. Without these components, operating blowers could catch on tohair, ngers and loose clothing.NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk ofself combustion is higher when the oil has been used several times.NEVER cook on “open” ames under the range hood. Check deep-fryers during use: Superheated oil may beammable.Cleaning:The saturation of greasy residue in the blower and lters may cause increased in ammability. Keep unit cleanand free of grease and residue build-up at all times to prevent possible res.Filters must be cleaned periodically and free from accumulation of cooking residue (see Cleaning Instructionson Page 22). Old and worn lters must be replaced immediately.DO NOT operate blowers when lters are removed. Never disassemble parts to clean without proper instructions. Disassembly is recommended to be performed by quali ed personnel only. Read and understand allinstructions and warnings in this manual before proceeding.Specifications :Body DesignPower RatingGeneral Input PowerMotor Input PowerAmpereLevels Of Speed ControlNumber Of MotorsMotor TypeFan TypeControl TypeFiltration TypeIlluminationVenting SizeInterference ProtectionSpeci cations :Seamless Stainless Steel, Satin Finish120V / 60Hz (USA & Canada standard)264 266 W (260W 2/3 x 2 W)260 W (130W 130W)3A4 Levels2 MotorsSingle Chamber Ultra QuietCentrifugal Squirrel CageElectronic Control PanelStainless Steel Baf e Filter2/3 x 2 W LEDTop, 8 inches RoundRadio Frequency Interference Protected

Measurements and Diagrams :All measurements in parenthesis are in millimeters.All inch measurements are converted from millimeters, thus inch measurements are estimated.7 - 3 /4" (197mm)7 - 3 /4" (197mm)

ScrubReplacing Filters: Replace filters if they wear out due to age and prolonged use.Replacing the light bulb:1 Remove baffle filter as per installation.2 Make sure the hood is disconnected or close the circuit breaker.Reach into the range hood and disconnect power clip.3 Reach into interior of range hood until touching both lateral clipslocated on the side of the puck light. Gently squeeze and push downuntil puck pops out from its location.4 To reinstall new puck light, follow step 3 inreverse order.

WARRANTY AND SERVICEFor full warranty details on this product please visit:http://www.cosmoappliances.com/warrantyTO RECEIVE WARRANTY SERVICE, YOURPRODUCT MUST BE REGISTERED. TO REGISTER, VISIT:WWW.COSMOAPPLIANCES.COM/WARRANTYSCAN TO REGISTER

IMPORTANTDo Not Return This Product To The Store Ifyou have a problem with this product, please contactCosmo Customer Support at 1(888)784-3108DATED PROOF OF PURCHASE, MODEL #, AND SERIAL #REQUIRED FOR WARRANTY SERVICEIMPORTANTNe pas Réexpédier ce Produit au MagasinPour tout problème concernant ce produit, veuillez contacterle service des consommateurs Cosmo Customer Support au 1(888) 784-3108UNE PREUVE D’ACHAT DATEE EST REQUISE POUR BENEFICIER DELA GARANTIE.IMPORTANTENo regrese este producto a la tiendaSi tiene algún problema con este producto, por favor contacte elAYUDA AL CLIENTE COSMO al 1(888)784-3108(Válido solo en E.U.A).NECESITA UNA PRUEBA DE DE COMPRA FECHADA, NÚMERO DEMODELO Y DE SERIE PARA EL SERVICIO DE LA GARANTÍACorrect Disposal of this product:This marking indicates that this appliance should notbe disposed with other household wastes. To preventpossible harm to the environment or human healthfrom uncontrolled waste disposal, recycle it responsibly topromote the sustainable reuse of material resources.

NOTE:

Cosmo is constantly making efforts to improve the quality andperformance of our products, so we may make changes to ourappliances without updating this manual.Electronic version of this manual is available at:www.cosmoappliances.com

to the range hood. 4. Height of hood and duct cover. For the most efficient & quiet operation: A distance of 27" to 30" is recommended* between stove top and the bottom of range hood. It is recommended that the range hood be vented vertically through the roof through 8" (17.8 cm) or bigger round metal/aluminum vent work.

Related Documents:

Jeep Cherokee 14-21 under seat, DS 60 psi under hood, DS n/a Compass 11-17 under seat, DS 60 psi under hood, DS n/a Gladiator 20-21 under seat, DS 60 psi under hood, DS n/a Grand Cherokee 10-21 under seat, DS 60 psi under hood, DS n/a Liberty 08-12 under seat, DS or PS 60 psi under hood, DS n/a Patriot 11-17 under seat, DS 60 psi under hood, DS n/a

to cabinet tloor 24" mln. range hood to cooklng surface or countertop 15" mln. upper cabinet 13" max. upper cabinet depth Mobile home installation The installation of this range hood must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 . under the cabinet. 1 surface could result in a serious

Cabinet opening dimensions shown are for 25" (63.5 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth, and 36" (91.4 cm) countertop height. Dimensions must be met in order to ensure a flush fit to back wall. IMPORTANT: If installing a range hood or hood liner above the range, follow the range hood or hood liner installation

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood

2. Lift Hood Fan Unit carefully and slip wires out of cavity. SeeFigure 9. CAUTION: Do not pull or stretch hood fan wiring. 3. Rotate the Hood Fan Unit 180 so that the fan blade openings are facing the back of the oven. Note, you will need to lift the wire over the hood fan unit so the wire will clear. See Figure 10 (A). Replace Hood Fan Unit .

Under-cabinet O 21" O other Wall-mount O 24" O 27" O other Island hood O 27" O 30" O other Note: A 27" wall-mount hood extends beyond standard base cabinetry but matches the depth of many pro-styleranges. The deeper the hood, the more chance you have of hitting your head on the lip of the hood. O Island O Liner insert (wood hood .

Level 4 IS Business Analyst Minimum Standards and Grading Criteria This paper defines the minimum requirements for the knowledge, skills and behaviours defined in the standard, which are required for a pass. It also defines the criteria to be used for awarding the grade for merit or distinction. This paper should be read in conjunction with the Standard and Assessment Plan for the Level 4 IS .