MotorProtectionCircuitBreakers

About usLarsen & Toubro is a technology-driven USD 9.8 billion company thatinfuses engineering with imagination. The Company offers a wide range ofadvanced solutions in the field of Engineering, Construction, Electrical &Automation, Machinery and Information Technology.L&T Switchgear, which forms part of the Electrical & Automation business,is India's largest manufacturer of low voltage switchgear, with the scale,sophistication and range to meet global benchmarks. With over fourdecades of experience in this field, the Company today enjoys a leadershipposition in the Indian market with growing presence in internationalmarkets.It offers a complete range of products including controlgear, powergear,motor starters, energy meters, wires and host of other accessories. Most ofour product lines conform to international standards, carry CE markings andarecertified.Switchgear Factory, Mumbai

Product RangeL&T introduces complete range of Supernova products covering Motor Protection Circuit Breakers,Contactors / Thermal Overload Relays & Motors.Motor Protection Circuit BreakersThe new range of MPCBs ismeant for protection againstshort circuit & overload.MO Contactors & RTOThermal Overload RelaysThe latest range of Contactors& Thermal Overload Relays,rated from 9A to 110A.2MotorsL&T offers higher efficiency 3 phase LT motors,synonymous with ruggedness and reliability, suitablefor all industrial applications upto 400 kW.

Motor Protection Circuit BreakersFunctionsMoulded Case Circuit Breaker and Thermal Overload Relay functions integrated into a highly compactunit known as Motor Protection Circuit Breaker.Circuit Breaker FunctionsShort circuit protectionOvercurrent protectionlLine protectionllThermal Overload Relay FunctionsOverload protectionlPhase loss protectionlRated current adjustmentAmbient temperature compensationll}MPCB - AdvantagesCompactnesslHigh Breaking CapacitylShort circuit protective coordinationlReduction in wiring worklEcological design standardslSelecting the Appropriate ModelProcedure for selecting the appropriate model:Confirm the motor's full load currentThree-phase load/Single-phase loadFor applications in a single-phasecircuit, connect the 3-pole in seriesSelect the rated current of MPCBSelect the branch circuit cable & confirm the control panel specificationsConfirm the short-circuit current of the circuitSelect the operating characteristicsSame characteristics as desiredfor a standard thermal overloadrelayAdjustable thermal magnetic trip type MPCBLong-time operating type or quickoperating type thermal overloadrelay desiredInstantaneous trip type MPCB3

Typical Problem in the Conventional Systemand their Solution by using MPCBShort-Circuit Breaking CapacityWhen numerous small and medium motor loads exist in a circuit requiring high breakingcapacity, there is no high breaking capacity circuit breaker with a small rated current for ashort circuit protection.The MPCB can be used in 100kA short circuit current circuits for three-phase, 240Vmotors with rated capacity upto 15kW, and in 50kA short circuit current circuits for threephase, 415V motors with rated capacity up to 30kW.Back-up breaking systemWhen back-up MCCB is installed upstream to solve the problem described in “ Shortcircuit breaking protection ” above, a short in one of the load circuits also trips theupstream breaker and stops the other operating circuits.Despite their compact size, the MPCB provides high-performance short-circuit currentbreaking. They eliminate the need for an upstream circuit breaker for back-up use.Overload ProtectionMotor Protection breakers cannot be adjusted to match the rated current of the motorbeing protected.Equipped with a wide range current adjustment dial (with maximum/minimum ratio of 1.4to 1.6), the MPCB easily adjusts to match the rated current of the motor, for optimumprotection.Control Panel SizeConsiderable space is required to install a back-up circuit breaker or a combination starterconsisting of a circuit breaker and a thermal overload relay. As a result, the panel size hasto be increased.The compact size of the MPCB, including overload relay functions, enables a smallerinstallation area with less wiring space, for a reduction in panel size.4

Technical SpecificationsTypeMOG - S1MOG - H1MOG - H2MOG - H1MMOG - H2MStandardsIEC60947 -1, -2, -4 -1IEC60947 -1, -2, -4 -1IEC60947 -1, -2, -4 -1IEC60947 -1, -2, -4 -1IEC60947-1, -2, -4 -1Handle typeRockerRotaryRotaryRotaryRotaryNumber of poles33333Frame13A32A63A32A63ARated insulation voltage (Ui)AC690VAC690VAC1000VAC690VAC1000VRated operational voltage (Ue)AC200 - 690VAC200 - 690VAC200 - 690VAC200 - 690VAC200 - 690VRated impulse withstand voltage (Uimp)6KV6KV8KV6KV8KVRated frequencyAC50 / 60HzAC50 / 60HzAC50 / 60HzAC50 / 60HzAC50 / 60HzUtilization Category (IEC947 - 4 - 1 / 947 - 2)AC - 3 / Cat. AAC - 3 / Cat. AAC - 3 / Cat. AAC - 3 / Cat. AAC - 3 / Cat. AMaximum motor capacity AC37.5 kW (at 200 - 240V), 15 kW (at 380 - 440V)7.5 kW (at 200 - 240V), 15 kW (at 380 - 440V)15 kW (at 200 - 240V), 30 kW (at 380 - 440V)7.5 kW (at 200 - 240V), 15 kW (at 380 - 440V)15 kW (at 200 - 240V), 30 kW (at 380 - 440V)AC3 Electrical/Mechanical endurance100000 (32A:70000) / 100000 (32A:70000), (25cycles / hour)100000 (32A:70000) / 100000 (32A:70000), (25cycles / hour)25000 / 50000, (25cycles / hour)100000 (32A:70000) / 100000 (32A:70000), (25cycles / hour)25000 / 50000, (25cycles / hour)Tripping deviceThermal - MagneticThermal - MagneticThermal - MagneticMagneticMagneticAmbient temperature compensation-20 C 60 C-20 C 60 C-20 C 60 C-20 C 60 C-20 C 60 COverload, Phase loss protectionyes (according to IEC60947 - 4 - 1)yes (according to IEC60947 - 4 - 1)yes (according to IEC60947 - 4 - 1)NoneNoneTrip IndicatorYesYesYesYesYesTest Trip FunctionYesYesyesYesYesInstantaneous release13 X Ie max.13 x Ie max.13 x Ie max.13 x Ie max.13 x Ie max.Terminal typeScrew terminal, M4 slottedScrew terminal, M4 slottedBox terminal, M6 slottedScrew terminal, M4 slottedBox terminal, M6 slottedSolid/Stranded1 - 10mm2 x 1 / 18 - 8 AWG x 11 - 10mm2 x 1 / 18 - 8 AWG x 11 - 25mm2 x 1 / 18 - 4 AWG x 11 - 10mm2 x 1 / 18 - 8 AWG x 11 - 25mm2 x 1 / 18 - 4 AWG x 1Without/With end sleeve1 - 6mm2 x 2 / 18 - 10 AWG x 21 - 6mm2 x 2 / 18 - 10 AWG x 21 - 16mm2 x 2 / 18 - 4 AWG x 21 - 6mm2 x 2 / 18 - 10 AWG x 21 - 16mm2 x 2 / 18 - 4 AWG x 2Product weight (Kg)0.350.350.780.370.78Dimensions (mm) W x H x D45 x 90 x 6645 x 90 x 6655 x 110 x 9645 x 90 x 7955 x 110 x 96WiresizeStandardserviceconditionRelative humidity45 85%RHNo dew formation or freezing due45 85% RHNo dew formation or freezing due45 85% RHNo dew formation or freezing due45 85% RHNo dew formation or freezing due45 85% RH No dew formation or freezing dueOperation altitudeUp to 2000mto rapid temperature change allowedUp to 2000mto rapid temperature change allowedUp to 2000mto rapid temperature change allowed2000mto rapid temperature change allowedUp to 2000mto rapid temperature change allowedAtmosphere having no excess Vapour, Steam, Dust,Atmosphere having no excess Vapour, Steam, Dust,Atmosphere having no excess Vapour, Steam, Dust,Atmosphere having no excess Vapour, Steam, Dust,Atmosphere having no excess Vapour, Steam, Dust,Corrosive gas, Salt, Flammable gasCorrosive gas, Salt, Flammable gasCorrosive gas, Salt, Flammable gasCorrosive gas, Salt, Flammable gasCorrosive gas, Salt, Flammable gasAtmosphere56

Breaking Capacity at Different VoltagesMOG - S1AC240V AC415V AC460VRatingIe (A)AC230V AC400V AC440VAC500VAC690VAC600VIcu (A)00160.1 - 0.1610010010010010000250.16 - 0.2510010010010010000400.25 - 0.410010010010010000630.4 - 0.6310010010010010001000.63 - 110010010010010001601 - 1.610010010010010002501.6 - 2.5100100100100304002.5 - 4100100100100306304 - 6.31001005050310006.3 - 101001001510313009 - 13100501063MOG - H1MOG - H1MAC240V AC415V AC460VRatingIe (A)AC230V AC400V AC440VAC500VAC690VAC600VAC240V AC415V AC460VRatingIn (A)AC230V AC400V AC440VIcu (A)AC500VAC690VAC600VIcu (A)00160.1 - 0.1610010010010010000160.1610010010010010000250.16 - .25 - 0.410010010010000400.410010010010010000630.4 - 0.6310010010010010000630.6310010010010010001000.63 - 11001001001001000100110010010010010001601 - 1.610010010010010001601.610010010010010002501.6 - 2.5100100100100802502.51001001001008804002.5 - 410010010010004004100100100100806304 - 6.3100100100100606306.3100100100100610006.3 - 10100100505061000101001005050613009 - 131001005042613001310010050426160011 - 16100503510416001610050351044200014 - 201005035102000201005035104250019 - 2510050351042500251005035104320024 - 3210050351043200321005035104MOG - H2MOG - H2MAC240V AC415V AC460VAC230V AC400V AC440VAC500VAC690VAC240V AC415V AC460VAC600VAC230V AC400V AC440VAC690VAC600VRatingIn 0503510556300631005035105RatingIe (A)320024 - 32100503510400028 - 401005035500035 - 501005035630045 - 6310050Icu (A)Icu (A)35AC500V107

Ordering InformationThermal & Magnetic Trip - Rocker TypeFrame size(mm)Rating(A)Motor Rating at415V, 50Hz gnationMOG - S1Thermal ReleaseRange (A)0.1 - 0.16A0.16 - 0.25A0.25 - 0.4A0.4 - 0.63A0.63 -1.0A1.0 - 1.6A1.6 - 2.5A2.5 - 4A4.0 - 6.3A6.3 - 10.0A9.0 - 13.0ACat. mal ReleaseRange (A)Cat. Nos.BreakingCapacity0.1 - 0.16A0.16 - 0.25A0.25 - 0.4A0.4 - 0.63A0.63 - 1.0A1.0 - 1.6A1.6 - 2.5A2.5 - 4.0A4.0 - 6.3A6.3 - 10.0A9.0 - 13.0A11.0 - 16.0A14.0 - 20.0A19.0 - 25.0A24.0 - 32.0A24.0 - 32.0A28.0 - 40.0A35.0 - 50.0A45.0 - OOOST41922OOOOThermal ReleaseRange (A)Cat. OOOST41941OOOO50kAThermal & Magnetic Trip - Rotary TypeFrame size(mm)45mm55mmRating(A)Motor Rating at415V, 50Hz 0020.0025.0034.00TypeDesignationMOG - H1MOG - H2100kA50kAInstantaneous Trip - Rotary TypeFrame size(mm)45mm55mm8Rating(A)Motor Rating at415V, 50Hz 020.0025.0034.00TypeDesignationMOG - H1MMOG - H2MBreakingCapacity100kA50kA

AccessoriesFeaturesAll accessories can be used with MOG S1 (45mm wide), MOG H1 (45mm wide) and MOG H2 (55mm wide) frameslShunt trip and undervoltage trip devices are available in a wide range of operating voltageslIP20 terminal cover prevents accidental contact to electrically charged partslAuxiliary contact blocks : MOG-AXF, MOG-AXLThese blocks are linked to the ON/OFF operation of the MPCB. Up to two contactblocks can be mounted to the right/left front and up to two contact blocks can bemounted to the left side.Alarm contact blocks : MOG-TAFThis block operates when the MPCB trips due to overload, phase-loss, or short-circuit. Itis not linked to the ON/OFF operation of the MPCB.Note : Operation can be checked with the test trip function.Auxiliary and alarm contact blocks : MOG-ATLThis contact block combines auxiliary contact and alarm contact that operate in theevent of an overload, phase loss, or short-circuit. Alarm contact is not linked to theON/OFF operation of the MPCBlAn alarm is displayed in the contact block’s indicator when the alarm contact operateslNote : Operation can be checked with the test trip function.Short-circuit alarm contact block : MOG-SALThe contacts operate only when the MPCB has tripped due to a short-circuitWhen these contacts operate, the blue reset button extends out, and a trip indicationis displayedlThe power to the MPCB can be turned ON after pressing the reset buttonllNote : Operation can not be checked with the test trip function. Be sure to pressthe reset button before mounting to the MPCB.Shunt trip devices : MOG-STThis device is used to remotely trip the MPCB.Notes:lThis device cannot be used together with an undervoltage trip devicelWhen the MPCB trips with the shunt trip device, press the reset buttonbefore turning ON the power9

AccessoriesUndervoltage trip devices : MOG-UVThis device automatically trips the MPCB when the control circuit voltage drops belowthe specified value.Notes:This device cannot be used together with a shunt trip deviceWhen the MPCB has been tripped with the undervoltage trip device, press thereset button before turning ON the powerllExternal operating handles : MOG-EHTo operate the MPCB without opening the panel doorlEquipped with an interlock mechanism that prevents someone from openingthe panel door when the MPCB is in the ON statelThe shaft can be cut to match the distance between the MPCB and the panel doorlDoor interlock functionlOFF lock functionNote: Padlocks not included.lRelease screw allows the door to be opened with the handle in the ON positionlIP54 enclosurelRatings of accessoriesAccessory typePart numberStandard48V.AC AC-15125V AC230V AC400V ACRated operational500V ACcurrent (A)690V AC48V DC DC-13110V DC220V DCMin. voltage and currentAuxiliary contactblock/frontMOG-AXFAuxiliary 0.651.30.5Accessory typeAlarm contactblockMOG-TAFIEC 60947-5-1531.51.380.550.2717V, 5mAVoltage rangeTime rating of coil (s)Note: Ue: Rated Voltage10Short-circuit alarmcontact Undervoltage deviceMOG-UVShunt trip deviceMOG-STStandardRated insulation voltage (V AC)No. of ON-OFF operationsOperating time (ms)Power consumptionAux. and alarmcontact blockMOG-ATLInrush (VA/W)Sealed (VA/W)Tripping voltage (V)Closing voltage (V)IEC 60947-169050002021/128/1.20.7 to 1.1UeAC: ContinuousDC: 50.35 to 0.7Ue0.85 to 1.1UeAC: Continuous

Selection ChartFuseless Protection for DOL Starter Feeders with MPCBMOG-H1M/H2M Type ‘2’ Co-ordination, Iq 50 kA at 415V, 3Ø, 50 Hz as perStandards : IEC 60947-4-1, IS 13947 (Part 4/Sec. 1), EN 60947-4-1The selection is valid only for complete L&T combinations i.e. MPCB Relay ContactorIn any case if this combination is changed to accommodate another brand / rating of MPCB etc. itshall be the responsibility of the person making such a change to assure type 2 performanceSelection is for normal starting conditions with starting timelllAccording to Type ‘2’ Co-ordination, Iq 50kA at 415V, 3Ø, 50HzMotor Rating: 3Ø, 415V, 50HzContactorOverload RelayMPCB (Only Magnetic)Sr. No.hpkWILTypeTypeRange (A)Type10.1250.090.40MO 9MO - RTO10.3 - 0.45MOG - H1M0.6320.160.120.45MO 9MO - RTO10.3 - 0.45MOG - H1M0.6330.20.150.57MO 9MO - RTO10.45 - 0.67MOG - H1M140.250.190.75MO 9MO - RTO10.67 - 1.0MOG - H1M150.330.250.90MO 9MO - RTO10.67 - 1.0MOG - H1M1.660.50.371.20MO 9MO - RTO11.0 - 1.5MOG - H1M1.670.750.551.60MO 9MO - RTO11.2 - 2.1MOG - H1M2.5810.752.10MO 9MO - RTO11.8 - 2.7MOG - H1M2.591.51.102.70MO 9MO - RTO12.4 - 3.6MOG - H1M4101.751.303.00MO 9MO - RTO12.4 - 3.6MOG - H1M41121.503.50MO 9MO - RTO13.5 - 5.0MOG - H1M6.3122.51.804.80MO 9MO - RTO13.5 - 5.0MOG - H1M6.31332.255.00MO 9MO - RTO14.0 - 6.0MOG - H1M6.31443.006.40MO 9MO - RTO16.3 - 9.0MOG - H1M101553.707.90MO 9MO - RTO16.3 - 9.0MOG - H1M10165.54.008.50MO 9MO - RTO16.3 - 9.0MOG - H1M101764.509.00MO 12MO - RTO18.5 - 12.5MOG - H1M13187.55.5011.20MO 12MO - RTO18.5 - 12.5MOG - H1M16Rating IM (A)19107.5014.80MO 18MO - RTO112.5 - 18MOG - H1M202012.59.3019.00MO 25MO - RTO117 - 24MOG - H1M25211511.0022.00MO 25MO - RTO117 - 24MOG - H1M322217.513.0024.00MO 32MO - RTO122- 32MOG - H1M32232015.0029.00MO 32MO - RTO122 - 32MOG - H2M40242518.6035.00MO 40MO - RTO130 - 40MOG - H2M50253022.5040.00MO 40MO - RTO135 - 45MOG - H2M50263526.0047.00MO 50MN 530 - 50MOG - H2M6311

Selection ChartFuseless Protection for DOL Starter Feeders with MPCBMOG-S1/H1/H2 Type '2' Co-ordination, Iq 50 kA at 415V, 3Ø, 50 Hz as perStandards : IEC 60947-4-1, IS 13947 (Part 4/Sec. 1), EN 60947-4-1Motor Rating: 3Ø, 415V, 50HzContactorOverload RelayMPCB (Only Magnetic)Sr. No.hp10.09IL0.40TypeTypeRange (A)TypeRating IM (A)MO 9--MOG - S1 / MOG - H10.4 - 0.63-MOG - S1 / MOG - H10.4 - 0.6320.160.120.45MO 9-30.20.150.57MO 9--MOG - S1 / MOG - H10.63 - 1MO 9--MOG - S1 / MOG - H10.63 - 1MO 9--MOG - S1 / MOG - H11 - 1.6-MOG - S1 / MOG - H11 - 1.6450.250.330.190.250.750.9060.50.371.20MO 9-70.750.551.60MO 9--MOG - S1 / MOG - H11.6 - 2.5MO 9--MOG - S1 / MOG - H11.6 - 2.5-MOG - S1 / MOG - H12.5 - 4810.752.1091.51.102.70MO 9-101.751.303.00MO 9--MOG - S1 / MOG - H12.5 - 4122.51.804.80MO 9--MOG - S1 / MOG - H14 - 6.3MO 9--MOG - S1 / MOG - H14 - 6.3-MOG - S1 / MOG - H16.3 - 101332.255.001443.006.40MO 9-1553.707.90MO 9--MOG - S1 / MOG - H16.3 - 10165.54.008.50MO 9--MOG - S1 / MOG - H116.3 - 10MO 12--MOG - S1 / MOG - H19 - 13-MOG - H111 - 16171867.54.509.005.5011.20MO 12-19107.5014.80MO 18--MOG - H114 - 202012.59.3019.00MO 25--MOG - H119 - 25MO 32--MOG - H124 - 32-MOG - H228 - 402217.513.0024.00232015.0029.00MO 32-242518.6035.00MO 40--MOG - H230 - 50253022.5040.00MO 40--MOG - H235 - 50MO 50--MOG - H240 - 6326120.125kW3526.0047.00

Selection ChartFuseless Protection for DOL Starter Feeders with MPCBMOG-S1/H1/H2 Type '2' Co-ordination, Iq 50 kA at 415V, 3Ø, 50 Hz as perStandards : IEC 60947-4-1, IS 13947 (Part 4/Sec. 1), EN 60947-4-1Motor Rating: 3Ø, 415V, 50HzOverload RelaySr. No.hp1MPCBContactor0.125kW0.09FLC, In (A)TypeRange (A)0.4--TypeRatingMNX 9MOG - S1 / MOG - H10.25 - 0.4MNX 9MOG - S1 / MOG - H10.4 - 0.6320.160.120.45-30.20.150.57--MNX 9MOG - S1 / MOG - H10.4 - 0.630.75--MNX 9MOG - S1 / MOG - H10.63 - 10.9--MNX 9MOG - S1 / MOG - H10.63 - 1-MNX 9MOG - S1 / MOG - H11 - 1.6450.250.330.190.2560.50.371.2-70.750.551.6--MNX 9MOG - S1 / MOG - H11 - 1.62.1--MNX 12MOG - S1 / MOG - H11.6 - 2.5-MNX 12MOG - S1 / MOG - H12.5 - 4810.7591.51.12.7-101.751.33--MNX 12MOG - S1 / MOG - H12.5 - 41121.53.5--MNX 12MOG - S1 / MOG - H12.5 - 44.8--MNX 12MOG - S1 / MOG - H14 - 6.3-MNX 12MOG - S1 / MOG - H14 - 6.3122.51.81332.255-14436.4--MNX 12MOG - S1 / MOG - H16.3 - 101553.77.9--MNX 12MOG - S1 / MOG - H16.3 - 109--MNX 12MOG - S1 / MOG - H16.3 - 105.511.2--MNX 12MOG - S1 / MOG - H19 - 13161767.54.518107.514.8--MNX 18MOG - H111 - 161912.59.319--MNX 25MOG - H114 - 2022--MNX 25MOG - H119 - 25-MNX 32MOG - H119 - 252015112117.51324-22201529--MNX 40MOG - H124 - 32232518.635--MNX 40MOG - H228 - 4040--MNX 45MOG - H228 - 40-MNX 70MOG - H235 - 50243022.525352647-26403055--MNX 80MOG - H245 - 6360--MNX 80MOG-H245 - 63274533.513

Selection ChartFuseless Protection for DOL Starter Feeders with MPCBType MOG-H1M/H2M Type '2' Co-ordination, Iq 50 kA at 415V, 3Ø, 50 Hz as perStandards : IEC 60947-4-1, IS 13947 (Part 4/Sec. 1), EN 60947-4-1Motor Rating, 415V, 3 ph.RelayFLCMPCB (Only Magnetic)Sr. No.14ContactorhpkW(A)TypeRange (A)10.1250.090.4MN20.3 - RatingMNX 12MOG - H1M0.40.45 - 0.75MNX 12MOG - H1M0.63MN20.45 - 0.75MNX 12MOG - H1M0.630.7MN20.6 - 1MNX 12MOG - H1M10.250.9MN20.6 - 1MNX 12MOG - H1M10.50.371.2MN20.9 - 1.5MNX 12MOG - H1M1.670.750.551.6MN21.4 - 2.3MNX 12MOG - H1M1.6810.752.1MN21.4 - 2.3MNX 12MOG - H1M2.591.51.12.7MN22.0 - 3.3MNX 12MOG - H1M4101.751.33MN22.0 - 3.3MNX 12MOG - H1M41121.53.8MN23.0 - 5.0MNX 12MOG - H1M4122.51.84.8MN24.5 - 7.5MNX 12MOG - H1M6.31332.255MN24.5 - 7.5MNX 12MOG - H1M6.314436.2MN24.5 - 7.5MNX 12MOG - H1M101553.77.9MN26 - 10MNX 12MOG - H1M101664.59MN26 - 10MNX 12MOG - H1M10177.55.511.4MN29 - 15MNX 32MOG - H1M1318107.515.4MN214 - 23MNX 32MOG - H1M161912.59.319.5MN214 - 23MNX 32MOG - H1M2020151123MN220 - 33MNX 32MOG - H1M252117.51324MN220 - 33MNX 32MOG - H1M2522201529MN220 - 33MNX 32MOG - H1M32232518.635MN224 - 40MNX 40MOG - H2M40243022.540MN530 - 50MNX 45MOG - H2M5025352647MN530 - 50MNX 70MOG - H2M5026403055MN545 - 75MNX 80MOG - H2M63274533.560MN545 - 75MNX 80MOG - H2M63

IT CharacteristicsType MOG - S1 (0.16A - 13A)Type MOG - H1 (0.16A - 32A)1000010000100010003-poles fromcold state100Average Tripping Time (s)Average Tripping Time (s)3-poles fromcold state2-poles fromcold state10Instantaneous trippingcharacteristic is set at1300% of the maximumcurrent setting3-poles fromhot state10.10.011002-poles fromcold state10Instantaneous trippingcharacteristic is set at1300% of the maximumcurrent setting3-poles fromhot state10.10.010.0010.001100101Multiples of current setting x Ie[A]10100Multiples of current setting x Ie[A]Type MOG - H2 (32A - 63A)100001000Average Tripping Time (s)13-poles fromcold state1002-poles fromcold state101Instantaneous trippingcharacteristic is set at1300% of the maximumcurrent setting3-poles fromhot state0.10.010.001110100Multiples of current setting x Ie[A]15

IT CharacteristicsType MOG - H1M (0.16A - 32A)100001000Tripping Time (s)10010Instabtabeous trippingcharacteristic is set at1100 1560% of therated current10.10.010.001110100Multiples of rated current x In[A]Type MOG - H2M (32A - 63A)100001000Tripping Time (s)10010Instabtabeous trippingcharacteristic is set at1100 1560% of therated current10.10.010.001110Multiples of rated current x In[A]16100

Overall DimensionsType MOG - S1 (0.16A - 13A)45114.314.33L2 562775902432 28275.5T2 6T1 42T345103.762.314.314.3Type MOG - H1 & MOG - H1M (0.16A - 32A)4514.314.31L1 3L2 2432 28275.5T2 6T1 42T3451014.375.33.714.3Type MOG - H2 & MOG - H2M (32A - 63A)107.892.388.35516.54.516.51 L11-3 L25 L31- 2-2-6 - M633.85.511016.31912066458433.82 T14 T26 T351104563 55424.24217

Overall DimensionsTrip Alarm Contact Front 1NO9M 3.521.5MOG-TAFINO10.516.727285.838.8I MOG-TAFINC1.525263.5I 8.518.91S / C Alarm Left 1NO 1NC6648.735.72.818.72.39M3.5Trip indication(reset by hand)5.21MOG-SALICO879047.214.811.84553.670.48586I 63.41888

Overall DimensionsExternal Operating Handle (Applicable for Frame 1 & 2)66A 66 216MMSET RIPES TON3.3OFFMMS28Ø52.6 0.24-Ø3.566RMMS(16)52.6 0.23.7455.51HandleX1.5 524.2OFF68(Ø4 Ø8) 3Type75X minX maxFrame 1 139 289Frame 2 156 306BAux. Contact Front 1NO9M3.5MOG-AXFINO10.521.516.713(23)14(24)38.85.8I MOG-AXFINC111(21)18.912(22)8.5I 19

Overall DimensionsAux. Alarm Left 2NO6648.79 2.835.718.72.3M3.5Indication 8743.4Aux. Contact Left 2NO66Right sideLeft side11.870.453.6452.3M3.514.847.29048.735.718.79 2.815.23.4MOG-AXL2NO MOG-AXL1CO (141)43(143)43(143)42(142)44(144)I32(132)I32(132)

Overall DimensionsShunt trip and under voltage releaseMOG - ST & MOG - UV6648.7182.818.7M3.59047.24570.42.35.2Accessories for MPCBCat. Nos.DescriptionModel NumbersST41942OOOOST41943OOOOST41944OOOOAuxiliary Contact Front mtg. 1NOAuxiliary Contact Front mtg. 1NCAuxiliary Contact Left side mtg. 2NOMOG-AXF 1NOMOG-AXF 1NCMOG-AXL 2NOST41945OOOOST41946OOOOAuxiliary Contact Left side mtg. 1NO 1NCAuxiliary Contact Left side mtg. 2NCMOG-AXL 1COMOG-AXL 2NCST41947OOOOST41948OOOOST41949OOOOTrip Alarm Contact Front mtg. 1NOTrip Alarm Contact Front mtg. 1NCAuxiliary Alarm Left side mtg. 2NOMOG-TAF 1NOMOG-TAF 1NCMOG-ATL 2NOTerminal MarkingNCNOF (Slot1 / Slot 2) 13, 14 (23, 24)11, 12 (21, 22)F (Slot1 / Slot 2)"33, 34 (133, 134)L43, 44 (143, 144)"43, 44 (143, 144) 31, 32 (131, 132)L"31, 32 (131, 132)L41, 42 (141, 142)"27, 28F (Slot 2 only)25, 26F (Slot 2 only)"73, 74L77, 78"85, 8687, 88LPositionST41950OOOO Short circuit alarm Left side mtg. 1NO 1NC MOG-SAL 1COShunt trip 24V DCMOG-STST41951OOOOMOG-STST41952OOOOShunt trip 110V, 50HzMOG-STST42952OOOOShunt trip 230V, 50HzR (one at a time)MOG-UVST41953OOOOUnder Voltage release, 110V, 50HzMOG-UVST41954OOOOUnder Voltage release, 415V, 50HzC1, C2D1, D2F - Front MountingL - LHS MountingR - RHS MountingNote:1) On LHS any 2 accessories can be fitted (Alarm contact followed by Auxiliary contact)lMOG-ATL 2NO MOG-AXL 1COlMOG-SAL 1CO MOG-AXL 1CO2) On RHS only 1 accessory can be fitted (Shunt trip release or Undervoltage release)3) Any 2 Front mounted accessories are possible at a time.lFront mounted TAF to be fitted only in slot 2lFront mounted auxiliary contact can be fitted in slot1 / slot 221

Notes:

Notes:

Electrical Standard Products (ESP) Branch Offices:REGISTERED OFFICE ANDHEAD OFFICEL&T House, Ballard EstateP. O. Box 278Mumbai 400 001Tel: 022-6752 5656Fax: 022-6752 5858Website: www.Larsentoubro.comELECTRICAL STANDARD PRODUCTS (ESP)501, Sakar Complex IOpp. Gandhigram Rly. StationAshram RoadAhmedabad 380 009Tel: 079-66304007-11Fax: 079-26580491 / 66304025e-mail: esp-ahm@LNTEBG.com38, Cubbon Road, Post Box 5098Bangalore 560 001Tel: 080-25020100, 25593613Fax: 080-25580525e-mail: esp-blr@LNTEBG.com131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-4098706 / 7 / 8 / 9Fax: 0755-2769264e-mail: esp-bho@LNTEBG.comPlot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342, 2436696Fax: 0674-2537309e-mail: esp-bbi@LNTEBG.comSCO 32, Sector 26-DMadhya Marg, P. O. Box 14Chandigarh 160 026Tel: 0172-4646841 to 7Fax: 0172-4646802e-mail: esp-chd@LNTEBG.com10, Club House RoadChennai 600 002Tel: 044-28462072 / 4 / 5 / 2109Fax: 044-28462102 / 3e-mail: esp-maa@LNTEBG.com67, Appuswamy RoadPost Bag 7156Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: esp-cbe@LNTEBG.comL&T House, Group MIG - 5PadmanabhpurDurg 491 001Tel: 0788-2213833 / 14 / 28 / 29Fax: 0788-2213820A1/11, Astronauts AvenueBidhan NagarDurgapur 713 212Tel: 0343-2536891 / 8952 / 7844Fax: 0343-2536493e-mail: esp-dgp@LNTEBG.comMilanpur Road, Bamuni MaidanGuwahati 781 021Tel: 0361-2651297Fax: 0361-2551308e-mail: esp-gau@LNTEBG.comII Floor, Vasantha Chambers5-10- 173, Fateh Maidan RoadHyderabad 500004Tel: 040-66720250Fax: 040-23296468e-mail: esp-hyd@LNTEBG.comD-24, Prithvi Raj Road, C-SchemeJaipur 302 001Tel: 0141-2385916 / 8Fax: 0141-2373280e-mail: esp-jai@LNTEBG.comAkashdeep Plaza, 2nd FloorP. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2340864 / 387Fax: 0657-2341250e-mail: esp-jam@LNTEBG.comSkybright Bldg. M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: esp-cok@LNTEBG.com3-B, Shakespeare SaraniKolkata 700 071Tel: 033-44002572 / 3 / 4Fax: 033-22822589e-mail: esp-ccu@LNTEBG.comA28,Indira Nagar, Faizabad RoadUttar Pradesh,Lucknow 226 016Tel: 0522-2312904 / 5 / 6Fax: 0522-2311671e-mail: esp-Lko@LNTEBG.comPlot No. 5184th Main RoadK. K. NagarMadurai 625 020Tel: 0452-2537404, 2521068Fax: 0452-2537552e-mail: esp-mdu@LNTEBG.comEBG North Wing Office - 2Powai CampusMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: esp-bom@LNTEBG.com#12, Shivaji NagarNorth Ambazari RoadNagpur 440 010Tel: 0712- 2260012 / 3Fax: 0712- 2260020 / 30e-mail: esp-nag@LNTEBG.com32, Shivaji MargP. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: esp-del@LNTEBG.comL&T HouseP. O. Box 119191/1, Dhole Patil RoadPune 411 001Tel: 020-26135048Fax: 020-26124910, 26135048e-mail: esp-pnq@LNTEBG.com3rd FloorVishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: esp-sur@LNTEBG.comRadhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 015Tel: 0265- 2311744 / 6613610 / 1 / 2Fax: 0265-2336184e-mail: esp-bar@LNTEBG.com48-8-16, DwarakanagarVisakhapatnam 530 016Tel: 0891-6620411-2 / 3Fax: 0891-6620416e-mail: esp-viz@LNTEBG.comProduct improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.Electrical Standard ProductsLarsen & Toubro LimitedPowai Campus, Mumbai 400 072Customer Interaction Center (CIC)BSNL / MTNL (toll free) : 1800 233 5858Reliance (toll free): 1800 200 5858Tel : 022 6774 5858Fax : 022 6774 5859E-mail : cic@LNTEBG.comWebsite : www.LNTEBG.comSP 50455 R1030910

Procedure for selecting the appropriate model: Selecting the Appropriate Model Motor Protection Circuit Breakers Circuit Breaker Functions Short circuit protection Overcurrent protection Compactness Line protection l l l . AC - 3 / Cat. A 7.5 kW (at 200 - 240V), 15 kW (at 380 - 440V) 100000 (32A:70000) / 100000 (32A:70000), (25cycles / hour)

Related Documents:

molded-case circuit breakers (MCCB), insulated-case circuit breakers (ICCB) and low voltage power circuit breakers LVPCB). Insulated-case circuit breakers are designed to meet the standards for molded-case circuit breakers. Low voltage power circuit breakers comply with the following standards: ANSI Std. C37.16—Preferred Ratings

Air Circuit Breakers Fixed Version for Power Distribution Emax 2 Icu 100kA - 200kA 4.14 . Air Circuit Breakers Accessories 4.16. 4 1SWC 010 000 C 0314 7 Circuit Breakers: 2 ABB SA LV Products Prices exclude VAT, subject to change without notice E & O.E. Terms & Conditions Apply Moulded Case Circuit Breakers

www.schneider-electric.us 1 . QO Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 QO Arc-Fault Circuit Breaker QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. .

1-38 Siemens Industry, Inc. SPEEDFAX 2017 Product Catalog 1 LOAD CENTERS & CIRCUIT BREAKERS Circuit Breakers Special Application Breakers Product Category RESI n Built to order. Allow 2–3 weeks for delivery. Note: All circuit breakers on this page are 10K AIC a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Switching Neutral

Siemens LV 10 · 04/2020 Miniature Circuit Breakers Miniature Circuit Breakers All the information you need 3/2 Devices for all applications 3/4 System overview 3/5 Quick selection guide 3/6 Miniature circuit breakers 3/6 Device protection switches 3/10 Basic units 3/12 5SL3 miniature circuit breakers 3/12

Circuit Breaker Limitation Capability . Miniature Circuit Breakers – up to 63A C60a – 4.5kA 2 C60N – 6kA 3 C60H – 10kA 4 C32H-DC – 10kA 18 . Page 2 Schneider Electric Help Centre: 1300 369 233 protection circuit-breakers up to 63 A C60a circuit-breakers 4.5 kA, C curve

Short form catalogue. 3 Moulded Case Breakers 0914 ABB Low Voltage. 3 Moulded Case Breakers 0115 ABB Low Voltage Power breakers Tmax Moulded case circuit breakers Contents Overview 4 . Key lock on the motor Type

answer choices you are marking on your answer sheet.-4-GO ON TO THE NEXT PAGE Language Arts – Reading Time — 25 minutes 19 Questions GO ON TO THE NEXT PAGE -5-GO ON TO THE NEXT PAGE A violent storm has threatened the first voyage of the ship Nan-Shan. This excerpt from a work of fiction portrays several crew members, including the first mate, Jukes, as they confront the storm. Jukes was as .