product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsHomeWorks QS Wired Maestro local controlsfunction much like standard dimmers and switches,but can be controlled as part of a lighting controlsystem. Local lighting controls are useful in locationswhere single circuits of lighting need to be dimmedor switched. Local fan speed controls are useful inlocations where control of a single ceiling paddle fan isneeded.DimmerHomeWorks QS Wired Maestro dimmersincorporate advanced features such as fade on / fadeoff, delayed long fade to off, and rapid full on.HomeWorks QS Wired Maestro local controlsinclude a Front Accessible Service Switch (FASSTM) forsafe lamp replacement. HomeWorks QS RF Maestro local controls install in single-pole or multi-locationapplications. Remote dimmers / switches are availablefor multi-location control.RemoteDimmerUse Lutron Nova T* wallplates. Wallplates are soldSwitchFan SpeedRemoteSwitchseparately. Lutron Nova T* wallplates snap on withno visible means of attachment. HomeWorks QSWired Maestro local controls support color changekits.Model NumbersDimmersIncandescent/Magnetic Low-voltageHWA-6D-XX*600 W/600 VA DimmerHWA-6ND-XX*600 W/600 VA DimmerHWA-10D-XX*1000 W/1000 VA DimmerHWA-10ND-XX*1000 W/1000 VA DimmerSwitchesHWA-8ANS-XX*8 A Lighting, 5.8 A MotorNeutral Electronic SwitchFan Speed ControlSingle ceiling paddle fan only (120 V )HWA-2ANF-XX*2 A Neutral Fan SpeedControlRemotes (for multi-location installations)HQA-RD-XX*Remote Dimmer (120 V )HQA-RS-XX*Remote Switch (120 V )Color Change KitsRKA-D-XX*Dimmers (-6D, -6ND,-10D, -10ND)RKA-S-XX*Switches (-8ANS)RKA-AD-XX*Remote Dimmer (-RD)RKA-AS-XX*Remote Switch (-RS)RKA-F-XX*Fan Speed Control (-2ANF)*“XX” in the model number represents color/finish code.See Colors and Finishes at end of document.1 Lutron 24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsSpecificationsModel NumbersDimmer: HWA-6D-XX, HWA-6ND-XX, HWA-10D-XX, HWA-10ND-XXSwitch: HWA-8ANS-XXFan Speed Control: HWA-2ANF-XXRemote: HQA-RD-XX, HQA-RS-XXColor Change Kits: RKA-D-XX, RKA-S-XX, RKA-AD-XX, RKA-AS-XX, RKA-F-XXPower120 V 50 / 60 Hz (-6D, -6ND, -10D, -10ND, -2ANF, -8ANS, -RD, -RS)Typical PowerConsumptionDimmer / Switch / Fan Speed Control: 0.75 WTest conditions: load is off and nightlight mode is enabled.Remote Dimmer / Switch: 0 W Test conditions: load is off.UL, CSA, and NOMRegulatoryApprovalsEnvironmentAmbient operating temperature: 32 F to 104 F (0 C to 40 C), 0% to 90%humidity, non-condensing. Indoor use only.Communications Wired Local Controls are wired to a HomeWorksR dimmer Hub (HWI-H48). Onepair twisted shielded 22 AWG to 18 AWG (0.5 mm2 to 1.0 mm2) IEC PELV/NECRClass 2 wiring.CapacityEach HomeWorksR Dimmer Hub (HWI-H48) is capable of directly controllingup to 48 Wired MaestroR Local Controls. Up to 8 Wired Local Controls may bewired to a single bus on the HWI-H48. Refer to IEC PELV/NECR Class 2 wiring.ESD ProtectionTested to withstand electrostatic discharge without damage or memory loss, inaccordance with IEC 61000-4-2.Surge Protection Tested to withstand surge voltages without damage or loss of operation, inaccordance with IEEE C62.41-1991 Recommended Practice on Surge Voltagesin Low-Voltage AC Power Circuits.Power FailurePower failure memory: should power be interrupted, the control will return to itsprevious state when power is restored.MountingRequires a U.S. wallbox. 3 ½ in (89 mm) deep recommended, 2 ¼ in (57 mm)deep minimum.WiringWarranty2 Lutron Uses conventional 3-way and 4-way ary/warranty.pdf24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsDesign FeaturesDimmer On a single-tap, lights fade ON or OFF. On a double-tap, lights go to full ON. When ON, press and hold the tapswitch toengage the delayed long fade to OFF. Light levels can be fine-tuned by pressing andholding the dimming rocker until the desiredlight level is reached. Neutral and two-wire dimmers available.Switch On a single-tap, lights or motors turn ON orOFF. Requires a neutral connection.Fan Speed Control On a single-tap, fan turns ON or OFF. Fan speeds can be selected by pressing andholding the fan speed control rocker until thedesired fan speed is reached. Controls one paddle type ceiling fan (Permanentsplit-capacitor motor) up to 2 A. Not for use withshaded-pole type motors (i.e. bath exhaust fans). Provides four (4) quiet speeds plus OFF. Not for use with fans that have integrated fanspeed and/or light control modules. Requires a neutral connection.DimensionsAll dimensions are shown as in(mm)Front ViewSide ViewSide View-2ANF only4 11 16(119)2 15 16(75)3 Lutron 5/16(8)1 1 8(30)5/16(8)1 11 16(43)24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsMounting and Parts IdentificationControlMounting wsWallboxControlWallplate Adapter / Wallplatepurchased separately.Ganging and DeratingWhen combining controls in the same wallbox, derating is required. See Load Type and Capacity. No derating is requiredfor remote dimmers / switches / fan speed controls. -8ANS has fins that need to be removed for multigang installations.-8ANS only:Do not remove outside finson end of gang controlsEach control hasinside fins removed4 Lutron Middle of gang controlhas all fins removed24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsLoad Type and CapacityControlHWA-6D1HWA-6NDLoad TypeMinimum LoadNotGangedEnd ofGangMiddle of NeutralGangConnectionIncand.50 W600 W500 W400 WMLV250 W / VA450 W /600 VA400 W /500 VA300 W /400 VAIncand.10 W600 W500 W400 WMLV210 W / VA450 W /600 VA400 W /500 VA300 W /400 VAIncand.50 W1000 W800 W650 WMLV250 W / VA800 W /1000 VA600 W /800 VA500 W /650 VAIncand.10 W1000 W800 W650 WMLV210 W / VA800 W /1000 VA600 W /800 VA500 W /650 VALighting10 W8A6.5 A5AMotor0.083 A1/4 HP5.8 A5.8 A5ACeiling Fan0.083 A2A2A2A1, 5HWA-10D1HWA-10ND1, 5HWA-8ANS4, 7HWA-2ANF6NOYESNOYESYESYES1 Dimmer Load Type: -6D, -6ND,-10D, and -10ND are designed for use with permanently installed incandescent, magneticlow-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances.2 Low-Voltage Applications: Use -6D, -6ND, -10D and -10ND with magnetic (core and coil) low-voltage transformers only.Not for use with electronic (solid-state) low-voltage transformers.Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and prematurefailure. Lutron strongly recommends the following: Do not operate low-voltage circuits without operative lamps in place. Replace burned-out lamps as soon as possible. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failuredue to overcurrent.3 Switch Load Type: -8ANS is designed for use with all permanently installed lighting loads and with motor loads up to1/4 HP (5.8 A)4 Ceiling Fan Application (HWA-2ANF): Use to control one paddle-type ceiling fan (permanent split-capacitor). Use the ceiling fan’s pull chain to set its speed to the highest setting*. Do not use to control fans that use shaded-pole motors (i.e. bath exhaust fans). Do not use to control fans that have integrated fan speed controls (i.e. fans that have a remote control), unless theintegrated control is removed from the ceiling fan. Do not connect to any other motor-operated appliance or to any lighting load type. Do not use to control a fan lighting load (i.e. lighting kit).*See Application Note # 217 “HomeWorksR MaestroR Controls Reference” for more information.5 Can control the following power boosters/load interfaces: Hi-Power Boosters (HP-2, HP-4, HP-6), 0-10 Volt Interface(GFX-TVI), Minimum Load Interface (LUT-LBX), Phase Adaptive Power Module (PHPM-PA), Switched Power Module(PHPM-SW), 3-Wire Flourescent Power Module (PHPM-3F).5 Lutron 24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsOperationDimmerSwitchStatus LEDs(not on Remote Dimmers) Indicatelight level; glow softly as night lightwhen light is offDimming RockerPress to brightenPress to dimStatus LED(not on Remote Switches) Indicatesload status; glows softly as nightlight when light is offTapswitchTap on / offTapswitchTap on / cessibleServiceSwitchFan Speed ControlStatus LEDsIndicate speed level; glow softly asnight light when fan is offSpeed Control RockerPress to increase speedPress to decrease speedTapswitchTap on / offIMPORTANT NOTICE:FASSTM - Front Accessible Service SwitchTo replace bulb, remove power by pullingthe FASSTM switch out fully on all controllingdevices.After replacing bulb(s), push the FASSTMswitch(es) back in fully to restore power to thecontrol(s).FASSTMFrontAccessibleServiceSwitch6 Lutron 24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsWiringDimmer communications wiring may be in adaisy chain, star, or t-tap configuration. Eachhome run on a bus may be up to 500 ft(152 m) and may contain up to 8 devices.The total length of wire on each bus (all homeruns) may be up to 1000 ft (305 m). Up to 48HomeWorksR Wired MaestroR Local Controlsmay be wired to the HomeWorksR DimmerHub (HWI-H48). Up to four HWI-H48’s may beplaced on each processor link configured as anH48 link in the HomeWorksR software.Dimmer Side ViewIEC PELV/NECR Class 2wiring to HomeWorksRdimmer Hub or other WiredMaestroR devicesButt SplicesDrywallWall BoxDimmer BackcoverIEC PELV/NECR Class 2 Wire TypeOne pair twisted shielded 22 AWG to 18 AWG(0.5 mm2 to 1.0 mm2) IEC PELV/NECR Class 2wiring.HWI-H48 Dimmer HubGrayVioletGrayVioletGrayVioletUp to 8 devicesmay be wired toeach bus on theH48.One pair twisted shielded 22 AWGto 18 AWG (0.5 mm2 to 1.0mm2) IECPELV/NECR Class 2 wiring.Maximum 500 ft (152 m) per homerun, maximum 1000 ft (305 m) totalper bus (non-polarized).7 Lutron 24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsWiring DiagramsWiring Diagram 1Wiring Diagram 211Single Location Installation with Neutral-6ND, -10ND, -2ANF and -8ANSSingle Location Installation without Neutral-6D and -10DDimmer/SwitchVioletDimmer / Switch /Fan Speed ControlViolet To HomeWorksR DimmerTo HomeWorksR Dimmer(HWI-H48) or next Wired} HubMaestroR Local Control}Hub (HWI-H48) or next WiredGray MaestroR Local ControlGrayBrassBlue - unused, Tighten1Hot/LiveHot/LiveBlackBrassSilverBlue - unused, Tighten1BlackGreenGreen120 V 50 / 60 HzLoad120 V 50 / 60 HzLoadGroundGroundNeutralNeutralWiring Diagram 32Multi-Location Installation without Neutral-6D and -10D with HQA-RDRemote Dimmeror DimmerRemote Dimmeror DimmerDimmer orRemote Dimmer Violet To HomeWorksR Dimmer(HWI-H48) or next Wired}HubMaestroR Local ControlGrayBrassBrassBlueBlueBrassNote: Dimmer can be installedin any location in the circuit.BlueHot/LiveBlack120 V 50 / 60 eutralWiring Diagram 42, 3Multi-Location Installation with Neutral-6ND, -10ND, and -2ANF with HQA-RD; -8ANS with HQA-RSRemote Dimmer / SwitchRemote Dimmer / SwitchDimmer / Switch/Fan Speed Control4VioletTo HomeWorksR Dimmer(HWI-H48) or next Wired} HubMaestroR Local ckBlack120 V 50 / 60 eutral1When using controls in single location installations, tighten the blue terminal. DO NOT connect the blue terminal to any other wiring or to ground.2Up to 9 HomeWorksR MaestroR Remote Dimmers / Switches may be connected to the HomeWorksR Wired MaestroR Dimmer / Switch / Fan Speed Controls. Totalblue terminal wire length may be up to 250 ft (76 m).4Neutral wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation.8 Lutron 24/7 Technical Support—800.523.9466

product specifications369701a11.05.12HomeWorksR QS Wired MaestroR Architectural Local ControlsColors and FinishesArchitectural Matte FinishesArchitectural Metal Finishes (wallplates only)WhiteWHIvoryIVSatin BrassSBBright BrassBBBright ChromeBCAlmondALLightAlmondLAClear AnodizedAluminumCLABlack AnodizedAluminumBLABrass AnodizedAluminumBRAGrayGRBrownBRAntique BrassQBAntique BronzeQZSatin ChromeSCBlackBLTaupeTPSatin NickelSNBright NickelBNGoldAUWhen ordering metal wallplates,it is recommended to orderthe MaestroR Control in Black (BL).SiennaSIBeigeBE Due to printing limitations, colors and finishesshown cannot be guaranteed to perfectlymatch actual product colors. Color chip keychains are available for moreprecise color matching:Architectural Matte Finishes- AM-CK-1Architectural Metal Finishes - AMTL-CK-19 Lutron 24/7 Technical Support—800.523.9466

HWA-6D-XX* 600 W/600 VA Dimmer HWA-6ND-XX* 600 W/600 VA Dimmer HWA-10D-XX* 1000 W/1000 VA Dimmer HWA-10ND-XX* 1000 W/1000 VA Dimmer Switches HWA-8ANS-XX* 8 A Lighting, 5.8 A Motor Neutral Electronic Switch Fan Speed Control Single ceiling paddle fan only (120 V ) HWA-2ANF-XX* 2 A Neutral Fan Speed Control Remotes (for multi-location installations)

Related Documents:

Designer keypads www.lutron.com 1 Technical Support: 1.800.523.9466 (USA) HomeWorksR QS RF seeTouchR Designer keypads provide homeowners with a simple and elegant way to operate lights, shades / draperies, motorized screens, thermostats, and many other devices. HomeWorksR QS RF seeTouchR Designer keypads feature large, easy-to-use buttons, plus

Is the wired Arlo Essential Video Doorbellcompatible with my existing Arlo system? Yes. The wired Arlo Essential Video Doorbell doesn’t require a base station or SmartHub but it can still be configured to trigger recordings on other cameras or vice versa. Can I pair the wired A

Wireless connection to a wired network Your access point connects a wireless network to a wired network. In this model, your computer is configured for wired networking and is connected with an

Monitor Type TFT LCD Quad View Color w/ Sunshade & Flush-mount - for up to 4 Cameras TFT LCD Color - for up to 2 Cameras TFT LCD Color - for up to 3 Cameras Wired/Wireless Wired Systems Wired Systems Wired Systems Screen Size 10.1" 7" 7" Dot Resolution 1024 x 600 800 x 3 (RGB) x 480 800 x 3

Brother 7065dn manual . Ten-key pad - - Paper Edge Actuator - - Model MFC-7360 DCP-7070DW HL-2280DW MFC-7360N MFC-7362N MFC-7460DN MFC-7470D MFC-7860DN MFC-7860DW Wired / Wireless LAN - Wired Wired - Wired Duplex printing - - ADF 9 9 9 9 9 (Only for China) 9 9 9 - - (For Asia & China) 9 9 9 (Only for China) - Ten-key pad 9 9 9 9 9 9 Paper .

Wireless Network Types -2 . 20. 3. A multiple access point network . is similar to wired network extension types, but several access points are used, usually to cover a wide area or serve many clients. 4. LAN to LAN (or wired to wired) wireless networks bridge wired networks. Wireless Network Ty

5. Connect your network devices We recommend you to first connect one computer/tablet (if possible via a wired connection), then complete the rest of the procedure and as a final step connect the other (wired and/or wireless) devices. 5.1. Connect your wired (Ethernet) devices If you want to connect a device using a wired (Ethernet) connection:

standard , and tick applicability , Say How notes column , Risk and opportunities column , . (ISO 14001 requirement) Clause 6.1.4 Planning action Elimination of hazards and risks –either by the OH & S system or other BMS. Cross reference to Clause 8 (controls) and Clause 9 (M & M) Tip 8 Add plans to excel work book for year . Clause 6.2.1 OH & S objectives at all levels & Clause 6.2.2 .