Daikin Gas Heat Pump

1y ago
7 Views
2 Downloads
6.82 MB
39 Pages
Last View : 2m ago
Last Download : 3m ago
Upload by : Nora Drum
Transcription

APCVAU1606WarningAsk a qualified installer or contractor to install this product. Do not try to install the product yourself.Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer orcontractor to install those parts and accessories. Use of unauthorised parts and accessories orimproper installation of parts and accessories can result in water or refrigerant leakage, electricalshock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides importantsafety instructions and warnings. Be sure to follow these instructions and warnings.Use only the specified type of gas for the outdoor unit.Do not install the outdoor unit inside.Install the outdoor unit where the exhaust gas discharged from connection pipes and/or airsupply/exhaust vent etc. cannot get into the inside of the buildings. Exhaust gas must beemitted to atmospheric air free from potential effects; it must not be discharged into drainagechannels or ditches.If you have any enquiries, please contact your local importer, distributor and/or retailer.Cautions on product corrosion1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to installthe outdoor unit close to the sea shore, contact your local distributor.DAIKINGASHEAT PUMPAIR CONDITIONING SYSTEMSpecifications, designs and other content appearing in this brochure are current as of May 2016 but subject to change without notice.c All rights reservedADHeat Pump / Heat Recovery 50 Hz

Air Conditioned Comfort, Powered by Natural Gas.Benefits of Gas Heat Pump (GHP)Daikin's Gas Heat Pump (GHP) air conditioning system is designed tooperate primarily on natural gas. GHP systems consume less electricalpower than conventional Electrical Heat Pump systems, whilstdelivering air conditioned comfort to the modern building.Lower CO 2 EmissionNatural gas is used as the main energysource. Natural gas emissions arecomparatively lower than other fossil fuels.CO2 emissionsThis unique gas powered air conditioning system is available both as aHeat Pump and Heat Recovery system to suit a broad range ofapplications, and when combined with an Electrical Heat Pump systemcan provide an enhanced value proposition.10080Coal60Natural gasPetroleumReduced Power ConsumptionWhat is GHP ?The compressor is the heart of anair conditioner and consumesthe most energy. In a Gas Heat Pump (GHP)air conditioner, the compressor isdriven by a gas engine using natural gas,whereas an Electric Heat Pump (EHP)uses an electric motor.Indoor UnitImage ofheatingIn GHP system, only the condenserfans and the indoor units consumeelectricity. In comparison to EHP, theelectrical power required to operateGHP is significantly less, therebyenabling the electrical substation andswitch gear equipment to bedownsized compared to EHP.Power consumption100Fans10HeatexchangerE HPCompressor* CO2 emissions from coal 100.* Source: Natural Gas Prospects 2010, 1986/EA Report on Thermal Power Plant AtmosphericImpact Assessment Technology DemonstrationSurveys, March 1990/Institute of Applied EnergyGHP* Power consumption of the EHP 100.GasElectricityAs the load changes during the day, GHP systems are able to match the varying loadby adjusting compressor capacity output through engine speed control.GHPEHPTimeHeating capacityHow is capacity controlled?01Rapid and Powerful HeatingOutdoor UnitRoom temperatureGas engine-10 C Outdoor temperatureGHPEHP10 CThe ability to harness the waste heatfrom the coolant circuit enables rapidand powerful heating performance.This feature also results in lessfrequent defrost operation for GHPsystems.Comparison of heating start speed and heating capacity (image)02

3 Types available to various applicationDaikin offers a range of Heat Pump and Heat Recovery systemsthat are ideally suited for wide range of applications.Heat Pump Standard SeriesFootprint 1.46 m16-25 classHeat Pump Large-capacity SeriesCentralised controlCompact and Light WeightFootprint 1.23 m28-13 class2Outdoor Unit LineupHeat Pump Large-capacity SeriesBy controlling both EHP and GHP systems off a common centralised control system,the designer can capitalize on the unique characteristic and features of bothsystems to deliver an engineered solution that meets the demands of the modern building.Weight : 565 kg13 class seriesControl is centralisedby one controller.DWeight : 745 kg-NET communication20 class seriesSpace Saving DesignBoth systems can becontrolled by thecentralised controller,which makes it simple tooperate.GHP SystemDOutdoor Unit LineupHeat Pump Standard SeriesCombine with VRV system-NET communicationVRV SystemOutdoor Unit LineupHeat Recovery SeriesOutdoor Unit LineupSYSTEM(Electric Heat Pump)Space Saving DesignSimultaneous Heating and Cooling OperationFootprint 1.35 m220 classIndoor units with constantcomfort and unified designSince both systems areconnected to the same indoorunits, both the comfort leveland operation procedures arethe same. The designs offront panels, etc. can also beconsistent.Footprint 1.68 m230 classFor Replacement UseWater Cooled ModelFor Small-sized BuildingControl SystemsHeat Recovery SeriesIndoor Unit LineupFootprint 1.68 m230 classCapacity rangeHeat pumpstandard seriesHeat pumplarge-capacity seriesHeat recovery series0322.4 kW28.0 kW35.5 kW45.0 kW56.0 kW71.0 kW85.0 kW8 class10 class13 class16 class20 class25 class30 classCommon models of indoor unitsCommon models of indoor unitsCommon indoor models for both GHP and EHP systems ensurea consistent look for exposed units whilst maintaining similarcomfort levels and keeping operational control.Air TreatmentEquipment LineupDAIKIN GAS HEAT PUMP AIR CONDITIONING SYSTEM LINEUP04

Outdoor Unit LineupHeat Pump Standard SeriesOutdoor Unit LineupHeat Pump – Standard Series 8/10/13/16/20/25 classCompact DesignInstallation FlexibilityCompact, lightweight outdoor units increase installation flexibility.Long piping length8 / 10 / 13class seriesThe long piping length provides more design flexibility, to meet the needs of large commercial buildings.16 / 20 / 25class seriesWeight :565 kg2,077mmMax. actualpiping length20 class series165 m745 kg2,077mm13 class seriesWeight :880 mm880 mmMax. equivalentpiping length190 m*1aMax. total piping length520 m1,400 mm1,660 mmFirst indoor branchMax. level differenceFootprint 1.23 m2bhedcijbetween the outdoor units andthe indoor unitsFootprint 1.46 m2gfkOutdoor unit above indoor unit:Compact size allows the outdoor unitto be transported in an elevator.The compact outdoor unit can be installed onthe service balcony of each floor.(Unit: mm)External staticpressure:30 Pa50 mOutdoor unit below indoor unit:40 mColours in the diagram above are merely for identifying pipes referenced with symbols such as a .Actualpiping length*1ElevatorOutdoor unitOutdoor unit8 / 10 / 13 class series2,0771,400* Check the dimensions ofthe elevator to be used.* Allow the specified space for service.A discharge duct may need to beinstalled on the outdoor unit.Maximumallowablepiping length*1. Field setting is necessary.880Maximumallowablelevel differenceWide Operating RangeQuiet OperationSystem can operate under a wide rangeof outdoor temperature.Use of edge technology delivers quietoperations. Enabling the quiet mode furtherlowers operating noise levels.HeatingCooling 10 C 10 C18 C43 CdB(A) 6055545256574540Easy Maintenance10 class13 class* The outdoor unit enterspower-saving operation in quietmode.Frequent oil change is not required.Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 30,000hrs of operation.* Use the engine oil specified by Daikin.05a f g h i190 m *1520 ma b c d e f g h i—Between the first indoor branch and the farthest indoor unit60 mf g h i—LevelDifferenceExample15 mkIf the outdoor unit is above.50 mjIf the outdoor unit is below.40 mjBetween the indoor unitsBetween the outdoor unitsand the indoor unitsConnection ratioMaximum connection ratio is 130%.Connection ratio50%–130%Normal modeQuiet mode508 class165 mTotal piping length*1. When the equivalent piping length between outdoor and indoor units is 100 m or more, the size of main pipes (both gas-side and liquid-side) must beincreased.Refer to the Engineering Data Book.5954Equivalentpiping lengthRefrigerant piping lengthMaintenancespaceBalconyExampleConnection ratio Total capacity index of the indoor unitsCapacity index of the outdoor unitsOutdoor unit combinationModel name 025Capacityindex200250320400500630Total capacity index of connectable indoor units *2Combination (%) 60325416520650819Maximum number ofconnectable indoor units131620263341*1.Only single outdoor unit can be connected.*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.06

Outdoor Unit LineupHeat Pump Standard SeriesOutdoor Unit LineupHeat Pump – Standard Series 8/10/13/16/20/25 classOperation rangeINDOOR TEMPERATURE ( CWB)Cooling operationModelGYAQ8ANV1GYAQ10ANV1Power vory white l gasconsumption crollx2TypeTypePropeller fanNumber of units222222Motor outputW275x2275x2275x2350 600350 600600x2Airflow 15.915.9GasDriveRefrigerantPipingDirect drivemm19.122.225.428.628.631.8Fuel gas pipeinchR3/4R3/4R3/4R3/4R3/4R3/4Exhaust vent outside dia.mm808080100100100Drain pipe for exhaust inside dia. htRefrigerantTypeChargekgEngine Lubricant TypeEnginecoolantType14-1043-100102030OUTDOOR TEMPERATURE ( CDB)40OPERATION1010-30-10-20-101801020OUTDOOR TEMPERATURE ( CWB)OptionsOption nameCool/Heat selector *1Fixing boxHarness kit for Cool/Heat Selector *2REFNET GYAQ25ANV1KRC19-26AKJB111AAGKRC19E1KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 P26A72TDistributivepipingREFNET ipe size reducerAntivibration mount *3Air direction adjuster *4Deodorizer K-GBM710BAGFJ560E2AGBJ560E1*1. The Cool/Heat Selector is required when selecting cool/heat mode from the outdoor unit.*2. The harness kit is required when using the Cooling/Heating Selector.*3. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.The specified antivibration mount must be used. Otherwise abnormal vibration may occur.*4. The Air direction adjuster is designed to prevent snow from accumulating on the air outlet of the outdoor unit and to change the air direction to the front or back if the air outlet isblocked by an obstacle. If The Air direction adjuster is installed, the operation sound may increase slightly depending on ambient conditions.Aisin Coolant SFreezing ng 165190/165190/165Height difference between O/U is above mindoor and out door units O/U is below m505050505050404040404040Height difference between indoor units 0-13050-130Connectable indoor units0710RANGE FOR CONTINUOUS OPERATIONRANGE FOR CONTINUOUS20Aisin Gas Engine Oil L-10000GNormal modeSoundpressure level Quiet modeNote:2028* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.Dimensions WidthFans2430GYAQ25ANV1Btu/hCasing colour (Munsell no.)Compressor30Natural gaskWHeatingGYAQ20ANV11- phase , 230 V , 50 HzTypeCoolingGYAQ16ANV1Heating operationINDOOR TEMPERATURE ( CDB)Specificationsnumbercapacity%1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m2 Indoor temp.: 20 CDB / outdoor temp.: 7 CDB, 6 CWB/ Equivalent piping length: 7.5 m, level difference: 0 m08

Outdoor Unit LineupSpace Saving DesignInstallation flexibilitySpace saving design allows forflexible installation.Long piping lengthWeight :Outdoor Unit LineupHeat Pump Large-capacity SeriesHeat Pump – Large Capacity Series 30 classThe long piping length provides more design flexibility, which can match even large-sized buildings.1080 kg2,170mmMax. actualpiping lengthFootprint 1.68 m2800 mmMax. equivalentpiping length170 m200 maMax. total piping length640 m2,100 mmThe compact outdoor unit can be installed on the service balcony of each floor.External staticpressure:First indoor branchcMaintenancespace*1. Field setting is necessary.Wider Operating RangeSystem can operate under a widerrange of outdoor temperature.Heating 21 C18 CCooling 10 C46 CQuiet OperationkColours in the diagram above are merely for identifying pipes referenced with symbols such as a .dB(A) 6560Maximumallowablepiping lengthMaximum allowablelevel differenceUse of edge technology delivers quietoperations. Enabling the quiet modefurther lowers operating noise levels.i50 mActualpiping lengthBalconyedbetween the outdoor units andthe indoor units*1* Allow the specified space for service.A discharge duct may need to beinstalled on the outdoor unit.bhjMax. level difference30 PaOutdoor unitgfExampleEquivalentpiping lengthRefrigerant piping length170 ma f g h i200 mTotal piping length640 ma b c d e f g h i—Between the first indoor branch and the farthest indoor unit90 m *1f g h i—LevelDifferenceExampleBetween the indoor units15 m *1kBetween the outdoor units and the indoor units50 mj*1.When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoorunits is decreased.Refer to the Engineering Data Book.625955Normal modeConnection ratioQuiet modeMaximum connection ratio is 130%.Connection ratio50%–130%504530 class* The outdoor unit enters power-savingoperation in quiet mode.Easy MaintenanceFrequent oil change is not required.Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation.Connection ratio Total capacity index of the indoor unitsCapacity index of the outdoor unitsOutdoor unit combinationModel name *1GYAQ30ANV1kW85.0Class30Capacityindex750Total capacity index of connectable indoor units *2Combination (%) *250%375100%750130%975Maximum number ofconnectable indoor units48*1.Only single outdoor unit can be connected.*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.* Use the engine oil specified by Daikin.0910

Outdoor Unit LineupHeat Pump – Large Capacity Series 30 classSpecificationsOperation rangeGYAQ30ANV1Power supplyGas1- phase , 230 V , 50 ng colour (Munsell no.)95.0324,00081,700Ivory white(5Y7.5/1)mm2,170Dimensions Widthmm2,100Depthmm800CoolingPowerconsumption HeatingkW1.66kW1.51CoolingFuel gasconsumption ePropeller fanNumber of unitsFans3Motor outputWAirflow ratem3/minDrive570Direct drivemmGasmm31.8Fuel gas pipeinchR3/4Exhaust vent outside dia.mm60.5Drain pipe for exhaust inside dia. 0(Note 1)RANGE FOR CONTINUOUS OPERATION14-10-10460102030OUTDOOR TEMPERATURE ( CDB)405030RANGE FOR CONTINUOUS OPERATION2015-211810-30-20-1001020OUTDOOR TEMPERATURE ( CWB)Note 1: An optional air guard is required.* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.85.0Btu/hkWHeating2530Natural gaskWCooling30Outdoor Unit LineupHeat Pump Large-capacity SeriesModelHeating operationINDOOR TEMPERATURE ( CDB)INDOOR TEMPERATURE ( CWB)Cooling operationkgType19.1Option nameCool/Heat selectorFixing boxREFNET headerDistributivepipingREFNET jointPipe size reducerAntivibration mount *1Air direction adjusterAir guardExhaust extension adaptorExhaust extension external drain filterWater discharge kitExternal contact output harness 6A72TKHRP26A73TKHRP26M73TP , 50H1OSH850J*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.The specified antivibration mount must be used. Otherwise abnormal vibration may occur.*2. Only use of input contact point is possible. Use of output contact point is not possible. (only for 30 class heat pump)151080R-410AChargekgEngine Lubricant Type11.8Yanmar genuine GHP oilEnginecoolantTypeSoundpressure levelNormal modedB(A)Quiet modedB(A)Yanmar genuine LLC (for GHP)Freezing temperaturePiping length;equivalent/actual-35m6259200/170Height difference between O/U is above mindoor and out door units O/U is below m50Height difference between indoor units m15Connectable indoor unitsOptionsnumbercapacity5048%50-130Note:1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m2 Indoor temp.: 20 CDB / outdoor temp.: 7 CDB, 6 CWB/ Equivalent piping length: 7.5 m, level difference: 0 m1112

Outdoor Unit LineupHeat Recovery Series 20/30 classHeat Recovery OperationLarge Capacity & Space Saving DesignSimultaneous heating and cooling operation within refrigerant systemSpace –saving outdoor units allow flexible installation.BS unitIndoor unit(Heating)800 mmIndoor unit(Cooling)1,690 mmHeat radiation operation(all cooling operation)BSUnitHeat radiationcoolingcoolingcoolingIndoor UnitFor example,the heat recovery system canmeet the following needs:2,100 mmFootprint 1.35 m2Heat recovery operation modeOutdoor Unit1040 kg2,170mm800 mmHeat recovery operation!(A)Weight :860 kg2,170mmBy adding suction gas piping and a BSunit (sold separately), simultaneousheating and cooling operation can beprovided by a single system.BS unit30 classseriesWeight :BS unitHigh and low pressure gas pipingSuction gas pipingLiquid pipingOutdoor unit20 classseriesFootprint 1.68 m2The compact outdoor unit can be installed on the balcony of each floor.coolingExternal staticpressure:Heat radiation tendencyheat recovery operation(B)cooling,( mainlypart heating operation )Heat radiationOutdoor Unit LineupHeat Recovery SeriesIn mainly cooling, partly heating mode, the system recycles heat exhausted from the cooling operation to use for heating.In mainly heating, partly cooling mode, the system uses cooled post-heating operation refrigerant for cooling. Efficiencyimproves when simultaneous operation is gCoolingBS unit*1* Allow the specified space for service.A discharge duct may need to beinstalled on the outdoor unit.heatingHeat recovery operation30 PaOutdoor unitOffice building in transition period to winter(cooling and heating operation)The difference between heat generated from the interior zoneand the cool air load in the perimeter zone is large.(C)MaintenancespaceBalcony*1. Field setting is necessary.coolingcoolingheatingheatingHeat absorption tendencyheat recovery operation(D)Heat absorptionCoolingHeatingheating,( mainlypart cooling operation )BS unitcoolingheatingheatingHallwayheatingWide Operating RangeQuiet OperationSystem can operate under a widerange of outdoor temperature.Use of edge technology delivers quietoperations. Enabling the quiet modefurther lowers operating noise levels.Hotel in transition periodHeat absorption operationIndoor units can independently meet the need for coolingand heating.(all heating operation)(E)heatingheatingheatingheatingHeating 11 C18 CCooling 10 C43 CNote: Operation modes (A) and (E) are applicable when the outdoor temperature is 35 C and 7 C respectively;The other modes are applicable under typical outdoor conditions.dB(A) 65605562585955Normal modeQuiet mode50Thanks to the heat recovery system.13* The outdoor unit enters power-savingoperation in silent mode.4520 classAutomatic cooling-heating switchingHeat recovery saves energyThe system automatically switches theoperation mode to cooling or heating based onthe difference between the set temperature andthe indoor temperature. It is not necessary touse the remote controller to switch theoperation mode to cooling or heating.Operation efficiency can befurther increased byrecovering cooling exhaustheat within the same systemand using it effectively asheating energy.30 classEasy MaintenanceHeatingCoolingCooling exhaust heat isrecoveredas heating energy.Frequent oil change is not required.Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation.* Use the engine oil specified by Daikin.14

Outdoor Unit LineupHeat Recovery Series 20/30 classInstallation FlexibilitySpecificationsLong piping lengthThe long piping length provides more design flexibility, which can match even large-sized buildings.Max. actualpiping lengthMax. equivalentpiping length170 m200 m640 mFirst indoor branchMax. level differencebetween the outdoor units and the indoor unitsgfbModelhdcGYEQ20ANPower supplyeGasiNatural gasTypekWCoolingj1Capacity50 ng colour (Munsell no.)Maximumallowablepiping lengthActualpiping lengthExampleRefrigerant piping length170 ma f g h i200 mTotal piping length640 ma b c d e f g h i—f g h i—Between the first indoor branch and the farthest indoor unit90 m*1Equivalentpiping Fuel gasconsumption sorTypeTypePropeller fanNumber of unitsMaximum allowablelevel differenceLevelDifferenceExampleBetween the indoor units15 m*1kBetween the outdoor units and the indoor units50 mjFans50%–130%Connection ratio Total capacity index of the indoor unitsCapacity index of the outdoor units2030Capacityindex500750Total capacity index of connectable indoor units *2Combination (%) *250%250375*1.Only single outdoor unit can be connected.*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.100%500750130%650975Maximum number ofconnectable indoor units324857015.919.128.631.8mm22.228.6Fuel gas pipeinchR3/4R3/4Exhaust vent outside R-410AR-410A11.8Engine Lubricant Type11.8Yanmar genuine GHP oilTypeYanmar genuine LLC (for GHP)Freezing temperature-35Soundpressure level Quiet modedB(A)58dB(A)5559Piping length;equivalent/actualm200/170200/170Height difference between O/U is above mindoor and out door units O/U is below m50505050Height difference between indoor units m1515Connectable indoor unitsNote:15380mmNormal modeoutdoor unit combinationClass370x3mmWeightConnection ratio3370x2Direct driveDischargeEnginecoolant56.085.0m3/minDrain pipe for exhaust inside dia. mmMaximum connection ratio is 130%.GYEQ20ANGYEQ30ANAirflow rateRefrigerant SuctionPipingkWWLiquid1. When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor units isdecreased.Refer to the Engineering Data Book.Model name *1Motor output2DriveConnection ratio81,700Ivory white(5Y7.5/1)Dimensions WidthHeightColours in the diagram above are merely for identifying pipes referenced with symbols such as a .GYEQ30AN1- phase , 200 V , 50 HzOutdoor Unit LineupHeat Recovery SeriesaMax. total piping lengthnumbercapacity%62324850-13050-1301 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m2 Indoor temp.: 20 CDB / outdoor temp.: 7 CDB, 6 CWB/ Equivalent piping length: 7.5 m, level difference: 0 m16

Outdoor Unit LineupHeat Recovery Series 20/30 classBS Unit: SpecificationsOperation rangeHeating operation252010(Note 1)RANGE FOR CONTINUOUS OPERATION14-10-10430102030OUTDOOR TEMPERATURE ( CDB)403030RANGE FOR R TEMPERATURE ( CWB)Note 1: An optional air guard is required.* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.MODELBSGQ100PV1Power supplyTotal capacity index of connectable indoor unitsNo. of connectable indoor unitsOption nameCool/Heat selectorFixing boxGYEQ20ANGYEQ30ANKRC19-26AKJB111AREFNET headerKHRP25M33H (Max. 8 branch)KHRP25M72H (Max. 8 branch)KHRP25M73H (Max. 8 branch)REFNET jointKHRP25A22T,KHRP25A33T(KHRP25A72T KHRP25M72TP)(KHRP25A73T KHRP25M73TP)DistributivepipingAntivibration mount *1Air direction adjusterAir guardExhaust extension adaptorExhaust extension external drain filterWater discharge kitExternal contact output harness20 to 100More than 100 but 160 or lessMore than 160 but 250 or lessMax. 5Max. 8Max. 8CasingGalvanised steel plateDimensions nsIndoor idOutdoormmSuction gasUnitHigh and low pressure gasMachine weightSound levelBSGQ250PV11No. of branchesOutdoor Unit: OptionsBSGQ160PV11-phase, 220-240 V, 50 Hz207x388x 3269.5 (Brazing) 19.5 (Brazing)9.5 (Brazing)15.9 (Brazing) 115.9 (Brazing) 222.2 (Brazing) 39.5 (Brazing)9.5 (Brazing)9.5 (Brazing)15.9 (Brazing)15.9 (Brazing) 222.2 (Brazing) 312.7 (Brazing)12.7 (Brazing) 2kg12.012.0dB(A)42 (32) 443 (32) 4Outdoor Unit LineupHeat Recovery Series30INDOOR TEMPERATURE ( CDB)INDOOR TEMPERATURE ( CWB)Cooling operation19.1 (Brazing) 315.044 (34) 41 When connecting with an indoor unit with a capacity index between 20 and 50, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)2 When connecting with indoor units with total capacity indexes between 150 and 160, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)3 When connecting with indoor units with a capacity index of 200, or with total capacity indexes between 160 and 200, connect the attached pipe to the field pipe.(Braze the connection between the attached and field pipe.)4 Figures in brackets ( ) indicate sound levels when the all indoor units connected to the BS unit are not operating but other indoor units within the same system are operating.HA850HDFB19ERGA850H1OSH850J*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.The specified antivibration mount must be used. Otherwise abnormal vibration may occur.1718

Indoor Unit LineupDaikin’s indoor units are available in 97 models of 17 types to deliver comfortableair conditioning whilst matching the varied requirements of the modern office andresidential building.Ceiling Mounted Duct TypeCeiling Suspended TypeHigh external static pressureallows flexible installationsSlim body with quiet and wideairflowLineupFXFQ-SVMCeiling Mounted Cassette(Round Flow) TypeFXFQ-PVEWall Mounted TypePresence of people and floortemperature can be detected toprovide comfort and energy savingsCeiling Mounted Cassette(Compact Multi Flow) TypeFloor Standing Type360 airflow improves temperaturedistribution and offers acomfortable living environment.4-Way Flow CeilingSuspended TypeConcealed Floor Standing TypeStylish flat panel designharmonised with your interiordécorSuitable for perimeter zone airconditioningIndoor unitsQuiet, compact, and designed foruser comfortCeiling Mounted Cassette(Double Flow) TypeThin, lightweight, and easy to install innarrow ceiling spacesSlim Ceiling Mounted Duct Type(Standard Series)FXDQ-PBVEThis slim and stylish indoor unitachieves optimum air distribution,and can be installed without theneed for ceiling cavity.Middle Static Pressure CeilingMounted Duct TypeFXSQ-PMiddle external static pressureand slim design allow flexible installations192.22.83.64.5FXFQ-SVMFXFQ-PVECeiling Mounted CassetteCorner Type5.67.18911.2141614516.21451802018022.428Slim design for flexible installationSlim Ceiling Mounted Duct Type(Compact Series)FXDQ-SPV1FXDQ-NBVESlim design, quietness andstatic pressure switching(kW)Indoor Unit LineupCeiling Mounted Cassette(Round Flow with Sensing) TypeSlim and compact design for easy andflexible installationSlim CeilingMounted Duct(Standard Series)Slim CeilingMounted Duct(Compact Series)Middle StaticPressure CeilingMounted DuctCeiling g

Outdoor Unit Lineup Heat Recovery Series Indoor Unit Lineup Control Systems Heat pump Air Treatment Equipment Lineup large-capacity series Heat recovery series Heat pump standard series 22.4 kW 8 class 28.0 kW 10 class 35.5 kW 13 class 45.0 kW 16 class 56.0 kW 20 class 71.0 kW 25 class 85.0 kW 30 class Capacity range DAIKIN GAS HEAT PUMP AIR .

Related Documents:

3042f012 dpa pump 3042f022 dpa pump 3042f050 dpa pump 3042f052 dpa pump 3042f062 dpa pump 3042f080 dpa pump 3042f101 dpa pump 3042f102 dpa pump 12 volt 3042f110 dpa pump 3042f150 dpa pump 3042f152 dpa pump 3042f152-r dpa pump 3042f170 dpa pump 3042f171 dpa pump 3042f172 dpa pump 3042f210 dpa pump 3042f212 dpa pump 3042f213 dpa pump 3042f213-r .

Daikin Introduction Course Objectives Daikin introduction and history Daikin as the global leader recognized for energy efficiency, innovation, and high quality products and services Daikin and the environment Target Audience Recommended for anyone Duration 0.5 Hours Class

9w9310 776c, 776d, 777b, 777d 9t6577 pump g gear 9t6813 pump g 9t7414 pump gr 9t7465 pump g 9t7468 pump g 9t8919 pump gp 9t9839 pump g 9t9909 pump g 9w1723 pump g 9w1724 pump g 9w4704 pump g 9w9310 pump g part no. application 07430-72203 d65a, d65e, d65p, d65s, d75a 07436-72202 d135a, d80a, d80e, d80p, d85a, d85c, d85e, d85p, d95s

heat, a heat pump can supply heat to a house even on cold winter days. In fact, air at -18 C contains about 85 percent of the heat it contained at 21 C. An air-source heat pump absorbs heat from the outdoor air in winter and rejects heat into outdoor air in summer. It is the most common type of heat pump found in Canadian homes at this time.

1. Enter the heat pump's AHRI certificate number 2. Click 'Search the list' 3. Review the results. If you see your heat pump, then it meets the cold climate heat pump qualification. If you do not see it, you can reach out to the heat pump's manufacturer for the heat pump's "Submittal sheet". The

Heat Pump Clothes Dryers use heat-pump technology to extract moisture from your clothes. Rather than generating heat with a gas burner or electric coils, a heat pump moves thermal energy from one area to another using a refrigerant and a condenser—like an air conditioner in reverse. As with other heat pump technologies, such

HEAT CHANGE OVER VALVE B C R L2 L1 (HOT) Typical 3H/2C or 2H/1C Heat Pump System System: Indicates current mode of operation. AUXILIARY HEAT RELAY EMERGENCY HEAT RELAY Terminal 2 Heat 2 Cool Conventional System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W/E W2 Transformer power (cooling) Transformer power .

Conduct an API-653 inspection of your tank every five years as recommended by TFI (The Fertilizer Institute) WHAT IS THE API 650 SPECIFICATION API - AMERICAN PETROLEUM INSTITUTE Worldwide Standard for Above Ground Storage Tank Design and Construction Provides requirements for calculations of shell plate thickness, man-way and nozzle design Provides procedures for shell, roof and floor .