FOAM PROPORTIONER EDUCTOR FOR - Primetech Ejectors

1y ago
13 Views
1 Downloads
645.44 KB
5 Pages
Last View : Today
Last Download : 3m ago
Upload by : Samir Mcswain
Transcription

FOAM PROPORTIONER EDUCTOR FOR FIRE FIGHTING - E1300 Series Foam Eductor is a type of foam proportioner that is designed to introduce a foam concentrate into the water streams to produce firefighting foam. These eductors are constant flow devices that produce accurate proportioning of foam concentrate at a specified flow and pressure. Foam eductors are usually portable devices however they can also be used in fixed system applications. PRINCIPLE OF OPERATION Foam Eductor is a device that uses the venturi principle to introduce a proportionate amount of liquid concentrate into a water stream. The venturi is the constricted portion of the waterway near the Eductor inlet. This restricted passage increases water velocity, thus momentarily reducing its pressure as it passes into the larger area of the induction chamber. Concentrate is introduced into this reduced pressure area through a metering device. The venturi orifice performs as a very efficient straight bore nozzle that is calibrated for a given flow at a given pressure. The foam coming out of the discharge device is called the finished fire -fighting foam. Finished foam is a combination of water, foam concentrate, air and mechanical agitation. The foam concentrate varies in the finished fire- fighting foam as :he Ballast pump FOAM TYPES Fluroprotein Aqueous Film Forming Foam (AFFF) Alcohol Resistant Foam FOAM CONCENTRATES 1% 3% 6% WATER PERCENTAGE 99 97 94 o Fluroprotein foam which is the most commonly used, a 3% setting is generally followed. DESIGN ASPECTS Foam proportioning eductors require inlet pressures in the range of 10-14 Bar (150-200 PSI) to meet the functional requirement and to overcome the system frictional loss and foam monitor head loss. Optimum pressure of the above range has to be selected because higher pressures will cause foam quality to deteriorate while the lower pressures will reduce the reach of foam streams. The eductor has to be selected after considering the limitation of permissible back pressure. A maximum back pressure of 50% of the inlet pressure may be considered. In fixed system, the eductor can be mounted above the foam concentrate tank. In this case, one should ensure that the eductor is mounted at a maximum of 2.4-3 m (8-10 ft ) above the bottom of the foam liquid storage container. The metering device or valve can be adjusted to vary the foam concentrate in the finished fire fighting foam.

Application Foam Eductors are mainly used by municipal or airport fire departments where rapid, simple and cost effective deployment of a foam proportioning device is required. These eductors are also capable of generating and discharging fire extinguishing foam to a deck of the ship where fire is most likely to take place. Refineries Chemical Plants Loading docks Tanker Berths Railroad yards Offshore platforms ADVANTAGES Self -priming No moving parts Easy to install Simple & reliable Easy to maintain Safe Low Cost MATERIAL OF CONSTRUCTION SL.NO. 1 2 DESCRIPTION BODY, DIFFUSER & NOZZLE ORIFICE Type - 1 Aluminiuma alloy IS : 617 Bronze IS:318, LTB-II Type - 2 Bronze IS:318, LTBII Bronze IS:318, LTBII Type - 3 SS304 ASTM A351-CFB SS304 ASTM A351-CFB WE CAN ALSO OFFER IN THE FOLLOWING MATERIALS SS316 MILD STEEL END CONNECTIONS Flanged to ANSI B16.5 150# as a standard. We can also provide other standard and end connection as required.

HD TYPICAL ENQUIRY DATA MONITOR INLET PRESSURE INLET PRESSURE EJECTOR BACK PRESSURE L FLOW CONTROLLING ORIFICE CHECK VALVE HS FOAM CONCENTRATE SHUT-OFF VALVE 2.4 mtr (Max) FOAM EJECTOR BUILDING ATMOSPHERIC STORAGE TANK (FOAM CONCENTRATE) DATA TO BE FILLED BY THE CUSTOMER VALUE UNIT ³ ³ ³ ³ .

FIRE FIGHTING - E1300 Series Foam Eductor is a type of foam proportioner that is designed to introduce a foam concentrate into the water streams to produce firefighting foam. These eductors are constant flow devices that produce accurate proportioning of foam concentrate at a specified flow and pressure. Foam eductors are usually portable .

Related Documents:

1995-Present CULLIGAN MARK 10 Eductor Assembly 1990-Present AQUA-CLEER FAUCET Stem Assembly, Spout 2 Cat. No. 00-2267-00 0.25 I.D. x 0.375 O.D. x 0.062 EPT 1960-1961 CULLIGAN MARK 4 Eductor Throat (All) 1962-1964 CULLIGAN MARK 5 Eductor Throat (All) 1965-1982 CULLIGAN MARK

will provide more effective mixing than one centrally located eductor 6. Determine eductor placement Little agitation occurs below the level of the eductor, so eductors should be positioned as close as possible to the bottom of the tank for maximum liquid turnover If settling cannot be tolerated, install the eductors

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

2. How has the Floral Foam (Phenolic Foam) with Resin Manufacturing industry performed so far and how will it perform in the coming years ? 3. What is the Project Feasibility of a Floral Foam (Phenolic Foam) with Resin Manufacturing Plant ? 4. What are the requirements of Working Capital for setting up a Floral Foam with Resin Manufacturing

Non-Fire Fighting Products PAGE 10 Foam Compatibility PAGE 11 Foam Standards PAGE 12 Why is Foam Testing Required? PAGE 14 Foam Test Reports PAGE 15 How to Take Foam Samples PAGE 16 Foam Test Kits PAGE 18 Foam Testing Equipment & Training PAGE 20 Environmental Issues PAGE 21 www.firefightingfoam.com.

Operation PLURAL COMPONENT PROPORTIONER A-25/A-XP1 Air operated, electrically heated, plural component proportioner A-25: For spraying or dispensing 1:1 ratio polyurethane foam formulations and other 1:1 fast setting materials. A-XP1: For spraying or dispensing 1:1 ratio polyurea formulations and other 1:1 fast setting materials.

systems. The amount of foam concentrate fed to the foam proportioner of a firefighting system is critical, not only in the making of foam with the proper expansion and drainage rate, but also in making a fire-resistant foam. Therefore, it is essential that correct proportioning is maintained and that the concentration meets the required level.

Soldier’s level of functioning as of the last developmental counseling session IAW AR 380-5, paragraph 5-5; and AR 25-2, paragraph 4-5. 2. First line leaders should: a. Conduct counseling sessions addressing the domains identified on the USA SLRRT with all Soldiers for whom they are responsible IAW paragraph F: Policies and