Eagle Talon RetroFit Double-Hung And Picture Window Measuring Guidelines

11m ago
7 Views
1 Downloads
544.99 KB
5 Pages
Last View : 21d ago
Last Download : 3m ago
Upload by : Adele Mcdaniel
Transcription

Eagle Talon RetroFit Double-Hung and Picture Window Measuring Guidelines To assist you with measuring for Eagle Talon RetroFit products, we’ve included typical section details of double-hung products comparable to what may be in your home. Please read these guidelines completely before starting. For questions about this and other Eagle products, see your nearest Eagle Window & Door dealer or visit us online at EagleWindow.com. Consult your local building code official for applicable building codes and regulations. Thank you for choosing Eagle products. TYPICAL DOUBLE-HUNG WINDOWS Exterior Horizontal Section Interior casing Interior Interior stop Side jamb Bottom sash Interior casing Exterior casing Exterior blind stop Glass Exterior blind stop Exterior casing Head jamb Interior stop Glass Parting stop Bottom sash Top sash Parting stop Exterior Interior Vertical Section Glass Stool Top sash Sill Apron TYPICAL DOUBLE-HUNG PICTURE WINDOWS Exterior Interior casing Interior Interior Vertical Section Horizontal Section Interior stop Side jamb Interior casing Exterior casing Exterior blind stop Glass Head jamb Interior stop Glass Exterior Exterior blind stop Exterior casing Sash Stool Sash Sill Apron TOOLS REQUIRED Tape measure Angle finder Thin ruler 800.324.5354 EagleWindow.com

INSPECT THE OLD WINDOW Carefully inspect the existing window openings prior to measuring and ordering your RetroFit windows. STEP 2 Check the existing opening for plumb level and square. A unit is square when the diagonal measurements are within 1/8". If a unit is not plumb, level and square, adjust the opening accordingly. Double-Hung Double-Hung Picture STEP 1 Check the existing window frame for damage. Deteriorated or rotted wood members, including the exterior blind stops must be repaired prior to installation. Tape measure Tape measure If the original window frame cannot be repaired or replaced, the opening will not be suitable for a RetroFit window replacement. Interior Interior STEP 3 STEP 4 Measure the exterior blind stop on the existing frame. If the measurement is greater than 1/2", the blind stop will have to be modified or the unit will need to be installed from the exterior. Measure frame to make sure that a 3-1/4" wide pocket exists or can be created for the RetroFit window. Double-Hung Picture Double-Hung Double-Hung Interior Interior Interior 3-1/4" No more than 1/2" No more than 1/2" Exterior Double-Hung Picture Exterior Exterior Pocket Interior Exterior blind stop Talon RetroFit Double-Hung and Double-Hung Picture Window Measuring Guidelines Exterior blind stop Page 2 3-1/4" Exterior Pocket 800.324.5354 EagleWindow.com

MEASURING THE OPENING Measure each window even if they appear to be the same size. Use extreme accuracy when taking measurements. Record all measurements on the “Measurement Worksheet”, located on the last page of this document. You will be required to calculate the unit “make size” after the opening measurements have been determined. STEP 1 Measure the inside opening width (side jamb to side jamb) at three locations: top, center and bottom. Record the smallest measurement on the worksheet provided. Double-Hung Tape measure Side jamb Side jamb Interior Inside opening width Exterior Interior Measure from wood side jamb to wood side jamb. Lower sash is not shown for the purpose of illustrating the measuring location. Double-Hung Picture Tape measure Side jamb Side jamb Interior Inside opening width Exterior Interior Measure from wood side jamb to wood side jamb. Talon RetroFit Double-Hung and Double-Hung Picture Window Measuring Guidelines Page 3 800.324.5354 EagleWindow.com

MEASURING THE OPENING (CONT’D) STEP 2 Measure the inside opening height (top of sill, just behind the stool, to the underside of the head jamb) at three locations: left, center and right. Record the smallest measurement on the worksheet provided. Double-Hung Double-Hung Picture Tape measure Tape measure Sill Head jamb Inside opening height Head jamb Interior Exterior Inside opening height Interior Exterior A Stool Sill Interior B Stool Interior Note: Measure directly behind stool. Measure from wood head jamb to top of stool (A). Measure from head jamb to top of sill. Slide a thin ruler behind stool (cut paint if needed) to measure stool height (B). Thin ruler Height A B STEP 3 STEP 4 STEP 5 Measure the angle of the existing sill using an angle finder. Record the angle to the nearest degree on the worksheet provided. Calculate the unit “make” width from the inside opening width dimension taken earlier. Unit make width (inside opening width - 1/4"). Then round down to the nearest 1/4" increment and record on the worksheet. Calculate the unit “make” height from the inside opening height dimension taken earlier. Unit make height (inside opening height - 1/4"). Then round down to the nearest 1/4" increment and record on the worksheet. Example: Example: Angle finder Sill Talon RetroFit Double-Hung and Double-Hung Picture Window Measuring Guidelines 36-1/8" minus 1/4" 35-7/8" 45-7/8" minus 1/4" 45-5/8" Then round down to the nearest 1/4" increment, or 35-3/4". Then round down to the nearest 1/4" increment, or 45-1/2". Page 4 800.324.5354 EagleWindow.com

MEASURING THE OPENING (CONT’D) Measurement Worksheet Note: Eagle Window & Door only accepts unit “make size” measurements. It remains the customer’s responsibility to subtract from the inside opening dimensions to get the unit make size. STEP 1 STEP 2 STEP 3 Existing Window Opening STEP 4 STEP 5 RetroFit Inside Frame Size Quantity Window/Location Width Height Sill Angle Make Width Make Height 1 Example 36-1/8" 45-7/8" 10 35-3/4" 45-1/2" Project Name: Measured By: Date: “Eagle” and all other marks denoted are trademarks of Eagle Window & Door Manufacturing, Inc. 2009 Eagle Window & Door Manufacturing, Inc. All rights reserved. Talon RetroFit Double-Hung and Double-Hung Picture Window Measuring Guidelines Page 5 800.324.5354 EagleWindow.com

Quantity Window/Location Width Height Sill Angle RetroFit Inside Frame Size 1 Example 36-1/8" 45-7/8" 10 35-3/4" 45-1/2" Make Width Make Height 800.324.5354 EagleWindow.com Talon RetroFit Double-Hung and Double-Hung Picture Window Measuring Guidelines MEASURING THE OPENING (CONT'D) Project Name: Measured By: Date:

Related Documents:

Eagle II, Golden Eagle II, & Directional Golden Eagle II (Eagle 3 has Yr 3 included): 3rd Year Warranty (444-0002-03) 1 Each 30 days 227.00 39 Kustom Signals, Inc. Eagle II, Golden Eagle II, Directional Golden Eagle II & Eagle 3: 4th Year Warranty (444-0002-04) 1 Each 30 days 252.00 40 Kustom Signals, Inc. Eagle II, Golden Eagle II .

Rain Bird Part Number: For Eagle 900/950 — Part #D02203, Model: SRP For Eagle 700/750, 500/550 — Part #D02236, Model: SR-700 4. Selector valve key — used to manually operate and service electric Eagle Rotors. Rain Bird Part Number: For Eagle 900/950, 700/750, 500/550 — Part #B41720, Model: EGL-SVK

April 2017 Ultimate Double Hung G2 4/24/2017 Introduction of the Ultimate Double Hung G2. enhanced locking system. Features include a centralized locking point at the check rail, a complete metal drive locking system and an updated jamb receiver assembly to assist with installation. Present December 2017

Window Parts Reference Catalog (Includes Parts and Information for Double Hung Tilt Oriel and Double Hung Tilt Picture) Weather Shield Mfg., Inc. Medford, WI 54451z715/748-2100 #010636 (Revised 01/03) Double Hung Tilt Window Table of Contents

66 21 2 359 135 BMW Advanced Car Eye retrofit kit (front and rear camera) 66 21 2 359 136 BMW Advanced Car Eye retrofit kit (front camera) 66 21 2 364 600 BMW Advanced Car Eye retrofit kit (front and rear camera) 66 21 2 364 601 BMW Advanced Car Eye retrofit kit (front camera) 66 21 2 288 543 BMW Advanced Car Eye retrofit kit (front and rear .

If you have any questions concerning the Retrofit Kit and / or the Retrofit process, contact Cutler-Hammer at 1-800-937-5487. Work Sequence Figure 1 illustrates the general work sequence for all DS Breaker Retrofit Kits. The available Retrofit Kits are listed across the top of the figure. Under each kit, the components

4 FI9 retrofit kit installation 2. FI9 RETROFIT KIT INSTALLATION 2.1 Retrofit kit contents Figure 1. FI9 DC fan retrofit kit contents Table 2. FI9 DC fan retrofit assembly kit (SPR-MEC23728) part list # Item number Item description Pcs 1 70CPA00556 DC main fan assembly 1 2 70CMC05006 External DC fan supply assembly 1 3 70CPA03288 Asic cover and .

DEFINISI INVESTASI Investasi adalah komitmen atas sejumlah dana atau sumberdaya lainnya yang dilakukan pada saat ini, dengan tujuan memperoleh sejumlah