U-blox LISA-C200 And FW75-C200

3m ago
24 Views
1 Downloads
4.15 MB
149 Pages
Last View : 16d ago
Last Download : 3m ago
Upload by : Mara Blakely
Transcription

LISA-C200 and FW75-C200 CDMA 1XRTT Cellular Modules AT Commands Manual Abstract Description of standard and proprietary AT Commands used with u-blox LISA-C200 and FW75-C200 cellular modules. These modules are complete and cost efficient CDMA solutions offering 153 kb/s data speed dual-band 800/1900 MHz data transmission technology in compact form factors. www.u-blox.com UBX-13000621 - R10

LISA-C200 and FW75-C200 - AT Commands Manual Document Information Title LISA-C200 and FW75-C200 Subtitle CDMA 1XRTT Cellular Modules Document type AT Commands Manual Document number UBX-13000621 Revision and date R10 Document status Production Information 01-Oct-2014 Document status explanation Objective Specification Document contains target values. Revised and supplementary data will be published later. Advance Information Document contains data based on early testing. Revised and supplementary data will be published later. Early Production Information Document contains data from product verification. Revised and supplementary data may be published later. Production Information Document contains the final product specification. This document applies to the following products: Name Type number Firmware version PCN reference FW75-C200 LISA-C200 FW75-C200-02S-00 LISA-C200-02S-00 E0.S.04.00.03R E0.S.04.00.03R UBX-TN-12070 UBX-TN-12070 FW75-C200 LISA-C200 FW75-C200-22S-00 LISA-C200-22S-00 E0.V.04.00.03R E0.V.04.00.03R UBX-TN-12070 UBX-TN-12070 FW75-C200 FW75-C200-02S-01 E0.S.05.00.04R UBX-TN-12077 LISA-C200 FW75-C200 LISA-C200-02S-01 FW75-C200-22S-01 E0.S.05.00.04R E0.V.05.00.02R UBX-TN-12077 UBX-TN-12077 LISA-C200 LISA-C200 LISA-C200-22S-01 LISA-C200-03S-00 E0.V.05.00.03R E0.S.06.00.07R UBX-TN-12077 UBX-13005454 LISA-C200 LISA-C200 LISA-C200-23S-00 LISA-C200-04S-00 E0.V.06.00.06R E0.S.07.00.07R UBX-13005454 UBX-14042040 LISA-C200 LISA-C200-24S-00 E0.V.07.00.07R UBX-14042040 u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com. Copyright 2014, u-blox AG. u-blox is a registered trademark of u-blox Holding AG in the EU and other countries. ARM is the registered trademark of ARM Limited in the EU and other countries. UBX-13000621 - R10 Page 2 of 149

LISA-C200 and FW75-C200 - AT Commands Manual Preface u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the supported AT commands by cellular modules to verify all implemented functionalities. System Integration Manual: This Manual provides hardware design instructions and information on how to set up production and final product tests. How to use this Manual This AT Commands Manual provides the necessary information to successfully design in and configure these u-blox cellular modules. For navigating this document, note the following: This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual: An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. Questions If you have any questions about u-blox cellular hardware integration: Read this manual carefully. Contact our information service on our homepage http://www.u-blox.com Read the questions and answers on our FAQ database Technical Support Worldwide Web Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and helpful FAQ can be accessed 24h a day. By E-mail If you have technical problems or cannot find the required information in the provided documents, contact the nearest Technical Support office by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support, have the following information ready: Module type (e.g. LISA-C200-04S-00) and firmware version (e.g. E0.S.07.00.07R) Module configuration Clear description of your question or the problem A short description of the application Your complete contact details UBX-13000621 - R10 Production Information Preface Page 3 of 149

LISA-C200 and FW75-C200 - AT Commands Manual Content Preface . 3 Content . 4 1 2 Introduction . 10 1.1 Purpose . 10 1.2 Definitions . 10 1.3 AT commands mode. 10 IPC – Inter Processor Communication. 12 2.1 3 4 Multiplexing mode CMUX . 12 General commands. 13 3.1 Device Information ATI . 13 3.2 Request Manufacturer Identification GMI . 13 3.3 3.4 Request model identification GMM . 14 Request revision identification GMR . 14 3.5 Request product serial number identification GSN . 14 3.6 3.7 Request international mobile subscriber identification CIMI . 15 DTE-DCE local flow control IFC . 15 3.8 Set the DTE Rate IPR . 16 3.9 3.10 Set the Rm interface protocol CRM . 16 Read the PRL ID PRL . 17 3.11 Read/write the current MDN MDN . 17 3.12 3.13 Read/write the current MSID MSID . 17 Set the Echo ON/OFF E . 18 3.14 Set the Result Code Suppression ON/OFF Q . 18 3.15 3.16 Response Format V . 18 HW version UHWVER . 19 3.17 Returns Temperature UTEMP . 19 3.18 3.19 Antenna detection AT UANTR. 19 Set up Aeris PRI (special RTN for Aeris) UAERIS . 20 3.20 Update ACCOLC UPACCOLC . 21 3.21 Set up US Cellular PRI (special RTN for US Cellular) UUSCELL . 21 Mobile equipment control and status commands . 23 4.1 4.2 Phone activity status CPAS . 23 Switch off MT CPWROFF . 23 4.3 Device reset command RTN . 24 4.4 4.5 Set phone functionality CFUN . 24 Power Saving control UPSV . 24 UBX-13000621 - R10 Production Information Content Page 4 of 149

LISA-C200 and FW75-C200 - AT Commands Manual 5 6 7 4.6 4.7 Indicator control CIND . 26 Clock CCLK . 27 4.8 Mobile termination event reporting CMER. 27 4.9 4.10 Report mobile termination error CMEE . 28 Reset to factory default without resetting NAM (special RTN) UCLEAN . 29 4.11 Provision State UPROVSTATE . 29 Call control commands. 30 5.1 Dial command D . 30 5.2 Call answer A . 30 5.3 5.4 Dial voice call CDV. 30 Hang Up voice call CHV . 31 5.5 Hang up call CHUP . 31 5.6 5.7 Call status messages UCST . 31 Extended error report CEER . 32 5.8 Tone Duration VTD . 32 5.9 5.10 DTMF and tone generation VTS . 33 Configure Ring Indicator URINGCFG . 33 5.11 Configure Call precedence during socket operations USORNGCFG . 34 5.12 Read call status UCSTRD . 34 Network service commands . 35 6.1 6.2 Network Service information USVC . 35 Signal quality CSQ . 35 6.3 Network registration and roaming information CREG . 36 6.4 6.5 Return the debugging information DEBUG . 37 CDMA network parameters NETPAR . 37 6.6 To display protocol revision in use QCPREV . 38 6.7 6.8 Um Packet Data Inactivity Timer CTA . 38 System information CSS . 39 6.9 Query Analog or Digital Service CAD . 39 1XRTT Data commands . 40 7.1 Mobile Station IP Address CMIP . 40 7.2 Base Station IP Address CBIP . 40 7.3 7.4 Request overall capabilities GCAP . 40 Enable/disable Mobile IP functionality QCMIP . 40 7.5 Set the active Mobile Profile ID QCMIPP. 41 7.6 7.7 Enable/disable the RFC2002bis Authentication QCMIPT. 41 Enable/disable the active profile QCMIPEP . 42 7.8 Display information to Specific Profile QCMIPGETP . 42 7.9 7.10 Set NAI for active profile QCMIPNAI . 43 Set the reverse tunneling on currently active profile QCMIPRT . 43 7.11 Set MN-AAA Shared Secrets QCMIPMASS . 44 7.12 Set MN-AAA Shared Secrets in HEX format QCMIPMASSX . 45 UBX-13000621 - R10 Production Information Content Page 5 of 149

LISA-C200 and FW75-C200 - AT Commands Manual 8 7.13 7.14 Set MN-HA Shared Secrets QCMIPMHSS . 45 Set MN-HA Shared Secrets in Hex format QCMIPMHSSX . 46 7.15 Set MN-HA SPI Shared Secrets QCMIPMHSPI . 46 7.16 7.17 Set MN-AAA SPI Shared Secrets QCMIPMASPI . 47 MIP Indicator CMIPIND . 47 Short Messages Service commands . 49 8.1 8.2 Show text mode parameters CSDH. 49 New message indication CNMI . 49 8.3 List message CMGL . 50 8.4 8.5 Read message CMGR . 51 Send message CMGS . 53 8.6 Set text mode parameters CSMP . 53 8.7 8.8 Delete SMS CMGD . 54 Unsolicited Response (new SMS-DELIVER receipt indication) CMTI . 55 8.9 Write Message to Memory CMGW. 55 8.10 9 Send Message from Storage CMSS . 55 Supplementary services commands . 57 9.1 Calling line identification presentation CLIP . 57 10 Sprint OMA-DM provisioning commands . 58 10.1 Enable/ Disable OMA-DM capabilities OMADM . 58 10.2 10.3 Enable/ Disable PRL provisioning PRL . 58 Enable/ Disable FUMO provisioning FUMO . 59 10.4 HFA Session Enable/Disable UOMAHFA . 59 10.5 10.6 Session Cancel UOMADM . 60 Enable / Disable OMADM/FUMO unsolicited status messages UOMASTAT . 60 10.7 Roaming status ROAM . 61 10.8 10.9 Device reset command RTN. 61 Device power cycle command RESET . 61 10.10 Check data service command SERVICE. 62 10.11 10.12 Set IMSI Data UIMSIDATA . 62 Set call termination enabled indicators UMOBTERM . 63 10.13 Set Home SID/NID pair USIDNIDPR . 63 10.14 Write PRL file UPRLWRITE . 64 11 Verizon OTA Provisioning commands. 66 11.1 Initiate OTA Provisioning ( CDV *22899). 66 11.2 OTA Provisioning Activation Indicator ( UACTIND) . 66 12 GPIO AT-commands. 67 12.1 Introduction . 67 12.2 12.3 LISA-C200 GPIO mapping . 67 GPIO select configuration command UGPIOC . 67 12.4 GPIO read command UGPIOR . 68 UBX-13000621 - R10 Production Information Content Page 6 of 149

LISA-C200 and FW75-C200 - AT Commands Manual 12.5 GPIO set command UGPIOW . 69 13 Audio. 70 13.1 Introduction . 70 13.2 13.3 Microphone Gain (Microphone Gain Control) UMGC . 70 Speaker Gain (Speaker Gain Control) USGC . 71 13.4 Sidetone (SideTone) USTN . 72 13.5 13.6 Uplink Digital Filter UUBF . 73 Downlink Digital Filters UDBF . 74 13.7 Hands-Free Parameters UHFP . 74 13.8 13.9 Audio Path mode setting (Set Path Mode) USPM . 77 PCM Digital Interface Setup UPCM . 77 13.10 Play audio file UPLAYFILE . 78 13.11 Stop audio file USTOPFILE . 79 14 TCP/IP UDP/IP . 80 14.1 14.2 Introduction . 80 Packet Switched Data Action Configuration UPSDACFG . 80 14.3 Packet Switched Data Action UPSDA . 81 14.4 14.5 Create Socket USOCR . 81 Set Socket Option USOSO . 82 14.6 Get Socket Option USOGO . 83 14.7 14.8 Close Socket USOCL . 83 Get Socket Error USOER . 84 14.9 Connect Socket USOCO . 84 14.10 14.11 Write Socket Data USOWR . 85 Socket Connection Timeout Control USOABT . 86 14.12 Send To command USOST (UDP only) . 86 14.13 14.14 Read Socket Data USORD . 88 Receive From command USORF (UDP only) . 89 14.15 Set Listening Socket USOLI . 90 14.16 14.17 Set socket in Direct Link mode USODL . 91 Socket Control USOCTL . 92 14.18 Configure Maximum Segment Size UMSS . 93 15 DNS. 94 15.1 Resolve Name / IP Number through DNS UDNSRN . 94 16 File system AT Commands . 95 16.1 16.2 Download File UDWNFILE . 95 Delete File UDELFILE . 95 16.3 Read File URDFILE . 96 16.4 List Files Information ULSTFILE . 96 17 FTP . 98 17.1 FTP Control UFTP . 98 UBX-13000621 - R10 Production Information Content Page 7 of 149

LISA-C200 and FW75-C200 - AT Commands Manual 17.2 17.3 FTP Command UFTPC . 99 FTP Unsolicited Data URC UUFTPCD. 101 17.4 FTP Command Result URC UUFTPCR. 102 17.5 FTP Error UFTPER. 102 18 HTTP . 103 18.1 HTTP Control UHTTP . 103 18.2 18.3 HTTP Command UHTTPC . 104 HTTP Command Result URC UUHTTPCR . 105 18.4 HTTP Protocol Error UHTTPER. 106 19 GNSS. 107 19.1 GNSS Power Management UGPS . 107 19.2 19.3 Assisted GNSS unsolicited indication UGIND . 109 GNSS Profile configuration UGPRF . 110 19.4 AssistNow Online configuration UGAOP . 111 19.5 19.6 AssistNow Offline configuration UGAOF . 1

LISA-C200 and FW75-C200 - AT Commands Manual UBX-13000621 - R10 Production Information Preface Page 3 of 149 Preface u-blox Technical Documentation . As part of our commitment to customer support, ublox maintains an extensive volume of technical - documentation for our products. In addition to our product-specific technical data sheets, the .

Related Documents:

LISA-C200 & FW75-C200 CDMA 1xRTT Wireless Modules System Integration Manual Abstract This document describes the features and the integration of u-blox LISA-C200 and FW75-C200 CDMA2000 1xRTT wireless modules. These modules are complete and cost efficient CDMA solutions offering 153 kb/s data speed dual-band 800/1900 MHz data

u-blox 8 / u-blox M8 Receiver Description - Manual Document Information Title u-blox 8 / u-blox M8 Receiver Description Subtitle Including Protocol Specification v15-20.30,22-23.01 Document type Manual Document number UBX-13003221 Revision and date R17 (5321fe3) 17 May 2019 Document status

u-blox 8 / u-blox M8 Receiver Description - Manual Document Information Title u-blox 8 / u-blox M8 Receiver Description Subtitle Including Protocol Specification v15-20.30,22-23.01 Document type Manual Document number UBX-13003221 Revision and date R12 (c9f0122) 28 April 2017 Document status

u-blox 8 / u-blox M8 Receiver Description - Manual Document Information Title u-blox 8 / u-blox M8 Receiver Description Subtitle Including Protocol Specification v15-20.30,22-23.01 Document type Manual Document number UBX-13003221 Revision and date R16 (e581faf) 18 December 2018 Document status

To determine which u-blox product best meets your needs, see the product selector tables on the u-blox website www.u-blox.com. 1.2 Configuration The configuration settings can be modified using UBX protocol configuration messages; see the u-blox 8 / u-blox M8 Receiver Description Includ

u-blox AG Zürcherstrasse 68 8800 Thalwil Switzerland www.u-blox.com Phone 41 44 722 7444 Fax 41 44 722 7447 info@u-blox.com u-blox 5 NMEA, UBX Protocol Specification u

FW75 and C200 CDMA 1xRTT Wireless Modules System Integration Manual Abstract This document describes the features and the integration of u-blox LISA-C200 and FW75 CDMA2000 1xRTT wireless modules. These modules are complete and cost efficient CDMA solutions offering 153 kb/s data speed dual-band 800/1900

the Ethics of Artificial Intelligence, the findings and recommendations of the Dialogue will provide the stakeholders with the opportunity to reflect on how best to integrate gender equality considerations into such global normative frameworks. This report is the result of teamwork. First, I am grateful to the experts and leaders in the field of AI for taking the time to either talk to me via .