ANALOG-ADDRESSABLE FIRE ALARM CONTROL PANEL,

2y ago
55 Views
5 Downloads
3.59 MB
28 Pages
Last View : 3d ago
Last Download : 3m ago
Upload by : Genevieve Webb
Transcription

EN 54-2User’smanualEN 54-4EN 54-21EN SABLE FIRE ALARM CONTROL PANEL,EXTINGUISHANT SYSTEM CONTROL PANEL,ALARM TRANSMISSION AND FAULT WARNING ROUTING EQUIPMENTUSER’S MANUAL1

Fire detection and extinguishant systemWarrantyINIM Electronics s.r.l. (Seller, Our, Us) warrants the original purchaser that this product shall be free from defects inmaterials and workmanship under normal use for a period of 24 months. As INIM Electronics s.r.l. does not install thisproduct directly, and due to the possibility that it may be used with other equipment not approved by Us; INIMElectronics s.r.l. does not warrant against loss of quality, degradation of performance of this product or actual damagethat results from the use of products, parts or other replaceable items (such as consumables) that are neither made norrecommended by INIM Electronics. Seller obligation and liability under this warranty is expressly limited to repairing orreplacing, at Seller's option, any product not meeting the specifications. In no event shall INIM Electronics s.r.l. be liableto the purchaser or any other person for any loss or damage whether direct of indirect or consequential or incidental,including without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defectiveproducts or otherwise arising from the incorrect or otherwise improper installation or use of this product.This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover: damage arising from improper maintenance or negligencedamage caused by fire, flood, wind or lightningvandalismfair wear and tearIINIM Electronics s.r.l. shall, at its option, repair or replace any defective products. Improper use, that is, use for purposesother than those mentioned in this manual will void the warranty. Contact Our authorized dealer, or visit our website forfurther information regarding this warranty.Limited warrantyINIM Electronics s.r.l. shall not be liable to the purchaser or any other person for damage arising from improper storage,handling or use of this product.Installation of this Product must be carried out by qualified persons appointed by INIM Electronics. Installation of thisProduct must be carried out in accordance with Our instructions in the product manual.CopyrightThe information contained in this document is the sole property of INIM Electronics s.r.l.No part may be copied without written authorization from INIM Electronics s.r.l.All rights reserved.2Warranty

User’s manualTable of contentsWarranty. 2Limited warranty. 2Copyright. 2Table of contents . 3General information . 5Chapter 11.11.21.31.4Manufacturer's details .5About this manual .5Operator qualifications - access levels .5CE Mark.6Chapter 2Chapter 33.13.23.33.4Operative statuses of the Previdia Compact system .8User interface .9Front plate models.9Function buttons and LEDs .10Screen in standby status. 11Status Bar. 12Chapter 44.14.2Inim Cloud Fire . 14User interface, home page .14Registration of a control panel to the Inim Cloud user account . 15Chapter 55.15.25.3Viewing the system. 16Viewing active events.16Visualization of the events log . 17Visualization of the system status .18Chapter 66.16.26.36.4Using the system .22Access to programming. 22Device management. 22Management of the remote communicator . 23Managing the extinction channel . 24AppendixTable of contentsRapid emergency management .273

Fire detection and extinguishant system4Table of contents

User’s manualChapter 1General information1.1Manufacturer's detailsManufacturer: INIM ELECTRONICS S.R.L.Production plant: Centobuchi, via Dei Lavoratori 10Municipality: 63076, Monteprandone (AP), ItalyTel.: 39 0735 705007Fax: 39 0735 704912E-mail: info@inim.bizWeb: www.inim.bizThe personnel authorized by the manufacturer to repair or replace the components of this system have authorization towork only on devices marketed under the INIM Electronics brand.1.2About this manualManual code: DCMUINE0PREVIDIACRevision: 1.10This manual describes the procedures for the configuration, commissioning and maintenance of the Previdia Compactfire-detection system.1.3Operator qualifications - access levelsThe control panel has 4 distinct access levels:Level 1: Public level - this is the normal access level of the control panel and is the access level for building inhabitantswho are neither authorized to use the system nor instructed in its use.At this level it is possible to display the information on the display and on the signalling LEDs, interact using the buttonsand touch screen to scroll through the information. Level 1 allows the following operations only: mute buzzer test signalling LEDs activate alarm signalling when an early-warning process is runningLevel 2: Authorized users - this access level is for the system supervisors and is for authorized personnel who areadequately instructed in the use of the system and its functions.Access requires the use of a key or entry of a valid access code with sufficient access rights. In addition to the operationsdescribed for level 1 it is also possible to carry out the following operations: mute alarm signalling devicesrearm the control panelactivate alarm signalling devices manuallydisable control panel elementsplace in test status one or more of the system elementsThe system provides two additional sub-levels of authorized user:- Superuser level, like the previous one, with the added possibility of replacing a loop device and registering controlpanels to the Inim Cloud service account- Maintenance operator level, same as the previous level with the added possibility of stopping the valve pulse forthose models that support extinction functionsLevel 3: Programming - this access level is for specialized technical operators who carry out system configuration,commissioning and maintenance.General information5

Fire detection and extinguishant systemAccess requires entry of a valid access code with sufficient access rights after inserting a jumper which enablesprogramming. Refer to the manual for system configuration, commissioning and maintenance.ONLY authorized technicians, appointed by the Manufacturer can, by means of special tools, carry out repair work onthe motherboard.Level 4: ONLY authorized technicians, appointed by the Manufacturer can, by means of special tools, carry out repairwork on the motherboard.1.4CE Mark1.4.1 Regulation (EU) No. 305/2011This product complies with requirements stated by standards listed here below in compliance with Regulation (EU) No.305/2011.Essential features0051INIM Electronics s.r.l.Via Dei Lavoratori 10 - Fraz. Centobuchi63076, Monteprandone (AP) - Italy180051-CPR-1498EN 54-2:1997 A1:2006EN 54-4:1997 A1:2002 A2:2006EN 54-21:2006EN 12094-1:2003PREVIDIA-C200LG, PREVIDIA-C200LR, PREVIDIA-C200LZG,PREVIDIA-C200LZR, PREVIDIA-C200LZEG, PREVIDIA-C200LZERControl and indicating equipment with power supply equipment, alarmtransmission and fault warning routing equipment and electrical automaticcontrol and delay device integrated for fire detection and fire alarm systemsinstalled in buildings and for gas extinguishing systems installed inbuildings and part of a complete system.Performance in the event of firePower supply performanceResponse delay (response time in the event of fire)Transmission performanceOperating reliabilityThermal resistanceVibration resistanceDurability ofoperating reliability:Humidity resistanceElectrical stabilityOptions provided in accordance with EN54-27.8 Output to fire alarm devices7.9 Output to fire alarm routing equipment7.10 Output to fire protection equipment7.11 Delay on outputs7.12 Co-incidence detection (Type A, B and C)7.13 Alarm counter8.3 Point fault signal8.9 Output to remote fault or warning signalling devices9.5 Addressable points out-of-service10.0 Test conditionOptions provided in accordance with EN12094-10051INIM Electronics s.r.l.Via Dei Lavoratori 10 - Fraz. Centobuchi63076, Monteprandone (AP) - Italy180051-CPR-1499EN 54-2:1997 A1:2006EN 54-4:1997 A1:2002 A2:2006EN 54-21:2006EN 12094-1:2003PREVIDIA-C050SG, PREVIDIA-C050SR, PREVIDIA-C050SZG,PREVIDIA-C050SZR, PREVIDIA-C050SZEG, PREVIDIA-C050SZER,PREVIDIA-C100SG, PREVIDIA-C100SR, PREVIDIA-C100SZG,PREVIDIA-C100SZR, PREVIDIA-C100SZEG, PREVIDIA-C100SZER,PREVIDIA-C200SG, PREVIDIA-C200SR, PREVIDIA-C200SZG,PREVIDIA-C200SZR, PREVIDIA-C200SZEG, PREVIDIA-C200SZERControl and indicating equipment with power supply equipment, alarmtransmission and fault warning routing equipment and electrical automaticcontrol and delay device integrated for fire detection and fire alarm systemsinstalled in buildings and for gas extinguishing systems installed inbuildings and part of a complete ASSPASS4.17 Delay of extinguishing signal4.18 Signal representing the flow of extinguishing agent4.19 Monitoring of the status of components4.20 Emergency hold device (*)4.21 Control of flooding time4.23 Manual only mode4.24 Triggering signals to equipment within the system4.26 Triggering of equipment outside the system4.27 Emergency abort device (*)4.30 Activation of alarm devices with diverse signals(*) one only between 4.20 and 4.27Additional information according to EN 54-2About information required at point 12.2.1, see data contained in thismanual.Additional information according to EN 54-4For the information required by point 7.1, see data contained in thismanual.Additional information according to EN 54-21For the information required by point 7.2.1, see data contained in thismanual.Additional information according to EN 12094-1Environmental class: ADegree of protection: IP30Flooding zones: 1Zones for CO2, inert gas or halogenated hydrocarbons.Response delay activation condition: max 3sResponse delay triggering of outputs: max 1sGeneral information

User’s manual1.4.2 Directive 2014/53/EUHereby, INIM Electronics S.r.l. declares that these Previdia Compact are in compliance with the essential requirementsand other relevant provisions of Directive 2014/53/EU.Following paragraph explains how to download the complete Declaration of Conformity.This product may be used in all EU Countries.1.4.3 Documents for the usersDeclarations of Performance, Declarations of Conformity and Certificates concerning to INIM Electronics S.r.l. productsmay be downloaded free of charge from the web address www.inim.biz, getting access to Extended Access and thenselecting "Certifications" or requested to the e-mail address info@inim.biz or requested by ordinary mail to the addressshown in paragraph 1.4.1.Manuals may be downloaded free of charge from the web address www.inim.biz, getting access to Extended Access andthen selecting "Manuals".General information7

Fire detection and extinguishant systemChapter 2Operative statuses of the Previdia Compact systemStandby: Operating status of the control panel when there is no ongoing alarm or fault signalling.This status is altered by the occurrence of an event, that is, an operative status which is characterized by an activation(when the event occurs) and a reset (when the event ends).Alarm: Status of the control panel generated by manual activation (for instance, from a call point) or automaticactivation (signal from a detector). This is followed by an alarm signal.Pre-alarm: This is the status of the control panel during the interval (delay) which runs between the detection of analarm condition and the actual signalling of the alarm (delay).Investigate: This command is activated by a supervisor, during an early-warning condition, it provides an extension ofthe early-warning delay and allows the supervisor to verify the cause of the alarm.Evacuate: This command is activated by a supervisor, during an early-warning condition, it cancels the delay andinstantly activates alarm signalling (evacuation).Reset: This operator-activated command annuls the current status of the control panel (and the relative signalling andactivations) and resets the system to standby.This command can be disabled in order to prevent users from activating it by mistake and annulling active signals.Disable: This command disables part of the system8Operative statuses of the Previdia Compact system

User’s manualChapter 3User interface3.1Front plate modelsThe user interface of the Previdia Compact control panel consists of a touch-screen display, buttons and LED indicatorsmounted on the front plate.Depending on the control panel model, there are three different types of user interfaces:PREVIDIACxxxxxStandard modelTEST01 02 03 04 05PREVIDIACxxxxZxModel with LEDindicators forsignalling the statusof the zones06 07 08 09 1011 12 13 14 15161718 19 2021 22 23 24 2526 27 28 29 30TESTPREVIDIACxxxxZExModel with LEDindicators forsignalling the statusof the zones andmanagement of theextinction channel01 02 03 04 0506 07 08 09 1011 12 13 14 15161718 19 2021 22 23 24 2526 27 28 29 30TESTAll information provided by the control panel and on its front plate is also available via a repeater, this is a device whichallows you to view the information from a remote location. There are two different repeater models available, withdifferent user interfaces:PREVIDIA-CREPStandard modelPREVIDIA-CREPEModel withextinction channelmanagementUser interface9

Fire detection and extinguishant system3.2Function buttons and LEDsThe LEDs on the sides and below the screen provide visual signals which indicate the general status of the system,whereas the function buttons allow fast execution of all the main operations.The key permits level 1 (public level) to pass to level 2 (supervisor level). When turned clockwise the key will generate apulse which places the control panel in level 2 status. The control panel will return to level 1 if no buttons are pushedwithin 20 seconds.[A]Touchscreen display[B]Status LED[C]Function buttons[D]LED and multiple-alarmbuttonFB01 02 03 04 05CG06 07 08 09 1011 12 13 14 1516[E]Access-key slot[F][G]Extinction channel status LED(only on certain models)D26 27 28 29 30TESTEColourOn solidFlashingRedFire alarm running.Fire alarm memory.FaultYellowA fault (of any type) is present on thesystem.The details of any active faults areshown on the screen.Fault memory.A fault has been solved.ONGreenThe system is functioning.CPU FaultYellowThe CPU of the control panel is outof service or one of themicrocontrollers inside the cabinetdoes not respond.If the fault does not clear when theReset button is pressed, contact thetechnical-assistance service.DisabledYellowOne or more of the systemelements has been disabled.TestYellowOne or more of the systemelements has been put in test mode.Alarm10A18 19 2021 22 23 24 25Zone status LEDs(only on certain models)Status LED17CPU fault memory.The control panel CPU has reset andrestarted.User interface

User’s manualFunction LEDsColourOn solidFunction buttonSignallingtestYellowThe test on the visualsignalling devices is running.If this button is pressed and held all the LEDson the control panel will light.EvacuateRedThe evacuation phase hasbeen activated manually.Button for manual activation of the signallingdevices (audible and visual) for evacuation ofthe premises.InvestigateYellowThe investigation time hasbeen activated.Button to request supplementary investigationtime and thus lengthen the early-warningperiod.SilencebuzzerYellowThe buzzer has beensilenced.This button silences the control panel buzzer.Events which occur after silencing willreactivate the buzzer.YellowThe sounders have beensilenced.During alarm status, this button can be usedto stop the audible and visual signallingdevices.Pressing this button again will reactivate thesilenced audible and visual signalling devices.ResetYellowThe reset function isdisabled. The soundersmust be silenced before theReset function can be reenabled.Button for the annulment of active events andthe reset of standby conditions.MultiplealarmsRedMore than one alarm isactive on the system.This button allows you to scroll through theactive alarm events on the screen.Silencesounder3.3Screen in standby status[A]Buttons to access the eventslogs, system status andprogramming.[B]Status bar (always present)shows essential informationregarding the system.[C]Customizable area(customizable during theprogramming phase) for imagesrelating to the status of thesystem elements or customizedfunction buttons .[D]Date and Time of the systemSelection of the indicationaccesses (at level 2) the dateand time setting window[E]Button to change the languageused by the control panel, ifrequired by the configurationUser interfaceLogSystem statusCAProgrammingDBL:101/01/2020 18:23E11

Fire detection and extinguishant system3.4Status BarIconFunctionAccess level:1LanguageselectionSelection of this area allows you to enter a code and change the current user-accesslevel.- 1 Public level (no code entry)- 2 Supervision level (turn key or user code entry)- 3 Programming level (installer code entry)

EXTINGUISHANT SYSTEM CONTROL PANEL, ALARM TRANSMISSION AND FAULT WARNING ROUTING EQUIPMENT 0051 0051-CPR-1498 0051-CPR-1499. 2 Warranty Fire detection and extinguishant system Warranty INIM Electronics s.r.l. (Seller, Our, Us) warrants the original

Related Documents:

addressable fire alarm control panel 2 loop addressable fire alarm control panel 4 loop addressable fire alarm control panel 6 loop addressable fire alarm control panel 8 loop addressable fire alarm control panel product code: m.u.yan.00016 product code: m.u.yan.00018 battery included product code: m.u.yan.00020 product code: m.u.yan.00022

The conventional fire alarm detection process of our country cannot locate the exact fire origin on time causing fire hazards. The addressable fire alarm system resolves the problem by assigning a unique address to each detector to locate the exact position of the fire for further protection system. In this paper, an addressable fire alarm

Extinguishant Control System HP102-4 Extinguishant Control panel 20 HF115/116/119 Components of extinguishant system 21 Schematic diagram of extinguishant control system 22 Addressable Fire Alarm System HD201/202/203 Addressable fire alarm detectors 24 HC202/HM201-R Addressable call poin

NFS2-640 Intelligent Addressable Fire Alarm System Intelligent Fire Alarm Control Panels dn-7111:b † A-13 NFS2-640 7111pho2.jpg General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-large system, or as a File Size: 710KBPage Count: 10

Addressable Device - A fire alarm system component with discreet identification that can have its status individually identified or that is used to individually control other functions. Analog Addressable Sensor - An initiating device that transmits a signal indicating varying degrees of condition as contrasted with a conventional or addressable initiating device, which can only indicate an .

Alarm 1 is a ‘Sound Once’ alarm, and Alarm 2 is an ‘Everyday’ alarm. Alarm 1 Setting/Alarm 2 Setting Press the ‘Alarm 1’ button (Ref.4) or ‘Alarm 2’ button (Ref.5) to activate alarm settings. ‘OFF’ will begin lashing on the screen. Select Alarm 1 or 2 b

Run Card Requirements Continued Structure Fire goes to 7th Alarm and all 7 Alarm and all 7 Alarms are required. Brush Fire goes to 7th Alarm and all 7 Alarm and all 7 alarms are required. All other incident types can go to 4th Alarm Alarm and minimum of 2nd alarm is required.alarm is required. When a Compan

Analog addressable fire alarm controls combined with integrated Emergency Communications Systems. The seamless combination of fire detection and emergency communication simplifies operation and programming of the entire system. Fire alarm, CO alarm, and ECS combined in one easy to operate system in your choice of red or black cabinet.