HaemodialysisBloodlines, Tubing Systems, AccessoriesProduct Range1201/0102

5008 Therapy System – the innovation Enabling the application of ONLINE Haemodiafiltration in the most practical way.ONLINE Priming / ONLINE HDF Saline free priming of extracorporeal circuitt ONLINE HDF treatment as standard Enabled by the SafeLine included in everyTechnical changes reservedbloodline setReliable PrecisionConvenience Exact measurement of arterial pressure via Clear layout and optimised tube lengthspressure dome Trouble-free air detection directly on system tube2 Machine assisted set-up and disassembling Reduced filling volume and less blood-air contactBloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

4008 Sustained dependabilityReliability established over several years and millions of treatments.Superior quality and safety Consistent and validated manufacturing Rigorous testing of bloodline performance Highly compatible interface between bloodlines andReliable therapyMeeting diverse needs Matured technology recognised worldwide Appropriate sterilisation to suit varying demands Extensive experience in the production of blood- Broad product range to meet all requirementsTechnical changes reservedmachinelines – ensuring consistent product qualityBloodlines, Tubing Systems, Accessories – Product Range – 2010/20113

Ensuring safety with the authenticFresenius Medical Care Original Bloodlines .terfaceGuaeeInQuality and reliability characterise the Fresenius bloodlines in function and use.ranHandlingSafety Clearly colour-coded components Assurance of highest safety and performance with Ergonomic components and layoutour 4008 and 5008 machines Transducer protector with integrated inspectionwindowsTechnical changes reserved Injection port with enlarged finger-protection shieldQualityBiocompatibility Certified quality systems for development, Use of plasticisers with high haemocompatibilityproduction and sales Perfect compatibility to machine interfaces4and low cytotoxic reaction Free of DEHPBloodlines, Tubing Systems, Accessories – Product Range – 2010/2011t

Product Range 5008freeDEHPLifeLineBeta Phtalate free Beta-sterilisation by accelerated electrons(e-beam) Fewer material alterations incomparison to gamma-irradiation No radioactive source of radiationAdult BloodlinesBeta sterilisation – DEHP freeTypeTo be used withFilling volumeUnits per boxArt.-No.AV-SetsAV-Set ONLINEplus 5008-R5008/5008S132 ml24F00000384AV-Set ONLINEplus BVM 5008-R5008136 ml24F00000385AV-Set ONLINE Priming 5008S-R5008S132 ml24F00000700SN-Set ONLINEplus 5008-R5008/5008S166 ml20F00000386SN-Set ONLINEplus BVM 5008-R5008169 ml20F00000387SN-SetsPaediatric BloodlinesBeta sterilisation – DEHP freeTypeTo be used withInner diameterpump segmentFilling volumeUnits per boxArt.-No.50088 mm108 ml24F0000106850088 mm142 ml20F00001069AV-SetsAV-Set ONLINEplus BVM Paed 5008-RSN-Set ONLINEplus BVM Paed 5008-RBVM:-R:Technical changes reservedSN-SetsBlood Volume MonitorBeta Sterilisation (Radiation)Inner diameter of pump segment: 8 mmDiameter of venous bubble catcher: 22 mmBloodlines, Tubing Systems, Accessories – Product Range – 2010/20115

Product Range 4008efreDEHPLifeLineBeta Phtalate free Sterilisation by accelerated electrons (e-beam) Less material alterations in comparison togamma-irradiation No radioactive source of radiationAdult BloodlinesBeta sterilisation – DEHP freeTypeTo be used withFilling volumeUnits per boxArt.-No.AV-Set B-R2008/4008161 ml24F00001124AV-Set SRB-R2008/4008161 ml24F000002574008172 ml24F00000258SN-Set B-R2008/4008197 ml20F00001125SN-Set SRB L-R2008/4008211 ml20F000002594008225 ml20F00001132To be used withInner diameterpump segmentFilling volumeUnits per boxArt.-No.2008/40086.4 mm117 ml24F0000106440086.4 mm126 ml24F000010652008/40086.4 mm56 ml24F00001063AV-SN-Set-FMC Paed R2008/40086.4 mm155 ml24F00001067AV-SN-Set-FMC Paed/Baby R2008/40086.4 mm88 ml24F00001066AV-SetsAV-Set SRB BVM-RSN-SetsSN-Set SRB L BVM-RPaediatric BloodlinesBeta sterilisation – DEHP freeTypeAV-SetsAV-Set-FMC Paed RAV-Set-FMC BVM/BTM Paed RAV-Set-FMC Paed/Baby RSN-SetsAll paediatric bloodlines 4008 are equipped with spike, waste bag and recircirculculatiationon conc nnecnectortor.Technical changes reservedS:R:B:L:BVM:-R:SpikeRecirculation connectorWaste bagLong tubes to SN expansion chamber(needed for SN-treatment with 4008 S)Blood Volume MonitorBeta Sterilisation (Radiation)Inner diameter of pump segment: 8 mmDiameter of venous bubble catcher: 22 mm6Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

Product Range 4008BasicLine Sterilisation by ethylene oxide Special pre-conditioning anddegassing process leads tominimised residual ETO contentAdultAdult BlulBlooodloodlininesesETO stETsteeriilisatatioionnTypeTo be nectorUnitsper boxArt.-No.AV-Set-FMC (FA 204 C/FV 204 C)2008/4008161 ml 245000541AV-Set-FMC (FA 204 B/FV 204 B)2008/4008161 ml245000561AV-Set-FMC (FA 204 C/FV 204 E)2008/4008161 ml 2450034514008172 ml 2450166312008/4008211 ml 205017411AV-SetsAV-Set-FMC (FA 204 C/FV 204 E) BVM AV-SN-Set-FMC (FA 514 SN C/FV 204 E)BVM:Technical changes reservedSN-SetsBlood Volume MonitorInner diameter of pump segment: 8 mmDiameter of venous bubble catcher: 22 mmBloodlines, Tubing Systems, Accessories – Product Range – 2010/20117

Fresenius Medical Care’s bloodline components 8Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

developed to meet all your needsBloodlines, Tubing Systems, Accessories – Product Range – 2010/201113

ComponentsPatient connectorsOptimal handling and safety: Ergonomic grip on the rotating part ensuressecure connection Easy to remove protective capsInjection ports Latex-free septum Colour coding Large finger-protection shieldPump segment 4008 / 5008 Perfect fit to the Fresenius Medical Care dialysisTechnical changes reservedmachines (geometry, shore hardness, occlusionperformance)- Qualified for the effective blood flow measurement- Allows achievement of prescribed dialysis dose9Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

ComponentsLine clamps Colour coding Optimal ergonomics for easy and reliable handling No additional clamps requiredTransducer protectors Inspection windowsTechnical changes reserved Colour codingHeparin line Luer-Lock female Adapter with protecting cap Easy to remove paper tape10Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

ComponentsCorrect filling levelArterial bubble catcher Dynamic blood flow due to special geometry Safe and effective air separationSingle Needle chamber Dynamic blood flow Level mark for easy handlingCorrect filling levelVenous bubble catcher Inlet distributor reduces activation of clotting- No "free fall" of blood Allows an easy and correct positioning in the air detectordue to the special shape of venous bubble trap (22 mm Ø)Bloodlines, Tubing Systems, Accessories – Product Range – 2010/201111Technical changes reserved- Directed blood flow

ComponentsDialyser connector Soft material allows safe connection to dialyser Easy to remove protective capsPressure dome Precise pressure measurement Reduced filling volumeTechnical changes reserved No blood-air contactBVM cuvette Precise BVM measurement Easy handlingBloodlines, Tubing Systems, Accessories – Product Range – 2010/201112

Technical drawings 5008AV-Set ONLINEplus 5008-R(F00000384)Arterial lineVenous lineSafeLineVariants(Venous line and SafeLineunchanged)SN-Set ONLINEplus 5008-R(F00000386)AV-Set ONLINEplus BVM 5008-RTechnical changes reserved(F00000385)SN-Set ONLINEplus BVM 5008-R(F00000387)14Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

Technical drawings 4008AV-Set SRB-R(F00000257)Arterial lineVenous lineVariants(Venous lines unchanged)SN-Set B-R(F00001125)AV-Set SRB BVM-R(F00000258)AV-SN-Set-FMC (FA 514-SN C/FV 204E) BVMTechnical changes reserved(5017411)SafeLine(F00001195)Bloodlines, Tubing Systems, Accessories – Product Range – 2010/201115

Technical drawings paediatric lines5008AV-Set ONLINEplus – BVMPaed 5008-R(F00001068)Arterial lineVenous lineSafeLine4008AV-Set-FMC Paed R(F00001064)Arterial lineVenous lineAV-Set-FMC Paed/Baby R(F00001063)Technical changes reservedArterial lineVenous line16Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

Important handling aspects Pressure lineConnect the pressure transducer protector to themachine ensuring it is straight and secure (do notovertighten!). If the membrane is wet, replace eitherthe bloodline or the pressure line with a new one.Arterial bubble catcherCorrCorrecectt fifilllling levelFor level setting release the cap, raise the level slowlyto the filling line. Make sure that the caps are secureCorrect fifillllinCoingg levevelland the clamps closed.Venous bubble catcher (4008)Rest the shoulder of the chamber on the top of thelevel detector holder, so the filter of the chamber is1 cm below the level of the door.Make sure that the caps are secure and the clampsclosed.Pump segment (4008)Insert the pump segment with the red colour codingon the left hand side.SN-pump segment (4008)Make sure that all air has been removed duringthe priming of the pump segment.Injection portClean the septum by using an alcohol wipe. Holdthe injection port by the finger grips underneath theprotection shield. Insert the needle directly into theseptum (90 ).SN-chamberPlace the chamber into the holder.Connect the pressure line (see above).Make sure that the caps are secure andTechnical changes reserved1 cmmthe clamps closed.Do not invert the chamber.During priming, the filling level will be set automatically(do not raise the level manually).Bloodlines, Tubing Systems, Accessories – Product Range – 2010/201117

AccessoriesTo be ine4008Tubing system FS 130ConnectorsUnits perboxArt.-No.ONLINEplus HDF 5008127030031BetaONLINEplus 4008,pump segment 6.4 mm100F000011954008ETOStandard HDF, Pump segment4.4 mm405046301Frekaflex infusion set4008ETOInfusion set Luer-Lock male/Luer-Lock male with rollerclamp1502889011Infusion set4008ETOInfusion set with vented spike,Luer-Lock male and dripchamber1505016371Transfer set4008ETOInfusion set Luer-Lock male /Luer-Lock male15050163914008ETORinsing of extracorporeal circuit1005015091Transducer protector4008/5008ETOLuer-Lock male/female1005015911Pressure line 30 cm4008/5008ETOComplete pressure line 30 cm,Luer-Lock male/female1005014631Pressure line 60 cm4008/5008ETOComplete pressure line 60 cm,Luer-Lock male/female2005019151Heparin syringe 30 ml5008ETOLuer-Lock male, separateclosure cap, latex-free plug1005030321Heparin syringe 20 ml4008/5008ETOLuer-Lock male, separateclosure cap, latex-free plug120F0000125*SN-adapter Luer-Lock4008/5008ETOY-adapter, 2 x Luer-Lockfemale, 1 x Luer-Lock male1005027851HF / HDFDrainage connectorInfusion setsWaste bagsWaste bag 2,000 mlTransducer protectorsVarious accessoriesTechnical changes reserved* coming soon18Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011

AccessoriesTypeTo be usedwithSterilisationDescriptionScissor clamp4008/5008---For clamping tubesRecirculation connector4008/5008BetaAdapter Luer-Lock female /Luer-Lock female4008/5008Adapter Luer-Lock male /Luer-Lock maleConnectorsUnits perboxArt.-No.52845241For short-circuit of A/V-set,Luer-Lock female / Luer-Lockfemale1005015971ETOFor short circuit of bloodtubings (A/V-sets)10050148014008/5008ETOFor short circuit of er-Lock female1005015921Prolongation 75 cm4008/5008BetaLuer-Lock male/female1007030011Dialyser exchange set4008/5008ETOTubing system for exchangeof dialyser during treatment,short-circuit AV-set755018001MountsUniversal mount, single4008---Mount for arterial bubble trapfor 4008 E/H15000271Universal mount, double4008---Mount for arterial bubble trapand SN expansion chamber,for 2008 and 4008 B/S15000261proHD Set SETODrape, nitrile gloves, non-wovengauzes, adhesive tapes,haemostatic plasters170F00000836proHD Set METODrape, nitrile gloves, non-wovengauzes, adhesive tapes,haemostatic plasters170F00000837proHD Set LETODrape, nitrile gloves, non-woven170F00000838HD Connection-Disconnection Setgauzes, adhesive tapes,haemostatic plastersTechnical changes reservedThe letters S, M and L in the name of the proHD Sets indicate the glove size. For more detailed information see brochure F00001561Bloodlines, Tubing Systems, Accessories – Product Range – 2010/201119

Copyright 2010 Fresenius Medical Care Deutschland GmbHF00001752 GB (1 A&O 09.10)Head office: Fresenius Medical Care Deutschland GmbH · 61346 Bad Homburg v. d. H. · Germany · Phone: 49 (0) 6172-609-0 · Fax: 49 (0) 6172-609-2191Else-Kröner-Straße 1 · 61352 Bad Homburg v. d. H.www.fmc-ag.com

Bloodlines, Tubing Systems, Accessories – Product Range – 2010/2011 5 Technical changes reserve d Paediatric Bloodlines Type To be used with Inner diameter pump segment Filling volume Units per box Art.-No. AV-Sets AV-Set ONLINEplus BVM Paed 5008-R 5008 8 mm 108 ml 24 F00001068 SN-Sets SN-Set ONLINEplus BVM Paed 5008-R 5008 8 mm 142 ml 20 .

Related Documents:

Tubing bender – easily bends copper and stainless tubing up to 180 without kinking Tubing reamer – opens and rounds tubing after cutting Description Cat. No. TC-20 Tubing Cutter (110/220 V) 58539-U Heavy Duty Tubing Cutter 20425-U 1/8 inch O.D. Tubing Bender 20422-U 1/4 inch O.D. Tubing Bender 20424-U Tubing Reamer 20389 Swagelok .

Bloodlines The sorcerer bloodlines in the Pathfinder RPG rulebook allow great variety within a single class. Yet, the bloodlines only hint at the dif-ferences that might exist among sorcerers. Not all undead are the same. Good and evil outsiders range beyond devils and angels. Some aberrations display a

the installation of Swagelok single-jacketed tubing, multijacketed tubing, insulated tubing, and pre-insulated trace tubing bundles. For additional information, see the Swagelok Multijacketed Tubing, Jacketed Tubing and Insulated Tubing catalog, MS-02-188 and Swagelok Pre-Insulated Tubing Bundles catalog, MS-02-316. Caution

AKTApurifier 100 , 0.50 tubing kit 232 382 AKTApurifier 100 , 0.75 tubing kit 470 620 AKTApurifier 100 , 1.00 tubing kit 769 809 AKTApurifier 100 , 0.50 tubing kit pH electrode 354 504 AKTApurifier 100 , 0.75 tubing kit pH electrode 672 862 AKTApurifier 100 , 1.00 tubing kit pH electrode 955 995 AKTAbasic 100 , 0.75 tubing 290

Insulated, and Pre-Insulated Tubing Installation Instructions These instructions provide the user with information for the installation of Swagelok single-jacketed tubing, multijacketed tubing, insulated tubing, and pre-insulated trace tubing bundles. For additional information, see the Swagelok Multijacketed Tubing, Jacketed Tubing and

Size of Pipe or Copper Tubing, Inches Size of Pipe or Copper Tubing, Inches Copper Tubing (O.D.) Copper Tubing (O.D.) Pipe Size Pipe Size 10 125 20 150 30 175 40 200 50 225 60 250 70 275 80 300 90 350 100 400 Length of Pipe or Tubing, Feet Length of Pipe or Tubing, Feet Maximum capacity of pipe or tubing in thousands of BTU/hr of LP-Gas

Bloodlines of the Illuminati by Fritz Springmeier BLOODLINES OF THE ILLUMINATI by Fritz Springmeier 1. The Astor Bloodline FDR and Lady Astor - 2 socialists DIFFICULTY IN DETERMINING THE FACTS. ORIGIN OF THE FAMILY & its NAME THE FAMILY IN EUROPE JOHN JACOB ASTOR GOES TO AMERICA OVERVIEW

Mechanical engineering applies the principles of mechanics and energy to the design of machines and devices. Perhaps the broadest of all engineering disciplines, mechanical engineering is generally combined into three broad areas: energy, structures and motion in mechanical systems, and manufacturing. [mech] - general