Instrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Armored, Lead Sheath & Flame Retardant (Underground)Cable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: PVC (EN50290-2-21) / PE (EN50290-2-23) / XLPE &FRXLPE (EN50290-2-29 / HFFR-XLPE (EN50290-2-26).Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Application:Can be used in cable tray or conduit or external buried &underground ducts (suitable for hydrocarbon resistance) toconnect electrical instrumentation and communication circuitsand industrial process controls, refineries, oil, gas andpetrochemical plants.Operating temperature:- 15 C to 70 C &- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:20 X Cable Overall DiameterIndividual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/tiad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of individual screened pairs/triads/quad with anoverlap of 25% with metallic side down in contact with a strandedannealed tinned copper drain wire of 0.5mm² (7x0.3mm).Inner Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Lead Sheath: Lead Alloy to EN50307.Cable TypeCU/PE/ISCR/OSCR/PVC/LC/PVC/GSWA or DGST/PVCCU/PE/ISCR/OSCR/LSZH/LC/LSZH/GSWA or DGST/LSZHCU/PVC/ISCR/OSCR/PVC/LC/PVC/GSWA or CCU/XLPE/ISCR/OSCR/LSZH/LC/LSZH/GSWA or DGST/LSZHCU/FRXLPE/SCR/OSCR/PVC/LC/PVC/GSWA or T /LSZHAbbreviation:CU CopperPVC Polyvinyl ChloridePE PolyethyleneXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenLC Lead CompoundGSWA Galvanized Steel Wire armoredDGST Double Galvanized Steel TapeBedding: Flame Retardant PVC (EN50290-2-22) / LSZH (EN50290-227).Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape (DGST) to EN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7Basic Design (300 or 500V)IEC 60332-3Flame Retardant (Category A, B or Caccording to Request)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2Low Smoke Emission (only LSZH)ICEA S-73-532/Oil ResistanceIEC60811-404UL 1581/ISO4892UV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

Instrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Multi Layer sheath & Flame Retardant (Underground)Cable TypeCU/PE/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/PVCCU/PE/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/LSZHCU/PVC/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/PVCCU/XLPE/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/PVCCU/XLPE/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/LSZHCU/FRXLPE/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/PVCCU/FRXLPE/ISCR/OSCR/AL/HDPE/PA/GSWA or GST/LSZHApplication:This is the alternative of lead sheath cables (known asenvironmental friendly) and can be used in cable tray or conduitor direct buried (suitable for hydrocarbon resistance) to connectelectrical instrumentation and communication circuits andindustrial process controls, refineries, oil, gas and petrochemicalplants.The multilayer protection has lower weight and smaller diametercompared to lead sheath with an excellent protection againstcorrosion and humidity.Operating temperature:- 15 C to 70 C &- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:20 X Cable Overall DiameterCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: PVC (EN50290-2-21) / PE(EN50290-2-23) / XLPE &FRXLPE (EN50290-2-29 / HFFR-XLPE(EN50290-2-26).Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair with an overlap of 25% with metallic side down incontact with a stranded tinned copper drain wire of 0.5mm² (7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen & Multilayer Sheath: An Aluminum (AL) Foil(0.20mm) coated on up side with a protective plastic coating (0.05mm)is applied longitudinally over the assembly to form laminated aluminummoisture barrier sheath. A stranded tinned copper drain wire of0.5mm2 (7x0.3mm) run longitudinally in contact with the Aluminumside of the Aluminum tape. A Black extruded bedding of High DensityPolyethylene compound meeting the requirement of EN 50290-2-24,shall be applied over the Aluminum Foil and shall be bonded to theAluminum Foil. Over the High Density Polyethylene bedding aprotective sheath 0.3mm of Black Polyamide shall be extruded.Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape (DGST) to EN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:Abbreviation:CU CopperPVC Polyvinyl ChloridePE PolyethyleneXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenPA PolyamideHDPE High Density PolyethyleneGSWA Galvanized Steel Wire ArmorDGST Double Galvanized Steel TapeBS EN 50288-7Basic Design (300 or 500V)IEC 60332-3Flame Retardant (Category A, B or Caccording to Request)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

Instrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Armored & Flame Retardant (Outdoor Application)Cable TypeCU/PE/ISCR/OSCR/PVC/GSWA or DGST or GSWB/PVCCU/PE/ISCR/OSCR/PE/GSWA or DGST or GSWB/PVCCU/PE/ISCR/OSCR/LSZH/GSWA or DGST or GSWB/LSZHCU/PVC/ISCR/OSCR/PVC/GSWA or DGST or GSWB/PVCCU/XLPE/ISCR/OSCR/PVC/GSWA or DGST or GSWB/PVCCU/XLPE/ISCR/OSCR/PE/GSWA or DGST or GSWB/PVCCU/XLPE/ISCR/OSCR/LSZH/GSWA or DGST or GSWB/LSZHCU/FRXLPE/ISCR/OSCR/PVC/GSWA or DGST or CCU/FRXLPE/ISCR/OSCR/LSZH/GSWA or DGST orGSWB/LSZHApplication:Can be used in cable ladder rack or tray in the open airexposed to direct sunlight or conduit or external buried toconnect electrical instrumentation and communication circuitsand industrial process controls, refineries, oil, gaspetrochemical plants.Operating temperature:- 15 C to 70 C &- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:12 X Cable Overall DiameterCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: PVC (EN50290-2-21) / PE (EN50290-2-23) / XLPE &FRXLPE (EN50290-2-29 / HFFR-XLPE (EN50290-2-26).Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of pairs/triads/quad with an overlap of 25% withmetallic side down in contact with a stranded annealed tinned copperdrain wire of 0.5mm² (7x0.3mm).Inner Sheath: Flame Retardant PVC (EN50290-2-22) / PE (EN50290224) / LSZH (EN50290-2-27).Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape or Galvanized steel wire braid (GSWB) toEN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7Abbreviation:CU CopperPVC Polyvinyl ChloridePE PolyethyleneXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenGSWA Galvanized Steel Wire ArmorDGST Double Galvanized Steel TapeGSWB Galvanized Steel Wired BraidBasic Design (300 or 500V)IEC 60332-3Flame Retardant (Category A, B or Caccording to Request)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

Instrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Unarmored & Flame Retardant (Indoor Application)Cable /OSCR/LSZHApplication:Can be used in cable ladder rack or tray in the open air exposedto direct sunlight or within buildings to connect electricalinstrumentation and communication circuits and industrialprocess controls, refineries, oil and gas plants.Operating temperature:- 15 C to 70 C &- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:12 X Cable Overall DiameterCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: PVC (EN50290-2-21) / PE (EN50290-2-23) / XLPE &FRXLPE (EN50290-2-29 / HFFR-XLPE (EN50290-2-26).Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of pairs/triads/quad with an overlap of 25% withmetallic side down in contact with a stranded annealed tinned copperdrain wire of 0.5mm² (7x0.3mm).Outer Sheath: Flame Retardant PVC(EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7Abbreviation:CU CopperPVC Polyvinyl ChloridePE PolyethyleneXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenBasic Design (300 or 500V)IEC 60332-3Flame Retardant (Category A, B or Caccording to Request)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

EverprojectInstrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Armored, Lead Sheath & Fire Resistance (Underground)Cable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: MICA Impregnated Glass Tape XLPE & FRXLPE(EN50290-2-29 /HFFR-XLPE (EN50290-2-26) or SR EI2 (EN50363-1)Application:Fire Resistance/F&G Safe circuit cable can be used in cable trayor conduit or external buried & underground ducts (suitable forhydrocarbon resistance) to connect electrical instrumentation andcommunication circuits and industrial process controls, refineries,oil, gas and petrochemical plants.Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Operating temperature:- 15 C to 90 CCabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Recommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:20 X Cable Overall DiameterCable PVCCU/MICA/FRXLPE/ISCR/OSCR/LSZH/LC/LSZH/GSWA /GSWA or DGST/LSZHCU/SR/ISCR/OSCR/PVC/LC/PVC/GSWA or ZHAbbreviation:CU CopperPVC Polyvinyl ChlorideXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenLC Lead CompoundGSWA Galvanized Steel Wire armoredDGST Double Galvanized Steel TapeIndividual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of individual screened pairs/triads/quad with anoverlap of 25% with metallic side down in contact with a strandedannealed tinned copper drain wire of 0.5mm² (7x0.3mm).Inner Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Lead Sheath: Lead Alloy to EN50307.Bedding: Flame Retardant PVC (EN50290-2-22) / LSZH (EN50290-227).Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape (DGST) to EN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7Basic Design (300 or 500V)IEC 60332-3IEC60331-21/BS6387Flame Retardant (Category A, B or Caccording to Request)Fire Resistance/Protocols (C W Z)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2Low Smoke Emission (only LSZH)ICEA S-73-532/Oil ResistanceIEC60811-404UL 1581/ISO4892UV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

EverprojectInstrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Multi Layer Sheath & Fire Resistance (Underground)Cable ZHCU/MICA/HFFR-XLPE/ISCR/OSCR/AL/HDPE/PA/GSWAor DHST/LSZHCU/SR/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/PVCCU/SR/ISCR/OSCR/AL/HDPE/PA/GSWA or DGST/LSZHApplication:This is the alternative of lead sheath cables (known asenvironmental friendly). Fire Resistance/F&G Safe circuit cablecan be used in cable tray or conduit or direct buried (suitable forhydrocarbon resistance) to connect electrical instrumentation andcommunication circuits and industrial process controls, refineries,oil, gas and petrochemical plants.The multilayer protection has lower weight and smaller diametercompared to lead sheath with an excellent protection againstcorrosion and humidity.Operating temperature:- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:20 X Cable Overall DiameterCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: MICA Impregnated Glass Tape XLPE & FRXLPE(EN50290-2-29 /HFFR-XLPE (EN50290-2-26) or SR EI2 (EN50363-1)Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen & Multilayer Sheath: An Aluminum (AL) Foil(0.20mm) coated on up side with a protective plastic coating (0.05mm)is applied longitudinally over the assembly to form laminated aluminummoisture barrier sheath. A stranded tinned copper drain wire of0.5mm2 (7x0.3mm) run longitudinally in contact with the Aluminumside of the Aluminum tape. A Black extruded bedding of High DensityPolyethylene compound meeting the requirement of EN 50290-2-24,shall be applied over the Aluminum Foil and shall be bonded to theAluminum Foil. Over the High Density Polyethylene bedding aprotective sheath 0.3mm of Black Polyamide shall be extruded.Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape (DGST) to EN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:Abbreviation:CU CopperPVC Polyvinyl ChlorideXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenPA PolyamideHDPE High Density PolyethyleneGSWA Galvanized Steel Wire ArmorDGST Double Galvanized Steel TapeBS EN 50288-7Basic Design (300 or 500V)IEC 60332-3IEC60331-21/BS6387Flame Retardant (Category A, B or Caccording to Request)Fire Resistance/Protocols (C W Z)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

EverprojectInstrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Armored & Fire Resistance (Outdoor Application)Cable TypeCU/MICA/XLPE/ISCR/OSCR/PVC/GSWA or DGST orGSWB/PVCCU/MICA/XLPE/ISCR/OSCR/LSZH/GSWA or DGST orGSWB/LSZHCU/MICA/FRXLPE/ISCR/OSCR/PVC/GSWA or DGST orGSWB/PVCCU/MICA/FRXLPE/ISCR/OSCR/LSZH/GSWA or DGST orGSWB/PVCCU/MICA/HFFR-XLPE/ISCR/OSCR/PVC/GSWA or DGSTor GSWB/PVCCU/MICA/HFFR-XLPE/ISCR/OSCR/LSZH/GSWA or DGSTor GSWB/LSZHCU/SR/ISCR/OSCR/PVC/GSWA or DGST or Application:Fire Resistance/F&G Safe circuit cable can be used in cableladder rack or tray in the open air exposed to direct sunlight orconduit or external buried to connect electrical instrumentationand communication circuits and industrial process controls,refineries, oil, gas petrochemical plants.Operating temperature:- 15 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:12 X Cable Overall DiameterCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: MICA Impregnated Glass Tape XLPE & FRXLPE(EN50290-2-29 /HFFR-XLPE (EN50290-2-26) or SR EI2 (EN50363-1)Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of pairs/triads/quad with an overlap of 25% withmetallic side down in contact with a stranded annealed tinned copperdrain wire of 0.5mm² (7x0.3mm).Inner Sheath: Flame Retardant PVC (EN50290-2-22) / PE (EN50290224) / LSZH (EN50290-2-27).Armor: A single layer of Galvanized steel wire armor (GSWA) orDouble galvanized steel tape or Galvanized steel wire braid (GSWB) toEN10257-1.Outer Sheath: Flame Retardant PVC (EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7IEC 60332-3Abbreviation:CU CopperPVC Polyvinyl ChlorideXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenGSWA Galvanized Steel Wire ArmorDGST Double Galvanized Steel TapeGSWB Galvanized Steel Wired BraidBasic Design (300 or 500V)IEC60331-21/BS6387Flame Retardant (Category A, B or Caccording to Request)Fire Resistance/Protocols (C W Z)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

EverprojectInstrumentation CableMulti pair/triad/quad, Individual & Overall Screen, Unarmored & Fire Resistance (Indoor Application)Cable ISCR/OSCR/PVCCU/SR/ISCR/OSCR/LSZHApplication:Fire Resistance/F&G Safe circuit cable can be used in cableladder rack or tray in the open air exposed to direct sunlight orcondute or within buildings to connect electrical instrumentationand communication circuits and industrial process controls,refineries, oil and gas plants.Operating temperature:- 15 C to 90 CCable construction:Conductor: Plain/Tinned coated annealed copper conductoraccording to IEC 60228, solid class 1 / stranded class 2 / flexible class5.Insulation: MICA Impregnated Glass Tape XLPE & FRXLPE(EN50290-2-29 /HFFR-XLPE (EN50290-2-26) or SR EI2 (EN50363-1)Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Individual screen: Aluminum backed Mylar tape (25μm) is appliedover each pair/triad/quad with an overlap of 25% with metallic sidedown in contact with a stranded tinned copper drain wire of 0.5mm²(7x0.3mm).Cabling: Required numbers of individually screened pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Recommended Installation temperature:- 5 C to 50 CCollective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of pairs/triads/quad with an overlap of 25% withmetallic side down in contact with a stranded annealed tinned copperdrain wire of 0.5mm² (7x0.3mm).Minimum Bending Radius:12 X Cable Overall DiameterOuter Sheath: Flame Retardant PVC(EN50290-2-22) / LSZH(EN50290-2-27).Reference Standards as Applicable:BS EN 50288-7IEC 60332-3Basic Design (300 or 500V)IEC60331-21/BS6387Flame Retardant (Category A, B or Caccording to Request)Fire Resistance/Protocols (C W Z)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and Conductivity (only LSZH)IEC 61034-2ICEA S-73-532/IEC60811-404UL 1581/ISO4892Low Smoke Emission (only LSZH)Oil ResistanceUV /Sunlight resistanceAbbreviation:CU CopperPVC Polyvinyl ChlorideXLPE Cross Linked PolyethyleneFRXLPE Flame Retardant Cross Linked PolyethyleneHFFR XLPE Halogen Free Flame Retardant Cross Linked PolyethyleneLSZH Low Smoke Zero HalogenISCR Individual ScreenOSCR Overall ScreenNote: On special request available:Class 1 or 2 drain wires same as conductor size or any other size.Flame retardant low smoke low halogen (LSLH) PVC.Copper Mylar Tape shielding/Annealed or Plain Copper Wire braidShielding for enhanced electrostatistical noise reduction.Vermin Impregnated, Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

Instrumentation CableSingle/Multi pair/triad/quad, Overall Screen, Braided Armored & Fire Resistance (Offshore Application)Cable construction:Conductor: Tinned coated annealed copper conductor according toIEC 60228, stranded class 2 / flexible class 5.Application:Fire Resistance/F&G Safe circuit cable can be used control,Instrumentation and propulsion circuits in ship and onmobile and fixed offshore unit.Operating temperature:- 20 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:8 X Cable Overall DiameterCable SW4/GSWB/SW4Insulation: MICA Impregnated Glass Tape EPR Type GP4 to BS7655-1.2.Twisting: Two/three/four insulated conductors are uniformly twisted toform a pair/triad/quad.Cabling: Required numbers of individually twisted pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm) is appliedover assembly of pairs/triads/quad with an overlap of 25% withmetallic side down in contact with a stranded annealed tinned copperdrain wire of 0.5mm² (7x0.3mm) to confine the electric field and to limitthe external electrical influences.Inner Sheath: Thermosetting Low Smoke Zero Halogen, Enhanced OilResistance Compound Type SW4 to BS 7655-2.6.Armor: Galvanized Steel Wire Braid (GSWB) to EN10257-1 appliedover inner sheath.Outer Sheath: Thermosetting Low Smoke Zero Halogen, EnhancedOil Resistance Compound Type SW4 to BS 7655-2.6Reference Standards as Applicable:Abbreviation:CU CopperEPR Ethylene Propylene RubberSW4 Thermosetting CompoundOSCR Overall ScreenGSWB Galvanized Steel Wired BraidBS 7917Basic Design (150/250V)IEC 60332-3IEC60331-21/BS6387Flame Retardant (Category A, B or Caccording to Request)Fire Resistance/Protocols (C W Z)ASTM D 2863-13Oxygen Index & Temperature IndexIEC 60754-1Halogen Acid ContentIEC 60754-2pH and ConductivityIEC 61034-2Low Smoke EmissionICEA S-73-532/IEC60811-404UL 1581/ISO4892Oil ResistanceUV /Sunlight resistanceNote: On special request available:Class 2 or 5 drain wires same as conductor size or any other size.Anti termite and Anti Rodent.Environmental Criteria to EN50289-4-4.

Instrumentation CableSingle/Multi pair/triad/quad, Overall Screen, Unarmored & Fire Resistance (Offshore Application)Cable ation:Fire Resistance/F&G Safe circuit cable can be used control,Instrumentation and propulsion circuits in ship and on mobileand fixed offshore tray/ladder unit.Operating temperature:- 20 C to 90 CRecommended Installation temperature:- 5 C to 50 CMinimum Bending Radius:8 X Cable Overall DiameterCable construction:Conductor: Tinned coated annealed copper conductor according toIEC 60228, stranded class 2 / flexible class 5.Insulation: MICA Impregnated Glass Tape EPR Type GP4 to BS7655-1.2.Twisting: Two/three/four insulated conductors are uniformly twistedto form a pair/triad/quad.Cabling: Required numbers of individually twisted pairs/triads/quadare assembled with non-hygroscopic filler and the assembly iswrapped with a polyester binder tape.Collective Screen: Aluminum Backed Mylar tape (25μm

IEC 60754-2 pH and Conductivity (only LSZH) IEC 61034-2 Low Smoke Emission (only LSZH) ICEA S-73-532/ Oil Resistance IEC60811-404 UL 1581/ISO4892 UV /Sunlight resistance Note: On special request available:- Class 1 o

Related Documents:

The Fireye 65UV5 flame scanner is a microprocessor-based flame scanner utilizing an ultraviolet tube-type sensor and an electro-mechanical self-checking shutter mechanism. The Fireye 65UV5 flame scanner incorporates an internal flame relay with a fixed ON/OFF threshold thereby eliminat-ing the need for an external flame amplifier.File Size: 722KB

Fireye Discrete Flame Scanners 125.00 273 Fireye Integrated Flame Scanners with Internal Flame Relay 1917.00 272 Honeywell R78 Series Flame Signal Amplifiers 269.26 266 Honeywell Flame Detectors 126.75 268 Honeywell IRIS Industrial Flame Detectors 1560.65 276 Kromschroder UVS10D2

ENARDO 4470 S. 70th East Ave. Tulsa, OK 74145-4607 1-800-336-2736 U.S. and Canada www.enardo.com FA 3 ENARDO Flame Arrestor Technology Flame Arrestor Flame Arrestor Technology Technology A Flame Arrestoris a device which allows gas to pass through it but stops a flame in ord

flame arrestor element. if the flame front is allowed to burn at the flame arrestor element, the flame arrestor could allow the flame front to pass through the element and damage equipment and/or personnel on the protected side of the arrestor. the model l76t-uf flame arrestor

butane fuel cell: 4-pack 308984 bluejet torches jet407 super cyclone flame 308407 jet408 cyclone flame 308408 jet409 triple-point flame 308409 jet410 swivel torch, concentrated flame 308410 jet411 pencil flame torch 308411 jet413 concentrated flame 308413 bluejet torch & fuel combos

OEM Direct Replacement Flame Sensors. What is a Flame Sensor? A Flame Sensor is a probe that is installed in front of a burner where a flame would burn during operation. Electric is applied to the rod from the control board. When the flame comes on and contacts the rod a DC micro-amp signal is sent back to the control board.

2. Flame-retardant Tape Flame-retardant tape is made of material which has advanced self-extinguishing properties, making it highly resistnat to flame. When subjected to strong flame, the rate of combustion is lower and spread of the burn slower than in the case of ordinary tape. UL Flame test UL 510(FR) UL 94 Title Insulating tape (FR: Flame .

vide continuous indication of flame signal, flame relay status, scanner status as well as selected mode of operation. Simplified keystroke routines are used for setup and this can be completed in seconds. For remote interface, outputs are provided for flame switch, fault relay and 4 to 20mA flame strength. CU-114 FEBRUARY 8, 2017 TYPE 85UVF/IRF