Andover ContinuumThird-Party CommunicationInterfaces and ProtocolsSchneider Electric meets today’s need for intelligent building managementsystems, (iBMS) and total integrated building control with industry-standardinterfaces, such as BACnet and OPC, plus a wide range of third partycommunications interfaces called NMPTM

02Andover Continuum Third Party CommunicationInterfaces and Protocols NMPProduct AT A GLANCE Standard Protocol Drivers Air Handling Units Battery Monitoring Systems Building Automation Systems Chillers Fire Systems Fume Hood Controls Heat Pump/Unit VentilatorsUsing either one, you can directly communicatewith third party devices in your building, such asfire panels, air handling units, chillers, variablespeed drives, video switches, and other similarequipment.The advantages of using a driver as a softwareinterface are numerous. No duplication of computerhardware or costly third party software is needed tocommunicate with the device. In addition, an AndoverContinuum workstation operator can interact directlywith the device without having to exit the softwareand then log in to a separate software interface forthe device. The ability to access the alarm and pointinformation of the third party device in the AndoverContinuum system provides a transparent “look andfeel” of an entire system all in one package.This document is designed to give an overviewof the XDrivers currently available. The drivers areorganized into general categories with descriptionsof the equipment models they interface with andtheir corresponding applications.The driver types listed are defined as:XXDriverDriver compatibility to controllers is defined by threecolumns: Intercom SystemsInfinity Compatible (SX 8000) Leak Detection Systems CX 9200 Eclipse CMX 240 Lighting Controllers Package Environmental Units Power Monitoring Programmable Logic Controllers (PLCs) Pumps Security Systems Sensors/Meters Telephone Switches/Systems UPS Systems1st Generation Andover Continuum Compatible NetController Eclipse CX 9924 CX 9200 (upgraded to be Andover Continuumcompatible)2nd Generation Andover Continuum Compatible Variable Speed Drives Video Switches Miscellaneous Drivers NetController II ACX Series Access Controllers (Models5720 & 5740) BACnet bCX1 Infinet bCX1Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

03Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Standard ProtocolsBesides the custom point-to-point interfaces listed, Andover Continuum also offers many standard interfaces designed to facilitateinteroperability among many different devices. These standard protocols include BACnet, LON, Modbus, and an OPC Server tionContinuumCompatibleSchneiderElectricXDriver FilterXE01-0210-153 BACnetEthernet IPXE01-0120-199 BACnetEthernet(Non IP)XE01-0120-197 General purpose BACnet/Ethernet interface. Conforms withthe older BACnet Standard 135-1995. This XDriver does notuse IP; it communicates using the physical Ethernet address(MAC 0-184 Acts as a gateway from an Andover CX controller to otherBACnet controllers. This product conforms to Class E01-0210-247 M-BusMeteringXE01-2010-249ModiconModbus RTUProtocolMasterVariousXE01-0210-118ModiconModbus L-OPCSRVRCTRL-OPCSRVR-USBVariousM-Bus(Please referto user guidefor testedM-BusDevices)XE01-0210-249 The M-Bus XDriver allows the exchange of meter databetween third party M-Bus devices and Andover Continuumusing the M-Bus protocol over a network. The XDriverfunctions as the M-Bus Master.XMLVariousXE01-0210-236 The XML XDriver allows a Andover Continuum 2ndGeneration controller to act as a TCP client sending XMLcommands over a TCP/IP connection. This XDriver istypically used when interfacing to CCTV equipment forcamera switching. imple serial port filter to allow non-printable characters tobe accessed by Plain English. The BACnet/IP XDriver is a general purpose BACnet/IPinterface between the CX master controllers and any BACnetcompatible device supporting ANNEX J BACnet/IP of theANSI/ASHRAE Standard 135-2001. It can be configuredas a BACnet Client or a BACnet Server and will complywith the BACnet BIBB B-ASC (BACnet Application SpecificController). The PICS statement is included in the manual. LonMark-compliant interface, used to interface to variousintelligent devices on a common bus. Requires additionalAndover interface hardware for Eclipse CX 9400 or via I/O buson Andover Continuum NetController or NetController II. Allows the exchnage of meter data between approved thirdparty M-Bus devices and Continuum using the M-Bus protocolover a serial network. Requires additional approved hardwareinterface (Westermo AD-01) to convert electrical signalsbetween RS-232 and M-Bus. Commonly used protocol supported by many PLC andequipment manufacturers. Behaves as a Master and usesPoll on demand extraction of data on an RS-232 or RS-485network. Most function codes are supported. Commonly used protocol supported by many PLC andequipment manufacturers. Uses Poll on demand extractionof data. Most function codes are supported. Software package that allows data from Andover controllersto be shared with any third party OPC-compatible clientpackage. Supports Data Access Specifications 1.0 and 2.0* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

04Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Air Handling nContinuumCompatibleDenco LtdCIU MonitrolProtocolXE01-0210-142 The CIU can connect up to 62 AHU controllerssuch as the Beta 2 Controller or Serial DataCard (SDC). Continuous polling of all data.McQuay(Snyder General)AppliedRooftopUnitsXE01-0210-182 Supports Open Protocol Data Communications(Snyder General) V1.3 or Microtech RooftopOpen Protocol V1.4. Read/Write.MammothAHU withAutomatedLogicControllersXE01-0210-118 mCompatibleXE01-0210-175 mCompatibleDriverDescriptionUse Modbus RTU XDriver for interface.Battery Monitoring SystemManufacturerNewport DataSystemsEquipment*Descrip./ModelCell WatchBatteryMonitoringDriverDescriptionFull voltage, current and internal resistanceSystems Battery Monitoring monitoring ofbattery cells, through a network of Control Unitsand Data Collection Modules.Building Automation AutomatrixPHP Sage &StarXE01-0210-121 Allows monitoring and change of data.Connects Automatrix Controllers via RS-232or up to 73 devices on RS-485.AmericanAutomatrixPUP SoloControllersXE01-0210-128 Allows monitoring and change of all Solo points.Automatrix Controllers Connects via RS-485 tomany devices (up to 65535).SchneiderElectricAC256M ,AC8XE01-0210-167 Connection to C Port allowing monitoring andsetting of all points.SchneiderElectricCXControllersXE01-0210-211 Simple serial driver to link two separate AndoverContinuum 2 Simple TCP/IP driver to link two separateAndover Continuum Systems.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

05Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Building Automation Systems mpatibleDriverDescriptionDutec DataAcquisition &Control SystemsI/O PlexorRemoteXE01-0210-198 HoneywellC-BusutilizingSoftyon I/FXE01-0210-228 HoneywellExcel 5000XE01-0210-157 Allows Honeywell system to monitor Andoverobjects using their PR – Bus protocol.JELJEL SpeakControlXE01-0210-132 Allows monitoring and change of points invarious JEL outstations, connects to 155 Allows monitoring of all points and override ofMP100 output points.TransmittonMicrotelMT700/DiDiosE01-0210-156 Allows monitoring of all points and override ofMT700/ DiDos output ible1stGenerationContinuumCompatibleAllows remote I/O configuration, control, andacquistion & monitoring of the Dutec I/O Plexerand any Control Systems attached I/O modules. Integrates Honeywell C-Bus Excel controllersinto a Andover Continuum CarrierDataport IIXE01-0210-201 Interfaces to the Carrier System by means of aCarrier Dataport II CCN CIO (CommunicationsInput/Output) Module. Allows monitoring of allCarrier chiller points.ElmRefrigerationChilled/Frozen FoodCabinetsXE01-0210-144 CX sits directly on Elm network, monitoring andchanging points as required.McQuay(Snyder 82 Supports Open Protocol Data CommunicationsV1.3 or Microtech Rooftop Open Protocol V1.4.Read/Write.TraneUCM/ RCMXE01-0210-118 TraneTracerSummit BCUXE01-0210-184 Uses Modbus RTU protocol, allows modify andpoll of all chiller data.Uses BACnet PTP (RS232) protocol.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

06Andover Continuum Third Party CommunicationInterfaces and Protocols Features t*Descrip./ModelDriverTypeKONEHLI – NetController inuumCompatibleDriverDescription The Schneider Electric Kone Xdriver interfaceacts as a gateway between the Continuumaccess control/building management systemand the High Level Interface (HLI) of the Konelift control system. The interface consists ofa Master/Slave communications protocol inwhich all traffic is controlled from the rt fordeployment.The interface system allows integrated accesscontrol for the nominated lifts. Floor access fromthe lifts is provided via card readers installed inthe operating panel of each lift car.Additionalcosts apply.Please contactSolutionsCentre UK &Ireland.OtisOtisCompassSecuritySystem ICDprotocol v2.0. E01-0210-259* Please notea WindowsServices(CCIS) is alsorequired for thisIntegration.The Continuum Otis Elevator Integrationprovides a seamless link into the Otis Elevatorsystem. All Otis Elevator user access rights andoperating modes can be managed throughContinuum. All access events and auditresponses from the Otis Elevator are processedand integrated into the Continuum Access Eventviewer and logs. The Integration comprises ofa windows service called Continuum CompassIntegration Service (CCIS)* and a ContinuumXdriver to provide a fast and robust interface.Additionalcosts apply.Please contactSolutionsCentre UK &Ireland* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

07Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Fire peFileReferenceNumberAction AirLNS SystemXAdvancedElectronicsAdvancedElectronicsFire AlarmSystemClymacZiton riverDescriptionE01-0210-238 The ActionAir LNS System consists of a PanelPC, UPS and pre-loaded software. The systemcommunicates with the smoke fire damperinterfaces (SFDI) to provide intelligent controland monitoring of ActionAir motorized dampers(Control modes).XE01-0210-261 The XDriver provides monitoring of Fire andFault conditions. It also allows several controlscommands to enable the BMS system toremotely operate the Fire system (E.g. Mute,Silence, Evacuate, Reset, Enable/Disable, etc.)XE01-0210-223 Allows monitoring of Fire Paneldata on a ZitonZP3 fire System using XDriver points in AndoverContinuum. The XDriver may monitor Alarm,Fault, Enabled/Disabled conditions on individualDevices Zones or Loops in the Ziton Fire System.XE01-0210-231 Provides a link between Andover Continuum anda network of Cerberus fire panels monitoring ofa Cerberus fire alarm system from the AndoverContinuum front-end.InfinityCompatible 1stGenerationContinuumCompatible EdwardsFast PanelIRC-3XE01-0210-189 Requires CM1N control module with printer port.EdwardsEST-3 PrinterProtocolXE01-0210-221 Operates through the EST-3 printer interfaceto allow monitoring of Fire Panel. It allows themonitoring of detectors such as Alarms, Faults,Disablements and Enablements.GamewellISeries 600Analog/AddressableFire AlarmControl PanelXE01-0210-193 Gent3400 PanelXE01-0210-152 GentVigilonXE01-0210-248 The Gent XDriver provides an interface betweenAndover Continuum and Gent Vigilon fire alarmpanels. This allows Andover Continuum users tomonitor the alarm and fault status and performsome basic control functions, such as resettingand silencing alarms.HoneywellNotifierNotifierID3000panels instandaloneor ID2 peerto-peernetworksXE01-0210-243 The XDriver allows the monitoring of alarms,faults, disablements and system information fromthe Notifier panel and is able to send controlcommands (Reset, Accept, Silence, Evacuate,etc.).How/FaceMacandaProton PanelXE01-0210-143 Allows remote acknowledgment, silence, andreset actions, as well as remote monitoring ofalarm and fault conditions from the panel, itscircuits, and devices. Supports both a singlepanel and networked panel.Uses both Plain English and XDriver filter to mapall points from Fire Panel.Monitor only, will need modifications for AndoverContinuum as it contains data files.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

08Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Fire Systems mpatibleKentecKentechSyncro PanelXE01-0210-216 This enables a stand alone Kentech panel, ornetwork of panels to be integrated into AndoverContinuum, allowing fire and fault 2 This XDriver may monitor alarm, fault, enable/disable conditions on individual zones or loopsin the Protec Fire System. The latest version canlink directly to the Pelco Endura XDriver for fastcause & effect actions.Simplex4020, 4100,4120XE01-0210-186 Uses Simplex 4100 Computer Port Protocol –Format 1.Simplex4020, 4100,4120 SeriesXE01-0210-184 TycoTyco MXXE01-0210-226 Integrates Andover Continuum with TycoMX Fire Panels in a network environmentand simulates a Fire Panel Node on the Tyconetwork. Changes in device or panel status aremapped across to the NetController.VesdaMini, ED-70,ScannerXE01-0210-118 Uses Modbus interface to map all smokeScanner detection system ontinuumCompatibleDriverDescriptionUses BACnet PTP/RS-232 to communicatethrough a Simplex BACpac Portal tocommunicate to the Simplex fire control panel.Read only.Fume Hood DescriptionPheonix ControlsCelerisSystemXE01-0210-197 Uses BACnet-over-Ethernet to communicate toa Celeris system through a Phoenix Accel-Way.Read/Write.Tek AirFVC-2000XE01-0210-140 Allows monitoring & control of the LaboratoryFume hoods.Heat Pumps/Unit rationContinuumCompatibleMcQuay(Snyder General)Water SourceHeat PumpXE01-0210-182 upports Open protocol Data CommunicationsV1.3 or Microtech Rooftop Open protocol V1.4Read Write.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

09Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Intercom ypeFileReferenceNumberAlphacomAlphacom 80ExchangeXE01-0210-122Complus CompatibleDriverDescription Allows the monitoring of call log data on aAlphacom 80 Exchange System using XDriverpoints in Continuum, its display in a ContinuumEvent Viewer and the Continuum database. The Complus Teltronic XDriver providesmonitoring of Intercom calls from any ComplusTeltronic calling station (e.g. building entrance,car parking barriers, etc.), and a call history log.It can be effectively used to build a cause andeffect scenario triggered by the intercom calls(e.g. switching CCTV cameras, turn on lights,start programs, etc).DriverDescriptionLeak Detection SystemsManufacturerVeeder- ibleXE01-0210-178 Monitors system status, alarms tank levels, intank inventory, and system resets.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

10Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Lighting umCompatibleDriverDescriptionApexLightingsystemvia ApexSpectrumManagerWebService.XE01-0210-258 The Apex Xdriver issues http web request to periodically pollinformation from the outputs, Lighting Control Modules (LCM)devices, Emergency devices and Controller status.Clipsal5100PC5500PCXE01-0210-230 Allows connection to a Clipsal C-Bus lighting system via aserial RS-232 interface, enabling reading from and writingto points on the system and continuous notification of pointstatus or value change.DelmaticZMC SeriesXE01-0210-145 Programs to control: Load Shedding, Emergency Test,Automatic Timing, Automatic Timing for staircases, CentralSwitching E01-0210-176 Monitor and control lighting levels.ProlojikProlojik ionContinuumCompatible The Prolojik Xdriver acts as an http Web Client to poll dataform the Prolojik Web Service and feeds data into Continuumobjects. It allows the monitoring of device status and zoneoccupancy point information.Package Environmental ntinuumCompatibleXE01-0210-118 DriverDescriptionUses Modbus RTU XDriver* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

11Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Power rationContinuumCompatible Cummins ringXE01-2010-249Northern DesignAbacus IIXE01-0210-146 Russ Electric90-30XE01-0210-118 Square DPower logicCircuitMonitorXE01-0210-187 VerisPowerMetersH8035,H8036XE01-0210-118 Westinghouse/Cutler HammerIMPACC IQMetersXE01-0210-158 nables full control and monitoring of a Cummins DieselGenerator Set, including alarms. Allows the exchnage of meter data between approved thirdparty M-Bus devices and Continuum using the M-Busprotocol over a serial network. Requires additional approvedhardware interface (Westermo AD-01) to convert electricalsignals between RS-232 and M-Bus.XDriver & Plain English code to monitor power readings.Plain English contains data files and is not AndoverContinuum-compatible. Uses Modbus RTU Protocol to map data. Uses StandardSY/ MAX XDriver. Monitors power, voltages, currents,phase etc., on all circuits.Uses Standard SY/ MAX XDriver. Monitors Circuit Monitorpower, voltages, currents, phase etc., on all circuits. Uses Modbus RTU XDriver.Allows monitoring and adjustment of all points.Programmable Logic Controllers bleDriverDescriptionJ Bus ProtocolVariousXE01-0210-118 The J Bus protocol is a subset of the Modbusprotocol and so the Modbus XDriver is used forJ Bus Systems.ModiconModbus RTUProtocolVariousXE01-0210-118 Commonly used protocol supported by manyPLC and equipment manufacturers. Uses Poll ondemand extraction of data. Most function codesare VariousXE01-0210-162 Polls & changes data asynchronously to thescan. Supports all functions as standard versionabove.Square DSY/MAXPLCsXE01-0210-187 Uses Standard SY/ MAX XDriver.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

12Andover Continuum Third Party CommunicationInterfaces and Protocols Features crip./ModelGenibusPumps ible1stGenerationContinuumCompatibleXE01-0210-172 ull control and monitoring of pumps and motorson RS-485 Genibus network.Security ntinuumCompatibleDriverDescription The Comerson XDriver allows a Continuum 2ndGeneration controller to send Net Alarms to aComerson Digital CCTV System (CDS). This Xdriver is used to pass custom messages fromthe Plain English environment to the ContinuumAccess engine to create Valid and Invalid attemptswith or without custom messages. The ELMO XDriver allows the integration of the ELMOIntruder Alarm system within the Andover ContinuumBuilding Management System.The integration is handled at controller level, providinga robust and fast event processing.Controls command can be sent from the BMS systemto operate within the Alarm system (E.g. Arm/DisarmZones, Output on/off, Disable inputs, etc.)ComersonComersonDigitalSystemCustom Access Schneider MOAlarm panel(v2 protocol)E01-0210-263GuardallPX. WindsorPanelsXE01-0210-177 3 ScopeCommunicationsScope RX 10IntruderSystemXE01-0210-220 eterIntrusionDetectionSystemXE01-0210-246 The Microtrack XDriver allows the integration of theMicrotrack “Intrepid” MTP (Buried cables perimeterintrusion system) within the Andover ContinuumSystem.Static SystemsIP FusionNurse calland FireAlarmSystemXE01-0210-252 The Schneider Electric IPFusion TCP/IP xdriverallows Continuum to receive live events fromthe Static Systems Group IPFusion router andunderlying system which consists of Nurse Call andFire System. Set/unset areas, isolate/de-isolate and monitoralarm and tamper conditions for all detectors. Allows the User to set, unset, partset and resetgroups, reset the panel, monitor conditions ofcircuits; and monitor, set, and alarm conditions ofgroups. The latest version can link directly to thePelco Endura XDriver for fast cause & effect actions.Provides a link between Continuum and the ScopeRX10 programmable POCSAG receiver. This allowsalarm data sent from an IRIS (Intelligent RadioInformation System) to a Scope RX10 to be capturedas alarms and events in Continuum.* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

13Andover Continuum Third Party CommunicationInterfaces and Protocols Features t*Descrip./ModelAEA 01-0210-192 GenerationContinuumCompatibleXE01-0210-188 mCompatibleDriverDescriptionXE01-0210-118 Modbus RTU is used to extract data from theMGE units. Note: The Comet UPS actually usesJBUS which is a smaller set of Modbus tionContinuumCompatibleDriverDescription Uses Modbus RTU protocol to extract data fromindividual drives.Part of a MAGLINE micro Linear PositioningSystem. Has an MSA Sensor to sense theposition along a magnetically-encodedmeasuring strip.Telephone scriptionSupports TBOS Protocol.UPS SystemsManufacturerMGE UPSEquipment*Descrip./ModelComet UPSVariable Speed 0XE01-0210-118 DanfossVTL3000SeriesXE01-0210-131 Gives full control & monitoring of all driveparameters* These options are available to download from Buildings Business Extranet. The appropriate XDriver comm port must be enabled on the controller.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildings

14Andover Continuum Third Party CommunicationInterfaces and Protocols Features (continued)Vehicle ManagementManufacturerScheidt patible E01-0210-262DriverDescriptionThe VMS - Scheidt & Bachmann XDriver allowsthe integration of the Scheidt & BachmannEntervo Server within the Andover Continuumsystem.The integration is handled at controller level,providing a robust and fast event processing.The XDriver provides fault monitoring of variousdevices (eg Car park barriers, Pay on Footmachines etc) connected to the Entervo server.Miscellaneous nt*Descrip./ModelTMS le1stGenerationContinuumCompatibleXE01-0120-168 onitors traffic sign data and alarms.All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to changewithout notice.Schneider Electric One High Street, North Andover, MA 01845 phone: 1 978 975 9600Fax: 1 978 975 9674www.schneider-electric.com/buildingsOctober 2012 2009 - 2012 Schneider Electric. All rights reserved* These options are available to download from Buil

McQuay (Snyder General) Applied Rooftop Units X E01-0210-182 Supports Open Protocol Data Communications (Snyder General) V1.3 or Microtech Rooftop Open Protocol V1.4. Read/Write. Mammoth AHU with Automated Logic Controllers X E01-0210-118 Use Modbus RTU XDriver for interface. Air H

Related Documents:

Internal Interfaces behave as regular layer 2 interfaces. No OTV configuration is needed on the OTV Internal Interfaces. Typically these interfaces are configure as Layer 2 trunks carrying the VLANs to be extended across the Overlay. OTV Internal Interface OTV Internal Interfaces OTV Internal Interfaces

builders, and general contractors of the development. The Toll defendants commenced the third party action by third-party complaint dated July 1, 2009. Thereafter, third-party defendant A.P. Roofing & Siding (hereinafter "A.P.") commenced the second third-party action and third thi

3. Sets forth the scope of Third Party Inspections and clarifies the documentation and reports that must be completed by each participant in the process, including the owner of the property subject to a building permit, the Third Party Inspection Agency, the Professional- in-Charge, the Third Party Inspector and the Department.

The Definitive Guide to Third-Party Risk Management is a comprehensive resource full of insight, advice and examples to help organizations recognize and address their third-party risk. A strong third-party risk management program will help your organization make smart choices when it comes to engaging with business partners.

products or services from a third party, the relati onship is directly between you and the third party. Oracle is not responsible for: (a) the quality of third-party products or services; or (b) fulfilling any of the terms of the agreement with the third party, including delivery of

5. www.theiia.org Auditing Third-party Risk Management After reading this guidance, internal auditors will be able to: Understand key roles, responsibilities, and risks related to managing an organization's third- party providers. Appropriately assess third-party risk management activities across the first-line business, oversight, and control functions.

MS-NIE2916- 9.0 » 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one N2 Bus. The number of supported devices on the third-party trunk depends on the protocol. For the N2 Bus, up to 32 devices are supported. Includes integral display screen. MS-NIE2920- 9.0 only Supports two third-party trunks (Modbus RTU or TCP .

Financial risk Risk that the third party cannot continue to operate as a financially viable entity Regulatory and compliance risk Risk that a third party fails to comply with a required regulation, thus causing the organization to be out of compliance Digital risk Risk that is associated with the third party's digital business processes