BEH New Generation "D"Condensing Units PRODUCT DATA &SPECIFICATIONSIndoor/Outdoor Air-CooledHermetic Condensing UnitsBulletin B40-BEHD-PDS-4Part # 1108866PRODUCT SUPPORTweb: www.b-rp.ca/behemail: smcu@b-rp.cacall: 1-844-893-3222 x5211/2 to 3.5 HP -Medium and LowTemperature Refrigerationscan:Indoor UnitSee Page 4 for detailsOutdoor UnitCONTENTSPageNomenclature. 2Features, Options and Pre-Selected Option Packages. 2 - 3Fan Motor Technology . 4Capacity Data (Imperial and Metric). 5 - 8Electrical Data.910Annual Walk-In Energy Factor (AWEF) Ratings.Dimensional Data. 11 - 13Specifications. 13Wiring Diagrams. 14 - 1617Wiring Diagrams - Models with.19Project Information.Product Support Resources. BACK28/10/20

BEH - HERMETIC CONDENSING UNITSNOMENCLATUREBEH AModel SeriesBEH Excel Hermetic Air CooledCondensing Unit LineCompressor ManufacturerA CopelandNominal HP005 - 035 1/2 - 3.5 HPApplication RangeM Medium TempL Low TempRefrigerant*6 R404A / R5078 R404A / R407A / R448A / R449A010 M 8 - HT3 D - APre-Selected Factory Mounted Option PackagesSee detail on next pageDesign GenerationD Latest Catalog SeriesVoltage*S2 208/230-1-60S3 230-1-60S6 200/220-1-50S7 200-1-50T3 208/230-3-60T4 460-3-60T5 575-3-60T7 200/220-3-50T9 380/400-3-50* subject to compressor availabilityEnclosureH OutdoorI IndoorSTANDARD FEATURESIndoor Unit: Receiver with fusible plug and liquid shut off valveWeatherproof electrical control box with Suction service valvecompressor contactor and fused control circuit Copper tubing secured with cushion clampsWelded-hermetic compressorHigh efficiency enhanced tube and fin condenser design Fixed high and adjustable low pressure controlPre-formed pipingQuiet fan motor operationSmartSpeed EC Fan Motor Technology standard onOutdoor Unit: All Standard Features of Indoor Unit,models using chassis 1 and 2 (see page 13)Plus:Energy efficient PSC condenser fan motor on models Painted weather-resistant housingusing chassis 3 (see page 13)with removable hoodElectrical control panel away from air flow stream Flooded head pressure control (adjustable)Unit leak tested and shipped with helium holding charge Crankcase heaterPainted cabinetAVAILABLE OPTIONS Sealed suction filterSuction accumulatorSuction accumulator with boil-out coilHeated and insulated receiverSealed liquid line filter drier and sight glassLiquid line solenoid valve with 230-volt coil(shipped loose)Compressor circuit breakerCompressor time delay relayVariable speed EC motors as headpressure control (see Bulletin B40-HPC-AGor https://docs.b-rp.ca/1101112.pdf for details)QuickVac Evacuation and RefrigerantRecovery Valves SmartSpeed Fan Motor Technology on models using chassis3(see page 13) Pump down toggle switch Electric defrost kit with mechanical time clockand contactors, as required Lockout control circuit relay (for liquid solenoid valve) Disconnect switch (fused or non-fused) Electronic phase / voltage monitor Leg kit or air discharge hood

PRE-SELECTED FACTORY MOUNTEDOPTION PACKAGESGOODBEH - HERMETIC CONDENSING UNITSFor High / Moderate AmbientsFor Moderate / Low AmbientsPackage B:Package D:Package N:Package J: Liquid Line Filter Drier1 & Sight GlassBETTER Liquid Line Filter Drier1 & Sight Glass Heated and Insulated Receiver Liquid Line Filter Drier1 & Sight Glass Suction Accumulator w/o Heat ExchangerBEST Liquid Line Filter Drier1 & Sight Glass Suction Accumulator w/o Heat Exchanger Heated and Insulated ReceiverPackage P:Package Q: Liquid Line Filter Drier & Sight Glass Suction Accumulator w/o Heat Exchanger Suction Filter2 Non-Fused Disconnect Liquid Line Filter Drier1 & Sight Glass Suction Accumulator w/o Heat Exchanger Suction Filter2 Non-Fused Disconnect Heated and Insulated Receiver112Liquid Line Filter Drier: Sealed on ALL One Fan Model Units, Replaceable on ALL Two Fan Model Units.Suction Filter: Sealed on ALL One Fan Model Units, Replaceable on ALL Two Fan Model Units.For information on Evaporator Defrost Kits and Fuse Packages, visit www.b-rp.ca/dfkRECOMMENDATIONS FOR SELECTINGFACTORY MOUNTED OPTION PACKAGESAKYTNTNUNLNLBCABModerate / Low AmbientsPENBSKQCNSMBFor Moderate /Low Ambients:Good: Package DBetter: Package JBest: Package IPAWYINWVVAKYMONHMARINCDEFor High /Moderate Ambients:Good: Package BBetter: Package NBest: Package PTNOKAZSCARNMMSALGALATXHIHigh / Moderate AmbientsFLFor further details, visit our website and seeApplication Bulletin BAB-0101-02-1:"About Heated And Insulated Receivers"or contact your local sales representative.

BEH - HERMETIC CONDENSING UNITSAVAILABLE OPTIONSUS Patent No.9,297,567DESIGN FEATURES Standard on models using chassis 1 and 2 (optional on chassis 3) No special controls required. No worries about wind or cold climates. Ambients above 55 F - EC motor operates at full speed, crankcase heater andheated insulated receiver disabled from control circuit Ambients below 55 F - EC motor operates at low speed, crankcase heater andheated insulated receiver enabled from control circuitCondensingUnitEER - StandardUnit vs.SmartSpeedSmartSpeedCondensingUnit EER- Standardvs. KeepRite121115 %*10EER eedSmartSpeed76* BIN ANALYSIS SHOWS AN AVERAGE OF 10%SAVINGS OVER THE RANGE OF THE YEAR5INSTALLATION NOTES4120100806040200-20-40AMBIENT (⁰F)Refer toPages 17For Wiring DetailsB30-BEHD-PDI-4Condensing Unit with SmartSpeedPower Consumption Per MotorChassis Size(see pages12 - 13)Ambients above 55 F.Fan Full Speed.Crankcase and ReceiverHeaters Off.Ambients below 55 F.Fan Low Speed.Crankcase and ReceiverHeaters On.1102 W19 W2168 W37 W3362 W76 W-4-28/10/20

BEH - HERMETIC CONDENSING UNITSSELECTION CAPACITY DATAR404A R507 Medium S20K6EB30-BEHD-PDI-4SaturatedSuctionTemperature F C404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8404.4351.730-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8Selection Capacity BTU/h Ambient Temperature85 F(29.4 00205001810090 F(32.2 192001690095 F(35 1790015700100 F(37.8 60014500105 F(40.6 013300-5-110 F(43.3 1210028/10/20

BEH - HERMETIC CONDENSING UNITSSELECTION CAPACITY DATAR407A Medium e F C30-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8Selection Capacity BTU/h Ambient Temperature85 F(29.4 02260019800171001460090 F(32.2 02140018600160001360095 F(35 20200175001500012600100 F(37.8 900164001390011500105 F(40.6 0153001290010600110 F(43.3 4100119009550NOTE: Mean temperature is the average temperature between the saturated suction vapor temperature (dew point) and the temperature feeding the evaporator.To be consistent with the evaporator selection method, Mean rating capacities are recommended.B30-BEHD-PDI-4-6-28/10/20

BEH - HERMETIC CONDENSING UNITSSELECTION CAPACITY DATAR448A R449A Medium re F C30-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.830-1.125-3.920-6.715-9.410 -12.25 -15.00 -17.8Selection Capacity BTU/h Ambient Temperature85 F(29.4 018500160001360090 F(32.2 7400150001270095 F(35 63001400011900100 F(37.8 001310011000105 F(40.6 01230010200110 F(43.3 14009560NOTE: Mean temperature is the average temperature between the saturated suction vapor temperature (dew point) and the temperature feeding the evaporator.To be consistent with the evaporator selection method, Mean rating capacities are recommended.B30-BEHD-PDI-4-7-28/10/20

BEH - HERMETIC CONDENSING UNITSSELECTION CAPACITY DATAR404A R507 Low ctionTemperature F C0 -17.8-5 -20.6-10 -23.3-15 -26.1-20 -28.9-25 -31.7-30 -34.40 -17.8-5 -20.6-10 -23.3-15 -26.1-20 -28.9-25 -31.7-30 -34.40 -17.8-5 -20.6-10 -23.3-15 -26.1-20 -28.9-25 -31.7-30 -34.40 -17.8-5 -20.6-10 -23.3-15 -26.1-20 -28.9-25 -31.7-30 -34.40 -17.8-5 -20.6-10 -23.3-15 -26.1-20 -28.9-25 -31.7-30 -34.4Selection Capacity BTU/h Ambient Temperature85 F(29.4 90 F(32.2 5 F(35 12060905110421015900142001250010900934078606470100 F(37.8 1056404720387014900133001170010200870072905990105 F(40.6 0 F(43.3 /20

BEH - HERMETIC CONDENSING UNITSELECTRICAL DATAStandard ModelsCompressorModel No.Model 0.36.315.09.24.9Condenser Fan M †ECM †ECM †ECM †ECM †PSCPSCPSCPSCPSCPSCPSCPSCPSCECM †ECM †ECM †ECM †ECM †ECM †ECM †ECM †ECM †ECM 52015352015* I Indoor, H Outdoor. ** 460V Units utilize a 230V EC motor with transformer †EC Motor StandardAbove listed RLA value is based on UL rating method and may differ from published compressor RLA data.Models with OptionalCompressorModel No.Model 20K6E-PFVCS20K6E-TF5EC 0Condenser Fan 035204025* I Indoor, H Outdoor. Above listed RLA value is based on UL rating method and may differ from published compressor RLA data.B30-BEHD-PDI-4-9-28/10/20

BEH - HERMETIC CONDENSING UNITSAWEF RATINGSAnnual Walk-In Energy Factor Ratings - High/Medium TemperatureIf a numerical value is listed in the table below, the following statement applies to that corresponding model: " This refrigeration systemis designed and certified for use in walk-in cooler applications.”Outdoor ModelsIndoor ModelsUnitModelBEHR404A R507R407AR448A R449AR404A R507R407ABEHA006M8- * S2DBEHA015M8- * S2DBEHA015M8- * T3DBEHA015M8- * T4DBEHA020M8- * S2DBEHA020M8- * T3DBEHA025M8- * S2DBEHA025M8- * T3DBEHA025M8- * T4DBEHA030M8- * S2DBEHA030M8- * T3DBEHA030M8- * T4DBEHA035M8- * S2DBEHA035M8- * T3DBEHA035M8- * 5.615.615.615.615.615.61— Non-compliant modelAnnual Walk-In Energy Factor Ratings - Low TemperatureIf a numerical value is listed in the table below, the following statement applies to that corresponding model: " This refrigeration systemis designed and certified for use in walk-in freezer applications.”Outdoor ModelsIndoor ModelsBase UnitModelBEHR404A R507R407AR448A R449AR404A R507R407AR448A R449ABEHA008L6- * S2DBEHA010L6- * S2DBEHA010L6- * T3DBEHA015L6- * S2DBEHA015L6- * T3DBEHA020L6- * S2DBEHA020L6- * T3DBEHA025L6- * S2DBEHA025L6- * .192.172.192.18---— Non-compliant modelB30-BEHD-PDI-4- 10 -28/10/20

DIMENSIONAL DATABEH - HERMETIC CONDENSING UNITSDrawing A: 1 Fan Models, Chassis 1 and 2AIRFLOWINDOOR DIMENSIONSAIRFLOWOUTDOOR DIMENSIONSNOTE: Discharge hood, legs and wind guard are optional componentsREFER TO PAGE 13 FORDIMENSIONAL DATA FOR SPECIFIC MODELSB30-BEHD-PDI-4- 11 -28/10/20

DIMENSIONAL DATABEH - HERMETIC CONDENSING UNITSDrawing B: 1 Fan Models, Chassis 3AIRFLOWINDOOR DIMENSIONSAIRFLOWOUTDOOR DIMENSIONSNOTE: Discharge hood, legs and wind guard are optional componentsREFER TO PAGE 13 FORDIMENSIONAL DATA FOR SPECIFIC MODELSB30-BEHD-PDI-4- 12 -28/10/20

DIMENSIONAL DATAModelBEH - HERMETIC CONDENSING 020L6BEHA025L6(seedetailsbelow)12312Outdoor ModelsDepthWidthInches24 7/836 3/836 3/843 7/843 7/843 7/824 7/824 7/824 7/824 7/836 s30 3/830 3/830 3/832 7/832 7/832 7/830 3/830 3/830 3/830 3/830 3/8Indoor ModelsHood, add:mm772772772835835835772772772772772Inches34 3/834 3/834 3/843434334 3/834 3/834 3/834 3/834 3HeightInches19 3/819 7/819 7/830 3/830 3/830 3/819 3/819 3/819 3/819 3/819 dthInches24 5/836 1/836 1/843 7/843 7/843 7/824 5/824 5/824 5/824 5/836 es30 3/830 3/830 3/832 7/832 7/832 7/830 3/830 3/830 3/830 3/830 1919 1/219 1/230 3/1630 3/1630 3/161919191919 1/2mm483495495767767767483483483483495See Page #111112SPECIFICATIONSModelBEHUnit ConnectionsSuction (OD)InchesApprox. Shipping WeightR404ALiquid (OD)mmInchesmmReceiver Capacity90% Full *Outdoor ModelsLbs.KgsLbs.Indoor 7/8223/81014.46.53281127254115B30-BEHD-PDI-4- 13 -28/10/20

WIRING DIAGRAMSBEH - HERMETIC CONDENSING UNITS208-230/1/60 UnitB30-BEHD-PDI-4- 14 -28/10/20

BEH - HERMETIC CONDENSING UNITSWIRING DIAGRAMS208-230/3/60 UnitB30-BEHD-PDI-4- 15 -28/10/20

BEH - HERMETIC CONDENSING UNITSWIRING DIAGRAMS460/3/60, 575/3/60 UnitsB30-BEHD-PDI-4- 16 -28/10/20

WIRING DIAGRAMS208-230/1/60 Unit withB30-BEHD-PDI-4BEH - HERMETIC CONDENSING UNITSwith 230V Air Defrost Evaporator- 17 -28/10/20

NOTESB30-BEHD-PDI-4BEH - HERMETIC CONDENSING UNITS- 18 -28/10/20

PROJECT INFORMATIONBEH - HERMETIC CONDENSING UNITSSystemModel NumberDate of Start-UpSerial NumberService ContractorRefrigerantPhoneElectrical SupplyE-MailB30-BEHD-PDI-4- 19 -28/10/20

PRODUCT SUPPORT RESOURCESBEH - HERMETIC CONDENSING UNITSweb: www.b-rp.ca/behemail: smcu@b-rp.cacall: 1-844-893-3222 x521email: troubleshooting@b-rp.cacall: 1-844-893-3222 x529web: www.b-rp.ca/partsemail: parts@b-rp.cacall: 1-844-893-3222 x521web: www.b-rp.ca/warrantyemail: warranty@b-rp.cacall: 1-844-893-3222 x507email: orders@b-rp.cacall: 1-844-893-3222 x501email: shipping@b-rp.cacall: 1-844-893-3222 x503DISTRIBUTED BY:Bally RefrigerationMorehead City, NC Brantford, ON Longview, TX1-800-242-2559 ballysales@ballyrefboxes.com www.ballyrefboxes.comDue to the manufacturer’s policy of continuous product improvement, we reserve the right to make changes without notice.28/10/20

Standard Unit KeepRite SmartSpeed 15 %* * BIN ANALYSIS SHOWS AN AVERAGE OF 10% SAVINGS OVER THE RANGE OF THE YEAR Condensing Unit EER - Standard Unit vs. SmartSpeed. Standard Unit: SmartSpeed. Condensing Unit with SmartSpeed : Power Consumption Per Motor

Related Documents:

PF Prop Fan Condensing Unit A P 208/230V, 1 ph, 60 Hz C C Standard Condensing Unit X 277V, 1 ph, 60 Hz H Hot Gas Bypass S 220/240V, 1 ph, 50 Hz 18A 020A 1.5-ton Condensing Unit A 460V, 3 ph, 60 Hz 027A 2-ton Condensing Unit Y 208/230V, 3 ph, 60 Hz 037A 3-ton Condensing Unit

twc 18 18,000 btuh 1 1 phase condensing series louvered 10 seer ckl 18 18,000 btuh 1 1 phase condensing louvered 12 seer clj 18 18,000 btuh 1 1 phase condensing series t 13 seer crt 24 24,000 btuh condensing louvered 13 seer clt 24 24,000 btuh 1 1 phase condensing louvered 14 seer clq 24 24,000 btuh 1 1 phase

The condensing unit must be installed on a solid, level mounting pad that will not settle or shift. Isolate the pad from the building structure to avoid possible transmission of sound or vibration from the condensing unit into the conditioned space. The condensing unit foundation should

Condensing Unit, the minimum distance between the Control Panel and the wall is 3 feet. On Indoor Condensing Unit, Satellite Unit, Remote Condenser Unit and Water Cooled . Condensing Unit, the minimum distance between the Control Panel and another live panel is 4 feet

Condensing Unit EER - Standard vs. KeepRite SmartSpeed Standard Unit KeepRite SmartSpeed 15 %* * BIN ANALYSIS SHOWS AN AVERAGE OF 10% SAVINGS OVER THE RANGE OF THE YEAR Condensing Unit EER - Standard Unit vs. SmartSpeed Standard Unit SmartSpeed Condensing Unit with SmartSpeed Power Consumption Per Motor Chassis Size

Condensing Unit EER - Standard vs. KeepRite SmartSpeed Standard Unit KeepRite SmartSpeed 15 %* * BIN ANALYSIS SHOWS AN AVERAGE OF 10% SAVINGS OVER THE RANGE OF THE YEAR Condensing Unit EER - Standard Unit vs. SmartSpeed Standard Unit SmartSpeed Condensing Unit w

Condensing Unit Air Cooled Centrifugal Condensing Unit Water/Glycol Condensing Unit 3 Tons 60 Hz (50 Hz) B*036E (B*035E) PFH_42A (PFH_41A) MC_40A (MC_39A) MC_44W . Figure 20 Cabinet and floor planning dimensions—Split system 5 ton outdoor condensing u

The book normally used for the class at UIUC is Bartle and Sherbert, Introduction to Real Analysis third edition [BS]. The structure of the beginning of the book somewhat follows the standard syllabus of UIUC Math 444 and therefore has some similarities with [BS]. A major difference is that we define the Riemann integral using Darboux sums and not tagged partitions. The Darboux approach is .