Next PageReturn to LiteratureTMR O O F T O PUNISTRUTDINSTW A L K W A Y SESIGNALLATGUIDEION

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SRooftop maintenance trips are a com-access to rooftop equipment andmon occurrence. This is especially so forfixtures. ROOFWALKS distribute weightmost business and industrial buildingsloads “evenly”, and install without roofequipped with fans, blowers and exhaustpenetration. This permits workers tounits mounted on their roofs.walk “safely” on an anti-skid surfacePeriodic checks of these rooftop unitswith no seam distortion or excessiveWalkwaysprovide the opportunity for accidentalstress to the roof.roof panel damage due to foot traffic.Installing a ROOFWALKS Rooftop WalkwayThat ProtectStanding-seam roofs, along with built-system will help prevent an accident wait-up roofs and single-ply membrane roofs,ing to happen. They prevent roof leaksall present certain problem areas forfrom occurring -PLUS- provide for work-roof leakage, damage and safety haz-er’s safety with a “visible sidewalk.”ards for workers.Field tested and proven for over a decade.Potential problems can be avoided withROOFWALKS rooftop-walkways arethe installation of a Unistrut ROOFWALKS simply the best for product value andRooftop walkway system. The uniqueperformance.ROOFWALKS Sure-FootedPersonneland Roofs!UNISTRUTsupport system allows convenientROOFWALKS For Metal Standing-Seam Roofs2ROOFWALKS For Built-up, Membrane, Foam Or Coated Roofs Copyright 1995, Unistrut Corporation. ROOFWALKS is the registered trademark of Unistrut Corporation.

Previous PageNext PageReturn to LiteratureTMR O O F T O PUNISTRUTW A L K W A Y SIISERIESCONTENTSQUICK REFERENCE GUIDEBuilding Manufacturers Listed in Reference Groups for Installation DetailsPAGEIntroduction ofROOFWALKS . . . . . . . . . . . . . . . . . . . .2Roof Styles:Manufacturer Group Guide . . . . . . . . . .3Product Information . . . . . . . . . . . . . .4-5Generic Standing-SeamRoof Profiles & Descriptions . . . . . . . . .5How To Plan a ROOFWALKS Walkway System . . . . . . . . . . . . . . . . . . . . . . . . . .20METAL STANDINGSEAM ROOFSways are designed to be versatile and maybe adapted to all types of metal standingseam roof systems. Unique installation system has eliminated any need for roofGroup Dpenetration*.Group ASpecifications: ROOFWALKS . . . . . . . .21Warranty Information . . . . . . . . . . . . .22 STANDING-SEAM SECTIONGroup “A”: Sales,Installation, Parts Guide . . . . . . . . .6-7Group “B”: Sales,Installation, Parts Guide . . . . . . . . .8-9Group “C”: Sales,Installation, Parts Guide . . . . . . .10-11Group “D”: Sales,Installation, Parts Guide . . . . . . .12-13Group “F”: Sales,Installation, Parts Guide . . . . . . .16-17Stran BuildingsAll Unistrut ROOFWALKS Rooftop Walk-Example Installation Plan . . . . . . . . . . .21Group “E”: Sales,Installation, Parts Guide . . . . . . .14-15Group C Group BAmerican BuildingAtlantic BuildingA.S.C. PacificButler BuildingCeco BuildingCarlisleGulf StatesMesco BuildingMetal Sales Inc.Morin CorporationM.B.C.I.Nucor BuildingStar BuildingU.S.A. BuildingVarco PrudenWedgcore Inc. BuildingGroup EGroup FPascoe BuildingSteelite BuildingInland BuildingChief IndustriesFabral Building(All)Rib RoofConstruction,12-inch O.C.*BUILT-UP ANDPREFABRICATEDMEMBRANE ROOFS(FLAT DESIGN)Group GA&S Building SystemInland BuildingSteelox BuildingSummit BuildingBuilt-up RoofsElastomericMembrane RoofsModified Bitumen Membrane RoofsUrethane Foam RoofsCoated Roofing Systems MEMBRANE ROOFTOP SECTIONGroup “G”: Sales,Installation, Parts Guide . . . . . . .18-19For special roof manufacturers not listed above please see page 5 of this guide.* Roof penetration may be required on some rib-roof designs.3

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SGENERAL INFORMATIONROOFWALKS SystemsThat InstallOn TypicalPROTECTION FROM ROOFTOP TRAF-elements to each system: (1) steel plankFIC! Over time, pedestrian foot traffic ongrating, (2) special hardware clips, andstanding seam metal roofs can compro-(3) support plates that bolt directly tomise roof integrity. Recognizing thisthe standing-seams. The unique designproblem, many designers avoid specify-of the ROOFWALKS anchoring clips forming rooftop replacement of HVAC anda nearly perfect match with the standing-other equipment to reduce the need forrooftop access. Eventually someone willbe climbing out on to those roofs to getto something. This can increase the possibilities for damage and accidents. Dishing and punctures could cause leaks andlead to expensive repairs.Standing-SeamDesign Roofs.ROOFWALKS Rooftop Walkways. . .The right solution to rooftop pedestrianfoot traffic. Designers may now choose tolocate fixtures, exhausts and other equipment on the roof for a wider range ofaesthetic and functional building design.ROOFWALKS are custom-designed forseams of most roof manufacturers. Foreasy installation for more than 20 of theparallel applications, special hold downmost popular metal standing-seamclips attach the plank grating to a seriesdesigns. These walkways permit rooftopof support plates that span the standing-workers to walk safely on an anti-skid sur-seams.face without causing seam distortion orANTI-SKID PROTECTION! Galvanizedexcessive stress to roof panels.plank grating features a surface thatROOFWALKS walkways can run perpen-provides 360º of slip resistance. The 18-dicular, parallel and even diagonally togauge plank grating features an “openthe roof seams. There are three basicgrid design” that helps prevent build-upof ice, snow, mud and other debris.These self-cleaning planks are available inworking lengths of 20-ft. and 24-ft.NO PENETRATION INSTALLATION!The unique design of the ROOFWALKSanchoring clip and support plates enablesmost applications of the rooftop walkwaysystem to be installed without roof penetration. This eliminates future problemareas associated with other types of roofaccess systems.4UNISTRUT

Previous PageNext PageReturn to LiteratureTMR O O F T O PUNISTRUTW A L K W A Y SROOF PROFILESCOST EFFECTIVE INSTALLATION and SERVICE LIFE!Pictured here are roof profile examples of the six group types of metalstanding-seam roof panels. Unistrut ROOFWALKS systems are customdesigned to fit virtually every type of industrial rooftop.ROOFWALKS . . .The low-cost solution to damaged ribs and panel seam sepa-Group Arations and other costly damage caused by rooftop traffic.The low-cost of installation, virtually no-maintenance costand long service life, makes ROOFWALKS rooftop walkways24” O.C.the most cost-effective system available today for roof andservice personnelprotection. Rooftop projects could have labor time costsreduced with ease of workers ability and confidence to travelacross roof.This panel style features a unique “wrap-around” sealed seam. Commonly these standing-seams are located 24“ O.C.*Group BEASY SET-UP INSTALLATION! United Interlock steelplanks are strong yet lightweight, making installation quickand easy. Installation of a ROOFWALKS system requires onlyone or two workers. No need for special tools, hoists, cranesor other large equipment. One man can carry a 24-ft plank,(Also 30” O.C.)16” O.C.Look for distinctive inverted “L-shaped” interlocking standing-seams,16” O.C. Additional vertical return leg adds panel strength.Group Ctypically the largest single component of the ROOFWALKSinstallation. ROOFWALKS. . .quick, easy and field proven to20” O.C.perform, all this and economical.“Underwrap” designed standing-seams addto the strength and integrity of Group C roof panel style. 20” O.C.Group D18” O.C.(Also 12” & 20” O.C.)Group D roof panel styles features rugged looking “T-shaped” standing-seams, commonly placed at 18” O.C.Group E18” O.C. . .CHOOSE ROOFWALKS —. . .SPEC ROOFWALKS!(Also 16” O.C.)Interlocking design, inverted “L-shaped” standing-seams, feature a gentle roll-over wrap. Additional, low-profile, roll-formed vertical ribs arecommon. Both 16” O.C. and 18” O.C. may be found.Group F12” O.C.The “R” panel roof profile with sturdy 12” O.C. high rib design is theonly panel roof that may need penetration when installing a walkway.*CECO-LOC standing-seams located 30” O.C.NOTE:HELPMAN: 1 8 0 0 5 2 1 7 7 3 0Each group profile has a common “On-Center” distance unique to thatspecific group. If it is determined that a roof is of a size other thanshown or is from a manufacturer not listed, please contact theROOFWALKS HELPMAN!5

Previous PageNext PageReturn to LiteratureTMR O O F T O PROOFWALKS Systems For TypicalDesign MetalStanding-SeamRooftopsW A L K W A Y SUnistrut ROOFWALKS are available for allInterlock Grating with anti-skid walk surface.Group A metal “standing-seam” roofs.For perpendicular and diagonal applications,All ROOFWALKS walkway systems includethe walkway grating is attached directly tothe necessary hardware to allow properthe standing-seams by means of specialinstallation to the type of roof as listed inROOFWALKS rib-clip bolt assembliesGroup A. Systems may be ordered to rundesigned for each “seam configuration”.perpendicular, diagonally or parallel tostanding-seams.ROOFWALKS ANTI-SKID GRATINGUnistrut ROOFWALKS systems for “standing-DESCRIPTIONseam” roofs features a walkway of UnitedGAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PGPARTS ASSEMBLY GUIDE ATIONAmerican BuildingStand Seam IIG101Atlantic BuildingN/AG101A.S.C. PacificWeather Seam 24 G101Butler BuildingM.R.-24PARTS LIST AND BASIC DIMENSIONSGROUPA COMPONENTLISTINGSPARALLEL APPLICATIONSWIDTHDESCRIPTIONQTYASSEMBLY NO:18Inch12345Support PlateRib ClipHold Down ClipsBolts: 5/16”x 3/4 “SD/ST Screws12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsCeco-LocG105CarlisleVersa Lok S.S.P.G101Gulf StatesN/AG101Mesco BuildingMulti-RibG10112345Support PlateRib ClipsHold Down ClipsBolts: 5/16” x 3/4”SD/ST ScrewsMetal Sales Inc.-----G101Morin CorporationMss-24 or S.S.-12 G101M.B.C.I.Ultra Deck 124G101Nucor BuildingS.S.R.G101Star BuildingStarshieldG10112345Support PlateRib ClipsHold Down ClipsBolts: 5/16’ x 3/4”SD/ST ScrewsU.S.A. BuildingN/AG101Varco-PrudenS.S.R.G101Wedgecore Inc.----G10114242ASSEMBLY NO:G101Ceco BuildingUNISTRUT24Inch14242ASSEMBLY NO:27Inch14343ASSEMBLY NO:36Inch14444ASSEMBLY NO:48Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16” x 3/4”SD/ST Screws14646PART NO:PART PGGHCSO31075-EGGHTSO12075-EGPERPENDICULAR APPLICATIONSDESCRIPTION6267QTYPART NO:ASSEMBLY NO:G101-BARib ClipRecess WasherBolt: ntity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.

Previous PageNext PageReturn to LiteratureGroup A5PERPENDICULARRUNPARALLELRUN37641TELATP"ERO 0 ATPP 5'- T PLUSS G R NUM IN PPO LIIM SPACE SU R PURXT EMACA OVLO22PARALLEL SUPPORT PLATE ASSEMBLYPERPENDICULAR BOLT ASSEMBLY24"12" M/F12" M/M3476ROOF225121DESCRIPTIONPART NUMBERSSupport PlateG827B-PGG837-PGG848B-PGG860-PGRib Clip45G811-ALDESCRIPTIONPART NUMBERS5/16” x 3/4”Hex Head Cap BoltGHCSO31075-EG#12 - 3/4”Self-Drilling/SelfTapping ScrewGHTSO12075-EGRecessed WasherG714-EG5/16” x 3-1/4”Hex Head Cap BoltGHCSO31325-EG63Hold Down ClipG607-PG77

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SUNISTRUTGroup B roof manufacturers each have theworkers to finish projects faster and safer.need for special installation assembly pack-All this leads to greater economical controlages. Unistrut has developed a anchoringof the ever shrinking corporate dollar.system that’s unique to each manufacturer.ROOFWALKS. . .Standing on our reputation!It is these anchoring clips and support platesof the ROOFWALKS system that allowworkers to safely access rooftop maintenance projects. A ROOFWALKS rooftopwalkway system provides a “visiblesidewalk” for workers. Confidence enablesCustom DesignedFor EasyInstallation onStanding-SeamPARTS LIST AND BASIC DIMENSIONSGROUPB COMPONENTPARALLEL APPLICATIONSWIDTHDESCRIPTIONRooftops.QTYASSEMBLY NO:18Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x1-1/2“SD/ST Screws12222ASSEMBLY NO:24Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x1-1/2”SD/ST Screws12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x1-1/2”SD/ST Screws14343ASSEMBLY NO:ROOFWALKS ANTI-SKID GRATINGDESCRIPTIONGAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PG27Inch8STANDING-SEAMPANELDESIGNATIONA & S BuildingSystemVista SealG113Inland BuildingS.S.-18G109Steelox BuildingSteeloxG104Summit BuildingN/AG10814343ASSEMBLY NO:36Inch12345PARTS ASSEMBLY GUIDE NUMBERBUILDINGMANUFACTURERLISTINGSSupport PlateRib ClipsHold Down ClipsBolts: 5/16”x1-1/2”SD/ST Screws14444ASSEMBLY NO:48Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x1-1/2”SD/ST Screws14646PART NO:PART NO:PART 50-EGGHTSO12075-EGPERPENDICULAR APPLICATIONSDESCRIPTION267QTYPART NO:PART NO:PART NO:ASSEMBLY GG710-EGG714-EGGHCSO31400-EGRib ClipRecess WasherBolt: 5/16”x4”111*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.G710-EGG714-EG***GHCSO31400-EG

Previous PageNext PageReturn to LiteratureGroup B5PERPENDICULARRUNPARALLELRUN37641TEPLATEOR 0" ATPP 5'- PLSU G ORT INSUM IN PP LIM SPACE SU R PURXT EMACA OVLO2PARALLEL SUPPORT PLATE ASSEMBLY3GRATING5PERPENDICULAR BOLT ASSEMBLYGRATING467122DESCRIPTION1Support PlatePART NUMBERSDESCRIPTIONG718B, G747, G730-PGG720-PG, G736B-PGG726-PG, G740-PGG727-PG, G751-PG4G710-PG652Rib Clip3Hold Down ClipG607-PG75/16” X 1-1/2”Hex HeadCap Bolt#12 - 3/4”Self-Drilling/SelfTapping ScrewPART NUMBERSGHCSO31150-EGGHTSO12075-EGRecessed WasherG714-EG5/16” x 4”Hex Head Cap BoltGHCSO31400-EG9

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SUNISTRUTGroup C roof manufacturers have the needfor a special ROOFWALKS walkway system.For this group, Unistrut has designed systemanchoring clips and clamps that workspecifically with the unique contour of thestanding-seams and profile of the metalpanels. As with all ROOFWALKS walkways,systems for Group C roofs may run in anydirection; parallel, perpendicular or diagonalto the standing-seams.Unique Designof AnchoringSystem PermitsInstallation WithoutPARTS LIST AND BASIC DIMENSIONSGROUPC COMPONENTLISTINGSPARALLEL APPLICATIONSWIDTHDESCRIPTIONPenetration.GAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.18InchSupport PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsHex Nuts: 5/16”24Inch123458Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsHex Nuts: 5/16”ASSEMBLY -EGGHTSO12075-EGHHXN031-EG27Inch123458Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsHex Nuts: 5/16”ASSEMBLY -EGGHTSO12075-EGHHXN031-EG36Inch123458Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsHex Nuts: 5/16”ASSEMBLY -EGGHTSO12075-EGHHXN031-EG48Inch123458Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST ScrewsHex Nuts: 5/16”ASSEMBLY -EGGHTSO12075-EGHHXN031-EGG11282 PGPARTS ASSEMBLY GUIDE NUMBERBUILDINGMANUFACTURERStran BuildingSTANDING-SEAMPANELDESIGNATIONS.R.-100PART NO:123458ROOFWALKS ANTI-SKID GRATINGDESCRIPTIONQTYASSEMBLY 1075-EGGHTSO12075-EGHHXN031-EGPERPENDICULAR APPLICATIONSDESCRIPTION10345813Hold Down ClipBolt: 5/16”x 3/4”S.D.S.T. ScrewHex Nut: 5/16”Rib ClipQTYASSEMBLY NO:11111*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.PART -EGG702-PG

Previous PageNext PageReturn to LiteratureGroup C5PERPENDICULARRUNPARALLELRUN35344113TELATP"ERO 0 ATPP 5'- PLSU G ORT INSUM CIN PP RLXIM SPATE SUER PUAMCA OVLO882PARALLEL SUPPORT PLATE ASSEMBLYPERPENDICULAR BOLT ASSEMBLY5331328118DESCRIPTIONPART NUMBERSSupport PlateG738-PGG739-PG452544Rib ClipG703-PG8DESCRIPTIONPART NUMBERS5/16” x 3/4”Hex Head Cap BoltGHCSO31075-EG#12 - 3/4”Self-Drilling/SelfTapping ScrewGHTSO12075-EGHex Nut: 5/16”HHXNO31-EGRib ClipG702-PG3Hold Down ClipG607-PG1311

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SUNISTRUTGroup D metal standing-seam roofs featureno. G809-PG works specifically with thea unique profile.unique standing “T” contour of the seams.Manufacturers of this type of roof haveROOFWALK walkways for Group D roofsdesigned the standing-seams to form a “T”may run in any direction; parallel, perpen-as the seams join together. Unistrut engi-dicular or diagonal to the standing-seams.neers have designed a special rib-clamp forROOFWALKS. . .Standing on our reputation!this Group D systems. ROOFWALKS clampPARTS LIST AND BASIC DIMENSIONSEliminate RoofDamage CausedGROUPD COMPONENTLISTINGSPARALLEL APPLICATIONSWIDTHDESCRIPTIONBy Dishing and Punctures FromFoot Traffic.QTYASSEMBLY NO:18Inch134589Support PlateHold Down ClipsBolts:5/16”x3/4”SD/ST ScrewsHex Nuts: 5/16”Rib Clamps24Inch134589Support PlateHold Down ClipsBolts: 5/16”x3/4”SD/ST ScrewsHex Nuts: 5/16”Rib Clamps27Inch134589Support PlateHold Down ClipsBolts: 5/16”x3/4”SD/ST ScrewsHex Nuts: 5/16”Rib Clamps36Inch134589Support PlateHold Down ClipsBolts: 5/16”x3/4”SD/ST ScrewsHex Nuts: 5/16”Rib Clamps48Inch134589Support PlateHold Down ClipsBolts: 5/16”x3/4”SD/ST ScrewsHex Nuts: 5/16”Rib Clamps124244ASSEMBLY NO:ROOFWALKS ANTI-SKID GRATINGDESCRIPTIONGAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PGPARTS ASSEMBLY GUIDE ATIONPascoe BuildingA.S.R.-IVG109Steelite BuildingR.S.-18G109134344ASSEMBLY NO:134344ASSEMBLY NO:144444ASSEMBLY NO:164644PART R APPLICATIONSDESCRIPTIONQTYASSEMBLY NO:1224678910Rib ClipBolt: 5/16” 3/4”Recess WasherBolt: 5/16”x 4”Hex Nut: 5/16”Rib ClampRib Clip1111111*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.PART HHXNO31-EGG808-PGG809-PG

Previous PageNext PageReturn to LiteratureGroup D5PERPENDICULARRUNPARALLELRUN37644101TEPLATEOR 0" ATPP 5'- T PLUS G R NSUMACIN UPPOURLIMIPX S TE S ER PMACA OVLO9982PARALLEL SUPPORT PLATE ASSEMBLY54PERPENDICULAR BOLT ASSEMBLY7346291281DESCRIPTIONPART NUMBERSSupport PlateG747-PGG748-PG867Rib ClipG710-PGHold Down ClipG607-PG83910DESCRIPTIONPART NUMBERSRecessed WasherG714-EG5/16” x 4”Hex Head Cap BoltGHCSO31400-EGHex NutHHXNO31-EGRib ClampG808-PGRib ClipG809-PG9455/16” x 3/4”Hex Head Cap Bolt#12 - 3/4”Self-Drilling/SelfTapping ScrewGHCSO31075-EG10GHTSO12075-EG13

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SUNISTRUTGroup E roof manufacturers have incorpo-installation versatility and cost savings overrated a unique over/under snap-lock stand-other rooftop walk systems.ing-seam design. This type of standing-ROOFWALKS. . .Standing on our reputation!seam roof requires ROOFWALKS special ribclip no. G811-AL. This clip allows the newsystem to be anchored to the seams givinggreater support to the walkway itself.Group E ROOFWALKS rooftop walkwaysmay run parallel, perpendicular or diagonalto the standing-seams, allowing greaterRooftop WorkersWalk SafelyOn Anti-SkidGrating Surface.PARTS LIST AND BASIC DIMENSIONSGROUPE COMPONENTLISTINGSPARALLEL APPLICATIONSWIDTHDESCRIPTIONQTYASSEMBLY NO:18Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4“SD/ST Screws24Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16”x 3/4”SD/ST Screws27Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16” x 3/4”SD/ST Screws36Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16’ x 3/4”SD/ST Screws48Inch12345Support PlateRib ClipsHold Down ClipsBolts: 5/16” x 3/4”SD/ST Screws14242ASSEMBLY NO:ROOFWALKS ANTI-SKID GRATINGDESCRIPTIONGAUGEASSEMBLY NO:PART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PGPARTS ASSEMBLY GUIDE ATIONChief Industries*L.T.L. RoofG107Fabral BuildingS.S.R.G1111434314343ASSEMBLY NO:14444ASSEMBLY NO:14646PART NO:PART SO31075-EGGHTSO12075-EGPERPENDICULAR APPLICATIONSDESCRIPTIONQTYASSEMBLY NO:26714Rib ClipRecess WasherBolt: 5/16”x 3-1/4”111PART NO:G107-BAG811-ALG714-EGGHCSO31325-EG*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.PART NO:G111-BAG811-ALG714-EG*GHCSO31325-EG

Previous PageNext PageReturn to LiteratureGroup E5PERPENDICULARRUNPARALLELRUN37641TELATP"ERO 0 ATPP 5'- PLSU G ORT INSUM CIN PP RLXIM SPATE SUER PUAMCA OVLO22PARALLEL SUPPORT PLATE ASSEMBLYPERPENDICULAR BOLT ASSEMBLY34675112DESCRIPTIONPART NUMBERSSupport PlateG722-PGCHIEFG723-PG}G732-PGFABRALG733-PG }2452Rib ClipG811-ALHold Down ClipG607-PG673DESCRIPTIONPART NUMBERS5/16” x 3/4”Hex Head Cap BoltGHCSO31075-EG#12 - 3/4”Self-Drilling/SelfTapping ScrewGHTSO12075-EGRecessed WasherG714-EG5/16” x 3-1/4”Hex Head Cap BoltGHCSO31325-EG15

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SUNISTRUTGroup F ROOFWALKS rooftop-walkway system shares a similar design as to the metalstanding-seam roof. This common roofpanel is supplied by many different manufacturers, Varco-Pruden, CECO and American Building to name a few. The highstanding-ribs of the metal panels are commonly found to be at 12-inches O.C. It isbecause of this design that Group F is theonly ROOFWALKS system that requires roof-ROOFWALKS Rooftop-Walkwaysare the rightpenetration to secure the walkway to theroof panels.**Field tested and proven, ROOFWALKSrooftop-walkways are simply the best forproduct value and performance.solution toROOFWALKS. . .Standing on our reputation!rooftop pedestrianfoot traffic.PARTS LIST AND BASIC DIMENSIONSGROUPF COMPONENTLISTINGSALL APPLICATIONSWIDTHDESCRIPTIONQTYASSEMBLY NO:18Inch135Support PlateHold Down ClipsSD/ST ScrewsASSEMBLY NO:ROOFWALKS ANTI-SKID GRATINGDESCRIPTIONGAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PG24Inch135Support PlateHold Down ClipsSD/ST ScrewsAll 12” O.C.27Inch135Support PlateHold Down ClipsSD/ST Screws1315ASSEMBLY NO:36InchG1141315ASSEMBLY NO:PARTS ASSEMBLY GUIDE NUMBERMOSTSTANDING-SEAMBUILDINGPANELMANUFACTURERS DESIGNATION1214135Support PlateHold Down ClipsSD/ST Screws1416PART G*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.** Please see ROOFWALKS warranty page for important liability information regarding Group F systems.16

Previous PageNext PageReturn to LiteratureGroup F5PERPENDICULARRUN35PARALLELRUN315SEALANT*(NOT SUPPLIED)1Maximum Support PlateSpacing: 5'0". Locate SupportPlate Over “Purlin” WheneverPossible.12" O.C.PARALLEL SUPPORT PLATE ASSEMBLY5PERPENDICULAR BOLT ASSEMBLY353113512" O.C.1DESCRIPTIONPART NUMBERSSupport PlateG760-PGHold Down ClipG607-PGSelf-Drilling/SelfTapping ScrewGHTSO12075-EG* Group F requires that a sealant (not supplied) be applied under eachsupport plate.IMPORTANT INSTALLATION NOTICE:The penetration method shown here is the only method tobe used when installing a Roofwalk System on a Panel Ribroof. This is due to the design of the “Panel Rib” roof nothaving a standing seam for the Roofwalk to be attached.BEFORE INSTALLATION BEGINS, please contact your representative for further information. Roof manufacturerswarranty may be made void and Unistrut Corporationdeclines responsibility for any void in warranty!17

Previous PageNext PageReturn to LiteratureTMR O O F T O PW A L K W A Y SBuilt-up, membrane, foam and coated roofsmay appear intact. . .but, in fact may beleaking beneath the surface, destroying thestructural integrity of the roof.The cause could have been foot traffic onthe roof for a variety of reasons. No matterhow careful a worker tries to walk across aroof - unseen damage may occur due to theUNISTRUTROOFWALKS solves this problem. Specialwalkway stands and pads help provide asecure anchor for the ROOFWALKS system WITHOUT ROOF PENETRATION.Adding safety for workers and savingwhat could be thousands of dollars in roofdamage repair.ROOFWALKS. . .Solutions that work!stress. This damage may lead to expensiveroof and interior repairs. ROOFWALKSPARTS LIST AND BASIC DIMENSIONSSystems for Built-upand PrefabricatedMembrane RoofsGROUPG COMPONENTLISTINGSB U I L T-U P, M E M B R A N E, F O A M & C O A T E DWIDTHDESCRIPTIONQTYPART NO:18Inch12461112Support StandRib ClipsBolts:5/16”x 4-1/2”Recessed WasherRubber PadLock 01-28-PLHLKWO31-EG24Inch12461112Support StandRib ClipsBolts:5/16”x 4-1/2”Recessed WasherRubber PadLock 01-28-PLHLKWO31-EG27Inch12461112Support StandRib ClipsBolts:5/16”x 4-1/2”Recessed WasherRubber PadLock 01-31-PLHLKWO31-EG36Inch12461112Support StandRib ClipsBolts:5/16”x 4-1/2”Recessed WasherRubber PadLock 01-40-PLHLKWO31-EG48Inch12461112Support StandRib ClipsBolts:5/16”x 4-1/2”Recessed WasherRubber PadLock 01-52-PLHLKWO31-EGROOFWALKS ANTI-SKID GRATING18DESCRIPTIONGAUGEPART NO.2-1/2 x 9 MF18 ga.G92282 PG2-1/2 x 9 MM18 ga.G91282 PG2-1/2 x 6 MF18 ga.G62282 PG2-1/2 x 12 MF18 ga.G12282 PG2-1/2 x 12 MM18 ga.G11282 PG*Quantity of Hold Down Clips and SDST Screws Vary Depending on Walkway Widths.**Support Stands Provided in 20’ and 24’ Stock Lengths.

Previous PageNext PageReturn to LiteratureGroup GGRATING MAY TERMINATEAS SHOWN OR CONTINUE1246BOLT AND RIB CLIP ASSEMBLYINSTALL ON CENTER2SUPPORT STANDS SPACEDEVERY 5-6 FT.111SPRING RIB CLIP NESTSUNDER SUPPORT STANDSSUPPORT STAND ASSEMBLYPLANK GRATING61242111Rib Clip Bolt Assembly1DESCRIPTIONPART NUMBERS6” x 4” x 14 gaugeSupport Stand – 20’and 24’ Stock LengthsG61343-PGRib ClipG710-EG5/16” x 4-1/2”Hex Head CapFull Thread BoltGHCSO31450-EGPART NUMBERSRecessed WasherG714-EGRubber PadG501Lock WasherHLKW031-EG61124DESCRIPTION1219

Previous PageNext PageReturn to LiteratureTMR O O F T O PPvLAW A L K W A Y SNNINUNISTRUTGMETAL STANDING-SEAM ROOF. . .P E R P E N D I C U L A RFor Walkways Running Perpendicular or Diagonal tothe Standing-Seam: Steps 1, 2, 3, 4 and 6.1. Measure each run. Measure thedistance between every pair ofpoints to be linked by the newsystem.v v 2. Choose the width that fits yourneeds. Planks are available in six(6) nine (9) and twelve (12) in.widths. Combinations of widthsmay be used with one another toproduce various finished walkwaywidths in three (3) inch increments.A double-male (D-M) leg channel isused for one of the outer planks.All other planks making up thewalkway width have male-female(M-F) leg configurations.v v 3. Count the pieces of plank neededfor the correct length and width.Simply count the pieces of each typeplank needed to achieve overalllength and width. Planks are available in twenty (20) and twenty-four(24) ft. lengths and may easily befield cut to size.v 4. Determine required number ofbolt assemblies. For every 20/24-ft.section of plank —

Ceco Building Carlisle Gulf States Mesco Building Metal Sales Inc. Morin Corporation M.B.C.I. Nucor Building Star Building U.S.A. Building Varco Pruden Wedgcore Inc. Building A&S Building System Inland Building Steelox Building Summit Building Stran Buildings Pascoe Building Steelite Buil

Related Documents:

5.3. STAFInst Uninstall 6. Platform Installation Notes 6.1. Linux installation 6.2. AIX installation 6.3. HP-UX IA64 64-bit installation 6.4. IBM i 32-bit (previously known as i5/OS or OS/400) installation 6.5. z/OS installation 6.6. FreeBSD installation 6.7. Mac OS X installation 6.8. Solaris installation 7. Environment Variable Settings 7.1.

10.0 system installation - roof insulation 10.1-10.4 - ssr work points 10.5-10.6 - panel installation 10.7-10.12 - alternate ice damming weatherseal 10.3 - ssr module strip installation 10.14-10.15 - endlap installation 10.16-10.18 - ridge installation 10.19-10.30 11.0 fascia conditions - eave fascia installation 11.1 - eave gutter installation .

I9291 Remote Start/Keyless Entry Transmitter Installation I9292 Windshield Washer Solvent Heater Package Installation I9293 Multimedia Player Interface Module Package Installation I9294 Rearview Camera Package Installation I9295 Cellular Telephone Package Installation I9300 Roof Rack/Rail/Panel Installation

Antifreeze Solutions in Home Fire Sprinkler Systems 100138.04.000 May 28, 2010 CODE CONSULTANTS, INC. Page 1 Executive Summary NFPA 13, Standard for the Installation of Sprinkler Systems, has included guidance on the use of antifreeze solutions in fire sprinkler systems since the 1940 edition.1 Antifreeze solutions may be used in fire sprinkler systems where the piping system, or File Size: 942KBPage Count: 100Explore furtherNFPA 13: Standard for the Installation of Sprinkler .archive.orgNFPA 13: Standard for the Installation of Sprinkler Systemswww.nfpa.orgNFPA 13-2010: Installation of Sprinkler Systems (The .rtmconsultants.comNFPA 13 Standard For The Installation Of Sprinkler Systems .nfpa13.engineeringdesignresources. NFPA 13-2019: Installation of Sprinkler Systems Standard .blog.ansi.orgRecommended to you b

This installation manual is part of and shipped with the unit, and contains information on its safe installation. Read this installation manual completely before installing the unit. This installation manual must be kept available to installers at all times at the installation loca- tion. Keep this installation manual on hand throughout

Legal Design Service offerings Legal Design - confidential 2 Contract design Litigation design Information design Strategy design Boardroom design Mastering the art of the visual Dashboard design Data visualization Legal Design What is especially interesting in the use of visual design in a p

Installation Validation Tool for Installation Qualification (IQ) Introduction The Installation Validation Tool for Installation Qualification (IQ) may be used to validate that the software is installed completely and correctly. The tool can also be used to verify that no files have been changed since the software was installed.

Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 5 Figure 1 Control Unit on mounting plate Mechanical installation Note: The entire installation procedure shall be in accordance with national, local and company regulations. Mechanical installation Control Unit The installation of the