IDEAL INDUSTRIES INC.TECHNICAL MANUALMODEL 61-160 seriesThe Service Information provides the following information Precautions and safety information Specifications Performance test procedure Calibration and calibration adjustment procedureDocument:September1, 2009Page 1of 10

TABLE OF CONTENTSTitleIntroductionPrecautions and Safety InformationSafety InformationSpecificationsGeneral SpecificationVoltage Specifications% Voltage Drop SpecificationsImpedance SpecificationsDiode / Continuity SpecificationsPerformance VerificationStandardizing a Branch CircuitTable 1, Standardized DataTable 2, Performance Verification TestCalibrationReturn to Ideal Industries, IncPage111222222345566Document:Page 2of 10September1, 2009

IntroductionWarningTo avoid shock or injury, do not perform the verification tests or calibrationprocedures described in this manual unless you are qualified to do so. Theinformation provided in this document is for the use of qualified personnel only.CautionThe 61-150 and 61-160 serials contain parts that can be damaged by static is charge.Follow the standard practices for handling static sensitive devices.For additional information about IDEAL INDUSTRIES and its product and services, visitIDEAL INDUSTRIES web site at: www.idealindustries.comSAFETYReview the following safety precautions to avoid injury and prevent damage to thisproduct or any products connected to it. To avoid potential hazards, use the product onlyas specified.It is recommended that you read through the Operation or User manual before starting.Not all Caution, Warning, or Danger precautions are listed in this manual.CAUTIONThese statements identify conditions or practices that could result in damage to theequipment or other property.WARNINGThese statements identify conditions or practices that could result in personal injury orloss of life.Specific precautionsDo not operate without covers: To avoid personal injury, do not apply any voltage tothe product without the covers in place.Electric overload: Never apply a voltage to a Contact on the product that is outside therange specified for that connector.Avoid electric shock: To avoid injury or loss of life, use care when connecting anddisconnect adapter cord to a receptacle or while using the adapter with alligatorconnectors.Do not operate in wet/damp conditions: To avoid electric shock, do not operate thisproduct in wet or damp conditions.Document:September1, 2009Page 1of 10

Table 1, General specificationsDisplayOperating RangeVoltage RMSOhms FunctionPercentage of Voltage DropVoltage DropGround to Neutral VoltageGFCI currentOver-range Indication on allfunctionsOperating Environment,Relative HumidityStorage Environment:Case Construction:SafetyOLED Graphics Display108 to 264VAC85 to 132VAC (61-165),85 to 265 (61-164)0.00 Ω to 299 Ω0.1% to 50.0%0.1V to 50.0V0.0V to 24.0VCalculated E/R ( R is a fixed internal resistor)Display “OL”In Ohms Function readings 2.99 will be displayed as 30 C to 50 C (32 F to 122 F) 80%RH0 C to 50 C (32 F to 122 F) at 80% RHABS UL 94V/0/5VA ratedUL3111, and Design to comply with IEC1010-1 Cat III @ 150V AC RMS,UL for GFCI,UL for AFCITable 2, Ranges and Accuracy SpecificationsMeasurementLine Voltage/TrmsLine Voltage/PeakFrequency% Voltage DropVoltage DropNeutral-Ground V1 2Impedance - Hot ,Neutral, & GroundGFCI Trip TimeGFCI Trip CurrentRanges85 to 280VAC121 to 340VAC45.0Hz to 65.0HzCalculated 12A, 15A and 20AResolution0.1V0.1V0.1Hz0.1%Accuracy1.0% 2 digits1.0% 2 digits1.0% 2 digits2.5% 5 digitsCalculated 12A, 15A and 20A0.0V to 10.0V RMS0.00Ω to 2.99Ω 2.99 Ω - Unspecified.1ms to 6500ms counter.0001mS2.5% 5 digits2.5% 5 digits5.0% 5 digits-.01.0% 2 digitsBetween 6mA to 9mA0.01A1.0% 2 digits0.1V0.01v0.01Ω1Resistance greater than 3 ohms on the Hot conductor or greater that 3 ohms on the neutral conductorshould be verified via alterative methods.2Resistance greater than 3 ohms on the ground should be verified via an alterative method.Document:September1, 2009Page 2of 10

PERFORMANCE VERIFICAITONSPerform the following analysis. If the meter operates within the specifications listed inTable 2 the meter is functioning correctly. If the meter does not conform to any of thelisted limits unit should be returned to Ideal Industries, Inc for calibration.Note: the accuracy of this performance test is affected by the assigned orstandardized values. The unit is initially set up in IDEAL Industrials testing lab inSan Diego Ca. under strict environmental and standard test conditions.Environmental and test circuit conditions can effect the verification process. Themethods for standardizing a circuit and the assignment of performance verificationvalues will have a direct impact on the accuracy of the test.Two methods can be used to determine performance. These are the Calculated VoltageDrop Method and Measured Voltage Drop Method. The circuit to which the SureTest isattached should be a dedicated branch circuit used for the purpose of performance testingthe accuracy.Calculated Voltage Drop Method Test should be conducted with a dedicated branch circuit where the wire size anddistance and wire impedance is known. If at all possible the test should have only one receptacle and if not possible testshould be conduct on the first receptacle of a branch circuit. It is recommended that the circuit be Isolated from other wiring to minimize anyinductance on the circuit. Use the following formulas as a basis to calculate circuit performance. TheSuretest should yield results that conform to Table 4.Basic Formula Single Phase circuit, Two Wire with ground Vd Drop in circuit voltage %Vd Percent of Voltage Drop R Resistance per Feet of conductor (Ohms/Ft.) 3 I Current in conductor (Amperes) L length of one conductor in Feet D Cross section area of conductor (Circular mils) 3 K Resistivity of Conductor @75 C434Can be found in Chapter 9-Table 8 of NEC Code BookK 12.9 for Copper conductors and 21.9 for AluminumVd 2K x L x Ior Vd 2(R x L) x I%Vd (Vd/Vrms)x100Document:September1, 2009Page 3of 10

Measured Voltage Drop MethodBefore we get into the standardization method of a branch circuit it would be good to goover the difference of Voltage drop {VD} verses % of Voltage Drop {%VD}. In a branchcircuit there is a Current* Resistance {IR} voltage drop across the wire. This is due to theresistance of each conductor as a function of wire size, length, and device connections.For most branch circuits the resistance or impedance stays constant while the currentvaries. The higher the current the greater the voltage drops. As an example to perform avoltage drop test and check the % of voltage drop you would need to perform thefollowing test in the field.Test equipment needed: True RMS Digital multimeter with ACV accuracy of 0.25% and ACC measurementaccuracy of 0.5% or better 8 to 12 Ampere, 1500W load with accuracy of .25% or betterMeasurements: Measure the Branch circuit voltage at no load Measure the Branch circuit voltage and current under loado The current measurement is very critical use the best method possibleo The VD and %VD below would be for the load current measurement.Calculate Voltage drop for any load we would use the following Vd rZ * A %Vd (Vd/V)*100For the following example the no load Voltage is 120V, loaded Voltage 115 with an 8amp load.V VD I rZ LVVoltage no-loadVoltage with loadVoltage no-load - Voltage w-LoadLoad CurrentTotal circuit ImpedanceTotal circuit Impedance is: rZ (V(no-load)-LV (w-load))/I rZ (120-115)/8 rZ 5/8 rZ .625Document:September1, 2009Page 4of 10

The %Vd at 8 amps would be %Vd (Vd/Vno-load) x 100 %Vd (5/120) x 100 %Vd (.0416) x 100 %Vd 4.16It should be noted that the higher the current the large the IR voltage drop and % ofVoltage Drop. To check the accuracy of the UUT at 12amp, 15amp and 20 amps we willuse the impedance as found with the 8 amp load of rZ 0.625. With this impedance wecan calculate the VD and % VD for any load current.So for a 12 amp load with a no load voltage of 120V the %VD is : Vd I x R Vd 12 x .625 Vd 7.5 %Vd (Vd/Vno-load) x 100 %Vd (7.5/120) x 100 %Vd (.0625) x 100 %Vd 6.25STANDARDIZING A BRANCH CIRCUITThis is the most straightforward way of standardizing a branch circuit for testing theSureTest . This procedure should be conducted only by qualified personnel. It is highlyrecommended that a license electrician be present to assist with the measurements of theconductors of the branch circuit being standardizeRecommended equipment: Constant Load of 8 to 10 amps at 1500W. It is highly recommended that thisloads be as stable as possible with little drift or error due to temperaturevariations. High accuracy True RMS voltage meter with accuracy of .25% or better. AC Current meter with and accuracy of .5% or better. Low resistance switch, or method to move Load from High and Neutral to Highand ground during testThe following measurements should be taking on a dedicated branch circuit if possible. Ifthere is any change in Line voltage or load on source during test it will have an adverseeffect on the measurement.For best results AC current should be measured using the series method on the High orHot conductor. The voltage and current measurements should be recorded with each steplist below.Document:September1, 2009Page 5of 10

Steps12345LoadNo-LoadLoad H-N,Load H-N,Load H-G,Load H-G,MeasurementV No load Voltage H-NV1 Voltage H-NV2 Voltage H-GV3 Voltage H-NV4 Voltage H-GCurrentN/ATo calculate the impedance of each conduct enter the values from the table above andcalculate the impedance each conductorCalculated ImpedancerZ1 (V-V1)/IrN (V2-V1)/IrG (V3-V4)/1rH1 (rZ-rN)11rZ Total branch circuit ImpedancerN Impedance of neutral conductorrG Impedance of the Ground wirerH Impedance of the Hot or HighconductorIf the method used to measure current employs a shunt resistor the internal shuntresistance of the meter should be taken into account in your calculations. On mostDMM’s this shunt resistance is around 0.1 ohm.Enter “Calculated Impedance” measurements into Table 3 below.Measure the PEAK voltage and enter in Table3Measure Frequency and enter into Table 3Measure Neutral to Ground Voltage and enter into Table 3Enter calculated %VD for 12 amps, 15 amps, and 20 amps and enter in to Table 1 belowReference Measured Voltage drop sectionFor best accuracy monitor RMS Voltage, Peak Voltage, N-G voltage during UUT test.These measured values could change.Performance Verification PreparationTo complete the performance verification the Measured Values column must be filled outin Table 3 through standardization practice or calculated methods. SeeSTANDRADIZING A BRANCH CIRCUIT above. Then plug in the Surtest and takereadings to fill out the SureTest Reading column in Table 3Note: The SureTest only takes reading when first plugged in. AC line voltage, peakand Frequency are the only continuous updated reading. Ground impedance is onlymeasured when the meter goes to that reading. If you are on a GFI protected circuit theground impedance measurement will most likely trip the device.Document:September1, 2009Page 6of 10

A comparison of the Standardized Measured Values to the SureTest Readings shouldyield results in accordance to the range and accuracy specification listed in Table 2.Table 3, Standardized DataAC Line VoltageAC Peak VoltageAC line Frequency% Voltage Drop 12A% Voltage Drop 15A% Voltage Drop 20ANeutral to Ground VHot ConductorNeutral ConductorGround ConductorMeasured ValueVVHz%%%VΩΩΩSureTest ReadingVVHz%%%VΩΩΩTable 4 illustrates how to combine the branch circuit measured values with thespecifications from Table 2 to create a table of values between which the SureTestreading should fall between to verify that it is with calibration.Table 4, Example of Field testedField Test for 61-164/61165MeasuredFunctionValuesSpecificationAC LineAC PeakAC Freq%VD 12%VD 15%VD 20N-G VoltageHotNGd1% /- 1 digit1% /- 1 digit1% /- 1 digit2.5% /- 5 digit2.5% /- 5 digit2.5% /- 5 digit2.5% /- 5digit5% /- 55% /- 55% /- 0.05% errorLow 4High 0.170.26The GFCI / Time test cannot be done in the fieldHigh Resistance Ground Fault Test (GFCI)A ground fault circuit-interrupter, the device should be capable of interrupting theelectrical circuit when there is a fault between 6mA and 264 mA with in the time intervalof T in the following relationshipDocument:September1, 2009Page 7of 10121.9172.0604.45.37.20.50.320.130.22

Calibration and calibration adjustment procedureThe SureTest 61-160 Series cannot be field calibrated. If Calibration is required pleasecall 800-435-0705 for return instructions.Document:September1, 2009Page 8of 10

IDEAL INDUSTRIES web site at: www.idealindustries.com SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use the product only as specified. It is recommended that you r

Related Documents:

IDEAL 4810-95 IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP B C A 4 x Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP Remove the stand from the wooden pallet. Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP 4 strong people are required to lift the machine from the pallet and place it on the stand. Secure with 4 .

IDEAL 4810-95 IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP B C A 4 x Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP Remove the stand from the wooden pallet. Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP 4 strong people are required to lift the machine from the pallet and place it on the stand. Secure with 4 .

IDEAL 4810-95/EP IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP C Only IDEAL 4810-95/EP Attach the enclosed hand-wheel for clamping. Parts and tools are in the tool set (C). Plug into socket. The machine must be connected directly to the socket. Installation

IDEAL LIFE GLUCO MANAGER, IDEAL LIFE POD, IDEAL LIFE Step Manager, IDEAL LIFE Breath Manager, IDEAL LIFE Direct Connect, IDEAL LIFE Health Tablet, REALIZING THE VISION OF A BETTER TOMORROW, Leveraging the Power of Communication, . Sprint provides full cellular network support for health information from anywhere. POD IDEAL LIFE and ADT announced

Prime Ideals and Maximal Ideals Definition (Prime Ideal, Maximal Ideal). A prime ideal A of a commuta-tive ring R is a proper ideal of R such that a,b 2 R and ab 2 A implies a 2 A or b 2 A. A maximal ideal A of R is a proper ideal of R if, whenever B is an ideal of R and A B R, then B A or B R.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-734 The Service Information provides the following information: Precautions and safety information Specifications . ACV 400 350.0V AC @ 50 or 60Hz 342.5 357.5 ACV 600 550V AC @ 50 or 60 Hz 534 566

Ideal Solution. In an Ideal Mixture, all components have the same size and they interact with each other uniformly. An Ideal Solution might better be called an Ideal Mixture, since, as in an Ideal Gas, no distinction is made between solute and solvent. All components of an ideal solution have chemical potentials of the form: μ of pure .

Altec Industries, Inc. Altria Client Services, Inc. Amdocs Inc. American Airlines, Inc. American Express Company American Red Cross Amgen Inc. AMN Healthcare Inc. . Google, Inc. GSD&M The Haartz Corporation Hallmark Cards, Inc. Halyard Health, Inc. Harley-Davidson Motor Company Harman International Industries