C ATA LO GReliaGear neXTUL 67 low-voltage distributionpower panelboards

In our ongoing commitment to offersuperior value at every touchpoint,from ordering to installation tomaintenance, we have combinedthe best technology of ABB and GEIndustrial Solutions to bring you atrue breakthrough in power panels.

1603. Molded case circuit breakers3004. Panelboard selection guide/numbering system500202. Panelboard details03040401. General characteristics01Table of contents

401General characteristics

5General characteristicsFeatures and benefits01General characteristics06Applications12Standards and certifications14

6RE LIAG E AR NE X T01Install components in seconds.Instill confidence for a lifetime.—01 Improved finger-safebus stack that meets IP20standards in select models—02 Spring-loaded circuitbreaker plug-in connectors—03 Bus stack can beflipped 180 degreesEASY TO INSTALLModular, flexible, fast.The ReliaGear neXT features a field-reversible bus stackthat can be flipped 180 degrees to accommodate top orbottom feeds without extra parts. Ground and neutrallocations are also field-swappable. These advantagesplus plug-in, single-tool simplicity enable easy, fastcomponent installation or replacement in the field. Foreven greater flexibility, circuit breakers can be installedanywhere on the bus stack.OUTSTANDING RELIABILITYDependable connections.Spring-loaded circuit breaker plug-in connectors withincreased plating thickness for durability withstandrepeated insertion and removal. Levering featuresfurther reduce installation and removal force. Thisplug-in connector design uses the magnetic forcesgenerated by a short circuit to help make the connectioneven tighter and more reliable. There are fewer boltedjoints that can become loose or require torque checks.ENHANCED SAFETY FEATURESThe next level of protection.ABB is passionate about safety. From the largest pieceof arc-resistant switchgear down to the smallest arcfault and ground fault sensing circuit breaker, ABB isalways designing ways to help keep personnel out ofharm’s way. ReliaGear neXT panelboard and switchboard designs come with an improved finger-safe busstack that meets IP20 standards. Thanks to the breakerintegrated Bluetooth technology, it is also possible toset parameters and check measurements directly fromyour smartphone from an arc-free zone.

ARTICLE OR CHAPTER TITLE—017—0101—02ImageCAN BEFLIPPED180 —03

8RE LIAG E AR NE X T01—Tmax XT plug-in circuit breakers featurespring-loaded primary disconnects, enablingfast installation, easy replacement and reliableconnection to maximize your uptime.

901ARTICLE OR CHAPTER TITLE

10RE LIAG E AR NE X T01Even more advantages.—01 Components canbe installed in aslittle as 20 seconds—02 Remote access toaccurate informationanywhere, anytimeREDUCED COSTSSpeed up your project.Reducing labor and saving time is crucial for electricalcontractors. In fact, an 8% savings in labor costs for a typicallarge project can mean 133% more profit for the contractor.*ReliaGear neXT’s intuitive single-person installation enablescomponents to be installed in as few as 20 seconds,dramatically saving skilled-labor costs, reducing downtimeand lowering the risk of mistakes.*From “How to Make a Good Estimate Even Better” by Don Kiper, EC&M, 2017.ADVANCED CONNECTIVITYLink to data analysis in real time.With ABB Ability cloud connectivity, multiple communicationoptions and built-in metering, the Tmax XT circuit breakers ofReliaGear neXT put facility managers in control. The extremeprecision of the data measured means users have access toaccurate information anywhere, anytime, making it easierto monitor resources and identify savings opportunities.ORDERING AND LOGISTICSEasy to stock.With ReliaGear neXT, you have a single catalog number for allcircuit breaker installation kits, convenient ordering with theempower configurator tool and ProStock options for quickdeliveries. Power panels are available unassembled or withfactory-assembled interior.The empower tool provides a new PanelScan feature inaddition to customizable dashboards, templates, productconfigurations and more to help users save time andreduce the risk of error.

1101ARTICLE OR CHAPTER TITLE—01—02

12RE LIAG E AR NE X T01Take your performance to the neXT level.ReliaGear neXT — a go-to power panel forprofessionals looking to gain the competitive edge:ContractorsFor contractors, time is money. And traditional bolt-onpower panels that require highly skilled labor and takehours to install or modify in-field can cost you big. Butnow there’s ReliaGear neXT. It works harder, so youdon’t have to.DistributorsSmart, optimized, simplified design helps distributorsmaximize stock inventory. The user-friendly and intuitiveempower tool minimizes the configuration process timeby providing product drawings, bills of materials andtechnical documentation.ReliaGear neXT is ideal for small to largeprojects and any application where speed,reliability and performance matter:Consultants and engineersReliaGear neXT adds value to any job, giving consultantsthe power to influence customer specifications, helping tomake life easier, providing safety features for installersand significantly reducing downtime for end users. Thebroad offering allows ABB to provide the right productfor the right application.OEMs and panel buildersVersatility, easy installation and performance makeReliaGear neXT a perfect match for quality panels andany type of equipment.Facility managersReliaGear neXT enables fast component installationor replacement, reducing downtime and cost. And itsconnectivity helps managers monitor resources andidentify savings opportunities. Industrial complexes Commercial buildings Residential developments Health care facilities Data centers Food and beverage facilities Infrastructure projects And more

0113

14RE LIAG E AR NE X T01General characteristicsStandard and certificationsThe low-voltage power panelboards and protection devicesin this specification are designed and manufacturedaccording to the latest revision of the following standards(unless otherwise noted): ANSI/NEMA PB 1, panelboards ANSI/NFPA 70, National Electrical Code Federal specification W-C-375, rev. B, amend. 1, circuitbreakers, molded case; branch circuit and service Federal specification W-P 115, rev. C, panel, powerdistribution UL 489, molded case circuit breakers CSA 22.2 No. 5-13, molded case circuit breakers UL 50, enclosures for electrical equipment UL 67, panelboards UL 98, enclosed and dead front switches cUL listing low-voltage modular power panels Seismic certification according to ICC-ES AC156

GENER AL CHAR AC TERISTICS1501Notes

1602Panelboard details

17Panelboard detailsPanelboard details18Enclosures19Bus stack20Interior frame21Fronts, gutter doors, blanks and fillers22Door-in-door option23Panelboard configurations24Installation technical data25Accessories2602Introduction

18RE LIAG E AR NE X T02Panelboard detailsIntroductionThe ReliaGear neXT power panelboard can be equipped withcircuit breakers from 15 A to 1200 A. The maximum shortcircuit rating is equal to 200 kAIC at 240 V, 100 kAIC at 480 Vor 65 kAIC at 600 V, or the lowest current interruption rating ofany device installed, except as noted in the series rating listedwith an integral or remote main breaker or fusible switchinstalled ahead of the power panel.ReliaGear neXT power panelboards can be usedon the following system voltages: 240 V AC; 3-phase, 3-wire 480 V AC; 3-phase, 3-wire 600 V AC; 3-phase, 3-wire 208Y/120 V AC; 3-phase, 4-wire 480Y/277 V AC; 3-phase, 4-wire 600Y/347 V AC; 3-phase, 4-wire 240/120 V AC Delta hi-leg; 3-phase, 4-wire 120/240 V AC; 1-phase, 3-wire

PA N E L B O A R D D E TA I L S19The ReliaGear neXT panelboard is offered in 12 enclosure sizeconfigurations, with three different widths (30", 40", 45") andfour different heights (60", 72", 84", 96"). These configurationssimplify design and maximize stock inventory. All enclosuresare available in surface-mounted design.Each enclosure is NEMA-compliant, ANSI 61 finished codegauge steel.Different enclosure types are available and compliantwith the UL 50 standard:NEMA 1For indoor use to provide a degree of protection topersonnel against access to hazardous parts and toprovide a degree of protection against ingress of solidforeign objects (falling dirt).Optional drip hood is also available.NEMA 2For indoor use to provide a degree of protection to personnelagainst access to hazardous parts, falling dirt and harmfuleffects on the equipment due to the ingress of water (drippingand light splashing).NEMA 2 enclosure is provided with drip hoodand door-in-door.NEMA 3RFor either indoor or outdoor use to provide a degree ofprotection to personnel against access to hazardous parts,falling dirt and harmful effects on the equipment due tothe ingress of water (rain, sleet and snow); and that willbe undamaged by the external formation of ice and snowwith no damage to the external enclosure.NEMA 4/4XFor either indoor or outdoor use to provide a degree ofprotection to personnel against access to hazardous parts,falling dirt and windblown dust, and effects on the equipmentdue to the ingress of water (rain, sleet, snow, splashing waterand hose-directed water) and with no damage from theexternal formation of ice on the enclosure. 4X is stainlesssteel and corrosion resistant.NEMA 12Without knockouts, for indoor use to provide a degree ofprotection to personnel against access to hazardous parts,falling dirt and circulating dust (lint, fibers and flyings) and toprevent harmful effects on the equipment due to the ingressof water (dripping and light splashing) and to provide a degreeof protection against light splashing and consequent seepageof oil and non-corrosive coolants.02Panelboard detailsEnclosures

RE LIAG E AR NE X T2002Panelboard detailsBus stackThe bus stack consists of a back pan, busbars assembledone on top of the other and an insulator to protect fromlive components. Some bus stack configurations are IP201finger-safe, an industry-exclusive and patented feature.Sub-feed (dual main) lug and feed-through lug optionsare also available to address instances where a panelboardrequires more than one enclosure.It can be either bottom or top fed. Busbars can be copper oraluminum. Silver-plated copper busbars are available as heatrated or density-rated (1000 A per square inch); aluminumbusbars are available only as heat-rated. Tin-plated busbarsalso available for applications in harsh environments wherehydrogen sulfide is present, such as water treatment facilities.Six bus stack ampere ratings are available: 250 A, 400 A,600 A, 800 A, 1000 A and 1200 A.The bus stack dimensions are optimized to reach the highestpower density and number of circuits. Four differentdimensions are available: 16X, 24X, 32X and 40X.We define X-space as the number of mounting positionsavailable on each bus stack side. One X-space is equal to1.385". Each circuit-breaker frame and bus-stack-mountedaccessory has specific requirements for X-spaces. Eachset of lug pads also requires four mounting spaces. Referto the breaker section for more details.Both main lug only (MLO) and main circuit breaker (MCB)configurations are available. The main circuit breaker canbe either vertically or horizontally mounted. For the mainlugs option, an appropriate barrier post kit is needed.Standard mechanical lugs are available from 250 kcmil upto 750 kcmil. Compression lugs are also offered from 1/0to 750 kcmil.ReliaGear neXT features a field-reversible bus stack that canbe flipped 180 degrees to accommodate top or bottom feedswithout extra parts.1—Possible combinations of bus stack and enclosuresBus height16X24X32X40XBus typeNNBLBFNNBLBFNNBLBFNNBL—Possible combinations of bus stack and plating typeBus height16X24X–32X–40XBFBus typeEnclosure height (in.)ll72lllllllllllllllll96NN: clean bus, no lug padsBL: 1 set of lug padsBF: feed-through, 2 sets of lug ver1P–Tin3P–Silver3P–TinBus amperage6084Per IEC Standard 60529llll250 All400 Alllll600 Alllll800 Alllll1000 All1200 All1P–Silver: Single-phase silver plating1P–Tin: Single-phase tin plating3P–Silver: Three-phase silver plating3P–Tin: Three-phase tin platinglllll

PA N E L B O A R D D E TA I L S21To fit the bus stack into the enclosure, an interior frame isprovided. For 30"-wide panels, the bus stack can be mountedonly in the center of the enclosure. For 40"-wide panels, thebus stack must be offset, while on 45"-wide enclosures, thebus stack can be either center or offset mounted. Theseconfigurations help to achieve the highest ampacity andpower density.The interior frame also allows breakers to be well-positionedand properly bolted.02Panelboard detailsInterior frame

22RE LIAG E AR NE X T02Panelboard detailsFronts, gutter doors, blanks and fillersTop and bottom fronts, together with hinged gutter doors, completethe NEMA 1 enclosure style. Those grant independent access to eitherthe incoming section or the branch distribution section. Vented frontsare needed when a 100% rated breaker is required.Standard gutter doors do not prevent access to the breaker handle andtrip unit settings. Options for locking doors are available to prevent accessto the breakers. Locking doors are not available with horizontally mountedXT7 breakers.With certain breaker frames, a filler is needed to cover the gap between thegutter door and the breaker load side. If the bus stack is not completely fullof breakers, sheet metal blanks are needed to ensure isolation from live parts.

PA N E L B O A R D D E TA I L S23A door-in-door option is also available with the ReliaGear neXTpower panelboard.This kit consists of two different doors, one within the other: The circuit breaker door, which provides access to the breaker operatinglevers with no risk of contact with live parts; The deadfront door, which gives access to the entire panel interior.To complete the installation, a filler and a support are also needed.The door-in-door is required with NEMA 2 enclosures.02Panelboard detailsDoor-in-door option

RE LIAG E AR NE X T2402Panelboard detailsPanelboard configurationsThe ReliaGear neXT panelboard is available with differentlysized bus stack configurations. Once the main bus ampacityis determined, the height of the bus determines both theheight of the panelboard and the maximum number ofavailable outgoing branch Tmax XT, Record Plus FB and TEYcircuit breaker X-spaces. Different circuit-breaker frame sizesrequire different numbers of mounting positions on the busstack. See page 43 for details.Main lugs and main circuit breaker options are both availableup to 1200 A. The main circuit breaker can be either verticallyor horizontally mounted. For vertical circuit-breaker mounting,XT5 or XT7 mounting kits are required.All ReliaGear neXT panelboards are double sided, with branchbreakers that can fit on both the left and right sides of the busstack. The maximum ampacity of the breakers selected willdetermine the width of the panelboard needed. The bus stackcan either be mounted in the center of the box or be offset tothe right (default) or to the left. With an offset configuration,the maximum ampacity of the branch breakers mounted onthe narrow and wide sides is different. This allows thepanelboard to comply with the wire-bending spacerequirements per UL 67.—Available configurationsPanelboard width (in.)Bus stack position inside the boxMax. branch breaker ampacityon wide side (A)Max. branch breakerampacity on narrow side (A)225 (XT4)30Center225 (XT4)40Offset600 (XT5)225 (XT4)45Center600 (XT5)600 (XT5)45Offset1200 (XT7)225 00 A225 AXT5XT1XT5XT4XT4XT4—30" center box—4 configurations225 A—40" offset boxFB/TEY1200 A—45" offset boxFB/TEYXT1XT4XT4XT4XT4XT4XT4225 AXT5XT1XT1XT4XT5XT4XT4FB/TEYFB/TEY225 A600 A—45" center boxXT1600 A

PA N E L B O A R D D E TA I L S25Panelboard detailsInstallation technical data02—Torque values for panelboard hardwareScrew size 4 –20 steel-thread forming1LocationTorque (in.-lb.)Fronts to enclosure (sides)85–95Interior frame to enclosureNeutral and ground to enclosureFillers to gutter coversVertical main mounting kit for enclosureFronts to enclosure (top/bottom)50–58Branch breakers to interior framePanelboard interior to interior frameVertical main insert/filler(s) to panelsBlanks to interior frame—01 The enclosuredepth is 10.8" forNEMA 1 and 14.5" forall other NEMA types.Refer to the drawingat right for mountinghole locations.ABHAACCDW—01—NEMA 1 enclosure mounting holesPlate hole distance from edgesHeightHoles—Panelboard "48"–5"W72"48"–5"D84"68"42"5"96"68"48"5"11" NEMA 111" NEMA 1 DiD or drip hood 111" NEMA 2 114.5" NEMA 3R 214.8" NEMA 4/4X/12 2 oor In door and drip hood increase the total dept to 14.5" but theDusable conduit space remains 11".2 D epth for NEMA 3R/4/4X/12 does not include 0.9" of hanger bracket.1

26RE LIAG E AR NE X T02Panelboard detailsAccessoriesNeutralsNeutral with lug sizes ranging from 1/0 to 750 kcmil(accepting both copper and aluminum wires). Neutrals areall isolated, and bonding kit is included. 200% neutrals areavailable. Optional neutrals with ground fault CTs are alsoavailable (for main breaker only).GroundsGrounding kits are available in both isolated and bondedversions. They can accommodate 10 or 47 wires, aluminumor copper.Service entrance kitsService entrance barrier kits are available for XT4, XT5, XT6and XT7 for the following wire sizes: 300 kcmil, 350 kcmil,400 kcmil, 500 kcmil and 750 kcmil.

PA N E L B O A R D D E TA I L S27Surge protection devicesThe SPD module is a plug-in accessory to be installed on thebus stack. This accessory can fit into panels 40" or 45" wide.—Available in different configurations according to system voltage, impulse currentand type:System voltage120 V AC Wye, 277 V AC Wye, 347 V AC Wye,480 V AC DeltaImpulse current65 kA, 80 kA, 125 kA, 150 kA, 200 kA, 300 kASPD type (according to NEC)Type 1: Surge arresterType 2: TVSSRELT moduleWhen activated, the RELT (reduced energy let-through) modulehelps to mitigate arc flash hazard, limiting the duration offault current through the use of a user-selectable and settablesecondary instantaneous pickup setting. This is a plug-inaccessory to be installed on the bus stack, compatible withXT7 breakers with Ekip Touch trip units and can fit into panels40" or 45" wide.An additional wiring kit is needed to connect the moduleto the main circuit breaker, which is equipped with an EkipSignalling module and Ekip Supply module.Three different versions are available to cover all systemvoltages: 240 V–208/120 V 480 V–480/277 V 600 V–600/347 VDrip hoodThe drip hood prevents droplets from falling into theenclosure. A drip hood is supplied standard with NEMA 2enclosures, and is optional for NEMA 1 enclosures.02Panelboard detailsAccessories

28RE LIAG E AR NE X T02Panelboard detailsAccessoriesSingle-point metering unitThe AMP1 power and energy meter provides an integratedsolution for power monitoring and single-point metering.With exceptional performance, the AMP1 monitors keyelectrical parameters of the main power coming into thepanelboard. This information can then be transmitted toa building automation system (BAS), or similar system, toanalyze usage and identify potential cost-saving measures.Offering ANSI 12.20 0.5% accuracy, the AMP1 is revenue-gradeand features: Voltage, amperage, power and energy monitoring Backlit LCD display Data logging option to ensure data is still preserved locally Communication via Modbus RTU or BACnet – Versatile andwidely used protocols User-enabled password protection UL 67 approvalThe AMP1 module is a plug-in accessory to be installed on thebus stack. This accessory can fit into panels 40" or 45" wide.A set of current transformers must be selected according tothe ampacity needed for metering, together with a mountingkit for proper installation.

PA N E L B O A R D D E TA I L S2902Notes

3003Molded case circuit breakers

31Molded case circuit breakersTmax XT range32Record Plus FB and TEY42Mounting space requirements43Line-side connectors and lugs44Breaker accessories45Installation manualsConnectivity4748–4903Molded case circuit breakers

32RE LIAG E AR NE X TTmax XT rangeMolded case circuit breakers03The SACE Tmax XT range offers higher performance, better protection and moreprecise metering than equivalent units and can handle from 15 A up to 1200 A.Combined with precise electronic trip units in small frames,the new range delivers significant time savings and enhancesinstallation quality. Reliability is further increased, and speedof installation reduced, thanks to Bluetooth and Ekipconnectivity for mobile devices. Tmax XT circuit breakers andtheir accessories are constructed in compliance with UL 489and CSA C22.2 standards.The molded case circuit breakers for ReliaGear neXT powerpanelboards can also be used in ReliaGear SB switchboards.The same mounting hardware, fillers, spacers and rails arealso applicable for ReliaGear SB.—Molded case circuit breakers (MCCB)XT1Frame size[A]PolesRated voltage(AC) 50–60 Hz125[No.]3[V]480 V Δ (2)VersionsFixedInterrupting ratingsNSH[kA]5065100480 V (AC)[kA]253565600Y/347 V (AC)[kA]182225[kA]––240 V (AC)600 V (AC)Mechanical lifeDimensions – fixed(width x depth x height) (3)Weight (3)[No. operations]–25000[No. hourly operations]2403 poles[mm]/[in][76.2 x 185.16 x 264.67] / [3 x 7.29 x 10.42]Fixed 3 poles[kg]/[lb][1.69] / [3.73]Trip units for power distributionTMFTMAEkip DIPEkip Touch(1) Current-limiting circuit breaker in 480 V AC and 600 V AC(2) 600Y/347(3) Weights and dimensions include line-side connector and mounting bracketl

3303MOLDED C A SE CIRCUIT BRE 33, 43600600600600FixedFixedFixed, withdrawableFixedNSH (1)L (1)V (1)NSH (1)L 53525502500020.00020.0006510.000240240240240[104.9 x 198.12 x 248.67]/ [4.13 x 7.8 x 9.79][139.45 x 206.25 x 387.6]/ [5.49 x 8.12 x 15.26][209.04 x 211.33 x 487.93]/ [8.23 x 8.32 x 19.21][210.06 x 276.61 x 487.93]/ [8.27 x 10.89 x 19.21][2.87] / [6.33][7] / [15.43][12.02] / [26.51][17.18] / [37.89]lllllllllll

34RE LIAG E AR NE X T03Tmax XT range100% rated breakersAll Tmax XT circuit breakers are available both as standardversions and as 100% rated versions. Because of the additionalheat generated at 100% of continuous current rating, the useof specific 90 C rated wires sized per 75 C ampacity maybe required.FrameMax. ampacity (A)WiresXT420075 CXT540075 CXT780075 CXT71000/120090 C

MOLDED C A SE CIRCUIT BRE AKERS35Tmax XT rangeTrip unitsThe Tmax XT trip units are designed to be used in a wide rangeof applications. These complete, flexible protection trip unitscan be adapted to the actual level of protection required,independently of the complexity of the system.The range is available for three levels of performance to meetany requirement, from simple to advanced applications: TM thermal-magnetic trip unit Ekip DIP electronic trip unit Ekip Touch/Hi-Touch electronic trip unitsMolded case switches are also available as main circuitbreaker only.For the single-phase offering, the following trip unitsare available: XT1, XT4, XT5, XT6:-- TM thermal-magnetic trip unit XT7:-- Ekip DIP electronic trip unit-- Ekip Touch/Hi-Touch electronic trip units03SACE Tmax XT trip units represent a new benchmark formolded case circuit breakers, being able to satisfy anyperformance requirement.

36RE LIAG E AR NE X TTmax XT rangeThermal-magnetic trip unit03—The thermal-magnetic trip unit is an easy solution for protectionagainst overloads and short circuits. Overload protection is ensuredby the ABB thermal device, based on a temperature-dependentbimetal heated by current. Protection against short-circuit is realizedwith a magnetic device.—Key:1. Current thresholdfor short-circuitprotection.2. Rotary switch for shortcircuit protection.3. Current thresholdfor overloadprotection.4. Rotary switch foroverload thresholdsetting.1324Rotary switchDepending on the version, it is possible toset the desired thresholds for protectionby turning the front rotary switch.

MOLDED C A SE CIRCUIT BRE AKERS37Tmax XT rangeThermal-magnetic trip unitI – short-circuit protectionTrip unitCurrent thresholdTrip timeCurrent thresholdTrip timeTMFFixedFixedFixedFixed instantaneousTMAAdjustableFixedAdjustableFixed instantaneousPower distributionprotection—TMFIn llllllllllllllllXT4150175200225250lllll—TMAIn llll800l03L – overload protectionField of application

38RE LIAG E AR NE X TTmax XT rangeEkip DIP03—The first level of electronic trip units, Ekip DIP trip units, are basedon microprocessor technologies and guarantee high reliability,protection adjustability and coordination.They provide protection against overloads, selective short circuits, short circuits and ground faults.The power required for their operation is provided directly from the current sensors.—Key:1.DIP switches foroverload-protectionsetting.2. DIP switches forshort-circuit and timedelayed short-circuit.3. Slot for lead seal.4. Test connector.5. Power-on LED.31425DIP switchesThe DIP switches on the front of the trip unitallow manual settings when the trip unit is off.LEDsThe LEDs on the front indicate the status of therelease (on/off) and provide information aboutthe protection tripped when the Ekip TT accessoryis connected.Front connectorThe connector on the front of the unit allows theconnection of: Ekip TT for trip testing, LED-test and signallingof the most recent trip. Ekip T&P for connection to a laptop with the EkipConnect program (thus measurement reading,as well as trip and protection function tests, aremade available to the user).—Characteristics of electronic Ekip DIP trip unitsOperating temperatureRelative humiditySelf-suppliedAuxiliary supply (where applicable)Operating frequencyElectromagnetic compatibility*For 10 A: 0.4 in-25 C to 70 C98%0.2xIn (single phase)*24 V DC 20%45 to 66 HzIEC 60947-2 Annex FThermal memoryAll the Ekip DIP trip units include a thermal memoryfunction. The trip unit records the trips that haveoccurred in the last few minutes. Since the tripcauses overheating, to protect the cables and letthem cool down, the trip unit imposes a shorterdelay-tripping time in case of a fault. Thus, thesystem is protected against damage due tocumulative overheating. This can be disabledif needed by using the Ekip T&P.

MOLDED C A SE CIRCUIT BRE AKERS39Tmax XT rangeEkip DIPTrip unitPower distributionprotectionEkip DIPIn [A]XT4XT51025S – selective short-circuit protectionI – short-circuit protectionCurrent thresholdTrip timeCurrent thresholdTrip timeCurrent thresholdTrip 400ll60080010001200lllXT6llXT7ll03L – overload protectionField of application

40RE LIAG E AR NE X TTmax XT rangeEkip Touch/Hi-Touch03—Ekip Touch/Hi-Touch trip units provide a wide series of protectionsand high accuracy measurements of all electrical parameters. Theyare intended to integrate perfectly with most common automationand supervision systems.—Key:1. Power-on LED; prealarm LED; alarm LED.2. Test and programmingconnector.3. Display.4. Home pushbutton toreturn to homepage.5. Pushbutton fortesting and trippinginformation.31452Communication and connectivityThe Ekip Touch/Hi-Touch trip units integrateperfectly into most common automation andenergy management systems to improveproductivity and energy consumption and forremote control. The circuit breakers can beequipped with communication modules forModbus, Profibus and DeviceNet protocols, aswell as Modbus TCP, Profinet and EtherNet/IP .The modules can be easily installed evenat a later date.Furthermore, the IEC 61850 communicationmodule enables connection to automationsystems widely used in medium-voltage powerdistribution to create intelligent networks(smart grids). In addition, with an easy connectionthanks to the Ekip Com hub module, the circuitbreakers allow the system to be monitored viaABB Ability Energy and Asset Manager.The integrated display makes interaction withthe Ekip Touch/Hi-Touch an easy and intuitiveexperience for the user, and the embeddedBluetooth functionality allows fast interactionvia EPiC (electrification products intuitiveconfigurator), the new mobile application toconfigure and check the status of ABB low-voltagecircuit breakers.

MOLDED C A SE CIRCUIT BRE AKERS41Tmax XT rangeEkip Touch/Hi-TouchCurrent measurementand protectionTrip unitVoltage, power,energy measurementsVoltage, power,energy protectionsEmbedded functions*lEkip Touch LSIGlEkip Touch Measuring LSIllEkip Touch Measuring LSIGllEkip Hi-Touch LSIllllEkip Hi-Touch LSIGllll03Ekip Touch LSIl Default availableAdditional features* Please refer to the Tmax XT catalog 1SXU210248C0201 for more details.In 0010001200lll

42RE LIAG E AR NE X TRecord Plus FB and TEYMolded case circuit breakers03Record Plus FB and TEY circuit breakers complete the breakersoffering for the ReliaGear neXT panelboard.The Record Plus FB line features true one- and two-poleconstruction, has a double-break contact system for fastresponse and current limitation to help with arc flash andcoordination. This non-adjustable thermal-magnetic circuitbreaker up to 100 A offers four interrupt tiers — through100 kA at 480 V AC and 35 kA at 600/347 V AC.TEY also offers true one-pole construction up to 70 A andt

Seismic certification according to ICC-ES AC156 General characteristics Standard and certifications. 15 01 GENERAL CHARACTERISTICS Notes. 16 02 Panelboard details. 17 02 Panelboard details Panelboard details Int

Related Documents:

Catalog C-1 RT306V-TS RECEIVER: 470122 Catalog C-1: RT308V-TR RECEIVER 469996: Catalog C-1 RT3510V2S-KS RECEIVER: 470123 Catalog C-1: RT510V3S-KS RECEIVER 470124: Catalog C-1 RT612V3S-KS RECEIVER: 470125 Catalog C-1: RT616V3S-KS RECEIVER 470126: Catalog C-1 RT618V4S-KS RECEIVER: 470127 Catalog C-1: RT

College Catalog 2015-2016 College Catalog 2014-2015 College Catalog 2013-2014 College Catalog 2012-2013 College Catalog 2011-2012 College Catalog 2010-2011 Degree and Certificate Programs For each program, you will find information on. entry requirements, required and elective. courses, potential career and/or transfer opportunities, expected .

SACE Tmax XT application guide Common applications Available SACE Tmax XT frames SACE Tmax XT breaker ReliaGear neXT breaker Line side connection / termination Load side connection / termination Enclosure Tips Enclosed circuit breakers All frames - Lugs Lugs Fully assembled enclosed breaker also available in empower configurator.

2020–2021 UMGC Catalog. and represents changes and additions made after original publication. Refer to the . 2020–2021 Catalog. for information on all other programs, services, and policies. 2020 2021 UMGC Catalog . 2020 2021 UMGC Catalog . 2020 2021 Catalog . 2020 2021 Catalog . ABO

Consumer Door Hardware Catalog Volume 2012 2012 Commercial & Residential Door Hardware Catalog Volume 2012 Your Best Source For Quality Door Hardware Your Best Source For Quality Door Hardware S.Parke r Catalog S.Parke r Catalog SPH-Catalog

Program description from the 2004-2006 Graduate Catalog Biostatistics (Ph.D., M.S.) Program description from the 2004-2006 Graduate Catalog Breast Cancer Training Program Program Description from the 2004-2006 Graduate Catalog Business Administration (M.B.A.) Program description from the 2004-2006 Graduate Catalog C Cell Biology (Ph.D.) Catalog .

Step4 In the Work pane, click the Catalog Update Tasks tab. Step5 Click Activate Catalog. Step6 In the Activate Catalog dialog box, choose the capability catalog update that you want to activate from the Version to be Activated drop-down list. Step7 Click OK. Verifying thattheCapability Catalog IsCurrent Procedure Step1 In the Navigation pane, click Admin. Step2 Expand All Capability Catalog.

Alex Rider [7] Horowitz, Anthony Walker Books Ltd (2008) Rating: Product Description Alex Rider bites back. Splashing down off the coast of Australia, Alex is soon working undercover - this time for ASIS, the Australian Secret Service - on a mission to infiltrate the criminal underworld of South-East Asia: the ruthless world of the Snakehead. Faced with an old enemy and .