Tracer ControllersTracer MP580/581Programmable ControllersAugust 2006CNT-PRC002-EN

OverviewThe Tracer MP580 programmablecontroller is available factory-installed onthe following Trane air handlers: M-Series Climate Changer air handlers T-Series Climate Changer air handlers AireSystems custom air handlersThe Tracer MP581 programmablecontroller is available for field installationfor a variety of heating, ventilation, andair-conditioning (HVAC) applications.ApplicationsTracer MP580/581 controllers support awide variety of building controlapplications, including: Air-handler control Support of the LonMark Space Comfort Controller (SCC) profile and theDischarge Air Controller (DAC) profilefor air handlers Control of mechanical-room equipment, including cooling towers,pumps, boilers, and heat exchangers Supervisory control of an HVAC network for mid-sized buildings Nearly any control process needed ina commercial buildingInputs and outputsTracer MP580/581 controllers have thefollowing inputs and outputs (illustratedin Figure 8 on page 9): Twelve universal inputsSix binary outputsSix analog outputsOne static pressure inputYou can add up to four optionalexpansion modules to a Tracer MP580/581 controller. Each expansion moduleadds the following points: Six universal inputs Four binary outputs Four analog outputsFigure 9 on page 10 illustrates input andoutput wiring on an expansion module.Product modelsThe following Tracer MP580/581 modelsare available: Tracer MP580 factory-installed oncertain Trane air handlers Tracer MP581 in a NEMA-1 enclosure(with or without a touch screen) Frame-mounted Tracer MP581(the termination board and circuitboard in a plastic frame assembly)Touch-screen operator displays areavailable in the following configurations: Door-mounted operator display Portable operator display Stand-alone operator displaySee “Product models and accessories”on page 4 for more information. The following are trademarks or registered trademarks of their respective companies: Tracer, andTracer Summit, T-Series, Rover, Climate Changer, and AireSystems from Trane; LonTalk and LonMarkfrom Echelon Corporation. 2 2006 American StandardAll rights reservedCNT-PRC002-EN

ContentsOverview . . . . . . . . . . . . . . . . . . . . . . . . . . 2Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Product models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Inputs and outputs . . . . . . . . . . . . . . . . . . . . . . . . . . 2Product models and accessories . . . . . . . 4Tracer MP580/581 models . . . . . . . . . . . . . . . . . . . . 4Operator display models . . . . . . . . . . . . . . . . . . . . . 4Expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . 4Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Graphical programming . . . . . . . . . . . . . . . . . . . . . . 6Operator display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Engineered smoke control. . . . . . . . . . . . . . . . . . . . . 6Interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Network architecture . . . . . . . . . . . . . . . . 8Wiring diagrams . . . . . . . . . . . . . . . . . . . . 9Enclosure interior . . . . . . . . . . . . . . . . . . 11Dimensions . . . . . . . . . . . . . . . . . . . . . . . 12Specifications . . . . . . . . . . . . . . . . . . . . . 14Tracer MP580/581 . . . . . . . . . . . . . . . . . . . . . . . . . . 14MP581 NEMA-1 enclosure . . . . . . . . . . . . . . . . . . . 14Frame-mounted MP581 . . . . . . . . . . . . . . . . . . . . . 14Factory-installed MP580 . . . . . . . . . . . . . . . . . . . . . 14Operator display . . . . . . . . . . . . . . . . . . . . . . . . . . . 15EX2 expansion module . . . . . . . . . . . . . . . . . . . . . . 15CNT-PRC002-EN3

Product models andaccessoriesTracer MP580/581 modelsOperator display modelsExpansion moduleSeveral models of Tracer MP580/581controllers are available. Tracer MP581models are illustrated in Figure 1.Operator-display touch screens areavailable as options for all Tracer MP580/581 controllers. The operator-displaymodels are illustrated in Figure 2 onpage 5.You can use up to four EX2 expansionmodules to add extra points to a TracerMP580/581 controller. The expansionmodules communicate with thecontroller on an IEEE-485 I/O bus up to1000 ft (300 m) from the controller. TheEX2 expansion module is available intwo models:Tracer MP580 on Trane air handlersThe Tracer MP580 controller is availablepackaged with the following air handlers:The controller is factory wired to allsensors, actuators, valves, starters, andother items shipped with the air handler.Factory testing of connected pointshelps minimize field commissioningtime and expense.Door-mounted operator displayThe door-mounted operator displayworks with any Tracer MP581 or TracerAH541 controller. A retrofit kit isavailable to add an operator display to anexisting Tracer MP581. The retrofit kitincludes a complete enclosure door withan operator display mounted in it. Thedoor-mounted operator display is notavailable for factory-mounted TracerMP580 controllers.Frame-mounted Tracer MP581The frame-mounted Tracer MP581consists of a circuit board and atermination board mounted in a twopiece modular-frame assembly. Thismodular design allows the circuit boardto be stored separately while installationand wiring are completed. The framemounted model can be installed in newequipment or existing enclosures.Stand-alone operator displayThe stand-alone operator display isdesigned for permanent localconnection to a Tracer MP580/581 orAH540/541 controller. The stand-aloneoperator display includes a 7-day timeclock to provide scheduling for theassociated controller. The 10-foot(3 meter) connector cable can beextended up to 150 feet (46 meters).Tracer MP581 with NEMA-1 enclosureThe Tracer MP581 with enclosureconsists of the frame assemblymounted in an enclosure compliant withNational Electrical ManufacturersAssociation (NEMA) type-1 standards. Aline-to-low voltage transformer isincluded. The enclosure has a hingeddoor and plenty of room for input andoutput wiring. The assembly is UL-listed.Portable operator displayThe portable operator display isdesigned for temporary connection to aTracer MP580/581 or AH540/541controller. The operator-display touchscreen is mounted in a resin enclosure,which is placed in a padded, protectivecarrying case. A 10-foot (3 meter)connector cable is included. M-Series Climate Changer air handlers T-Series Climate Changer air handlers AireSystems custom air handlers EX2 module in a metal enclosure EX2 module with a plastic coverThe EX2 models are illustrated inFigure 3 on page 5.Table 1 lists the points available onTracer MP580/581 controllers and theexpansion modules. Refer to“Specifications” on page 14 for detailsabout each type of point.Table 1. Total points availableTracerMP580/581EachEX2(up to Analogoutputs6422Static pressure input101Type ofpointFigure 1. Tracer MP581 modelsTracer MP581 withoptional operator displayTracer MP581 withoutoperator displayFrame-mountedTracer MP5814CNT-PRC002-EN

Figure 2. Operator display modelsDoor-mounted operator displayfor Tracer MP581 controllersPortable operator displayStand-aloneoperator displayFigure 3. EX2 expansion modulesEX2 in metal enclosureEX2 with plastic coverNote: Expansion modules factory-installed withTracer MP580s consist of the circuit board only. Themodules shown here are available for field installation.CNT-PRC002-EN5

FeaturesGraphical programmingThe Tracer graphical programming (TGP)editor, shown in Figure 5 on page 7,eliminates the need for line-by-lineprogramming. The TGP editor i nclosure8EX2 modulewith plastic coverCNT-PRC002-EN

Wiring diagramsFigure 8 shows typical input and outputconnections to the Tracer MP581termination board. The Tracer MP581termination board uses screw terminals.The Tracer MP580 termination boarduses 0.25-inch quick-connect terminals.For wiring within a smoke controlsystem, see Applications Guide,Engineered Smoke Control System forTracer Summit, BAS-APG001-EN.Figure 9 on page 10 shows typical inputand output connections to the EX2expansion module.Figure 8. Wiring diagram for the Tracer MP580/581Powered output 1000 ft(300 m)0–10 Vdc outputLoad 500 Ω 1000 ft(300 m) 300 ft(100 m)Temperature sensor0–20 mA sensor 1000 ft(300 m)I/O bus to EX2expansion modules upto 1000 ft (300 m)CNT-PRC002-EN9

Figure 9. Wiring diagram for the EX2 expansion module3-wire, 0–20 mAsensor* 1000 ft(300 m)24 Vactransformer2-wire, 0–20 mAsensorPoweredoutput 1000 ft(300 m) 1000 ft(300 m)Temperature sensor 300 ft(100 m) 300 ft(100 m)AC poweredactuatorI/O bus to Tracer MP580 andEX2 expansion modulesup to 1000 ft (300 m)*Note: Or a 3-wire 0–10 Vdcsensor with a distancelimitation of 300 ft (100 m).10CNT-PRC002-EN

Enclosure interiorFigure 10 shows the interior of theTracer MP581 NEMA-1 enclosure.Significant space is available for wiringinputs and outputs. Wires should berouted after the optional pressuresensor is installed.Tracer MP580 enclosure configurationsare customized in the factory to meetcustomer requirements.For interior details of a Tracer MP581used in a smoke control system, seeApplications Guide, Engineered SmokeControl System for Tracer Summit, BASAPG001-EN.Figure 10. Tracer MP581 enclosure interiorLine-to-low voltagepower transformerMain circuit boardSpace for input andoutput wire-routingMounting locationfor optional staticpressure sensorTermination boardCNT-PRC002-EN11

DimensionsFigure 11 shows the dimensions of theTracer MP581 NEMA-1 enclosure.Figure 12 shows the dimensions of theframe-mounted Tracer MP581 controller.The dimensions of the operator displaymodels are listed in “Specifications” onpage 14.Figure 11. Tracer MP581 enclosure dimensionsFigure 12. Frame-mounted Tracer MP581 dimensions12CNT-PRC002-EN

Figure 13. EX2 plastic-cover module dimensions5.625 in.(143 mm)6.313 in.(160 mm)6.875 in.(175 mm)5.375 in. (137 mm)2 in. (51 mm)Figure 14. EX2 metal-enclosure module dimensions1.875 in.(48 mm)6.5 in.(165 mm)0.28 in.(7 mm)9 in.(25mm)9 in.(229 mm)7 in.(178 mm)10.37 in.(263 mm)with cover1 in.(25 mm)2.25 in.(58 mm)CNT-PRC002-EN10.25 in.(260 mm)without cover13

SpecificationsTracer MP580/581The specifications in this section applyto all Tracer MP580/581 models.Agency listings/complianceCE—Immunity (directive 89/336/EEC)EN 50090-2-2:1996Inputs and outputsTwelve universal inputsDry contact binary (including pulseaccumulation), 0–20 mA, 0–10 Vdc,linear resistance, or thermistor. Thefirst four inputs can be used directlywith resistance temperaturedetectors (RTDs).CE—Emissions (directive 89/336/EEC)EN 50090-2-2:1996EN 61000-3-2:1995EN 61000-3-3:1995Six binary outputsTracer MP580: 3 VA per orderedbinary output isolation relayTracer MP581: 12 VA at 24 Vacpowered relay contactsUL-864-UUKLEngineered smoke controlSix analog outputs0–10 Vdc or 0–20 mAStatic pressure inputSpecialized input for a Tranedifferential pressure sensor(5 Vdc, 0–5 in. wc)Analog-to-digital conversionResolution: 12 bitsDigital-to-digital conversionResolution: 12 bitsMicroprocessorMotorola MC68332 20 MHzMemoryRAM: 512 KROM: 2 MB FlashEEPROM: 256 KUL and C-UL listedEnergy management systemUL 916FCC approved: Part 15, Class ATracer MP581 withNEMA-1 enclosurePower requirementsNominal rating120/230 Vac; 50/60 Hz; 1 phaseVoltage utilization range120 Vac nominal: 98–132 Vac230 Vac nominal: 196–264 VacOperating environmentFrom 32 F to 122 F (0 C to 50 C)Humidity: 10–90% non-condensingStorage environmentTemperatureWithout display: From –58 F to 203 F(–50 C to 95 C)With display: From –13 F to 149 F(–25 C to 65 C)Humidity: 10–90% non-condensingTime clockIncluded with operator display; crystalcontrolled, super-capacitor backedDimensions16.5 in. 14.75 in. 5.5 in.(418 mm 373 mm 140 mm)BatteryNot required—backed by super capacitorfor 7 days under normal operatingconditions; all other programs backed bynon-volatile memoryMinimum clearances12 in. (30 cm) top, bottom, and right24 in. (60 cm) left36 in. (90 cm) frontWeight15 lb (7 kg)MountingWall-mounted with #10 (5 mm) screws14Frame-mountedTracer MP581Specifications not repeated here are thesame as for the NEMA-1 enclosure.Power requirementsNominal rating24 Vac; 50/60 Hz; 1 phaseVoltage utilization range24 Vac nominal: 19–30 VacOperating environmentFrom –40 F to 158 F (–40 C to 70 C)Humidity: 10–90% non-condensingDimensions10.25 in. 8 in. 3.5 in.(260 mm 203 mm 89 mm)Minimum clearances0.5 in. (1.3 cm) top, right, and front6 in. (15 cm) left (for I/O wiring)3 in. (8 cm) bottom (for comm wiring)Weight2 lb (1 kg)MountingRequires #8 (4 mm) screwsFactory-installedTracer MP580Specifications not repeated here are thesame as for the NEMA-1 enclosure.EnclosureOn M-Series air handlers, the TracerMP580 controller is mounted in agalvanized steel enclosure to minimizecosts, facilitate factory mounting, andmatch unit construction. On T-Series airhandlers, the Tracer MP580 controller ismounted in a control panel inside theunit.Operator displayOn M-Series air handlers, the operatordisplay can be mounted at the factory orshipped loose for field installation.Operator displays are shipped loose forT-Series air handlers. Door-mountedoperator displays are not available for theTracer MP580.CNT-PRC002-EN

Operator displayEX2 expansion moduleTouch screenVideo graphics adapter (VGA) backlitliquid crystal display (LCD) with touchscreen; 4.5 in. 3.4 in. (115 mm 86 mm) viewable area; resolution of320 240 pixelsInputs and outputsSix universal inputs; four binary outputs;four analog outputsOperating environmentFrom 32 F to 122 F (0 C to 50 C)Humidity 10–90% non-condensingPortable and stand-alone enclosuredimensions10.25 in. 8.75 in. 2.25 in.(260 mm 222 mm 58 mm)Mounting distance for stand-aloneoperator display10 ft (3 m) with attached cable;extendable to 150 ft (46 m) as describedin the installation sheet for the standalone operator display (3270 3338).Mounting distanceUp to 1000 ft (300 m) from controllerPower requirementsNominal rating24 Vac; 50/60 Hz; 1 phaseVoltage utilization range24 Vac nominal: 19–30 VacOperating environmentFrom –40 F to 158 F (–40 C to 70 C)Humidity 5–95% non-condensingStorage environmentFrom –40 F to 185 F (–40 C to 85 C)Humidity 5–95% non-condensingDimensionsMetal-enclosure module:10.25 in. 9 in. 2.25 in.(260 mm 229 mm 58 mm)Plastic-cover module:6.875 in. 5.375 in. 2 in.(175 mm 137 mm 51 mm)Minimum clearancesMetal-enclosure module:1 in. (25 mm) top, bottom2 in. (51 mm) left, right24 in. (610 mm) frontPlastic-cover module:1 in. (25 mm) top, bottom4 in. (102 mm) left, right, frontWeightMetal-enclosure module: 8 lb (4 kg)Plastic-cover module: 2 lb (1 kg)CNT-PRC002-EN15

TraneA business of American Standard Companieswww.trane.comFor more information, contact your local Traneoffice or e-mail us at comfort@trane.comLiterature Order NumberCNT-PRC002-ENFile NumberPL-ES-CNT-PRC002-0806SupersedesCNT-PRC002-EN March 2003Stocking LocationInlandTrane has a policy of continuous product and product data improvement and reserves the right tochange design and specifications without notice.

door and plenty of room for input and output wiring. The assembly is UL-listed. Operator display models Operator-display touch screens are available as options for all Tracer MP580/ 581 controllers. The operator-display models are illustrated in Figure 2 on page 5. Door-mounted operator display The door-mounted operator display

Related Documents:

Chapter 7: RBI 581 ISO Risk Plot 88. About the RBI 581 ISO Risk Plot 89 Access the Inventory Groups in a Process Unit 90 Access the RBI 581 ISO Risk Plot Page of a Functional Location 91 Access the RBI 581 ISO Risk Plot Page of an Asset 95 Access the RBI 581 ISO Risk Plot Page of a Corrosion Loop 96 Access the RBI 581 ISO Risk Plot Page of a .

Voice Tracer. Si le Voice Tracer ne fonctionne pas correctement, retirer les piles et les réinstaller. 2.2 Pour allumer le Voice Tracer Appuyer sur le bouton LECTURE/PAUSE et le maintenir quelques instants pour mettre le Voice Tracer en marche. Le Voice Tracer est en mode Arrêt 1 ou en mode Réglage de l’horloge 2. Le Voice Tracer 1 2 3 4

The Tracer BAS Operator Suite is a mobile app that allows you to monitor and manage buildings from virtually anywhere, giving you . Tracer SC is at the heart of aTracer building automation system.Tracer SC provides a web-based . manual system control.Tra

Tracer Summit WebOPS Version 1.2 Web-based access for the Tracer Summit building automation system. 2 BAS-PRC014-EN Tracer Summit WebOPS provides the ability to access the Tracer Summit building automation system (BAS) from any PC using a Web browser, such as Internet Explorer. WebOPS accesses

7 4. Installing OMEGA Tracer Note: Do not insert your software security key or any hardware until after you have completed the OMEGA Tracer installation. To start a new OMEGA Tracer installation, or to upgrade your existing OMEGA Tracer installation: 1. Insert the OMEGA Tracer CD in the CD-ROM drive. 2. When the Welcome screen appears, click on Next. (If the Welcome screen does not appear, go .

managed by a Tracer Summit BAS. The system consists of BCUs, UCMs, PC workstations, and Tracer Summit software. The Tracer Summit system uses high-speed, distributed processing on a local area network (LAN) to operate the components as one system. The Tracer Summit hardware architecture allows UCMs to be connected to BCUs. Multiple BCUs

The Tracer Summit Critical Control System package is an enhanced version of Tracer Summit software that provides complete environment management for FDA-regulated areas. See the Tracer Summit Critical Control System product catalog (BAS-PRC017-EN) for more information. Companion product Tracer Summit Energy Services is a

AngularJS Tutorial W3SCHOOLS.com AngularJS extends HTML with new attributes. AngularJS is perfect for Single Page Applications (SPAs). AngularJS is easy to learn. This Tutorial This tutorial is specially designed to help you learn AngularJS as quickly and efficiently as possible. First, you will learn the basics of AngularJS: directives, expressions, filters, modules, and controllers. Then you .