High-Performance M Series Multifunction DAQ For USBÐ 16 .

2y ago
5 Views
2 Downloads
273.73 KB
7 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Elisha Lemon
Transcription

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsNI USB-6221, NI USB-6225, NI USB-6229,NI USB-6251, NI USB-6255, NI USB-6259 Up to 80 analog inputs at 16 bits,1.25 MS/s (1 MS/s or 750 KS/sscanning) Up to 4 analog outputs at 16 bits,2.8 MS/s (2 µs full-scale settling) Up to 48 TTL/CMOS digital I/O lines(up to 32 hardware-timed at up to1 MHz) Two 32-bit, 80 MHz counter/timers Analog and digital triggering NI-PGIA 2 and NI-MCalcalibration technology for improvedmeasurement accuracy NI signal streaming for 4 high-speeddata streams on USB Power supply included 1-year warranty Additional warranty and calibrationservices availableFamilyNI 6251NI 6255NI 6259NI 6221NI 6225NI 8032168032Resolution(bits)161616161616Operating Systems Windows Vista (32- and 64-bit)/XP/2000Recommended Software LabVIEWLabVIEW SignalExpressLabWindows /CVIMeasurement StudioOther Compatible Software Visual Studio .NET C/C /C#Measurement ServicesSoftware (included) NI-DAQmx driver software Measurement & Automation Explorerconfiguration utility LabVIEW SignalExpress LEMax Rate(S/s)1.25 M1.25 M1.25 M250 k250 k250 kAnalogOutputs224224Analog OutputResolution (bits)161616161616Max Rate(S/s)2.86 M2.86 M2.86 M833 k833 k833 kRange (V) 10 10 10 10 10 10Digital I/O242448242448ClockedDIO18, up to 1 MHz18, up to 1 MHz132, up to 1 MHz18, up to 1 MHz18, up to 1 MHz132, up to 1 MHz1Counter222222Resolution(bits)323232323232DIO can be clocked at up to 1 MHz across the USB bus and up to 10 MHz using onboard regeneration.Table 1. Selection Guide for High-Performance M Series Multifunction DAQ for USBOverview and ApplicationsWith recent bandwidth improvements and new innovations fromNational Instruments, USB has evolved into a core bus of choicefor measurement and automation applications. National InstrumentsM Series devices for USB deliver high-performance data acquisition inan easy-to-use and portable form factor through USB ports on laptopcomputers and other portable computing platforms. NI designed anew and innovative patent-pending NI signal streaming technologythat enables sustained bidirectional high-speed data streams on USB.The new technology, combined with advanced external synchronizationand isolation, helps engineers and scientists achieve high-performanceapplications on USB.NI M Series high-performance multifunction data acquisition (DAQ)modules for USB are optimized for superior accuracy at fast samplingrates. They provide an onboard NI-PGIA 2 amplifier designed forfast settling times at high scanning rates, ensuring 16-bit accuracyeven when measuring all available channels at maximum speed.All high-performance devices have a minimum of 16 analog inputs,24 digital I/O lines, seven programmable input ranges, analog andDownloaded from Arrow.com.digital triggering, and two counter/timers. High-speed NI USB-625xand NI USB-622x M Series devices have two-year and one-yearcalibration intervals, respectively. USB M Series devices are idealfor test, control, and design applications including: Portable data logging – log environmental or voltage dataquickly and easily Field-monitoring applications Embedded OEM applications In-vehicle data acquisition Academic lab use – academic discounts availableNI Signal StreamingTo optimize the use of the Universal Serial Bus (USB) and deliverhigh-performance data acquisition, National Instruments created severalkey technologies to push the limits of USB throughput and latency.NI signal streaming combines three innovative hardware- and softwarelevel design elements to enable sustained high-speed and bidirectionaldata streams over USB. For more information, visit ni.com/usb.

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsUSB M Series for TestUSB M Series for OEMsFor test, you can use the M Series high-speed analog inputs and10 MHz digital lines with NI signal conditioning for applicationsincluding test, component characterization, and sensor measurement.High-speed USB-625x M Series devices are compatible with theNI SCC signal conditioning platform, providing amplification filtering andpower for virtually every type of sensor. This platform is also compliantwith IEEE 1451.4 smart transducer electronic data sheet (TEDS) sensors,which offer digital storage for sensor data sheet information.USB M Series multifunction DAQ devices also complement existingtest systems that need additional measurement channels. For higherchannel-count signal conditioning on USB, consider the NI CompactDAQor SCXI platforms.Shorten your time to market by integrating National InstrumentsOEM products in your design. Board-only versions of USB M SeriesDAQ devices are available for OEM applications, with competitivequantity pricing and software customization. The NI OEM Elite Programoffers free 30-day trial kits for qualified customers. Visit ni.com/oemfor more information.USB M Series for ControlUSB M Series digital lines can drive 24 mA for relay and actuatorcontrol. By clocking the digital lines as fast as 10 MHz (with onboardregeneration), you can use these lines for pulse-width modulation(PWM) to control valves, motors, fans, lamps, and pumps. With fourwaveform analog outputs, two 80 MHz counter/timers, and four highspeed data streams on USB, M Series devices can execute multiplecontrol loops simultaneously. High-speed USB-625x M Series devicesalso offer direct support for encoder measurements, protected digitallines, and digital debounce filters. With up to 80 analog inputs,32 clocked digital lines, and four analog outputs, you can executemultiple control loops with a single device.You can also create a complete custom motion controller by combiningUSB M Series devices with the NI SoftMotion Development Module.USB M Series for DesignFor design applications, you can use a wide range of I/O – from80 analog inputs to 48 digital lines – to measure and verify prototypedesigns. USB M Series devices and National Instruments LabVIEWSignalExpress interactive measurement software bring benchtopmeasurements to the PC. With NI LabVIEW SignalExpress, youcan quickly create design verification tests. The fast acquisition andgeneration rates of high-performance USB M Series high-speeddevices along with LabVIEW SignalExpress provide fast design analysis.You can convert your tested and verified LabVIEW SignalExpress projectsto LabVIEW applications for immediate M Series DAQ use, and bridgethe gap between test, control, and design applications.Recommended Training and ServicesAll M Series devices are available with additional warranty andcalibration services. For new data acquisition programmers,NI recommends the “Data Acquisition: 7 Steps to Success” tutorial kit.This tutorial kit helps shorten development time for data acquisitionapplications by describing the various stages of getting started with DAQincluding system definition, setup, test, and application programming.Recommended SoftwareNational Instruments measurement services software, built aroundNI-DAQmx driver software, includes intuitive application programminginterfaces, configuration tools, I/O assistants, and other tools designed toreduce system setup, configuration, and development time. NationalInstruments recommends using the latest version of NI-DAQmx driversoftware for application development in National Instruments LabVIEW,LabVIEW SignalExpress, LabWindows/CVI, and Measurement Studio. Toobtain the latest version of NI-DAQmx, visit ni.com/support/daq/versions.NI measurement services software speeds up your development withfeatures including: A guide to create fast and accurate measurements with no programmingusing DAQ Assistant Automatic code generation to create your application in LabVIEW;LabWindows/CVI; LabVIEW SignalExpress; and Visual Studio .NET,C/C /C#, or Visual Basic using Measurement Studio Multithreaded streaming technology for 1,000 times performanceimprovements Automatic timing, triggering, and synchronization routing to makeadvanced applications easy More than 3,000 free software downloads to jump-start your projectavailable at ni.com/zone Software configuration of all digital I/O features without hardwareswitches/jumpers Single programming interface for analog input, analog output, digitalI/O, and counters on hundreds of multifunction DAQ hardware devicesM Series devices are compatible with the following versions (or later) ofNI application software – LabVIEW, LabWindows/CVI, or MeasurementStudio versions 7.x or LabVIEW SignalExpress 2.x.BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)2Downloaded from Arrow.com.

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsRecommended Accessories(Mass-Termination Versions)Ordering InformationSignal conditioning is required for sensor measurements or voltageinputs greater than 10 V. NI SCC products, which are designed toincrease the performance and reliability of your data acquisition system,are up to 10 times more accurate than using terminal blocks alone.Refer to Table 2 for more information or visit ni.com/sigcon.Sensor/Signals ( 10 V)System DescriptionSCC Signal ConditioningSensor/Signals ( 10 V)System DescriptionScrew Terminal (Shielded) 2BNC ConnectivityScrew Terminal (Nonshielded) 2Screw Terminal (Shielded) 2, 31 H68-68-STerminal BlockSCC-68 1BNC-2110SCC-681SCB-68SCC signal conditioning.the integrated screw termination version of the USB DAQ device.use with Connector 1 on USB-6225 and USB-6255 devices.2 Consider3ForCableSH68-68-EPTable 2. Recommended AccessoriesNI USB-6221Screw terminal .779808-0P1NI USB-6225Screw terminal .779973-0P1Mass terminal.779974-0P1NI USB-6229Screw terminal .779810-0P1NI USB-6251Screw terminal .779627-0P1Mass terminal.779694-0P1NI USB-6255Screw terminal .779958-0P1Mass terminal.779959-0P1NI USB-6259Screw terminal .779628-0P1Mass terminal.779695-0P1Includes NI-DAQmx software.1 P is 1 (U.S. 120 VAC); 2 (Swiss 220 VAC); 3 (Australian 240 VAC);4 (Universal Euro 240 VAC); 6 (United Kingdom 240 VAC); 7 (Japanese 100 VAC)Includes data acquisition driver software, 1 m USB cable, and AC adapter.Board-Only Devices for OEMNI USB-6221 OEM (qty 1).195959-02NI USB-6225 OEM (qty 1).197294-01NI USB-6229 OEM (qty 1).195959-01NI USB-6251 OEM (qty 1).194929-03NI USB-6255 OEM (qty 1).197201-01NI USB-6259 OEM (qty 1).194929-01AccessoriesCablesSH68-68-EP (shielded) .184749-01SH68-68-S (for USB-62x5) .185262-01R6868 (unshielded ribbon) .182482-01Terminal Blocks and Signal Conditioning CarrierSCC-2345 carrier .777458-01SCC-68 screw-terminal block for mass termination .779475-01SCB-68 screw-terminal block for mass termination .776844-01BNC-2110 BNC terminal block for mass termination .777643-01Data Acquisition ServicesData Acquisition: 7 Steps to Success .779489-01BUY NOW!For complete product specifications, pricing, and accessoryinformation, call 800 813 3693 (U.S.) or go to ni.com/usb.BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)3Downloaded from Arrow.com.

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsNI 625x Specifications manuals at ni.com/manuals.Modes . Analog edge triggering, analogedge triggering with hysteresis,and analog window triggeringResolution . 10 bits, 1 in 1,024Specifications listed below are typical at 25 C unless otherwise noted.Analog OutputAnalog InputNumber of channelsUSB-6221/6225/6251/6255 .USB-6229/6259 .DAC resolution.Maximum update rateUSB-6221/6225/62291 channel .2 channels .3 channels .4 channels .USB-6251/6255/62591 channel .2 channels .3 channels .4 channels .Timing accuracy .Timing resolution .Output cations For complete specifications, see the NI 622x Specifications and theNumber of channelsUSB-6221/6251 .USB-6229/6259 .USB-6225/6255 .ADC resolution.Maximum sampling rateUSB-6221/6225/6229.8 differential or 16 single ended16 differential or 32 single ended40 differential or 80 single ended16 bits250 kS/s single channel,250 kS/s multichannel(aggregate)USB-6251/6259 . 1.25 MS/s single channel,1.00 MS/s multichannel(aggregate)USB-6255 . 1.25 MS/s single channel,750 kS/s multichannel(aggregate)Input coupling . DCInput rangeUSB-6221/6225/6229. 10, 5, 1, 0.2 VUSB-6251/6255/6259. 10, 5, 2, 1, 0.5, 0.2, 0.1 VMaximum working voltage for analog inputs(signal common mode). 11 V of AI GNDInput impedanceDevice onAI to AI GND. 10 GΩ in parallel with 100 pFAI– to AI GND. 10 GΩ in parallel with 100 pFDevice offAI to AI GND. 820 ΩAI– to AI GND. 820 ΩInput bias current. 100 pACrosstalk (at 100 kHz)Adjacent channels . -75 dBNonadjacent channelsUSB-6221/6225/6229. -90 dBUSB-6251/6255/6259. -95 dBInput FIFO size. 4,095 samplesScan list memory . 4,095 entriesData transfers . NI signal streaming on USB,programmed I/OAnalog Triggers (USB-625x Devices Only)Functions . Start TriggerReference TriggerPause TriggerSample ClockConvert ClockSample Clock TimebaseOutput coupling.Output impedance.Output current drive.Output FIFO size .Data transfers .2416 bits833 kS/s740 kS/s per channel666 kS/s per channel625 kS/s per channel2.86 MS/s2.00 MS/s per channel1.54 MS/s per channel1.25 MS/s per channel50 ppm of sample rate50 ns 10 V 10 V, 5 V, external referenceon APFI 0.1 DC0.2 Ω 5 mA8,191 samples sharedamong channels usedNI signal streaming,programmed I/OCalibration (AI and AO)Recommended warm-up time. 15 minutesCalibration intervalUSB-6221/6225/6229. 1 yearUSB-6251/6255/6259. 2 yearsDigital I/O/PFIStatic CharacteristicsNumber of channelsUSB-6221/6225/6251/6255 . 24 total, 8 (P0. 0.7 ),16 (PFI 0.7 /P1,PFI 8.15 /P2)USB-6229/6259 . 48 total, 32 (P0. 0.31 ),16 (PFI 0.7 /P1,PFI 8.15 /P2)Ground reference . D GNDDirection control . Each terminal individuallyprogrammable as input or outputPull-down resistor. 50 kΩ typical, 20 kΩ minimumBUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)4Downloaded from Arrow.com.

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsWaveform Characteristics (Port 0 Only)Phase-Locked Loop (PLL)Terminals usedUSB-6221/6225/6251/6255 .USB-6229/6259 .Port/sample sizeUSB-6221/6225/6251/6255 .USB-6229/6259 .Waveform generation (DO) FIFO.Waveform acquisition (DI) FIFO .DI sample clock frequency.DO sample clock frequencyRegenerate from FIFO.Streaming from memory.Data transfers .Number of PLLs. 1Reference signal . PXI STAR,PXI CLK10,RTSI 0.7 Output of PLL. 80 MHz timebase; other signalsderived from 80 MHz timebaseincluding 20 MHz and 100 kHztimebasesPort 0 (P0. 0.7 )Port 0 (P0. 0.31 )Up to 8 bitsUp to 32 bits2,047 samples2,047 samples0 to 1 MHz, system dependent0 to 10 MHz0 to 1 MHz, system dependentNI signal streaming,programmed I/OPFI/Port 1/Port 2 FunctionalityFunctionality. Static digital input,static digital output,timing input, timing outputTiming output sources. Many AI, AO, counter, DI,DO timing signalsDebounce filter settings . 125 ns, 6.425 µs, 2.56 ms,disable; high and low transitions;selectable per inputGeneral-Purpose Counter/TimersNumber of counter/timers . 2Counter measurements. Edge counting, pulse, semiperiod,period, two-edge separationPosition measurements . X1, X2, X4 quadrature encodingwith Channel Z reloading;two-pulse encodingOutput applications. Pulse, pulse train with dynamicupdates, frequency division,equivalent time samplingInternal base clocks . 80 MHz20 MHz0.1 MHzBase clock accuracy. 50 ppmInputs. Gate, Source, HW Arm, Aux, A,B, Z, Up DownData transfers . NI signal streaming,programmed I/OFrequency GeneratorNumber of channels. 1Base clocks . 10 MHz, 100 kHzDivisors. 1 to 16Base clock accuracy. 50 ppmOutput can be available on any PFI or RTSI terminalExternal Digital TriggersSource . Any PFI, RTSI, PXI TRIG,PXI STARPolarity . Software-selectable formost signalsAnalog input function . Start TriggerReference TriggerPause TriggerSample ClockConvert ClockSample Clock TimebaseAnalog output function . Start TriggerPause TriggerSample ClockSample Clock TimebaseCounter/timer functions. Gate, Source, HW Arm, Aux, A,B, Z, Up DownDigital waveform generation(DO) function . Sample ClockDigital waveform acquisition(DI) function. Sample ClockBus InterfaceUSB . Hi-Speed USB or full-speed USBNI signal streaming. 4 high-speed data streams;can be used for analog input,analog output, digital input,digital output, counter/timer 0,counter/timer 1Power RequirementsUSB power supply requirements . 11 to 30 VDC, 20 WPower Limits 5 V terminal. 1 A maxP0/PFI/P1/P2 and 5 V terminals combined . 2 A maxPower supply fuse. 2 A, 250 VPhysical RequirementsEnclosure dimensions (includes connectors)Screw termination . 26.67 by 17.09 by 4.45 cm(10.5 by 6.73 by 1.75 in.)Mass termination . 18.8 by 17.09 by 4.45 cm(7.4 by 6.73 by 1.75 in.)BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)5Downloaded from Arrow.com.

High-Performance M Series Multifunction DAQ for USB –16-Bit, up to 1.25 MS/s, up to 80 Analog InputsEnvironmentalOperating temperature .Storage temperature.Humidity .Maximum altitude.Pollution degree (indoor use only).CE Compliance0 to 45 ºC-20 to 70 ºC10 to 90% RH, noncondensing2,000 m2SafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1Note: For UL and other safety certifications, refer to the product labelor visit ni.com/certification, search by model number or product line,and click the appropriate link in the Certification column.Electromagnetic CompatibilityThis product is designed to meet the requirements of the followingstandards of EMC for electrical equipment for measurement, control,and laboratory use: EN 61326 EMC requirements; Minimum Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class ANote: For EMC compliance, operate this device according toproduct documentation.This product meets the essential requirements of applicable EuropeanDirectives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC)Note: Refer to the Declaration of Conformity (DoC) for this product forany additional regulatory compliance information. To obtain the DoCfor this product, visit ni.com/certification, search by model number orproduct line, and click the appropriate link in the Certification column.Waste Electrical and Electronic Equipment (WEEE)EU Customers: At the end of their life cycle, all products must besent to a WEEE recycling center. For more information about WEEErecycling centers and National Instruments WEEE initiatives, visitni.com/environment/weee.htm.Environmental ManagementNI is committed to designing and manufacturing products in anenvironmentally responsible manner. NI recognizes that eliminatingcertain hazardous substances from our products is beneficial not onlyto the environment but also to NI customers.For additional environmental information, refer to the NI and theEnvironment Web page at ni.com/environment. This page containsthe environmental regulations and directives with which NI complies,as well as any other environmental information not included inthis document.Management Methods for Controlling Pollution Caused byElectronic Information Products Regulation (China RoHS)BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)6Downloaded from Arrow.com.

NI Services and SupportNI has the services and support to meetyour needs around the globe and throughthe application life cycle – from planningand development through deploymentand ongoing maintenance. We offerservices and service levels to meetcustomer requirements in research,design, validation, and manufacturing.Visit ni.com/services.Training and CertificationNI training is the fastest, most certain route to productivity with ourproducts. NI training can shorten your learning curve, save developmenttime, and reduce maintenance costs over the application life cycle. Weschedule instructor-led courses in cities worldwide, or we can hold acourse at your facility. We also offer a professional certification programthat identifies individuals who have high levels of skill and knowledge onusing NI products. Visit ni.com/training.Professional ServicesOur NI Professional Services team is composed of NI applicationsand systems engineers and a worldwide National Instruments AlliancePartner program of more than 600 independent consultants andintegrators. Services rangefrom start-up assistance toturnkey system integration.Visit ni.com/alliance.OEM SupportWe offer design-in consulting and product integration assistance if youwant to use our products for OEM applications. For information aboutspecial pricing and services for OEM customers, visit ni.com/oem.ni.com 800 813 3693National Instruments info@ni.comLocal Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you accessto engineers who speak your language. NI delivers industry-leadingtechnical support through online knowledge bases, our applicationsengineers, and access to 14,000 measurement and automationprofessionals within NI Developer Exchange forums. Find immediateanswers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades toyour application development environment and higher levels of technicalsupport. Visit ni.com/ssp.Hardware ServicesNI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way touse your PXI or PXI/SCXI combination systems right out of the box.Trained NI technicians install the software and hardware and configurethe system to your specifications. NI extends the standard warranty byone year on hardware components (controllers, chassis, modules)purchased with FIS. To use FIS, simply configure your system onlinewith ni.com/pxiadvisor.Calibration ServicesNI recognizes the need to maintain properly calibrated devices forhigh-accuracy measurements. We provide manual calibrationprocedures, services to recalibrate your products, and automatedcalibration software specifically designed for use by metrologylaboratories. Visit ni.com/calibration.Repair and Extended WarrantyNI provides complete repair services for our products. Express repairand advance replacement services are also available. We offerextended warranties to help you meet project life-cycle requirements.Visit 1-101-D 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com,NI CompactDAQ, NI SoftMotion, RTSI, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation.Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent fromNational Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.Downloaded from Arrow.com.

National Instruments, USB has evolved into a core bus of choice for measurement and automation applications. National Instruments . Screw Terminal (Shielded)2, 3 SH68-68-S SCB-68 1Includes SCC signal conditioning. 2Consider the integrated screw termination version of the USB DAQ device.

Related Documents:

Dell Multifunction Printer E515dw Dell Multifunction Printer E515dn Dell Multifunction Printer E514dw User’s Guide Regulatory Model: Dell E515dw / E515dn / E514dw

VPN Router High-Performance, Multifunction Connectivity Product Overview The Cisco RV130W Wireless-N Multifunction VPN Router is an easy-to-use, flexible, high-performance device well suited for small businesses. It delivers highly secure, broadband, wired and wir

200 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com Full-Featured E Series Multifunction DAQ Data Acquisition and Signal Conditioning Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs

SMB_Dual Port, SMB_Cable assembly, Waterproof Cap RF Connector 1.6/5.6 Series,1.0/2.3 Series, 7/16 Series SMA Series, SMB Series, SMC Series, BT43 Series FME Series, MCX Series, MMCX Series, N Series TNC Series, UHF Series, MINI UHF Series SSMB Series, F Series, SMP Series, Reverse Polarity

Optional Features Equitrac Express , Equitrac Office , YSoft SafeQ , other network accounting solutions available through various Xerox Business Innovation Partners Xerox WorkCentre 7830i/7835i/ 7845i/7855i Color Multifunction Printer The WorkCentre 7800i Series Color Multifunction Printer is

Xerox WorkCentre 7800 Series Multifunction System Transform the way you work. WorkCentre 7830/7835/7845/7855 A3 Colour Multifunction System TITLE: X_26337_W78BR-01EC LANGUAGE: Englis

Xerox WorkCentre 7220/7225 Multifunction Printer Meet today’s tasks, build tomorrow’s opportunities. Xerox WorkCentre 7220/7225 A3 Colour Multifunction Printer TITLE: X_27187_W

NI Multifunction I/O Devices provide a combination of analog I/O, digital I/O, and counter/timer . USB-6001 8 no 20 kS/s 14 bits 26 mV 2 5 kS/s 13 1 ST USB-6000 8 no 10 kS/s 12 bits 26 mV 0 - 4 1 ST . Page 4 ni.com Multifunction I/O Table 2. NI P