INSITE 8.1.1 Features NotesThe latest INSITE information can be found on the website at http://insite.cummins.comFor technical support, please send an email to servicetoolsupport@cummins.com or call800-433-9341, Option 2 within the U.S. Outside the U.S call 812-377-8136, Option 2.To locate the nearest distributor, visit the Distributor locator.Table of Contents123456789General Information . 21.1Upgrade capability . 2New Base Features . 22.1ECM Code Search . 22.2ECM Templates . 22.3Programmable Datalink Device (PDD) Download . 22.4Enhanced Simulator Mode. 22.5Enable Cummins Inc. Data Collection . 22.6J1939 Datalink Messages . 32.7INSITE for Cense . 3New Diagnostic Tests . 33.1Cylinder Bank Cutout Test. 33.2Starter Intake Air Heater Override Test . 3New Advanced ECM Data . 34.1Aftertreatment SCR System Health Monitor . 3New Features and Parameters . 45.1User Adjustable Fuel Economy Switch Multiplexing. 45.2Driver Operation Interlock . 45.3Load Management . 45.4Starter Intake Air Heater . 4Languages Supported: . 4Operating System Support. 5Recommended PC Requirements . 5Minimum PC Requirements . 61

1 General Information1.1 Upgrade capabilityUpgrade from INSITE 8.0.0 or higher.2 New Base Features2.1 ECM Code SearchFollowing an ECM code search, there is an option to view the calibration history ofthat ECM code. Added to this ECM Calibration Revision History window is the optionto export the history information into a comma separated value (csv) file format.2.2 ECM TemplatesTemplates created with INSITE 8.1.0 or later can be modified using the ECMTemplate Editor. Right click on the template and select Edit Template. After theadjustable parameters are modified, the template can be saved as the currenttemplate or saved as a new template. If a value entered is not within the limits, therewill be a pop up showing the limit for that parameter.2.3 Programmable Datalink Device (PDD) DownloadWhen downloading a PDD, the option to right click and select Autodetect to find thehardware part number of the connected device has been added.2.4 Enhanced Simulator ModeThe INSITE simulator mode, which contains all Features, Special Features, andTests, can be accessed without having to activate an INSITE license.2.5 Enable Cummins Inc. Data CollectionThis functionality enables or disables the Cummins Inc. data collection in Tools Options Work Orders. This allows Cummins to collect information for emissionscompliance reporting and for product development.2

2.6 J1939 Datalink MessagesThis functionality provides Source Address, PGN, SPN, and the values of the J1939datalink messages if supported in the calibration.2.7 INSITE for CenseCalibration download can be performed with a valid Basic license with INSITE forCense only.3 New Diagnostic TestsNOTE: These will only be displayed if they are supported by the calibration.3.1 Cylinder Bank Cutout TestThis test can activate cylinder cutout on the selected group of cylinders or deactivateall cylinder cutouts.3.2 Starter Intake Air Heater Override TestThis test is used to validate the Starter Intake Air Heater operation by turning theheater on and off.4 New Advanced ECM DataNOTE: These will only be displayed if they are supported by the calibration.4.1 Aftertreatment SCR System Health MonitorThis feature provides the user with the capability to monitor several different engineparameters in order to manage heat in the engine. This feature also provides thecapability to reset the coke accumulation and hydrocarbon adsorption counters.3

5 New Features and ParametersNOTE: These will only be displayed if they are supported by the calibration.5.1 User Adjustable Fuel Economy Switch MultiplexingThis feature provides the ability to allow the ECM to receive the User Adjustable FuelEconomy input from the datalink.5.2 Driver Operation InterlockThe feature is designed for forklift applications. Based on input status, the feature willprovide driver output and lamp control.5.3 Load ManagementThis feature provides the ability to command an override of the rated load to manageheat in the engine.5.4 Starter Intake Air HeaterThis feature provides the ability to enable the heating elements in the engine intakeair stream.6 Languages Supported:EnglishLimited Translation:Chinese ekIndonesianItalianHungarianJapaneseKorean4

dishTurkish7 Operating System SupportWindows 7 32-bit and 64-bitWindows 8 32-bit and 64-bitWindows 8.1 32-bit and 64-bitNOTE: INSITE 8.1 is not supported on the following Operating Systems:Windows 7 Starter Edition or Basic EditionWindows 8 RT EditionWindows 8.1 RT EditionWindows 10 32-bit and 64-bit (will be included in a future INSITE release)8 Recommended PC RequirementsCOMPONENTREQUIREMENTS (Recommended for new hardware purchases)Platform:Operating System:Processor:RAM Memory:Hard Drive:Media Device:Display:Keyboard:Pointing Device:IBM or 100% CompatibleWindows 8 32-bit2.1 GHz or greater dual-core4 GB or greater2 GB or greater available disk spaceDual Layer - Double Density DVD-ROMMinimum Resolution 1024 x 768101 Key EnhancedWindows Compatible DevicePC’s that will be used for Virtual College training will require multimedia andsound capabilityAdobe Acrobat Reader v9.0 and laterWindows CompatibleMultimedia:Other Software:Printer:InternetConnection:Available Ports:DSL / Broadband high-speedTwo USB 2.0 Ports5

9 Minimum PC RequirementsCOMPONENTREQUIREMENTS (for minimum performance)Platform:Operating System:Processor:RAM Memory:Hard Drive:Media Device:Display:Keyboard:Pointing Device:Multimedia:Other Software:Printer:InternetConnection:Available Ports:IBM or 100% CompatibleWindows 7 32-bit2 GHz2 GB2 GB available disk spaceDVD-ROMMinimum Resolution 1024 x 768101 Key EnhancedWindows Compatible DeviceAny Windows Compatible Sound DeviceAdobe Acrobat Reader v9.0 and laterWindows Compatible DeviceDSL / Broadband high-speedSee datalink adapter manufacturer for port specificationsJEM Created: INSITE 8.1.1 June 2015Document 6733-NEWF-07 Version 2.0.06

The INSITE simulator mode, which contains all Features, Special Features, and Tests, can be accessed without having to activate an INSITE license. 2.5 Enable Cummins Inc. Data Collection This functionality enables or disables the Cummins Inc. data collection in Tools Options Work Orders.

Related Documents:

Customer InSite Instructions This is a reference to upload files to your InSite project. 1. Login to InSite Go to insite.publicationprinters.com or publicationprinters.com to access the InSite login. 2. Select the customer If your user is assigned to multiple customers you can select the correct one under the customer dropdown. After you

KODAK INSITE Customer InSite Instructions Call 303-936-0303 or email your Account Manager for more information. Option #3: Groups of Pages InSite will separate your multi-page PDFs into individual pages and append a position number at the end of the file name based upon the number of pages within the document.

DecisionSpace InSite Anywhere Quick Start Guide 3 Quick Start Guide Select a well and run 1. Access the Job Selection page using one of these methods: If you are not logged on, log on to DecisionSpace InSite Anywhere . If you are already logged on, select Options Job/Units from the main window. Click OK in the message dialog box to confirm.

15004085 - Hose Assembly (-4 HP, 84 in long) Engine QSM - Electronic Diagnostic Tooling 15500622 - Insite Kit - Includes Insite program and inline adaptor. Note; 15500716 Deutsch Cable should be added to this kit. 15500623 - Insite Program (Individual Spare) 15500624 - Inline Connector (Individual Spare) 15500716 - Deutsch Cable (Individual Spare)

What is InSite Prepress Portal? The Kodak InSite Prepress Portal system is a web portal to the prepress environment that lets printers and their customers work with print jobs over the Internet. Prepress Portal helps to manage the proofing, correction, and approval process so that it is more efficient. Logging on and off 1.

IPP 9.0 - InSite Prepress Portal Quick Start Guide Logging on and off - 6 2 Logging on and off 1. Open a web browser, and type the address (URL) of the Prepress Portal server. 2. Type your user name and password, select a language, and click Login. 3. The Kodak InSite Prepress Portal window appears. 4.

down by when the work was performed, individual employee performance, machine utilization, or net yield. A payroll/HR system may give after the fact reporting on overtime hours, but not prevent workers from logging unauthorized off shift work. factory Insite labor and process m

12 dimana manajer menggeser laba tahun berjalan dengan kemungkinan laba di masa mendatang. Sedangkan menurut Kustono (2009), perataan laba dapat didefinisi sebagai suatu cara yang dipakai manajemen untuk mengurangi variabilitas laba di antara deretan jumlah laba yang timbul karena adanya perbedaan antara jumlah laba yang seharusnya dilaporkan dengan laba yang diharapkan (laba normal). 2.2.2 .