Product CatalogPackaged Rooftop Air ConditionersVoyager with e-Flex TechnologyCooling & Gas/Electric12½–17½ Tons, 60 HzJune 2015RT-PRC056B-EN

IntroductionPackaged Rooftop Air ConditionersThrough the years, Trane has designed and developed the most complete line of PackagedRooftop products available in the market today. Trane was the first to introduce the Micro—microelectronic unit controls—and has continued to improve and revolutionize this designconcept.The ReliaTel control platform offers the same great features and functionality as the originalMicro, with additional benefits for greater application flexibility.Voyager continues to provide the highest standards in quality and reliability, comfort, ease ofservice, and the performance of Trane light commercial products.Trane customers demand products that provide exceptional reliability, meet stringentperformance requirements, and provide a payback based on life cycle costs. Trane delivers withVoyager with eFlex technology.Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTelcontrols, computer-aided run testing, and Integrated Comfort Systems. So, whether you’re thecontractor, the engineer, or the owner, you can be certain Voyager products are built to meetyour needs.CopyrightThis document and the information in it are the property of Trane, and may not be used orreproduced in whole or in part without written permission. Trane reserves the right to revise thispublication at any time, and to make changes to its content without obligation to notify any personof such revision or change.TrademarksTrane and the Trane logo, CompleteCoat, Frostat, Integrated Comfort Systems, Voyager, ReliaTel,Tracer, Tracker, eFlex are trademarks of Trane in the United States and other countries. BACnet isa registered trademark. All trademarks referenced in this document are the trademarks of theirrespective owners.Revision SummaryRT-PRC056B-EN (19 June 2015) Added Multi Zone Variable Air Volume and Horizontal Low Leak Economizer. Updated Features & Benefits, Model Number Description, Performance Data, Electrical Data,and Mechanical Specifications. 2015 Trane All rights reservedRT-PRC056B-EN

Table of ContentsFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Standard and Optional Features at a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory or Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45556Outstanding Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Variety of Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Factory or Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19ReliaTel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Single Zone Variable Air Volume (Single Zone VAV) Control . . . . . . . . . 23Variable Air Volume Applications (Traditional VAV) . . . . . . . . . . . . . . . . 27Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Cooling Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Air Delivery Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Model Number Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Economizer Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Zone Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Communication Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Jobsite Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Factory or Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74RT-PRC056B-EN3

Features and BenefitsVoyager has the features and benefits that make it first class in the light commercial rooftop market.Designed with input from field contractors and engineers, its U-shaped airflow performance isoutstanding.Standard and Optional Features at a GlanceStandard Features 42” throwaway filters5 year Limited Compressor Warranty5 year Limited Heat Exchanger1 year Limited Parts WarrantyAnti-Short Cycle TimerBelt Drive MotorsColored and Numbered WiringCrankcase HeatersDedicated AirflowDischarge Air Temperature SensorDischarge Line ThermostatEasy Access Low Voltage Terminal Board (LTB)eFlex Variable Speed TechnologyEnhanced DehumidificationFoil-Faced and Edge Captured InsulationFrostat High Efficiency Drum and Tube Heat ExchangerHigh Efficiency Gas Heat with Hot Surface IgnitionHigh Pressure CutoutIAQ Sloped Condensate Drain PanLiquid Line Refrigerant DrierLow Ambient Cooling to 0 FMicrochannel Type Condenser CoilsOperating Charge of R-410APhase MonitorProvisions for Through-the-Base Gas and Condensate Drain ConnectionsQuick Access PanelsQuick Adjust Idler Arm PulleyReliaTel Microprocessor ControlsReliaTel Options ModuleSingle Point PowerSingle Side ServiceSingle Zone Variable Air Volume (SZ VAV)Standardized ComponentsThermal Expansion ValveU-shaped Airflow PatternVariable Frequency DriveRT-PRC056B-EN

Features and BenefitsFactory Installed Options 2” MERV 8 or MERV 13 Pleated Filters4 with Filter Removal Tool5” Color Touchscreen Human InterfaceCO2 Sensor Wiring (Wiring Only)Complete Coat Microchannel Condenser CoilCondensate Overflow SwitchFault Detection Diagnostics (FDD)High Short Circuit Current Rated (SCCR) Electrical Subsystem12Hinged Access DoorsModulating Gas Heat Furnace with a 2.5:1 Turndown RatioMultiple Zone Variable Air VolumePowered or Unpowered Convenience Outlet3Stainless Steel Drain PanStainless Steel Heat Exchanger with 10 Year Warranty4Supply and/or Return Air Smoke Detector7Through the Base Electrical Access9Through the Base Electrical with Circuit Breaker8, 9Through the Base Electrical with Disconnect Switch5, 8, 9Through the Base Gas PipingFactory or Field Installed Options BACnet Communications Interface1Barometric Relief1Clogged Filter/Fan Failure Switch4Electric Heaters 4, 6, 9Indoor Fan Motor Shaft Grounding RingLonTalk Communications Interface (LCI)4Low Leak Economizer - DownflowOversized Motors4Reference or Comparative Enthalpy2, 4Standard Economizer - Downflow1Tool-less Hail Guards4Field Installed Options RT-PRC056B-ENCO2 SensorDigital Display Zone SensorHigh Altitude KitHigh and Low Static Drive KitsHumidity SensorLow Leak Economizer - Downflow & HorizontalLP Conversion KitPowered ExhaustRemote PotentiometerRoof Curb (Downflow Only)Standard Economizer - HorizontalTrane Communications Interface (TCI)4Ventilation Override AccessoryWireless Zone SensorZone Sensors and Remote Zone Sensors5

Features and BenefitsNote: Most Factory Installed Options (FIOPS) available for Downflow Air Discharge units only.Please verify with ordering system for availability.Note: Explanation of Notes located in “Model Number Description,” p. 33.Other Benefits Cabinet Design Ensures Water IntegrityEase of Service, Installation and MaintenanceMixed Model Build Enables “Fastest in the Industry” Ship Cycle TimesOutstanding Airflow DistributionReliaTel Controls BenefitsRigorous TestingUnmatched Product SupportOutstanding Standard FeaturesAnti-Short Cycle TimerProvides a 3 minute minimum “ON” time and 3 minute “OFF” time for compressors to enhancecompressor reliability by assuring proper oil return.Colored and Numbered WiringSave time and money tracing wires and diagnosing the unit.CompressorsTrane eFlex variable speed scroll compressorsare matched with a specially designed variablefrequency drive that allows a modulating ratio of upto 4:1. Our eFlex compressors are paired withfixed speed compressors such that the units arecapable of continuous capacity modulation from10% to 100%. By design, unit combined airflow andcompressor capacities overlap to minimize thefrequent cycling between stages typical ofcompeting designs. This allows for unmatchedcontrol of leaving air temperatures to meet spaceloads.The eFlex compressors also include brushlesspermanent magnet motors designed to operate athigher efficiency along with reducing thecompressor motor speed and cycling results insignificant part load energy savings. This makesunits with eFlex compressors the most efficientproducts in their class at part load.Controls—ReliaTelReliaTel microprocessor controls provide unit control for heating, cooling and ventilating utilizinginput from sensors that measure indoor and outdoor temperature and other zone sensors. ReliaTelalso provides outputs for building automation systems and expanded diagnostics. For a completelist of ReliaTel offerings, refer to “Other Benefits,” p. 16.Conversionless UnitsThe dedicated design units (either downflow or horizontal) require no panel removal or alterationtime to convert in the field — a major cost savings during installation. Horizontal units comecomplete with duct flanges so the contractor doesn’t have to field fabricate them. These ductflanges are a time and cost saver.6RT-PRC056B-EN

Features and BenefitsCrankcase HeatersThese band heaters provide improved compressor reliability by warming the oil to preventmigration during off-cycles or low ambient conditions. These are standard on all Voyager models.Discharge Air Temperature SensorProvides true discharge air sensing in heating models.Discharge Line ThermostatA bi-metal element discharge line thermostats installed as a standard feature on the discharge lineof each system. This standard feature provides extra protection to the compressors against highdischarge temperatures in case of loss of charge, extremely high ambient and other conditionswhich could drive the discharge temperature higher.Easy Access Low Voltage Terminal BoardFoil Faced InsulationVoyager’s Low Voltage Terminal Board isexternal to the electrical control cabinet. It isextremely easy to locate and attach thethermostat wire and test operation of all unitfunctions. This is another cost and time savinginstallation feature.All panels in the evaporator section of the unithave cleanable foil-faced insulation. All edgesare either captured or sealed to ensure noinsulation fibers get into the airstream.Enhanced Dehumidification with eFlex Every Ultra High Efficiency unit is equipped with Enhanced Dehumidification, which operates whenconnected to a humidity sensor. With Enhanced Dehumidification, the ReliaTel control reduces theminimum indoor airflow and modulates the eFlex compressor operation to allow for additionalmoisture removal of the return air. When dehumidification is required without cooling, the ReliaTelcontrol brings the compressors to an appropriate capacity to remove moisture without overcoolingthe space providing efficient humidity control.Frostat This capillary bulb embedded in the face of the evaporator coil monitors coil temperature toprevent evaporator icing and protect the compressor. Recommended for applications with lowleaving air temperatures, low airflow and/or high latent load applications.Heat Exchanger—Drum and TubeThe cabinet features a drum and tube heatexchanger (pictured right) that ismanufactured using aluminized steel withstainless steel components for maximumdurability.The requirement for cycle testing of heatexchangers is 10,000 cycles by ANSI Z21.47.This is the standard required by both UL andAGA for cycle test requirements.RT-PRC056B-ENForced Combustion BlowerNegative Pressure Gas ValveHot Surface Ignitor7

Features and BenefitsTrane requires the design to be tested to 2½ times this current standard. The drum and tube designhas been tested and passed over 150,000 cycles, which is over 15 times the current ANSI cyclingrequirements. The negative pressure gas valve is used in the standard furnaces. This is one of ourunique safety features. Modulating heaters use a pressure switch to ensure that the blower motoris operating before the gas valve is allowed to open.The forced combustion blower supplies pre-mixed fuel through a single stainless steel burnerscreen into a sealed drum where ignition takes place. It is more reliable to operate and maintainthan a multiple burner system. Modulating furnaces contain a metal fiber material to ensure properflame distribution at low fire. The hot surface ignitor is a gas ignition device which doubles as asafety device utilizing a continuous test to prove the flame. The design is cycle tested at the factoryfor quality and reliability. Our gas/electric rooftops exceed all California seasonal efficiencyrequirements and perform even better than the California NOx emission requirements.Low Ambient CoolingAll Voyager microprocessor units have cooling capabilities down to 0 F as standard.Low Voltage ConnectionsThe wiring of the low voltage connections to the unit andthe zone sensors is as simple as 1-1, 2-2, and 3-3. Thissimplified system makes it easy for the installer to wire.Microchannel Condenser CoilMicrochannel Flat TubeHeader(top removed)Ribbon FinMicrochannel coils have better heat transferperformance due to flat streamlined tubes withsmall ports, and metallurgical tube-to-fin bond.Microchannel condenser coil can reduce systemrefrigerant charge by up to 50% (potential LEEDcredit) because of smaller internal volume, whichcan lead to better compressor reliability. Compactall aluminum microchannel coils also help to reducethe unit weight. All-aluminum constructionimproves re-cyclability. Galvanic corrosion is alsominimized due to all aluminum construction. Strongaluminum brazed structure provides better finprotection.MotorsAll indoor fan motors are belt drive as standard.Pressure CutoutsLow and high pressure cutouts are standard on all Voyager models.Phase MonitorVoyager features a three-phase line monitor module that protects against phase loss, phasereversal and phase unbalance. It is intended to protect compressors from reverse rotation. It hasan operating input voltage range of 190–600 Vac, and LED indicators for ON and FAULT. There areno field adjustments and the module will automatically reset from a fault condition.8RT-PRC056B-EN

Features and BenefitsQuick-Access PanelsRemove three or more screws for access to thestandardized internal components and wiring.Quick-Adjust Slider PlateWith the Quick-Adjust Slider Plate (pictured right), thebelt and sheaves can be quickly adjusted withoutmoving the mounted fan motor. The result is a majorsavings in time and money.ReliaTel Options Module (RTOM)The RTOM monitors the supply fan proving, cloggedfilter, supply air temperature, exhaust fan setpoint,dehumidification setpoint, supply air tempering,frostat and smoke detector.Single Point PowerA single electrical connection powers the unit.Single Side ServiceSingle side service is standard on all units.Single Zone VAV - One Zone Variable Air Volume ModeNote: Single Zone VAV is designed to be used with a zone sensor. If a unit is configured for SingleZone VAV operation but is connected to a thermostat, the control will revert to multi-speed(2-Speed) indoor fan control and staged compressor control. This drastically reduces theenergy savings available with this design.Single zone VAV is designed for use in single zone applications like gymnasiums, auditoriums,manufacturing facilities, retail box stores, and any large open spaces, where there is a lot ofdiversity in the load profile. Single Zone VAV (SZ VAV) is an ideal replacement to "yesterday's"constant volume (CV) systems, by reducing operating costs while improving occupant comfort.SZ VAV systems combine Trane application, control and system integration knowledge to exactlymatch fan speed with cooling and heating loads, regardless of the operating condition. Tranealgorithms meet/exceed ASHRAE 90.1- 2010, SZ VAV energy-saving recommendations, and thoseof CA Title 24. The result is an optimized balance between zone temperature control and systemenergy savings. Depending on your specific application, energy savings can be as much as 20%.Note: Building system modeling in energy simulation software like TRACE is recommended toevaluate performance improvements for your application.SZ VAV is fully integrated into the ReliaTel Control system and is available today. It provides thesimplest and fastest commissioning in the industry through proven factory-installed, wired, andtested system controllers. All control modules, logic and sensors are factory installed, and testedto assure the highest quality and most reliable system available. This means no specialprogramming of algorithms, or hunting at the jobsite for sensors, boards, etc. that need to beinstalled in the field. Single zone VAV is a quick and simple solution for many applications and isavailable from your most trusted rooftop VAV system solution provider - Trane.Sloped Drain PansEvery Voyager unit has a non-corrosive, sloped drain pan made of pre-painted steel and standardon all units.RT-PRC056B-EN9

Features and BenefitsStandardized ComponentsComponents are placed in the same location on all Voyager units. Familiarize yourself with oneVoyager and you are familiar with every Voyager. Due to standardized components throughout theVoyager line, contractors/owners can stock fewer parts.Thermal Expansion ValveThermal expans

service, and the performance of Trane light commercial products. Trane customers demand products that provid e exceptional reliability, meet stringent performance requirements, and provide a payback based on life cycle costs. Trane delivers with Voyager with eFlex technology.

Related Documents:

Catalog C-1 RT306V-TS RECEIVER: 470122 Catalog C-1: RT308V-TR RECEIVER 469996: Catalog C-1 RT3510V2S-KS RECEIVER: 470123 Catalog C-1: RT510V3S-KS RECEIVER 470124: Catalog C-1 RT612V3S-KS RECEIVER: 470125 Catalog C-1: RT616V3S-KS RECEIVER 470126: Catalog C-1 RT618V4S-KS RECEIVER: 470127 Catalog C-1: RT

College Catalog 2015-2016 College Catalog 2014-2015 College Catalog 2013-2014 College Catalog 2012-2013 College Catalog 2011-2012 College Catalog 2010-2011 Degree and Certificate Programs For each program, you will find information on. entry requirements, required and elective. courses, potential career and/or transfer opportunities, expected .

2020–2021 UMGC Catalog. and represents changes and additions made after original publication. Refer to the . 2020–2021 Catalog. for information on all other programs, services, and policies. 2020 2021 UMGC Catalog . 2020 2021 UMGC Catalog . 2020 2021 Catalog . 2020 2021 Catalog . ABO

Consumer Door Hardware Catalog Volume 2012 2012 Commercial & Residential Door Hardware Catalog Volume 2012 Your Best Source For Quality Door Hardware Your Best Source For Quality Door Hardware S.Parke r Catalog S.Parke r Catalog SPH-Catalog

Program description from the 2004-2006 Graduate Catalog Biostatistics (Ph.D., M.S.) Program description from the 2004-2006 Graduate Catalog Breast Cancer Training Program Program Description from the 2004-2006 Graduate Catalog Business Administration (M.B.A.) Program description from the 2004-2006 Graduate Catalog C Cell Biology (Ph.D.) Catalog .

Step4 In the Work pane, click the Catalog Update Tasks tab. Step5 Click Activate Catalog. Step6 In the Activate Catalog dialog box, choose the capability catalog update that you want to activate from the Version to be Activated drop-down list. Step7 Click OK. Verifying thattheCapability Catalog IsCurrent Procedure Step1 In the Navigation pane, click Admin. Step2 Expand All Capability Catalog.

baldor catalog no. ao smith/century catalog no. baldor catalog no. ao smith/century catalog no. baldor catalog no. ao smith/century catalog no. baldor catalog no. c777 pcl3514m c802 l3515 c907 vl3504 c916 vl3507 c926 vl3510 e100 m3116t e1006 m3116t-5 e1007 m3154t-5 e1009 m3550t e1010 m3120t e1012 m3155t e1013 m3158t e1015 em3116t e1016 em3154t

weekend, your pet will be kept at the airport due to customs duty hours. If possible pets should arrive during weekday/daytime hours to prevent unnecessary stress for the pet or owner. Commercial Airline Transport . If flying commercially, contact the airline prior to purchasing tickets to ensure pets will actually be able to fly on the day of travel (e.g. ask about the airline’s regulations .