SPF-290AS SPF Testing AndUV Transmittance Analyzer SystemWavelength Selection SolutionsPart Number: 210135Revision Level: D

SPF Testing Analyzer SystemSPF-290AS Analyzer for In-Vitro SPF Testing andUltraviolet Protection Factor (UPF) AnalysisThe SPF-290AS is a recording UV spectrophotometer designedand optimized for the determination of SPF values on a variety ofsunscreen and cosmetic products, reducing the need (and cost!)for in-vivo testing.Covering both the UVB and UVA spectral regions, the systemautomatically scans from 290 to 400nm, accumulating and storingdata at intervals of 1, 2 or 5nm. The monochromatic protectionfactor (MPF) is determined for each of the selected wavelengthsand is used to calculate the SPF value, using solar irradianceand erythemal constants that are programmed into the softwarebut which can be easily modified. Liquids, creams and gels areapplied in small “dabs” or “spots” to the Transpore Tape or othersubstrate, with the pipette supplied with the system. The substrateis placed on an open metal frame. The sample is spread lightly andevenly over a 50 cm2 area at 2 μl/cm2, equivalent to in-vivo testing.Quartz plates are available from Solar Light for sprays and otherdifficult samples. The high correlation between the SPF-290AS ’sin-vitro measurements and in-vivo test results gives you confidencethat the instrument will be a reliable guide to product performance.The SPF-290AS can provide reliable results on the most difficultsamples.An easy-to-use testing methodology combined with reproducibleresults opens the door to efficient and low cost experimental designtechniques for formulation optimization. This will result in fasterformulation and lower development cost due to a reduction in theneed for extensive in-vivo panel studies.Validation KitSolar Light offers a Comprehensive Test Plate for use with theSPF-290AS and WinSPF software. The test plate is designedto provide the user with a clear understanding of how their SPF290AS analyzer is performing. The test plate contains severaloptical filters that are measured by the SPF-290AS and theresults are compared to NIST traceable factory measurements.Equipped with this tool, users will not spend time performing testson an analyzer that is in need of repair nor will they spend moneyfor repairs that are not necessary.In addition to the test plate, the Validation Kit contains: TransporeTM TapeHard Carrying Case(10) Syringes with tipsSet of 3 PMMA PlatesPMMA Plate HolderCalibration Plate Assembly(2) standard formulations:- 1 oz. of 8% Homosalate- 1 oz. of Colipa Standard

SPF-290AS Analyzer SystemSPF-290AS SPECIFICATIONSWavelength Range290 – 400 nmWavelength Accuracy0.2% (0.58 nm – 0.80 nm)WavelengthReproducibility0.25 nm(Range Specified By International Methods)Spectral FWHM Bandwidth 1.66 nmAbsorbance0 – 3.2 A (Dual Doped PMMA Method)SPF Measurement Range1 – 100 Scan TimeAs Little As 24 SecondsWavelength Step Interval1 nm, 2 nm, or 5 nm (User selectable)LampPower Stabilized Xenon CW125 W(operated at 75 W)DetectorHigh Sensitivity Multialkali side-on PMTSample PositioningAutomated X-Y StagePower Options110V AC, 60 Hz or 220V AC, 50 HzDesigned to Meet the Needs of SPF AssaysSL/SPF-290AS 06/2021Specifications subject to change without notice.Ultraviolet (UVB) and near ultraviolet (UVA)radiation is provided by a 125W CW Xenonarc lamp.A horizontal sample area permits testing ofliquids, creams, emulsions and sprays.An integrating sphere placed just belowthe sample collects light scattered bythe product and its supporting substrate,increasing measurement accuracy.SPF-290AS Sample Handling and Support MediaLiquids, creams and gels are applied in small “dabs” or “spots” to theTranspore Tape or other substrate, with the pipette supplied with the system.The substrate is placed on an open metal frame. The sample is spread lightlyand evenly over a 50cm2 area at 2 μl/cm2, equivalent to in-vivo testing.Quartz plates are available from Solar Light for sprays and other difficultsamples.

Data Acquisition & AnalysisSPF-290AS NEW with WinSPF Software Full compliance to FDA2011 and ISO24443 Export data direct to ISO Spreadsheet Includes calculations and displays screens incompliance with AATCC 183, BS EN 13758-1,GBT18830-2009, and NZS 4399 UPF fabrictest methods. USB connectivity Includes UVA Protection Factor and ErythemalProtection Factor calculations. Updated Help System Comes with audio visual training aids andintuitive computerized modules designedto assist the operator with everything fromspreading a sample to routine maintenance.Data can be acquired in approximately 20 seconds. Results displayed in easy to read format.Software Features Calculate and Print SPF ValuesBoth Tabular and Graphical FormatsBoots Star Ratings CalculatedCreate Formulation Assays of Up to 36 ScansDisplay MPF and Absorbance Values Photo-Stability TestingCalculate Area Under the CurveCritical Wavelength CalculationUVA/UVB RatioComplete On-Line Help Menu View Scans IndividuallyCalculates TNUV StandardSupports FDA UVA In-Vitro Test ProcedureUPF per AATCC 183, BS EN 13758-1,GBT18830-2009, and NZS 4399 150 Spreadsheet Export FunctionComputer Controlled Sampling StageThere are two modes of computer controlled operation: Programmed reading of up to 12 locations (Autoscan) Time based measurements (photo-stability)Autoscan mode offers two methods of choosing up to 12 sampling locations.The operator can either specify the positions to be read or the computercan generate them randomly. Once set, the operation, data collection andreporting are performed automatically. The stage moves the sample on theholder into the light beam, takes the measurements, moves to the nextposition and continues until all the measurements have been completed.Time-based (photo-stability) measurements monitor the SPF values for asample at a user specified position against time. The effects of drying andexposure to air and light on a sample can be easily evaluated, making itparticularly suitable for photostability testing. The system’s computer providesa controlled repeatable time base for measurements.X-Y Sampling StageComputation of statistics for multiple assays is provided by the software. Reduces the overall cost of testing,The Computer Controlled X-Y Sampling Stage: Frees technicians for other tasks, Improves the repeatability and accuracy ofmeasurements, and Facilitates photo-stability testing

Software Analyzer System AutomationSPF-290AS Correlation Between SPF-290AS and In-Vivo SPF TestingThe high correlation between the unit’s in-vitro measurements and in-vivotest results gives you confidence that the instrument will be a reliable guideto product performance.The chart shows data comparisons for a variety of commercially availableproducts including: Physical Sunscreens Sprays Waterproof Sunscreens and Stick FormulationsKorea Food & Drug Administration Qualify the SPF-290Sas an Alternative Method to in-vivo Testing“The results of this study for correlation between the in-vivo SPF and in-vitroSPF measured using SPF-290 analyzer are .The in vitro SPF test methodwill be used as an alternative method for in vivo SPF and a new test item forquality control sunscreens.”– Drug Evaluation Department, Korea Food & Drug Administration,5 Nokbun-dong, Eunpyung-gu, Seoul, KoreaOver 300 Customers Worldwide Avon L’Oreal Whitehall Robins BASF Mary Kay Bayer Clairol Merck S/C/Johnson Elizabeth Arden Revlon Bristol-Myers Squibb Estee Lauder Rohm & Haas Tanning Research Good Housekeeping Proctor & Gamble Pfizer ISP Unilever Boots (the Chemist) Johnson & Johnson Andrew Jergens Amway Lever Bros Helene Curtis And Many More

SPF Testing Analyzer System SPF-290AS Analyzer for In-Vitro SPF Testing and Ultraviolet Protection Factor (UPF) Analysis The SPF-290AS is a recording UV spectrophotometer designed and opti

Related Documents:

The support and marketing staff of Ricoh Sales companies, including Ricoh family group . B264 Aficio 3035 SP/SPF/Spi/G 8035 SP/SPF/Spi/G DSm735 SP/SPF/Spi/G LD235 B265 Aficio 3045 SP/SPF/Spi/G 8045 SP/SPF/Spi/G DSm745 SP/SPF/Spi/G LD245 B276 Aficio MP 1600 9016 DSm716 LD316 B277 Aficio MP 2000 9021d DSm721d LD320 .

information concerning the design and installation of construction details for quality SPF roof systems. This introduction is intended to supplement the special notes on the individual construction details. Construction details are provided for the following SPF roof system types: SPF roof systems with protective coatings SPF re-cover roof systems with protective coatings Construction .

uLtra SHeer Liquid SPF 70 Superior sun protection layers invisibly under makeup. Water-resistant (80 minutes) and non-comedogenic. BeaCH DeFenSe Lotion SPF 30 and 70 BeaCH DeFenSe Spray SPF 30 and 70 Provides beach-strength sun protection with HELIOPLEX technology; defends skin against signs of water damage. Water-

B. Roofing applicator must have a minimum of 2 years work experience with SPF and must have installed a minimum of 250,000 sq. ft. experience with SPF roofing systems, with projects of a similar scope and nature. C. CRFC strongly recommends participation in a Pre-Bid Conference to discuss any details not covered within the specification.

Raffle, H. (2018, April). Introduction to the SPF‐PFS Strategic Plan Map. Athens, OH: Voinovich School of Leadership and Public Affairs at Ohio University. Step 4: Transfer the Information onto Ohio’s SPF‐PFS Strategic Plan Map Your coalition will submit one Strategic Plan

The Spray Polyurethane Foam (SPF) Advantage: Understand why SPF is an excellent insulation choice for your home or building. Insulating a new home or improving the comfort and energy performance of an existing one is a decision that will have a lasting impact. It’s imp

- RICOH MP C6004 SP, RICOH MP C5504 SP, RICOH MP C5504A SP, RICOH MP C4504 SP, RICOH MP C4504A SP Above MFP with Fax Unit Type M20. - RICOH MP C6004 SPF, RICOH MP C5504 SPF, RICOH MP C4504 SPF Make clear to the sales representative that you purchase the MFP as CC-certified product. 1.3 TOE Overview

The American Revolution: a historiographical introduction he literary monument to the American Revolution is vast. Shelves and now digital stores of scholarly articles, collections of documents, historical monographs and bibliographies cover all aspects of the Revolution. To these can be added great range of popular titles, guides, documentaries, films and websites. The output shows no signs .