Technical Data TD01005006EEffective January 2018Supersedes August 2009Eaton’s SPD Series for integration intoelectrical distribution equipmentContentsDescriptionPageIntroduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standards and certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Feature package options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remote display mounting option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Catalog number selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Technical support information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22223335677

Technical Data TD01005006EEffective January 2018Eaton’s SPD Series for integration into electrical distribution equipment IntroductionEaton’s SPD Series surge protective devicesEaton’s SPD Series surge protective devices are the latest and mostadvanced ULT 1449 3rd Edition certified surge protectors. Units areavailable integrated within Eaton electrical assemblies, includingpanelboards, switchboards, motor control centers, switchgear, andbus plugs. Side-mount versions of the SPD Series are also availablefor installation external to an electrical assembly. Application ofSPD Series units throughout a facility will ensure that equipmentis protected with the safest and most reliable surge protectivedevices available.SPD Series units are available in all common voltages andconfigurations and also in a variety of surge current capacityratings from 50 through 400 kA. Three feature package optionsare also available to choose from. The breadth of the SPD Series’features, options, and configurations ensures that the correct unitis available for all electrical applications, including service entrances,distribution switchboards, panelboards, and point-of-use applications.ApplicationsThe SPD Series is available as an integrated device within thefollowing Eaton electrical assemblies: Panelboards Switchboards Motor control centers Switchgear Automatic transfer switches Bus plugsFeatures Uses thermally protected metal oxide varistor (MOV) technology 20 kA nominal discharge current (In) rating (maximum ratingassigned by UL) 50 through 400 kA surge current capacity ratings Three feature package options 200 kA short circuit current rating (SCCR) 10-year warrantyStandards and certifications 2UL 1449 3rd Edition recognized component for the United Statesand Canada, covered by Underwriters Laboratories certificationand follow-up serviceEATON www.eaton.comSPD Series unit integrated within an Eaton panelboard

Technical Data TD01005006EEaton’s SPD Series for integration into electrical distribution equipment Effective January 2018 Feature package optionsThe SPD Series provides users with the option of selectingbetween three feature packages. These feature packages arethe basic, standard, and standard with surge counter. The properfeature package can be selected based on the requirements of theapplication or specification.Existing SPD Series units previously installed without a remotedisplay also have the capability of mounting their displays remotelyfrom the device. Complete remote display kits are available thatcontain all items required to mount the display remotely, includingthe remote display cable. Remote display kits are available in 4, 8,and 12 foot cable length options.Table 3. Remote display kitsTable 1. Feature package comparisonFeatureBasicStandardwith surgeStandard counterSurge protection using thermallyprotected MOV technologyDual-colored protection statusindicators for each phaseDual-colored protection status indicatorsfor the neutral-ground protection modeAudible alarm with silence button44444444444Form C relay contact44EMI/RFI filtering, providing up to 50 dB ofnoise attenuation from 10 kHz to 100 MHzSurge counter with reset button44DescriptionCatalog NumberRemote display kit with 4 ft remote display cableRemote display kit with 8 ft remote display cableRemote display kit with 12 ft remote display cableSPDRDKIT04SPDRDKIT08SPDRDKIT12For the dimensions of the cutout required to accommodate theremote display panel, see Figure 1 below.Dimensions5.38 (136.7)2.69 (68.3)4Remote display mounting optionThe SPD Series offers the option of mounting its display remotelyfrom the device. This is useful for applications where OEMs or otherintegrators would like to embed the unit within a piece of equipmentand still be able to view its display.9.38(238.3)8.90(226.1)SPD Series unit catalog numbers ending with ‘B’ (refer tocatalog number configuration on page 7) should be ordered forapplications where the display is to be mounted remotely. Theseunits include the SPD Series unit and the remote display panel.In addition to the unit itself, a remote display cable will have tobe purchased. Remote display cables are available in 4, 8, and12 foot lengths.Table 2. Remote display cablesDescriptionCatalog number4 ft remote display cable8 ft remote display cable12 ft remote display cableSPDRDCAB04SPDRDCAB08SPDRDCAB12NNote: Integrated units factory-installed with Eaton switchgear assemblies donot require the purchase of a remote display cable. The cable is provided andall required mounting is performed at the factory.4.69(119.1)4.45(113.0)4x R0.06 (1.6)2.53 (64.3)6x 0.13 (3.3)5.06 (128.6)Figure 1. Dimensions of the cutout required to accommodatethe optional remote display panelEATON www.eaton.com3

Technical Data TD01005006EEaton’s SPD Series for integration into electrical distribution equipment Effective January 2018Dimensions (continued)Mounting 8.80 (223.5)4.40 (111.8)0.04 (1.0) 2.02 (51.2)4x Mounting 0.19 (4.8)Bus 0.34 (8.6)3x 0.22 (5.6)Bus Mounting2.02 (51.2)0.95 (24.1)Mounting3.42 (86.9)5.40 (137.2)4.66 (118.4)3.42 (86.9)2.52 (64.0)3.45 (87.6)3.42 (86.9)Terminals 8.74 (222.0)9.50 (241.3)0.26 (6.6)4x 0.22 (5.6) Mounting4x #10–32 x 0.38 DPBrass TerminalsFigure 2. Dimensions of 50 kA through 200 kA integrated unitsMounting 8.80 (223.5)3.42 (86.9)4x Mounting 2.52 (64.0)3.42 (86.9)Mounting3.42 (86.9)5.40 (137.2)4.66 (118.4)1.71 (43.4)4.85 (123.2)5.78 (146.8)Figure 3. Dimensions of 250 kA through 400 kA integrated units4EATON www.eaton.comTerminals 8.74 (222.0)4x 0.22 (5.6) Mounting9.50 (241.3)4x #10–32 x 0.38 DPBrass Terminals

Technical Data TD01005006EEaton’s SPD Series for integration into electrical distribution equipment Effective January 2018 Performance dataANSI/UL 1449 3rd Edition voltage protection ratingsVoltage protection rating (VPR) data is included for both direct bus mounted units (catalog number ending with ‘A’) and units interfaced tothe electrical assembly via a circuit breaker (catalog number ending with ‘B,’ ‘C,’ or ‘J’). Direct bus mounted units are available for installationwithin Eaton PRL1a, 2a, 3a, and 3E panelboards only.Table 4. 50 kA direct bus mounted integrated unit VPRTable 8. 50 kA circuit breaker interfaced integrated unit VPRProtection modeProtection modeVoltage codeL-NL-GN-GL-LVoltage codeL-NL-GN-GL-L240S208Y and 220Y400Y and /AN/A5001000100020002500900200025001000240S208Y and 220Y400Y and /AN/A70012001200200025001200200025001200Table 5. 80–100 kA direct bus mounted integrated unit VPRTable 9. 80–100 kA circuit breaker interfaced integrated unit VPRProtection modeProtection modeVoltage codeL-NL-GN-GL-LVoltage codeL-NL-GN-GL-L240S208Y and 220Y400Y and 00250090018002500240H500600500900240S208Y and 220Y400Y and /A70010001000180025001200200025001000Table 6. 120–200 kA direct bus mounted integrated unit VPRProtection modeVoltage 002500600N/AN/AN/A50090018002500800Table 7. 250–300 kA circuit breaker interfaced integrated unit VPRProtection mode240S208Y and 220Y400Y and 480Y600Y240D480D600D240HL-N600 600 10001500N/AN/AN/A600 /AN/AN/A600Protection modeL-L240S208Y and 220Y400Y and 480Y600YVoltage codeTable 10. 120–200 kA circuit breaker interfaced integratedunit VPRVoltage codeL-NL-GN-GL-L240S208Y and 220Y400Y and /A60010001000180025001000180025001000Table 11. 400 kA circuit breaker interfaced integrated unit VPRProtection modeL-L10001000180025001000180025001000a L-N VPR for 250–300 kA units containing the standard and standard with surge counterfeature packages is 600 V. L-N VPR for units containing the basic feature package is 700 V.All other VPR numbers reported in all tables represent the VPR for all feature packages.Voltage codeL-NL-GN-GL-L240S208Y and 220Y400Y and A60010001000180025001000180025001000EATON www.eaton.com5

Technical Data TD01005006EEaton’s SPD Series for integration into electrical distribution equipment Effective January 2018SpecificationsTable 12. SPD Series specificationsDescriptionSpecificationSurge capacity ratings availableNominal discharge current (In)50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase20 kAShort circuit current rating (SCCR)200 kASPD typeBasic feature package Type 1 (can also be used in Type 2 applications)Standard and standard with surge counter feature packages Type 2Single split phase voltages available120/240Three-phase Wye system voltages available120/208, 127/220, 230/400, 277/480, 347/600Three-phase Delta system voltages available240, 480, 600Input power frequency50/60 HzPower consumption (basic units):208Y, 220Y, 240S, 240D, and 240H voltage codes400Y, 480Y, and 480D voltage codes600Y and 600D voltage codesPower consumption (standard and standard with surge counter units):208Y, 220Y, 240S, 240D, and 240H voltage codes400Y, 480Y, and 480D basic voltage codes600Y and 600D voltage codesProtection modes0.5 W1.1 W1.3 W0.6 W1.7 W2.1 WSingle split phase. . . . . . . . . . . .Three-phase Wye. . . . . . . . . . .Three-phase Delta. . . . . . . . . . .Three-phase high-leg Delta . . .L-N, L-G, N-G, L-LL-N, L-G, N-G, L-LL-G, L-LL-N, L-G, N-G, L-LMaximum continuous operating voltage (MCOV):240S, 208Y, 220Y, and 240H MCOV400Y and 480Y MCOV600Y MCOV240D MCOV480D MCOV600D MCOVPorts150 L-N, 150 L-G, 150 N-G, 300 L-L320 L-N, 320 L-G, 320 N-G, 640 L-L420 L-N, 420 L-G, 420 N-G, 840 L-L320 L-G, 320 L-L640 L-G, 640 L-L840 L-G, 840 L-L1Operating temperature–40 F to 122 F (–40 C to 50 C)Operating humidity5% through 95%, noncondensingOperating altitudeUp to 16,000 ft (5000 m)Seismic withstand capabilityMeets or exceeds the requirements specified in IBCT 2006, CBC 2007, and UBCT Zone 4Weight50–200 kA units approximately 3.5 lbs (1.6 kg)250–400 kA units approximately 7.0 lbs (3.2 kg)Form C relay contact ratings150 Vdc or 125 Vac, 1A maximumForm C relay contact logicPower ON, normal state—NO contact open, NC contact closedPower OFF or fault state—NO contact closed, NC contact openEMI/RFI filtering attenuationUp to 50 dB from 10 kHz to 100 MHzAgency certifications and approvalsUL 1449 3rd Edition recognized component for the U.S. and CanadaUL 1283 (Type 2 SPDs only)Warranty10 years6EATON www.eaton.com

Technical Data TD01005006EEaton’s SPD Series for integration into electrical distribution equipment Effective January 2018 Catalog number selectionTable 13. SPD Series catalog number configuration for units integrated into electrical distribution equipmentSPD 250 480D 2 JSeriesSPD SurgeprotectivedevicekA rating050 50 kA per phase080 80 kA per phase100 100 kA per phase120 120 kA per phase160 160 kA per phase200 200 kA per phase250 250 kA per phase300 300 kA per phase400 400 kA per phaseApplication—integrated units Voltage code240S 120/240 single split-phase208Y 120/208 wye (4W G)220Y 127/220 wye (4W G)400Y 230/400 wye (4W G)480Y 277/480 wye (4W G)600Y 347/600 wye (4W G)240D 240 delta (3W G)480D 480 delta (3W G)600D 600 delta (4W G)240H 240 high-leg delta (4W G)on 'B' phase ABCJ Panelboards (PRL1a, 2a, 3a, 3E), direct bus mounted Switchgear (includes remote display) Panelboards (PRL1a, 2a, 3a, 3E, 4), switchboards, busway Motor control centersFeature package1 Basic2 Standard3 Standard surge counterExample: SPD250480D2J SPD Series, 250 kA per phase, 480D voltage, standard feature package, motor control center applicationa Please consult the factory for 240 high-leg Delta (4W G) applications with high leg on ‘C’ phase.b Units used in PRL1a, 2a, 3a, and 3E panelboard applications are available in 50–200 kA ratings only. Use the ‘C’ option for PRL1a, 2a, 3a, and 3E panelboard applications when unit is connectedthrough a circuit breaker.If you have any questions or need additionalinformation, please contact the Eaton TechnicalResource Center at 1-800-809-2772,option 4, option 2. You may also submit inquiriesvia e-mail: surgeprotection@eaton.comEATON www.eaton.com7

Technical Data TD01005006EEffective January 2018Eaton’s SPD Series for integration into electrical distribution equipment Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com 2018 EatonAll Rights ReservedPrinted in USAPublication No. TD01005006E / Z20365January 2018Eaton is a registered trademark.All other trademarks are propertyof their respective owners.

Eaton’s SPD Series surge protective devices . Eaton’s SPD Series surge protective devices are the latest and most . advanced ULT 1449 3rd Edition certified surge protectors . Units are available integrated within Eaton electrical assemblies, including panelboards, switchboards, motor co

Related Documents:

Eaton Char-Lynn 4000 Series 10 Eaton Char-Lynn 6000 Series 11 Eaton Char-Lynn 10,000 Series 12 Eaton Char-Lynn Spares 13 Eaton Xcel XLH Series 15 Eaton Xcel XLS Series 16 Eaton Xcel XL2 Series 17 Eaton Xcel Spares 18 Eaton Char-

Eaton 15284 Beltsville, MD Eaton 02750 Bethel, CT Eaton 97484, 16780 Glenolden, PA Eaton 09790, 17472, 72121 Grand Rapids, MI Eaton 86090 Irvine, CA Eaton 62983, 90166 Jackson, MS Eaton 99643, 76050, 52906 Los Angeles, CA Eaton 77842 Warwick, RI Essex Cryogenics 19062 Saint Louis, MO Essex Industries 0HFY6 Saint Louis, MO Extant 22830 Melbourne .

For more information visit: www.eaton.com IB01602009E Instruction Booklet Page4 Effective: January 2020 ATC-300 Automatic Transfer Switch Controller 1.5.2 Standard and Optional Features A variety of programmable features are available with the ATC 300 Controller to meet a File Size: 936KBPage Count: 28Explore furtherO & M Manual for the EATON ATC-300 Automatic Transfer .www.eaton.comAll Product Manuals - Eatontaa-ups.eaton.comOperators Manual ASCO SERIES 300 Automatic Transfer .www.ascopower.comEaton automatic transfer switch brochurewww.eaton.comATC-300 Power Series Transfer Switchwww.generac.comRecommended to you based on what's popular Feedback

4 EATON PERFORMANCE PRODUCTS Differential Application Guide Eaton ELocker Eaton Detroit Truetrac Eaton Posi. No matter your application, Eaton Performance has a differential to meet your needs. Product On Road. Off-Road Drag Racing; Circle Track Restoration: Street and Muscle

Eaton SPC Series surge protection EATON www.eaton.com Introduction Eaton’s SPC Series surge protective devices are UL 1449 4th Edition-certified surge protectors. Application of SPC Series units throughout a facility will ensure that equipment is protected with the safest and most reli

Pumps & Motors Eaton Piston Pump Controls Eaton Control Products Eaton Packaged Systems* 4 EATON Power Products M-HYOV-MC003-E1 February 2013 . Gear pumps are used in drive trains, hydrostatic transmissions, open and closed circuit piston applications,

4 EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com Company overview Eaton is the leading source of fusible circuit protection solutions in the global marketplace. Eaton

Eaton 9390 UPS (40–80 kVA) Installation and Operation Manual Eaton 9390 UPS (100–160 kVA) Installation and Operation Manual Eaton 9395 UPS (225–275 kVA) Installation and Operation Manual Eaton 9395 Plus 1 UPS (225–275 kVA) Installation and Operation Manual E