Braun ThermoScan PRO 6000 ThermometerCindy Kuiper Global Marketing Manager

PRO 6000 Key Marketing Contacts Melissa Davis, Marketing Product Information SpecialistChris Daly, US&C Thermometry Sr. SpecialistKristin Daly, Global Marketing Sr. Specialist, ThermometryCindy Kuiper, Global Product Marketing Mgr., ThermometryJamie Wood, US&C Marketing Mgr.

Braun PRO 6000 Offering New Product that addresses some of the topcustomer complaints of PRO4000– Improved accuracy (low reading)– Probe cover detection– Ability to wipe device with new, harsher cleaningsolutions Protects 35M probe cover business– Braun PRO4000 probe cover loses patentprotection next year

PRO 6000 Launch SchedulePerfecTemp Enabled US&C Sept 2015Without PerfecTemp (CE pending for this new feature expected Q4) EMEI Jul 2015 Latin America– Venezuela Q4 2015– Rest of LA Q2 2016 Australia Sept 2015 Asia Jul 2015– Singapore Q2/3 2016– China Q4 2016 ROW Q4 2015

Braun PRO 6000 Features

Braun PRO 6000 Key Features PerfecTemp Technology (US&C only Sept 2015)– Corrects for shallow placement of probe in ear– Collects data from 8 different sources– achieved a 35% reduction in low readings offby 0.5F or more from the referencetemperature compared to Braun algorithmreading Proven Legacy Technologies– ExacTemp and pre-heated sensor and tip Better User Experience– Backlit display, rear display, dedicated buttonsfor pulse timer, C/F conversion, memory– Durable, cleaning friendly design andmaterials (impact resistant Terluran GP-22)– Tested to 1.5 meter drop (ISO standards/Pro4000 is1 meter)

Two Choices of Protective Cradles Small 1-box cradle is the mostportable and holds 20 PC Large 2-box cradle has the mostcapacity by holding 40 PC and theunit can be wall mounted for security Both cradles are compatible with theCharging Station Both cradles are compatible with the1.8m (6ft) and 2.7m (9ft) securitytethers

New Security Options Large Cradle Mounting Option– Large 2-box cradle can be temporarily or permanently screwed toa wall surface– Mounting screws included for typical situations Optional Security Tether– 1.8m (6ft) and 2.7m (9ft) security tethers screw to the cradle andthermometer (Allen wrench and screws included in kit)– Tether also attaches to Connex Spot Monitor Electronic Time Security– Select 1-12 hours operation until unit locks– To unlock, dock the device and cradle into the Charging Station(will unlock on any Station)– Requires Charging Station (or Connex Spot Monitor) and ServiceTool software to activate security function

Superior Recharging System Redesigned Recharging Battery– Up to 700 measurements from a full charge– 350,000 total measurements per battery– Fully recharges in approximately 3-4 hours from empty(device and on CSM)– 3 year rechargeable battery part warranty– Fast Charge Nickel–metal hydride battery type Redesigned Charging Stations– More robust and larger charging/communication contactconnections when thermometer is docked– Works with the small and large cradles, and when a tether isattached to the thermometer and cradle– Also holds a sleeve of 200 probe covers

PRO 4000 vs. PRO 6000Additional DifferencesList Price 217 250/ 255 (small/large cradle)

Braun PRO 6000 Integration with LAVS Connex Spot Monitor– Integrated PRO 6000 thermometer docks directly into theCSM, no external cradle or USB cord is required– Note: PRO 6000 can not be added to a SureTemp Plusequipped model, customers must choose one type Connex VSM and IWS– Currently only compatible with the PRO 4000 dock– Project to have a PRO 6000 external dock in late Q4 2016 Spot LXi and Diagnostic Desk Set – Not Available– No plan to migrate LXi or DDS to PRO 6000– Will only offer PRO 4000 until monitor is discontinued

Part Numbers & Pricing – US&CPart NumberProduct DescriptionDealer NetDealer MarginList Price06000-200NBraun PRO 6000 with Small Cradle (holds1-PC box) 175.0030% 250.0006000-300NBraun PRO 6000 with Large Cradle (holds2-PC boxes), wall mountable 178.5030% 255.0006000-100Charge Station (includes recharging batterypack) 104.3030% 149.00104894Recharging Battery Pack 20.3030% 29.001062016' Tether 22.4030% 32.001062049' Tether 37.8030% 54.0006000-005*Braun PRO 6000 Probe Covers, 5K case (25sleeves of 200, 10 bx of 20) 281.4033% 420.00 No Kit part numbers available at launch – device and charging station sold separately may introduce kits in 2016 Non “N” part numbers sold OUS&C (06000-200 & 300)

Braun PRO 6000 vs. Consumer ThermoScan 5Feature/FuntionPRO 6000ThremoScan 5IRT 6520ExacTemp TechnologyPre-Heated Tip and SensorPulse Timer and C/F ButtonNot AvailablePerfecTemp TechnologyNot AvailableTested Cycle Count Life100K10KCharging StationNot AvailablePC Box Carrier in CradleHinged box carrierNo box carrierSecurity Optionstime, tether, cradleNot AvailableDevice Power OnInstant from cradleMust push power buttonBattery Door LatchSpring loaded latchSnap in style doorTextured GP22 ResinSmooth ABS (brittle)Recharging OptionBody Housing PlasticPRO 6000ThermoScan 5 IRT6020Tested CAL Accuracy Down ToPC Sensing Pin20C (68F)35C (95F)OpticalMechanical Spring

Warranty – 3 Years

PRO 6000 Service &Calibration Calibration check is recommended 1 year– Same process as Braun PRO4000– Works with 9600 Calibration Tester– Calibration certificate shipped with every device Evaluation Units Available in US– E-06000-200N, E-06000-300N– Same process as Braun PRO4000 Available under Partners In Care Ability to upgrade software through Service Tool– Requires a charging station– Device must have rechargeable NiMh battery installed

PRO 6000 Service &Calibration Pro4000 will be no longer for sale in US&C effective 10/31/15Units will be available for 5 years for service & warranty purposesUnits will be available to support LAVs until upgraded to PRO6000Charging stations will remain available as stand lone productPro4000 probe covers remain available for sale to support existingcustomer base– Other regions to follow obsolescence as PRO6000 launches–––– Additional hands-on technical service training will becompleted by Geoff Stone

Selling & Support Materials Product Brochure– SM4117 Product Spec Sheet– SM4122 Dedicated WA Site Product Webpage– Launching 9/7/15 Quick Reference Card– Included with product on DFU CD 18 Language Cleaning Sticker SheetIncluded w/device Updated Cleaning Poster Brainshark (sales and distributorversions) In-service video– On WA youtube site/adding to WA website

Approved Cleaning Solution Table in DFUContactsNoNoNoYesUse a damp cloth or cleaning wipe with cleaning solution from theApproved Cleaning Solutions Table. To clean the body, ensure that thewipe is moist, not saturated. Wipe with display facing up.Wipe clean and dry 5 min.

Braun PRO 4000 and 6000 Probe Covers New Braun PRO 6000 compatibleprobe covers launching with device– New product numbers and GTIN createdfor PRO 6000 covers New design, prevents “knock-off”PRO 4000 like covers fromattaching/activating device Distinctive packaging to identifycompatible device (model name &picture, down to 20 count box) Re-introduced a “flat flange” PRO4000 dedicated cover in Q1 2015– uses current product numbers & GTIN) The Pro 6000 probe covers will fitboth the Pro 6000 and the Pro 4000– Pro 4000 probe covers will not fit the Pro6000!PRO 4000 PCPRO 6000 PCFlat Flange.051” Raised Flange

HANDS ON DEVICE OPERATION

Setting Up the Thermometer Install the AA batteries (1,000 measurements from new set) If needed, change the C/F default setting with switch in thebattery compartment using a pen or pointed object

Setting Up the Thermometer Install the new probe cover box into the cradle Attach the optional tether (1.8m/6ft or 2.7m/9ft) using includedtool

TIME TO TAKE A TEMPERATURE!

Taking a Temperature1. Remove thermometer from cradle by gripping atthe base and pivoting up – turns on automatically2. Attach new probe cover by pushing probe tipstraight into box, then pulling thermometer out3. Wait for ready indication – ring around measurebutton turns green, thermometer will beep once,and 3 dashed lines on display indicate ready

Taking a Temperature4. Place probe snugly in ear canal and direct/aimtoward opposite temple – keep thermometerprobe steady in the ear canal during measurement5. Press and release measure button - unit willbeep once, running dashes will appear on thedisplay then the green ExacTemp light will flash6. Temperature measurement complete with a longbeep and steady green ExacTemp lightilluminates, reading will show on display

Taking a Temperature7. Remove used probe cover by pressing the PCejection button and discard into receptacle8. To take another measurement, place a new, cleanprobe cover on the thermometer. If no action istaken the thermometer will enter SLEEP after 10seconds or upon returning to the cradle or hostdevice.

Using Control Buttons Press the MEMORY button to display last completetemperature. Memory can also be accessed fromthe sleep mode and will display for 5 seconds Switch to alternative temperature scale by pushingthe C/F button while a reading is being displayed –press C/F button again to revert back (also revertsback when unit goes to sleep) Press and hold timer button for one second toactivate timer – display will show timer counting upin seconds and four 15 second quadrants

Setting Up The Charging Station1. Insert rechargeable battery pack into batterycompartment with battery label facing outward.2. Connect the USB cable to the back of the chargingstation (1a) and feed the cable through theretaining clip.3. Select the appropriate interchangeable plug forcountry and region and connect to wall adapter.Plug in USB cable and then into outlet. A greenlight illuminates indicating ready to use.

Charging The Thermometer1. Place the thermometer into the thermometercradle. Place the thermometer in cradle into thecharging station.2. The thermometer will produce an audible beepand the charging indicator on the charging stationwill illuminate amber. The battery charge statuswill be displayed on the thermometer LCD.3. It will change to green when the thermometer isfully charged (approximately 3-4 hours if thebattery is empty). Thermometer display screenalso shows charge level with battery icon.

CLEANING THE DEVICE ANDACCESSORIES

Cleaning the Probe Tip Gently wipe surface of probe lens window with cottonswab or cloth slightly moistened with isopropyl or ethylalcohol only. Use gentle pressure. With probe facing down, wipe the probe with a dampcloth or cleaning wipe moistened with isopropyl or ethylalcohol. Gently wipe with dry, clean cotton swab or clothimmediately. Allow at least 5 minutes drying time before takingtemperature. Make sure probe lens window is clean anddry prior to use.

Cleaning the Device ContactsBody, Cradle, and Charging StationsCAUTION Do not use bleach solutions of anykind when cleaning metal electrical contacts.They will damage the device.1. Slightly dampen a cotton swab with 70%isopropyl alcohol.2. Remove the thermometer from the dock andclean the metal electrical contacts on thethermometer.3. Place the thermometer aside for 1 minute,allowing the contacts to air dry.

Cleaning the Body and Accessories For additional protection, place a new probe coveron the thermometer probe to protect this area whencleaning the body of the thermometer. Use a damp cloth or cleaning wipe with cleaningsolution from the Approved Cleaning SolutionsTable. To clean the body, ensure that the wipe ismoist, not saturated. Wipe with display facing up. Clean accessories using same method. Dry 5 min.

PRO6000 Global Part Numbers

PRO6000 Global Part Numbers

Braun PRO 6000 Offering New Product that addresses some of the top customer complaints of PRO4000 –Improved accuracy (low reading) –Probe cover detection –Ability to wipe device with new, harsher cleaning solutions Protects 35M probe cover business –Braun PRO4000 probe cover loses patent protection next year

Related Documents:

Feb 22, 2016 · 183 welch allyn braun pro 4000 thermoscan thermometer 184 braun thermoscan thermometer centurion service group auction catalog february 24, 2016 lot # description lot # description page 4 185 welch allyn braun type 6021 thermoscan thermometer 186 welch allyn braun type 6021 .

IRT 2000 KURTZ DESIGN 28.01.05 ThermoScan ThermoScan starts t a r t English 3, 16 Polski 8, 16 Internet: www.braun.com Manufactured by: Braun GmbH Frankfurter Str. 145 61476 Kronberg / Germany 6-026-233/00/VII-06/M GB/PL Printed in Germany IRT 3020 CO Type 6026 IRT 2000 KURTZ DESIGN 11.01.06 ThermoScan ThermoScan starts t a r t

Braun ThermoScan PRO 6000 Thermometer Inservice . Table of Contents . 1. Overview . 2. Cleaning the Probe Tip . 3. Cleaning the Body and Accessories . 4. Approved Cleaning Solutions . 5. Probe Covers . 6. Taking a Temperature . Always use PRO 6000 disposable probe covers .

Welch Allyn recommends that you contact your Biomedical . Set up the Braun ThermoScan PRO 4000 thermometer If your system is configured for the Braun ThermoScan thermometer, follow these setup instructions. 1. Remove the thermometer from the package and discard the protective casing.

and Braun ThermoScan PRO 4000 Ear Thermometer 45NE0-E1 Spot Vital Signs LXi with SureBP, Nellcor SpO 2, and Braun ThermoScan PRO 4000 Ear Thermometer SureBP technology measures blood pressure in about 15 seconds as the cuff is infl ating—resulting in time savings for you and improved comfort for your patients; pulse rate and MAP included

and Braun ThermoScan PRO 4000 Ear Thermometer 45NE0-E1 Spot Vital Signs LXi with SureBP, Nellcor SpO 2, and Braun ThermoScan PRO 4000 Ear Thermometer SureBP technology measures blood pressure in about 15 seconds as the cuff is infl ating—resulting in time savings for you and improved comfort for your patients; pulse rate and MAP included

Welch Allyn Braun ThermoScan PRO 4000 Inservice MC12687 1 . Table of Contents 1. Overview 2. Cleaning 3. Cleaning the Electrical Contacts 4. Probe Covers 5. Tympanic Measurements . Always use PRO 4000 disposable probe covers. The new PRO 4000 probe covers can be used with all models of Braun ear thermometers.

Center for Japanese Language, Waseda University Japanese Language Program Admission Guide *This program is not a preparatory course for students intending to enroll in Undergraduate or Graduate programs in Japanese universities. April admission/September admission Center for Japanese Language, Waseda University Center for Japanese Language, Waseda University Address: 1-7-14, Nishi-waseda .