For details about certified productsconforming to international standards,visit us at www.smcworld.com.5 Port Pilot Operated Solenoid ValveMetal Seal, Body PortedSeries VFS2000ModelFlow characteristics1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Model3 position2 positionType ofactuationPortsizeRcPlug-inNon 0.82(1)(2)(3)Max.operating Response Weighttimecycle(kg)(ms)(cpm)VFS2120- E-02-FVFS2220- E-02VFS2120- G-02JIS Symbol2 positionSingle3 positionClosed centerValve specificationsElectricity specificationsVFS2320- T-02Electrical entry120013 or less 0.35VFR60040 or less 0.42VP460040 or less 0.42VZS60040 or less 0.42VFSExhaust centerVQ7Air/Inert gas1.0 MPa0.1 MPa1.5 MPa–10 to 60 C (1)Non-lube (2)Non-locking push type (Flush)150/50 m/s2 (3)Dustproof (Degrees of protection 0) (4)100, 200 VAC, 50/60 Hz; 24 VDC–15 to 10% of rated voltageClass B or equivalent (130 C) (5)5.6 VA (50 Hz), 5.0 VA (60 Hz)3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz1.8 W (2.04 W: With light/surge voltage suppressor)Grommet, Grommet terminal,Conduit terminal, DIN terminalOption SpecificationsCoil rated voltageDoubleVS4Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axialdirection and at the right angles to the main valve and armature in bothenergized and de-energized states every once for each condition. (Valuesat the initial period)Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz.Test was performed at both energized and de-energized states in theaxial direction and at the right angles to the main valve and armature.(Values at the initial period)Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.Pilot typePilot valve manual overrideOptionFoot bracket (With screw)External pilot (1)Non-locking push type (Extended), Locking type (Tool required)110 to 120, 220, 240 VAC (50/60 Hz)12, 100 VDCWith light/surge voltage suppressor (2)Part no.: VFN200-17A, VFS2120 (single) onlyNote 1) Operating pressure: 0 to 1.0 MPa. Pilot pressure: 0.1 to 1.0 MPa.Note 2) No light grommet but surge voltage suppressor (direct connecting lead wire) is installed.ManifoldPressure centerBody typeVFS2 20VFS2 30VF22 or less 0.26Standard SpecificationsFluidMaximum operating pressureMinimum operating pressureProof pressureAmbient and fluid temperatureLubricationPilot valve manual overrideShock/Vibration resistanceEnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeInrushApparent power(Power consumption) AC HoldingPower consumptionVZ1200Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency.Note 2) According to JIS B 8375-1981. (The value at supply pressure 0.5 MPa.)Note 3) In the case of grommet type Note 4) Factors of “Note 1)” and “Note 2)” are achieved in controlled clean air.Compact yet provides ahigh flow capacity1/4: C: 3.4 dm3/(s·bar)Low power consumption:1.8 W DCVKApplicable manifold base (Pilot EXH)Bar manifold (Individual EXH)Bar manifold (Common EXH base side)Note) VFS2 30: Manifold only. Cannot be used as a single unit.3-8-17EVSVFN

SeriesVFS2000How to OrderVFS2 1 20011 GSymbolOption2 position singleF: With foot bracketThread type1Port size01022 position double2Rc 1 8Rc 1 4NilN T F RcNPTNPTFG Option3 position closed center Mountable onlyfor VFS2120.Manual overrideNil: Non-locking push type A : Non-locking push type(Flush)(Extended)3B : Locking type(Tool required)3 position exhaust center43 position pressure center Option5Light/Surge voltage suppressorNoneWith light/surge voltage suppressorWith surge voltage suppressorNilZS Reverse pressure:Can be used byexternalpilotspecifications. Indicator light is not available for grommet type. With surge voltage suppressor isavailable for grommet type only.Body (Pilot exhaust)20: Individual EXHElectrical entryG: GrommetE: Grommet terminalT: Conduit terminalD, Y: DIN terminal30: Common EXH Coil rated voltage123 4 Manifold onlyPilot type56 7 9 Nil Internal pilotR External pilot Option: Individualexternal pilot (External pilot port:Body side)100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)24 VDC12 VDC240 VAC (50/60 Hz)Other OptionHow to Order Pilot Valve AssemblySF41 DZ12Applicable modelCoil rated voltage123 4 56 7 9 Option100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 to 120 VAC (50/60 Hz)220 VAC, 50/60 Hz24 VDC12 VDC240 VAC, 50/60 HzOtherGGSDDZDODOZY YZ YO YOZ GrommetGrommet with surge voltage suppressorDIN terminalDIN terminal with light/surge voltage suppressorDIN terminal DIN terminal with light/surge voltage suppressor TTZEEZConduit terminalConduit terminal with light/surge voltage suppressorGrommet terminalGrommet terminal with light/surge voltage suppressorDIN terminalDIN terminal with light/surge voltage suppressorDIN terminal DIN terminal with light/surge voltage suppressor Y: Conforming to DIN43650B standard DIN connector is not attached.3-8-1812For VFS2 20Individual pilotexhaust13For VFS2 30Common pilotexhaustElectrical entry, Light/Surge voltage suppressorManual overrideNilNon-locking push type (Flush)A Non-locking push type (Extended)Locking type (Tool required)B Option

5 Port Pilot Operated Solenoid ValveMetal Seal, Body PortedSeriesVFS2000Cylinder Speed ChartUse as a guide for selection.Please confirm the actual conditions with SMCSizing Program.Body PortedBore sizeAveragspeed(mm/s)SeriesSeries CJ2Pressure 0.5 MPaLoad factor 50%Stroke 60 mmø6VFS2120-02Series MB/CA1 Note)Pressure 0.5 MPaLoad factor 50%Stroke 500 mmSeries CM2Pressure 0.5 MPaLoad factor 50%Stroke 300 4003002001000ø80ø100Perpendicular,upward actuationHorizontalactuationVKVZVFConditionsBody portedTube bore x LengthVFS2120-02 Speed controllerSilencerSeries CJ2T0604 x 1 mAS3001F-06Series CM2 Series MB/CA1T1075 x 1 mAS4001F-10AN110-01Note) It is when the cylinder is extending that is meter-outcontrolled by speed controller which is directlyconnected with cylinder, and its needle valve with beingfully open. The average velocity of the cylinder is what the strokeis divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x100%Note) The Series CA1 has been changed to the SeriesCA2.Construction2 position singleVFRVP4VZSVFSVS42 position doubleVQ7EVSVFNClosed center3 position closed center/exhaust center/pressure centerExhaust centerPressure centerComponent PartsNo.qwerDescriptionBodySpool/SleeveEnd platePistonMaterialAluminum die-castedStainless steelResinResinNotePlatinum silver———Replacement PartsNo.tyuDescriptionReturn springPilot valve assemblyDetent assemblyMaterialStainless steel——Part FS2000-17-2Refer to “How to Order Pilot Valve Assembly” on page 3-8-18.—VFN2000-8A—3-8-19

SeriesVFS20002 Position Single Grommet, Grommet terminal, Conduit terminal, DIN terminalFoot bracket (F)Part no.: VFN200-17AGrommet: VFS2120- GManual override(Non-locking)()M5: External pilot port Only for external pilot model.2-ø4.5mounting holeSolenoid valve 300(Lead wire length)2-ø3.5 mounting hole2-ø3.5 mounting hole3-Rc 1/8, 1/42-Rc 1/8DIN terminal: VFS2120- D/DZ/Y/YZGrommet terminal: VFS2120- E/EZWith light/surge voltage suppressor (EZ)Lead wire O.D.Max. ø3.5Applicable heavy-duty code O.D. ø6 to ø8 (Y: ø4.7 to ø7)LightWith light/surge voltage suppressor (DZ)Light2-ø3.5 mounting holeConduit terminal: VFS2120- T/TZApplicable heavy-duty code O.D. ø6 to ø8With light/surge voltage suppressor (TZ)2-ø3.5 mounting hole( ): Y, YZLight2-ø3.5 mounting hole3-8-20

5 Port Pilot Operated Solenoid ValveMetal Seal, Body PortedSeriesVFS20002 Position Double, 3 Position Grommet, Grommet terminal, Conduit terminal, DIN terminalGrommet: VFS2220- G, VFS2320- G, VFS2420- G, VFS2520- G182 (3 position: 192.5)VK(M5: External pilot port Only for external pilot model.)VZ 300(Lead wire length)Manual override(Non-locking)2-ø3.5 mounting holeVFVFRVP42-ø3.5 mounting holeVZS3-Rc 1/8, 1/42-Rc 1/8VFSVS4VQ7Grommet terminal:VFS2220- E/EZ VFS2320- E/EZVFS2420- E/EZ VFS2520- E/EZLead wire O.D. Max. ø3.5With light/surge voltage suppressor (EZ)DIN terminal: VFS2220- D/DZ/Y/YZVFS2320- D/DZ/Y/YZVFS2420- D/DZ/Y/YZVFS2520- D/DZ/Y/YZEVSVFN182 (3 position: 193)Applicable heavy-duty code O.D. ø6 to ø8 (Y: ø4.7 to ø7)LightWith light/surge voltage suppressor (DZ)219 (3 position: 229)Light2-ø3.5 mounting holeConduit terminal:VFS2220- T/TZ VFS2320- T/TZVFS2420- T/TZ VFS2520- T/TZ2-ø3.5 mounting hole( ): Y, YZApplicable heavy-duty code O.D. ø6 to ø8With light/surge voltage suppressor (TZ)219 (3 position: 229)Light2-ø3.5 mounting hole3-8-21

VFS2000Manifold SpecificationsSingle Base TypeSeriesSpecificationsKeeps environmental airclean from pilot exhaustUse of the VV5FS2-30 manifold can exhaustside, and can prevent environmentalaggravation due to noise and oil mist.Manifold base typeStationsBar manifold, Body portedMax. 15 stationsPort : 3 85(R1), 3(R2)CommonPorting specifications: RcValveBase2(B), 4(A)3(R2), 5(R1)Top: 1 8, 1 4Side: 3 8OptionBlanking plateVVFS2000-10A-1With gasket, screwHow to Order Manifold BaseVV5FS22005 103VV5FS2-20Thread typeSeries VFS2000ManifoldNilN T F RcNPTNPTFG OptionP, EA, EB port size03–Rc 3 8SymbolStations02 Part no. for mounting bolt and gasketBG-VFS2030 VV5FS2-302 stations1515 stationsPassagePorting specifications3(R2), 5(R1)2(B), 4(A)1(P)Common CommonTop1 Rc 3Rc 3 8Rc 1 8, 1 48Base modelModelPilot exhaustPilot individual EXHApplicable valve modelVFS2 20- - 010220Pilot common EXHVFS2 30- -010230How to Order Manifold AssemblyInstruct by specifying the valves and blanking plate to bemounted on the manifold along with the manifold base model no. Examble (Manifold base)(2 position single)(2 position double)(Blanking D-02VVFS2000-10A-11321 VFS2 20- -0102mountable

5 Port Pilot Operated Solenoid ValveMetal Seal, Body PortedSeriesVFS2000Type 20 Manifold Pilot individual exhaust: VV5FS2-20- Station 1-03Grommet: G2n-Rc 1/8, 1/4M3 x 44VK6-Rc 3/8VZU sideVFD sideVFR4-ø5 mounting holeVP4Blanking plateP 25VZS 300(Lead wire length)VFSPilot EXHVS4GasketVQ7EVSStationsVFNFormula for manifold weight M 0.108n 0.068 (kg) n: StationGrommet terminal: E/EZDIN terminal: D/DZConduit terminal: T/TZApplicable heavy-duty codeO.D. ø6 to ø8Applicable heavy-duty codeO.D. ø6 to ø8 (Y: ø4.7 to ø7)Lead wire O.D.Max. ø3.5Double (219)Single (143.5)3 position (229)Double (219)Single (143)3 position (229)Double (182)Single (125)3 position (193)6-Rc 3/86-Rc 3/86-Rc 3/8(With light/surge voltage suppressor: 91.5)(With light/surge voltage suppressor: 108.5 (110.5))(With light/surge voltage suppressor: 96)(With light/surge voltage suppressor: 101)(With light/surge voltage suppressor: 117.5 (119.5))(With light/surge voltage suppressor: 106)( ): Y, YZn: 871831938208218923324310258268FormulaL1 25 x n 8L2 25 x n 183-8-23

SeriesVFS2000Type 30 Manifold Pilot common exhaust: VV5FS2-30- Station 1-03Grommet: G2n-Rc 1/8, 1/4M3 x 44U sideD side4-ø5 mounting hole6-Rc 3/84-M5 (Pilot EXH port)Blanking plateP 25 300(Lead wire length)GasketStationsFormula for manifold weight M 0.12n 0.21 (kg) n: StationGrommet terminal: E/EZConduit terminal: T/TZDIN terminal: D/DZ/Y/YZApplicable heavy-duty codeO.D. ø6 to ø8(Y: ø4.7 to ø7)Applicable heavy-duty codeO.D. ø6 to ø86-Rc 3/8Double (219)Single (143.5)3 position (229)Double (219)Single (143)3 position (229)Double (182)Single (125)3 position (193)Lead wire O.D.Max. ø3.56-Rc 3/86-Rc 3/8(With light/surge voltage suppressor: 98)(With light/surge voltage suppressor: 115 (117))(With light/surge voltage suppressor: 102.5)(With light/surge voltage suppressor: 107.5)(With light/surge voltage suppressor: 124 (126))(With light/surge voltage suppressor: 112.5)( ): Y, YZn: 7616219271872178212242923726710262292FormulaL1 25 x n 12L2 25 x n 42

For details about certified productsconforming to international standards,visit us at www.smcworld.com.5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-inSeries VFS2000ModelModel3 position2 positionType ofactuationPortsizeRcPlug-inNon 500centerDoublecheckVFS2600Flow characteristics1 4/2 (P A/B)4/2 5/3 (A/B (1)(2)Max.(3)operating Response Weighttimecycle(kg)(ms)(cpm)VZVF120015 or less0.34120013 or less0.42VFR60020 or less0.43VP460020 or less0.43VZS60020 or less0.43VFS60025 or less0.6VS4Note 1) Based on JIS B 8375 (Once per 30 days) for the minimum operating frequency. Note 2) Based on JIS B 8375-1981 (The value at supply press. 0.5 MPa).Note 3) Values for VFS2 00- FZ-01. Note 4) Factors of “Note 1)” and “Note 2)” are ones achieved in controlled clean air.VQ7Compact yet provides a large flowcapacity1/4: C: 2.8 dm3/(s·bar)Low power consumption: 1.8 W DCEasy maintenance2 types of sub-plates:Plug-in and non plug-inValve specificationsStandard SpecificationsFluidMaximum operating pressure2 positionMin. operating pressure3 positionProof pressureAmbient and fluid temperatureLubricationPilot valve manual overrideShock/Vibration resistancePlug-in typeNon plug-in typeJIS Symbol2 position3 positionSingleClosed centerElectricity specificationsEnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeInrushApparent power(Power consumption) AC HoldingPower consumption DCElectrical entryNote 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction andat the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period)Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed atboth energized and de-energized states in the axial direction and at the right angles to the mainvalve and armature. (Values at the initial period)Note 4) Based on JIS C 0920.Note 5) Based on JIS C 4003.Option SpecificationsPilot typeManual overrideDoubleExhaust centerCoil rated voltagePorting specificationsOptionPressure centerAir/Inert gas1.0 MPa0.1 MPa0.15 MPa1.5 MPa–10 to 60 C (1)Non-lube (2)Non-locking push type (Flush)150/50 m/s2 (3)Type G, E: Dustproof (Class 0),Type F, T, D: Splashproof (Class 4) (4)100, 200 VAC, 50/60 Hz; 24 VDC–15 to 10% of rated voltageClass B or equivalent (130 C) (5)5.6 VA/50 Hz, 5.0 VA /60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz1.8 W (2.04 W: With light/surge voltage suppressor)Plug-in typeConduit terminalNon plug-in typeGrommet terminal, DIN terminalExternal pilot Note)Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever)110 to 120, 220, 240 VAC, 50/60 Hz12, 100 VDCBottom portedWith light/surge voltage suppressorNote) Operating pressure: 0 to 1.0 MPaPilot pressure 2 position: 0.1 to 1.0 MPa 3 position: 0.15 to 1.0 MPaCompact, lightweight type sub-plateDouble checkCompared with the standard type, this is the subplate having the reduced external dimensions andlighter weight. But, use caution that Cv factor orpiping port position is different from the standards.For details, refer to page 5-8-52.Sub-plateL(mm)Standard typeCompact type31.025.5Weight Sonic conductance (kg) C [dm3/(s·bar)]0.20.132.22.8 2 position single Rc 1/43-8-33EVSVFN

SeriesVFS2000How to OrderPorting specificationsNilB Port sizeNilSide portedBottom ported OptionOptionNilZWith attachment pluglead wire0102Rc 1 4Note)NoneWith light/surge voltage suppressorP01Note)Body typeP02Electrical entryO: Plug-in typesub-plateF: Plug-in typeWithout sub-plateRc 1 8Plug-in type conduitterminal(With terminal block)Standard typePlug-in type grommet(With attachmentplug lead wire)Compact typeRc 1 8Rc 1 4Note) Please note Cvfactor and pipingport location ofcompactsubplate is differentfrom standard.Refer to page3-8-52 for details.Thread typeRcNPTNPTFGNilN T F With terminal block OptionPlug-inVFS2 2 005 F01Non plug-inVFS2 2 101 E02Pilot valve manual overrideNil: Non-locking push type B : Locking type(Flush)(Tool required)Port size0102SymbolBody type2 position singleA : Non-locking push type C : Locking type(Extended)(Lever)1: Non plug-in typesub-plate12 position double2 OptionOptionNilZS Pilot type3 position closed centerNilR 3Internal pilotExternal pilotCoil rated voltage4123 4 56 7 9 100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz24 VDC12 VDC240 VAC, 50/60 HzOther Option3 position pressure center53 position double check618RcWithout sub-plateNon plug-in type,Standardtype14Note)RcS0118Note)RcS0214Non plug-in type,CompacttypeNote) Please note Cvfactor and pipingport location ofcompact sub-plateare different fromstandard. Refer topage 3-8-52 fordetails. Indicator light is not available for grommettype. With surge voltage suppresor is avilablefor grommet type only. Option: External pilot ispossible only to the onewith sub-plate.3 position exhaust centerNoneWith light/surge voltage suppressorWith surge voltage suppressorNilRcElectrical entryG: GrommetE: Grommet terminalT: Conduit terminal D, Y: DIN terminalHow to Order Pilot Valve AssemblySF41 DZ20Electrical entry, Light/Surge voltage suppressorCoil rated voltage123 4 100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 to 120 VAC (50/60 Hz)220 VAC, 50/60 Hz524 VDC6 12 VDC7 240 VAC, 50/60 Hz9 Other Option3-8-34FPlug-inPlug-inGGrommetGSGrommet with surge voltage suppressorDDIN terminalNonDZ DIN terminal with light/surge voltage suppressorplug-in DODIN terminal DOZ DIN terminal with light/surge voltage suppressorYDIN terminalYZ DIN terminal with light/surge voltage suppressorDIN terminal YOYOZ DIN terminal with light/surge voltage suppressor NonTConduit terminalTZ Conduit terminal with light/surge voltage suppressor plug-inEGrommet terminalEZ Grommet terminal with light/surge voltage suppressor DIN connector is not attached. Refer to page 3-8-4 for voltage conversion. Y: Conforming to DIN43650B standardManualoverrideNilNon-lockingpush type(Flush)A Non-lockingpush type(Extended)B Locking type(Tool required)C Locking type(Lever) Option

5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-inSeriesVFS2000Cylinder Speed ChartUse as a guide for selection.Please confirm the actual conditions with SMCSizing Program.Bore sizeSystemAveragespeed(mm/s)Series CMPressure 0.5 MPaLoad factor 50%Stroke 300 mmø20ABø25Series MBPressure 0.5 MPaLoad factor 50%Stroke 500 5004003002001000ø160Perpendicular,upward 02001000SpeedcontrollerVKVFVP4VZS It is when the cylinder is extending that is meter-out controlled by speedcontroller which is directly connected with cylinder, and its needle valvewith being fully open. The average velocity of the cylinder is what the stroke is divided by thetotal stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 100%System ComponentsSystem Solenoid valveSeries CS1Pressure 0.5 MPaLoad factor 50%Cylinder stroke 1000 mmSilencerTube bore x LengthASeriesVFS2000Rc 1 8AS3000-02AN110-01(S 12 mm2) (S 35 mm2)T0604 x 1 mBSeriesVFS2000Rc 1 4AN110-01AS4000-02(S 21 mm2) (S 35 mm2)T1075 x 1 mVS4VQ7EVSVFNDouble Check Spacer/SpecificationsCan hold an intermediate cylinderposition for an extended timeSpecificationsIf the double check spacer with a built-indouble check valve is combined, it will enable the cylinder to stop in the intermediatestroke and maintain its position for a longtime without being affected by the leakagebetween the spools.Double checkspacer part no. VVFS2000-22A-1Check Valve OperatingPlug-in typeNon plug-in typeVVFS2000-22A-2Cylinder pressureGEVFS2400- FCheck valveVFS2410- TDSolenoid oneside energizedPR1R2PR1R2AR1BR2210or less210or less0 Supply pressure: 0.5 MPaCaution In the case of 3 position double checkvalve (VFS26 0), check the leakage frompiping and fittings in between valve andcylinder by means of synthetic detergentsolutions, and ensure that there is no suchleakage found there. Also check theleakage from cylinder seal and piston seal.If there is any leakage, sometimes thecylinder, when valve is de-energized, canmove without stopping at intermediateposition. Be aware that if the exhaust side isrestricted excessively, the intermediatestopping accuracy will decrease and willlead to improper intermediate stops.SUP side pressure (P1)PistonSUP side pressure P1 (MPa)Applicablevalve modelLeakage (cm2/min) Solenoidboth sidesde-energizedDouble check spacerVFSOperating rangeCylinder pressure P2 (MPa) The combination of VFS2101 0, VFS22 01 0 anda double check spacer can be used asprevention of falling at the stroke end butcannot hold the intermediate position of thecylinder.3-8-35

SeriesVFS2000Construction2 position single2 position double3 position closed center/exhaust center/pressure centerClosed centerExhaust centerPressure centerComponent veAdapter plateEnd platePistonJunction coverCoverSub-plate Assembly (Standard) Part No.MaterialAluminum die-castedAluminum die-castedStainless steelAluminum die-castedResinResinResinResinNotePlatinum silverPlatinum silver—Platinum silverBlack———Plug-inVFS2000-LP- 0102Non plug-inVFS2000-LS- 0201 Mounting bolt and gasket are not included.Part no. for mounting bolt and gasketBG-VFS2000Replacement PartsNo.DescriptionMaterialo!0!1!2!3Return springGasketHexagon socket head screwDetent assemblyPilot valve assemblyStainless steelNBRSteel——3-8-36Part no.VFS21 VFS22 VFS23 /24 /25 Refer to “How to Order Pilot Valve Assembly” on page 3-8-34.

5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-inSeriesVFS2000Plug-in 2 Position single/double, 3 position closed center/exhaust center/pressure center/double check2 position single: VFS2100- F-01023-Rc1 8, 1 41(P), 4(A), 2(B) bottom ported2-ø5 mounting hole2-Rc 1 83(R2), 5(R1) bottom portedManual override(Non-locking)VKVZBottom portedVFWith light/surge voltage suppressorVFRVP4VZSVFSG12Electrical entry3-Rc2-Rc1 8, 1 418VS4(External pilot port)(M5 x 0.8)VQ7Pilot EXH portM5 x 0.8( ): Rc 1 82 position double: VFS2200- F-01023 position closed center: VFS2300- F-01023 position exhaust center: VFS2400- F-01023 position pressure center: VFS2500- F-0102150.5 (3 position: 158)2-ø5 mounting holeEVSVFN3 position double check: VFS2600- F-0102Manual override(Non-locking)2-ø5 mounting holeManual override(Non-locking)163.5 (3 position: 171)With light/surge voltage suppressorWith light/surge voltage suppressor( ): Rc 1 8( ): Rc 1 83-8-37

SeriesVFS2000Non Plug-in 2 position singleGrommet: VFS2110- G-01023-Rc 1 8 , 1 41(P), 4(A), 2(B) bottom ported2-ø5 mounting holeManual override(Non-locking)2-Rc 1 83(R2), 5(R1) bottom ported 300(Lead wire length)Bottom portedA, B3-Rc2-Rc1 8, 1 418Pilot EXH port M5 x 0.8(External pilot port M5 x 0.8)( ): Rc 1 8Grommet terminal: VFS2110- E-010201DIN terminal: VFS2110- DY -02With light/surge voltage suppressorLead wire O.D. Max. ø3.5Applicable heavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)LightWith light/surge voltage suppressorLightConduit terminal: VFS2110- T-0102Applicable heavy-duty cordO.D. ø6 to ø8With light/surgevoltage suppressorLight3-8-38( ): Y, YZ

5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-inSeriesVFS2000Non Plug-in 2 Position double, 3 position closed center/exhaust center/pressure centerGrommet: Double VFS2210- G-01020101Closed center VFS2310- G-0102, Exhaust center VFS2410- G-02, Pressure center VFS2510- G-02150.5 (3 position: 158)3-Rc 1 8 , 1 41(P), 4(A), 2(B) bottom ported2-Ø5mounting hole72.5Manual override(Non-locking)2-Rc 1 83(R2), 5(R1) bottom portedVK 300(Lead wire length)VZBottom portedVFVFRVP4A, B3-Rc2-Rc1 8, 1 4VZSVFSPilot EXH port M5 x 0.8(External pilot port M5 x 0.8)VS418( ): Rc 1 8Grommet terminal: Double VFS2210- E-0102Closed center VFS2310- E-0102Exhaust center VFS2410- E-0102Pressure center VFS2510- E-0102With light/surge voltage suppressorVQ701DIN terminal: Double VFS2210- DY -0201Closed center VFS2310- DY -02D 01Exhaust center VFS2410- Y -0201Pressure center VFS2510- DY -02EVSVFN151 (3 position: 159)Lead wire O.D. Max. ø3.5LightApplicableheavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)187.5 (3 position: 195)With light/surge voltage suppressor(DZ)LightConduit terminal: Double VFS2210- T-0102Closed center VFS2310- T-0102Exhaust center VFS2410- T-0102Pressure center VFS2510- T-0102Applicableheavy-dutycordO.D. ø6 to ø8187.5 (3 position: 195)With light/surge voltage suppressor( ): Y, YZLight3-8-39

SeriesVFS2000Non Plug-in 3 position double checkGrommet: VFS2610- G-01023-Rc 1/8, 1/41(P), 2(B), 4(A) bottom ported2-Rc 1/83(R2), 5(R1) bottom ported2-ø5 mounting hole 300(Lead wire length)Manual override(Non-locking)2-Rc183-Rc1 8, 1 4(External pilot port)(M5 x 0.8)Pilot EXH portM5 x 0.8( ): Rc 1 801DIN terminal: VFS2610- DY -02Grommet terminal: VFS2610- E-0102Lead wire O.D. Max. ø3.5Bottom portedWith light/surge voltage suppressorLightWith light/surge voltage suppressor(DZ)LightApplicableheavy-dutycodeO.D. ø6 to ø8(Y: ø4.7 to ø7)Conduit terminal: VFS2610- T-0102With light/surge voltage suppressorLight( ): Y, YZApplicableheavy-dutycodeO.D. ø6 to ø83-8-40

SeriesVFS2000Manifold SpecificationsPlug-in Type: With Attachment Plug Lead WireThe insert plug is attached to the manifoldblock and lead wire is plugged into the valveside. Please connect with correspondingpower side.VV5FS20106 1Thread type01SymbolSeries VFS2000ManifoldPassageEA, EBPSymbolRcNPTNPTFG OptionSide1Port sizeCommon Common2 BottomSymbol P, EA, EB A, B 3SideRc 1 801Common IndividualRc4 BottomRc 1 402145 SideMMixedIndividual Common6 Bottom For bottom ported,7 SideRc 1/8 is onlyIndividual IndividualBottom Optionavailable.8 Plug-in typeWith attachment plug lead wireStations02 2 stations 15 15 stationsWith attachment plug lead wirePortingspecificationsA, BNilN T F Since lead wires of solenoid valve are connectedwith the terminals on upper surface of terminalblock, corresponding lead wires from power sourcecan be wired at the bottom of terminal block.VV5FS2 01T 108 1Symbol12 3 4 5 6 7 8 Plug-in typeWith terminal blockJunction cover022 stations···1Conduit portStationsSeparate junctioncoverOne-piece junctioncover···Nil15 15 stationsVV5FS2 01C D 1DUPlugassemblyRefer to page 3-8-8.Stations02One-piece junctioncover2 stations···Multi-connector12 3 4 5 6 7 8 D side mountingU side mounting088 stations Max. 8 stationsN T F RcNPTNPTFGPort size OptionSideSymbol P, EA, EBBottomA, BSide01Rc 1 8Common IndividualRcBottom02Rc 1 414SideMMixedIndividual CommonBottom For bottom ported,SideRc 1/8 is onlyIndividual Individualavailable.Bottom Option01SymbolJunction cover1PortingspecificationsA, BThread typeNilCommon CommonSymbol···D sidePassageP EA, EB05 2Plug-in typeSeriesVFS2000 With multi-connectorManifold Connector mounting directionU side02SymbolSeries VFS2000ManifoldOne-piece junction cover Master connection of power and solenoid valves. Quick wiring permits ease of installation.Thread typeNilN T F RcNPTNPTFG OptionPassage PortingspecificationsP EA, EB A, BPort sizeSideCommon CommonSymbol P, EA, EB A, BBottomSide01Rc 1 8Common IndividualRcBottom02Rc 1 414SideMMixedIndividual CommonBottom For bottomported, Rc 1/8 isSideIndividual Individualonly available.Bottom OptionPlug-in Type: With D-sub Connector (Wiring specifications: Refer to page 3-8-8.) Wide range of interchangeability(D-sub connector (25P) conforming to MILstandard) Quick wiring permits easier installation.U sideVV5FS2 01F U 1Symbol12 3 4 5 6 7 8 D side mountingU side mountingStationsJunction cover02One-piece junctioncoverD side2 stations···101Symbol···D-sub connector06 1Plug-in typeSeriesVFS2000 With D-sub connectorManifold Connector mounting directionDUPlug assemblyRefer to page 3-8-8.088 stations Max. 8 stationsPassageP EA, EBPortingspecificationsA, BThread typeNilN T F RcNPTNPTFG OptionSidePort sizeBottomSymbol P, EA, EB A, BSideCommon IndividualRc 1 801BottomRcRc 1 40214SideIndividual CommonMixedMBottom For bottomSideIndividual Individualported, Rc 1/8 isBottom Optiononly available.Common CommonNon Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal Wiring for every valveVZVFPlug-in Type: With Terminal BlockIndividual junction coverVKVV5FS21005 2Thread type01SymbolSeries VFS2000ManifoldSymbolNon plug-in typeStations022 stations······15 15 stations12 3 4 5 6 7 8 PassageEA, EBPPortingspecificationsA, BSideBottomSideCommon IndividualBottomSideIndividual CommonBottomSideIndividual IndividualBottom OptionCommon CommonNilN T F Port sizeRcNPTNPTFG OptionSymbol P, EA, EB A, B01Rc 1 8Rc02Rc 1 414MMixed For bottom ported,Rc 1/8 is onlyavailable.Note) The individual specification of the P port at the composition symbol 3 to 8 or the EA, EB, ports should be taken a

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Grommet terminal: VFS2120- E/EZ DIN terminal: VFS2120- D/DZ/Y/YZ Foot bracket (F) Part no.: VFN200-17A Conduit terminal: VFS2120- T/TZ ( ): Y, YZ 2 Position Single Grommet, Grommet terminal, Conduit terminal, DIN terminal

Related Documents:

Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valve and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the .

LVM09/090 2/3 port direct operated solenoid Cv 0.018 139 LVM10/100 2/3 port direct operated solenoid Cv 0.03 0.04 139 LVM15/150 & -20/200 2/3 port direct operated solenoid valve Cv 0.015 0.065 140 VDW10, -20 & -30 2/2 solenoid Cv 0.03 0.44 141 VDW200 & -300 3/2 solenoid Cv 0.03 0.44 142 VCA solenoid valve Cv 0.33 2.1 143 N

S - 5,20 bar (75 psi) check Solenoid Energization Identity Blank - Standard arrangement for ANSI B93.9 (i.e. energize solenoid A to follow flow P to A). V - Solenoid identification determined by position of solenoid (i.e. solenoid A at port A end/solenoid B at port B end). Note 4 and 8 type spools are always V. Solenoid

SOLENOID CONTROLLED PILOT Up to 31.5 MPa (4570 PSI), 1100L/min (291 U.S.GPM) Pub. EC-0404 PILOT OPERATED DIRECTIONAL VALVES OPERATED DIRECTIONAL VALVES . Pilot Drain Port for Solenoid Controlled Pilot Operated Directional Valve Avoid connecting the valve pilot drain port to a line with

4, 5 port pilot operated valve 4TB 5 port pilot operated valve (pneumatic valve) 4L2-4/LMFO 3, 4, 5 port pilot operated valve (pneumatic valve) 4KA/4KB 5 port pilot operated valve (pneumatic valve) 4F 5 port pilot operated valve (ISO conformed valve) PV5G/PV5/CMF 3 port direct acting valve (small pneumatic valve) 3MA0/3MB0

LAPPED SPOOL & SLEEVE, PILOT OPERATED SOLENOID VALVES PM Series The solenoid operated air valves of this series are types with an internal-pilot-type metal seal . 3/5-PORT PAILOT OPERATED SOLENOID VALVE PM25 series �P.26

DG5V-5, Solenoid Controlled, Pilot Operated Models Comprehensive and simplified symbols shown configured for external pilot supply and internal drain Functional . V - Solenoid "A" at port "A" end of pilot valve body and/or solenoid "B" at port "B" end of pilot valve body, independent of main-stage port locations

Pilot Operated 2 Port Valve type N.C./N.O. Port size 1/4 to 2 32 A to 50 A Orifice size mmø 10 to 50 VXR21/22/23 For Water, Oil Water Hammer Relief, Pilot Operated 2 Port Valve type N.C./N.O. Port size 1/2 to 2 Orifice size mmø 20 to 50 VX21/22/23 For Air, Vacuum, Water, Steam, Oil Direct Operated 2 Port Valve type N.C./N.O. Port size 1/8 to .