D08Series 35Solenoid Pilot Operated Directional ValvesD0831341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

D08Series 35- Solenoid Pilot Operated Directional ValvesGENERAL FEATURESSTANDARD FEATURES High Pressure/ High Flow:158gpm (600lpm)/ 4641psi (320bar) Pilot Operation: Main spool controlled by D03solenoid pilot valve- allows for addition of modularvalves to reduce shifting shock. Oil Immersed, Quiet Solenoid Design: Moving coreimmersed in hydraulic oil provides quiet pilot operation. Wiring: Electrical box with indicator lights andterminal strip connection standard. DIN coilsavailable and provided with DIN connector. Maintenance: Plug-in coils provide easy changing. High Reliability: Valve designed to last 20 millionspool shifts under proper use.TECHNICAL DATANominal Flow Rates: @ 4641 psi@ 1000 psi158gpm (600 lpm)100 gpm (378 lpm)Maximum Operating Pressure:ports P, A, B*port T-Including Surges4641 psi (320 bar)2000 psi (140 bar)Internal Leakage @ 3000 psi6 cu-in/ min (98 ml/ min)Maximum Cycle Rate150 cycles/ minMounting Surface: NFPAISOT3.5.1.MR-D08ISO 4401- 08Weight: Single SolenoidDouble Solenoid29 lbs (13.1 kg)30 lbs (13.5 kg)Operating Conditions:Working Temperature40 - 1600F (5 - 700C)Operating Viscosity80 - 300 SUS (17 65 cSt)Maximum Start-up Viscosity1500 SUS (315 cSt)Filtration25 micron or less, (ISO 18/15)Recommended FluidsPetroleum Based Fluids- ISO VG32-68, Most Vegetable Oils*3000 psi available - specify external drain31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.comD08S

D08Series 35- Solenoid Pilot Operated Directional ValvesPRESSURE DROP CURVESFor continuous flow conditions or high cycling applications, a recommended max. flow rating is: 1/2 x maximum flow rating.Standard 115 VACModel ressurepsi (bar)Max.flowgpm (lpm)4600(320)75(283)1113P AFlow PathP B A TB TD08S-1A-115A-35(Pilot Valve D03S-1A-115A-35)1ASpring Centered: All PortsBlocked/ HydraulicOffset(Closed in Transition)D08S-2B-115A-35(Pilot Valve D03S-2F-115A-35)2BSpring Centered:All Ports t Valve D03S-2F-115A-35)2CSpring Centered:P to T, A & B Blocked4600(320)65(283)3124D08S-2F-115A-35(Pilot Valve D03S-2F-115A-35)2FSpring Centered:P to Blocked, A & B to T4600(320)75(283)2235D08S-2H-115A-ED-35(Pilot Valve D03S-2F-115A-35)2HSpring Centered:All Ports Open4600(320)75(283)4434D08S-3A-115A-35(Pilot Valve D03S-3A-115A-35)3ASpring Centered: All PortsBlocked/ HydraulicDetented(Closed in Transition)4600(320)75(283)1113Maximum flows may be increased by 30% (except spool 2C) if 250 psi pilot pressure is maintained.External draining may be required where high tank line pressures exist (high flow)- the differential pressure between pilotpressure and back pressure at tank port should always be 70 psi minimumPilot/ Drain ConfigurationsSpool Codes A, B, F Supplied Internal Pilot & Internal Drain StandardSpool Codes C and H Supplied Internal Pilot & Internal Drain Standard 70 psi back-pressure check provided in pressure port to provide shifting pressure.External Drain- Specify “ED” Suffix External Pilot- Specify “EP” suffixOnly use Hyvair plugs with short insertion depth.31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.comP T73

D08Series 35- Solenoid Pilot Operated Directional ValvesDIMENSIONSUnits: mm (inches)D08 - DIMENSIONAL DRAWINGPTAdd 1.57”per Modular Valve(SC & SDC options),D03-N1-P,D03-FC1- AB-MO,D03-PR1-P-.5KPre Load Check(Spools C & H Only)INSTALLATION DIMENSIONSExternalPilotSingle Valve Fastening:6 Bolts M12 x 6050.9 ft-lbs (69 Nm)O Rings: (metric)4 O-rings type 29.82 x 2.622 O-rings type 20.29 x 2.62Required SurfaceFinish of Interface31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.comExternalDrain

D08Series 35- Solenoid Pilot Operated Directional ValvesCROSS SECTIONCROSS SECTION DRAWING1) Main Valve with Housing 3.2) Return Spring2) Main Control Spool3.1) Return Spring4) Pilot Valve5.1) Solenoid5.2) Solenoid6) Spring Chamber8) Spring Chamber9) Manual Override9) Manual Override10) Pilot SpoolORDERING INFORMATIONORDERING EXAMPLED08 S-2 B- 115 A - Options - 35D08S SolenoidSD Solenoid withDin CoilSC Solenoid with*Pilot ChokeSDC Solenoid withDin Coil &*Pilot Choke1 Single Solenoid 2 position,spring offset2 Double Solenoid 3 position,spring centered3 Double Solenoid 2 position,no center, detented5 Single Solenoid 2 position,spring centeredA P to A, B to TB All Ports BlockedC P to T, A & B BlockedF P Blocked, A & B to TH All Ports OpenVoltage1224115230CurrentA ACD DC*Pilot choke valve, (D03FC1-AB-MO- meter out flow control), provides softer shifting.Also consider additionally using D03PR1-P-.5K pressure reducing valve if system pressure is above 1,000 psi. (See dimensional data)Options:“EP” suffix for External Pilot (x-port connection) “ED” suffix for External Drain (y-port connection)At least one of these options must be used on C & H spools unless Internal Pre Load Check (standard) is used.31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

Series 35- Solenoid Pilot Operated Directional Valves 31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com CROSS SECTION CROSS SECTION DRAWING 1) Main vVal e with Housing 2) Main Control Spool 3.1) Return Spring 3.2) Return Spring 4) Pilovet Val 5.1) Solenoid 5.2) Solenoid 6) Spring Chamber

Related Documents:

Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valve and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the .

LAPPED SPOOL & SLEEVE, PILOT OPERATED SOLENOID VALVES PM Series The solenoid operated air valves of this series are types with an internal-pilot-type metal seal . 3/5-PORT PAILOT OPERATED SOLENOID VALVE PM25 series �P.26

S - 5,20 bar (75 psi) check Solenoid Energization Identity Blank - Standard arrangement for ANSI B93.9 (i.e. energize solenoid A to follow flow P to A). V - Solenoid identification determined by position of solenoid (i.e. solenoid A at port A end/solenoid B at port B end). Note 4 and 8 type spools are always V. Solenoid

SOLENOID CONTROLLED PILOT Up to 31.5 MPa (4570 PSI), 1100L/min (291 U.S.GPM) Pub. EC-0404 PILOT OPERATED DIRECTIONAL VALVES OPERATED DIRECTIONAL VALVES . Pilot Drain Port for Solenoid Controlled Pilot Operated Directional Valve Avoid connecting the valve pilot drain port to a line with

LVM09/090 2/3 port direct operated solenoid Cv 0.018 139 LVM10/100 2/3 port direct operated solenoid Cv 0.03 0.04 139 LVM15/150 & -20/200 2/3 port direct operated solenoid valve Cv 0.015 0.065 140 VDW10, -20 & -30 2/2 solenoid Cv 0.03 0.44 141 VDW200 & -300 3/2 solenoid Cv 0.03 0.44 142 VCA solenoid valve Cv 0.33 2.1 143 N

DG5V-5, Solenoid Controlled, Pilot Operated Models Comprehensive and simplified symbols shown configured for external pilot supply and internal drain Functional . V - Solenoid "A" at port "A" end of pilot valve body and/or solenoid "B" at port "B" end of pilot valve body, independent of main-stage port locations

DC-41DT 12V DC Solenoid Operated Power Up/Power Down . . . . . 99 DC-50SF 12V DC Manual Operated Power Up/Power Down . . . . . 100 DC-60SF 12V DC Solenoid Operated Power Up/Power Down . . . . 101 DC-62SF 12V DC Solenoid Operated Dual Power Up/Power Down . . 102 DC-70SF 12V DC Solenoid Operated Power Up/Power Down . . . . 103

Pilot Operated Directional Valves Catalog DG3V-10 Hydraulic Pilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid Pilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NFPA D10, ISO-4401-10, CETOP 10. 2 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC004-E March 2007 . integral check valves and port .