cause water-cooled chillers can take advantage of lower condensing temperatures than air-cooled chillers. Air-cooled chillers have a full load kW/ton of approxi-mately 1.25 while water-cooled chillers have a full load kW/ton of between 0.55 and 0.8 kW/ton. The kW draw of the cooling tower fans and con-denser water pump should be

Air cooled inverter water chiller MANUAL EWAD TZ 170-710 Air cooled inverter water chiller D-EOMAC00909-14EN Operation Manual 1 Air cooled inverter water chillers D-EOMAC00909-14EN OPERATION MANUAL EWAD TZ -SS - Screw - R134a - 170 710 kW - SILVER EWAD TZ -SR - Screw - R134a - 170 710 kW - SILVER EWAD TZ -XS - Screw - R134a - 180 682 kW - GOLD

Air Cooled Chiller Air Air 2 Air Air 6 AIR COOLED CHILLERS Air-cooled chillers are refrigeration machines that remove heat from cooling loads using chilled water and reject this heat into the atmosphere using refrigerant. THEY ALL HAVE fans, condenser coils, and compressors. Air-cooled chillers are used to provide cooling for human comfort and electronic equipment as well as industrial process .

Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 80 F chilled water. MAXIMUM SERIES † Air & Water-Cooled † 1/4 to 40 Tons † 20 F to 80 F † Using Non-Ozone Depleting Refrigerants 10 ton air-cooled model 10 ton water-cooled model 2 ton water-cooled model 1 ton air-cooled model

8 to 12 F for water-cooled chillers and 10 to 15 F for air-cooled chillers. ENSURE PROPER SUPERHEAT For air-cooled chillers, make sure fans work properly and coils are clean on the condenser side of the system. For water-cooled chillers, ensure that all flow rates and pressure drops on th

AIR-COOLED Air-Cooled chillers utilize plant ambient air to extract heat from the refrigeration circuit. Fan or blowers move the plant air across generously sized finned condenser coils to permit full rated capacity at design conditions. WATER-COOLED Water-Cooled chillers utilize a secondary plant water source such as cooling tower or city .

air-cooled, water cooled and split systems scroll, screw, or oil free centrifugal compressors precise capacity control & redundancy tanks, pumps and free-cooling modules advanced microprocessor controls highest quality modular chillers air & water cooled chillers for hvac & process cooling. 2

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS 44-254kW Exceeding Efficiency Standards The YORK Amichi Series Air-cooled DC Inverter Scroll Chiller and Heat Pump have been designed to meet tomorrow's efficiency standards today. Delivering performance beyond typical chiller and heat pump efficiency levels, the YORK Amichi Series

Air-cooled chillers are used to produce chilled water to air-side systems such as primary air fan coil systems, constant air volume systems and variable air volume systems in different zones of the building. An air-cooled screw chiller generally comprises a shell and tube evaporator, an air-cooled condenser with

Air-Cooled Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Nominal Capacities: 50 to 410 Tons 179 to 1445 kW Product Data Features/Benefits ComfortLink control Your link to a world of simple and easy to use air-cooled chillers that offer out-standing performance and value. The 30GTN,GTR liquid chillers employ more than the .

Air Cooled Packaged Chillers A P C X - 5 1 0 0 Y Nominal Tonnage Power Supply Code Y : 380-415V/3Ph/50Hz P : 440V/3Ph/50Hz R : 380V/3Ph/60Hz E : 460V/3Ph/60Hz T : 220V/3Ph/60Hz Nomenclature Introduction APCX Series Air Cooled Packaged Chillers are the new generation of SKM chillers. APCX Series have quite and low vibration design and

A wide range of indoor-duty air-cooled, water-cooled, or remote air-cooled condensers as well as outdoor air-cooled chillers fit a variety of applications. . Air-Cooled Condenser Chillers Model NQA04 NQA05 NQA08 NQA10 NQA13 NQA15 NQA20 NQA25 NQA30 Cooling Capacity (tons)1 4 5 8 11 13 15 21 26 31 Set Point Range ( F) 20 to 80 20 to 80 20 to .