Technical data sheetDuPont Tychem 2000 C , TCCHA5TYL00Product DescriptionCAT IIIT3T4T5T6EN1073-2DuPont Tychem 2000 C. Hooded coverall. Stitched and over-taped seams.Thumb loops. Elastication at wrists, ankles, face and waist. Self-adhesive doublezipper flap and chin flap. Yellow.ENEN1149-5 14126CertificationsCertified according to Regulation (EU) 2016/425Chemical protective clothing, Category III, Type 3-B, 4-B, 5-B and 6-BEN 14126 (barrier to infective agents), EN 1073-2 (protection againstradioactive contamination)Antistatic treatment (EN 1149-5) - on insidePackaging ( Quantity/Box )25 per box, individually packed.SizeArticle NumberChest Girth(cm)Body Height(cm)Chest Girth(in)Body ence Number: TCCHA5TYL00Technical Description 1200 EN .pdf Printed on : July 31, 2018 page 1 of 10

Physical PropertiesPropertyTest MethodResultEN ClassColourN/ABasis WeightDIN EN ISO 53683g/m2N/AThicknessDIN EN ISO 534180 µmN/AAbrasion Resistance 7EN 530 Method 2 1500 cycles5 of 6 1EN ISO 7854 Method B 5000 cycles3 of 6 1Flex Cracking Resistance at -30 CEN ISO 7854 Method B 500 cyclesN/ATrapezoidal Tear Resistance (MD)EN ISO 9073-435 N1 of 6 1Trapezoidal Tear Resistance (XD)EN ISO 9073-430 N1 of 6 1Tensile Strength (MD)DIN EN ISO 13934-1160 N3 of 6 1Tensile Strength (XD)DIN EN ISO 13934-1150 N3 of 6 1Puncture ResistanceEN 86318 N2 of 6 1DIN EN 20811 30 kPaFlex Cracking Resistance7Resistance to Water PenetrationSurface Resistance at RH 25%, inside77YellowEN 1149-1 2,5 N/A109N/AN/AOhmEN 1149-1No antistatic treatmentN/AExposure to high TemperatureN/AGarments seams opens at 98 CN/AExposure to low TemperatureN/AFlexibility retained down to -73 CN/AEN 13274-4 Method 3No after flame, no drop formation, hole formationN/AISO 2758475 kPaN/ASurface Resistance at RH 25%, outsideResistance to Ignition7Bursting Strength (Mullenburst)1 According to EN 143252 According to EN 141263 According to EN 1073-2Instructions for Use for further information, limitations and warnings Larger than4 According to EN 1411612 According to EN 116125 Front Tyvek / Back Smaller thanN/A Not ApplicableSTD DEV Standard Deviation6 Based on test according to ASTM D-5727 SeeGarment PerformancePropertyTest MethodResultType 3: Resistance to Penetration by Liquids (Jet Test)EN 17491-3PassN/AType 4: Resistance to Penetration by Liquids (High Level Spray Test)EN ISO 17491-4, Method BPassN/AType 5: Inward Leakage of Airborne Solid ParticulatesEN ISO 13982-2PassN/AType 6: Resistance to Penetration by Liquids (Low Level Spray Test)EN ISO 17491-4, Method APassN/AEN 1073-2 51 of 3 3EN ISO 13935-2 125 NNominal protection factor7Seam StrengthShelf Life71 According to EN 143253 According to EN 1073-212 According to EN 1161213 According to EN 11611information, limitations and warnings11 Based on the average of 10 suits, 3 activities, 3 probes Larger thanTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 2 of 10N/A10 yearsEN Class4 of 6 16N/A5 Front Tyvek / Back6 Based on test according to ASTM D-5727 See Instructions for Use for further Smaller thanN/A Not Applicable* Based on lowest single value

ComfortPropertyTest MethodAir Permeability (Gurley method)2 According to EN 141265 Front Tyvek / BackResultISO 5636-5 Larger than Smaller thanEN ClassNoN/AN/A Not ApplicablePenetration and RepellencyPropertyTest MethodResultEN ClassResistance to Penetration by Liquids, Sulphuric Acid (30%)EN ISO 6530 1 %3 of 3 1Resistance to Penetration by Liquids, Sodium Hydroxide (10%)EN ISO 6530 1 %3 of 3 1Resistance to Penetration by Liquids, o-XyleneEN ISO 6530 1 %3 of 3 1Resistance to Penetration by Liquids, Butan-1-olEN ISO 6530 1 %3 of 3 1Repellency to Liquids, Sulphuric Acid (30%)EN ISO 6530 95 %3 of 3 1Repellency to Liquids, Sodium Hydroxide (10%)EN ISO 6530 95 %3 of 3 1Repellency to Liquids, o-XyleneEN ISO 6530 95 %3 of 3 1Repellency to Liquids, Butan-1-olEN ISO 6530 90 %2 of 3 11 According to EN 14325 Larger than Smaller thanBiological BarrierPropertyTest MethodResultEN ClassResistance to Penetration by Blood-borne Pathogens using Bacteriophage Phi-X174ISO 16604 Procedure C20 kPa6 of 6 2Resistance to Penetration by Contaminated LiquidsEN ISO 22610 75 min6 of 6 2Resistance to Penetration by Biologically Contaminated AerosolsISO/DIS 22611log ratio 56 of 6 2Resistance to Penetration by Contaminated Solid ParticlesISO 22612log cfu 13 of 3 22 According to EN 14126 Larger than Smaller thanTechnical Description 1200 EN .pdf Printed on : July 31, 2018page 3 of 10

Permeation Data for Tychem 2000 CHazard NamePhysicalStateCASBT ActBT 0.1BT 1.0ENSSPRMDPRCum 480 Time150ISOAcetic acid (10%)Liquid64-19-7 480 480 4806 0.040.04 19.2 4806Acetic acid (2%)Liquid64-19-7 480 480 4806 0.040.04 19.2 4806Acetic acid ( 95%)Liquid64-19-7immimmimm30.05ppmAcetic acid ethyl -8immimmimm160.23ppmAcroleic acidLiquid79-10-7immimmimm5.40.2Acrylic d107-13-1immimmimm10.60.005Amino benzeneLiquid62-53-3immimmimm2.10.14Ammonia (gaseous)Vapor7664-41-7immimmimm3.10.001Ammonium aqueous (28%)Liquid1336-21-6immimmimm620.035Ammonium hydroxide mmimm2.10.14Bromine (liquid)Liquid7726-95-6immimmimm 500.0064Butadiene, 1,3- (gaseous)Vapor106-99-0immimmimm Butanal, n-Liquid123-72-8immimmimm220.0063Butanol, 1-Liquid71-36-3immimmimm1.60.057ppmButanol, n-Liquid71-36-3immimmimm1.60.057ppmButyl alcohol, n-Liquid71-36-3immimmimm1.60.057ppmButyraldehyde, n-Liquid123-72-8immimmimm220.0063Carbon latin (10mg/ml)Liquid441575-94-4 240 240 2405 0.0010.001Carmustine (3.3 mg/ml, 10 %Ethanol)Liquid154-93-830 240 24050.0020.001Caustic ammonia (28%)Liquid1336-21-6immimmimm620.035Caustic soda (42%)Liquid1310-73-2 480 480 4806 0.0050.005 2.4 4806Caustic soda (50% at 50 C)Liquid1310-73-2 480 480 4806 0.020.02 9.6 4806Caustic soda (50%)Liquid1310-73-2 480 480 4806 0.0050.005 2.4 4806Chlorine (gaseous)Vapor7782-50-5immimmimm 500.2Chloro ethanol, 2-Liquid107-07-3immimmimm3.10.06ppmChromic acid (CrO3) (44.9%)Liquid1333-82-0 480 480 4806 0.070.07 33.6 4806Chromic acid (H2SO4 x CrO3)(80%)Liquid1333-82-0 480 480 4806 0.0050.005 2.4 4806Cisplatin (1 mg/ml)Liquid15663-27-1 240 240 2405 clophosphamide (20 mg/ml)Liquid50-18-0 10* 240 240 0.0020.002DichloromethaneLiquid75-09-2immimmimm 500.0015BT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 4 of 10

Permeation Data for Tychem 2000 CHazard NamePhysicalStateCASBT ActBT 0.1BT 1.0ENSSPRMDPR64.30.017ppm 0.390.39Diethyl amineLiquid109-89-7immimmimmDimethyl fumarate (27 C)Solid624-49-7177*nm291*Dimethyl ketalLiquid67-64-1immimmnm9.70.11ppmDimethyl ketoneLiquid67-64-1immimmnm9.70.11ppmDoxorubicin HCl (2 mg/ml)Liquid25136-40-9 240 240 240 0.0070.007Epoxy ethane (gaseous)Vapor75-21-8immimmimm1700.02Ethane 1,2-diolLiquid107-21-1 480 480 480 0.050.05556Cum 480 Time150ISO 24 4806 24 4806Ethane nitrileLiquid75-05-8immimmimm160.23ppmEthyl acetateLiquid141-78-6immimmimm12.70.11ppmEthyl ethanamine, N-Liquid109-89-7immimmimm64.30.017ppmEthyl nitrileLiquid75-05-8immimmimm160.23ppmEthylene carboxylic acidLiquid79-10-7immimmimm5.40.2Ethylene ene glycolLiquid107-21-1 480 480 480 0.050.05Ethylene oxide (gaseous)Vapor75-21-8immimmimm1700.02Ethylene tetrachlorideLiquid127-18-4immimmimm 4000.11ppmEtoposide (Toposar , Teva) (20mg/ml, 33.2 % (v/v) Ethanol)Liquid33419-42-0 240 240 2405 0.01 0.01Ferric (III) chloride (40%)Liquid7705-08-0 480 480 4806 0.0050.005 2.5 4806Fluorosilicic acid (33-35%)Liquid16961-83-4 480 480 4806 0.040.04 19.2 4806Fluorouracil, 5- (50 mg/ml)Liquid51-21-8 240 240 2405 0.0020.002Formaldehyde (10%)Liquid50-00-0 480 480 4806 0.10.1 48 4806Formaldehyde (37%)Liquid50-00-0immimm 48060.310.1Formalin (10%)Liquid50-00-0 480 480 4806 0.10.1 48 4806Formalin (37%)Liquid50-00-0immimm 48060.310.1Fuel oilLiquid68476-30-2immimmimm1.7760.01Fuel-oil no 2Liquid68476-30-2immimmimm1.7760.01Gemcitabine (38 mg/ml)Liquid95058-81-415* 240 2405 0.010.003Glycol alcoholLiquid107-21-1 480 480 4806 0.050.05 24 48063.10.06ppm134 48066Glycol chlorohydrinLiquid107-07-3immimmimmHydrochloric acid (32%)Liquid7647-01-0 480 480 4806 0.0010.001Hydrochloric acid (37%)Liquid7647-01-060*265* 48060.460.001Hydrofluoric acid (48%)Liquid7664-39-3717 4806N/A0.005Hydrofluoric acid (60%)Liquid7664-39-3imm6813n/a0.005Hydrofluoric acid (70%)Liquid7664-39-3immimm15*115.30.1Hydrogen peroxide (50%)Liquid7722-84-1 480 480 4806 0.010.01 4.8 4806Hydrogen peroxide (70%)Liquid7722-84-1 480 480 4806 0.020.02 10 4806Ifosfamide (50 mg/ml)Liquid3778-73-2 240 240 2405 550µg/cm²,8min 1IsopropanolLiquid67-63-0immimmimm80.04BT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 5 of 10

Permeation Data for Tychem 2000 CHazard NamePhysicalStateCASBT ActBT 0.1BT 1.0ENKetone propaneLiquid67-64-1immimmnmLimonene d-Liquid5989-27-5immimmimmMercuric II chloride (sat)Liquid7487-94-7 480 480 4806MercuryLiquid7439-97-6 480 480 4806SSPRMDPRCum 480Time150ISO9.70.11ppm29.80.02 0.010.01 4.8 4806 0.090.09 43.2 48062.20.18ppm 0.0010.0014550µg/cm² ,8 min 1 4.8 4806 2.4 4806MethanolLiquid67-56-1immimmimmMethotrexate (25 mg/ml, 0.1 NNaOH)Liquid59-05-2 240 240 240Methyl mimm29.80.02Methyl acetylLiquid67-64-1immimmnm9.70.11ppmMethyl benzolLiquid108-88-3immimmimm5030.033ppmMethyl cyanideLiquid75-05-8immimmimm160.23ppmMethyl iodideLiquid74-88-4immimmimmnm0.07Methyl ketoneLiquid67-64-1immimmnm9.70.11ppmMethylene chlorideLiquid75-09-2immimmimm 500.001Mitomycin (0.5 mg/ml)Liquid50-07-7 240 240 2405 0.0020.002Nitric acid (70%)Liquid7697-37-2 480 480 4806 0.010.01Nitro benzeneLiquid98-95-3immimmimm17.70.001Oleum (30%)Liquid8014-95-718821053nm0.005Oxaliplatin (5 mg/ml)Liquid63121-00-6145 240 2405 0.10.008Paclitaxel (Hospira) (6 mg/ml, 49.7% (v/v) Ethanol)Liquid33069-62-4 240 240 2405 0.01 0.01Perchloric acid (70%)Liquid7601-90-3 480 480 4806 0.0050.005Phenyl amineLiquid62-53-3immimmimm2.10.14Phosphoric acid (85%)Liquid7664-38-2 480 480 4806 0.0050.005 2.4 4806Potassium chromate (sat)Liquid7789-00-6 480 480 4806 0.010.01 4.8 4806Potassium hydroxide (50%)Liquid1310-58-3 480 480 4806 0.0050.005 2.4 -oneLiquid67-64-1immimmnm9.70.11ppmPropene acidLiquid79-10-7immimmimm5.40.2Propenenitrile, 2-Liquid107-13-1immimmimm10.60.005Propenoic acid nitrileLiquid107-13-1immimmimm10.60.005Pyroacetic etherLiquid67-64-1immimmnm9.70.11ppmSodium cyanide (sat)Liquid143-33-9 480 480 4806 0.070.07 33.6 4806Sodium fluoride (sat)Liquid7681-49-4 480 480 4806 0.0050.005 2.4 4806Sodium hydroxide (42%)Liquid1310-73-2 480 480 4806 0.0050.005 2.4 4806Sodium hydroxide (50% at 50 C)Liquid1310-73-2 480 480 4806 0.020.02 9.6 4806Sodium hydroxide (50%)Liquid1310-73-2 480 480 4806 0.0050.005 2.4 4806Sodium hypochlorite (15%)Liquid7681-52-9 480 480 4806 0.050.05 24 4806Sulfuric acid (50%)Liquid7664-93-9 480 480 4806 0.010.01 4.8 4806Sulfuric acid ( 95% at 50 C)Liquid7664-93-9 480 480 4806 0.020.02 9.6 4806Sulfuric acid ( 95%)Liquid7664-93-9 480 480 4806 0.020.020 9.6 48065BT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 6 of 10

Permeation Data for Tychem 2000 CHazard NamePhysicalStateCASBT Act BT 0.1BT 1.0ENSSPRMDPRTetrachloro ethylene, 1,1,2,2-Liquid127-18-4immimmimm 4000.11 ppmTetrahydrofuranLiquid109-99-9immimmimm1830.11 ppmTetramethyl ammonium hydroxide(25%)Liquid75-59-2nm 480 4806N/A0.037Thiotepa (10 mg/ml)Liquid52-24-410 240 2405 0.0050.001TolueneLiquid108-88-3immimmimm5030.033 ppmToluene diisocyanate, 2.4-Liquid584-84-9immimmimm420.00000208Trichloro benzene, 1,2,4-Liquid120-82-1immimmimm8.40.001Vinyl 50ISO ISOBT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 7 of 10 test "%{productPermData16.size() 0}"

Permeation Data for Tychem 2000 CHazard NamePhysical StateCASBT ActBT 0.1BT 1.0EN SSPRMDPRCum 480Time 150ISOBT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 8 of 10 test "%{productPermData17.size() 0}"

Permeation Data for Tychem 2000 CHazard NamePhysical StateCASBT ActBT 0.1BT 1.0EN SSPRMDPRCum 480Time 150ISOBT Act (Actual) Breakthrough time at MDPR [mins]BT 0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins] BT 1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins] EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min] MDPR Minimum detectable permeation rate [µg/cm²/min] CUM 480 Cumulative permeation mass after 480 mins [µg/cm²] Time 150 Time to reach cumulative permeationmass of 150 µg/cm² [mins] ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermins Minutes Larger than Smaller thanimm Immediate ( 4 min)nm Not testedsat Saturated solutionN/A Not Applicable* Based on lowest single valuena Not attained8 Actual breakthrough time; normalized breakthrough time is not availableTechnical Description 1200 EN .pdf Printed on : July 31, 2018 page 9 of 10 test "%{productPermData1.size() 0}"

Important NoteThe permeation data published have been generated for DuPont by independent accredited testing laboratories according to the test method applicable at that time (EN369, ASTM F739, EN374-3, EN ISO 6529 (method A and B) or ASTM D6978)The data is typically the average of three fabrics samples tested.All chemicals have been tested at an assay of greater than 95 (w/w) % unless otherwise stated.The tests were performed at room temperature and environmental pressure unless otherwise stated.A different temperature may have significant influence on the breakthrough time.Permeation typically increases with temperature.Cumulative permeation data have been measured or have been calculated based on steady state permeation rate.Cytostatic drugs testing has been performed at a test temperature of 27 C according to ASTM D6978 or ISO 6529 with the additional requirement of reporting a normalized breakthrough time at0.01 µg/cm²/min.Chemical warfare agents (Lewisite, Sarin, Soman, Mustard, Tabun and VX Nerve Agent) have been tested according to MIL-STD-282 at 22 C or according to FINABEL 0.7 at 37 C.Permeation data for Tyvek is applicable to white Tyvek 500/ Tyvek 600 only and is not applicable for other Tyvek styles or colours.Permeation data are usually measured for single chemicals. The permeation characteristics of mixtures can often deviate considerably from the behaviour of the individual chemicals.Please use the permeation data provided as a part of the risk assessment to assist with the selection of a protective fabric, garment or accessory suitable for your application. Breakthrough timeis not the same as safe wear time. Breakthrough times are indicative of the barrier performance, but results can vary between the test methods and laboratories. Breakthrough time alone isinsufficient to determine how long a garment may be worn once the garment has been contaminated. Safe user wear time may be longer or shorter than the breakthrough time depending on thepermeation behaviour of the substance, the toxicity of the substance, working conditions and the exposure conditions (e.g. temperature, pressure, concentration, physical state).Latest Update Permeation Data: 30/05/2018The garment does not protect against ionizing radiation.This garment and/or fabric are not flame resistant and should not be used around heat, open flame, sparks or in potentially flammable environments.The information provided herein corresponds to our knowledge on the

Trapezoidal Tear Resistance (MD) EN ISO 9073-4 35 N 1 of 6 1 Trapezoidal Tear Resistance (XD) EN ISO 9073-4 30 N 1 of 6 1 Tensile Strength (MD) DIN EN ISO 13934-1 160 N 3 of 6 1 Tensile Strength (XD) DIN EN ISO 13934-1 150 N 3 of 6 1 Puncture Resistance EN 863 18 N 2 of 6 1 Resistance to Water Penetration DIN EN 20811 30 kPa N/A

Related Documents:

DuPont system of financial analysis in 1919 and firstly it was used by the DuPont Corporation of USA in 1920. DuPont Analysis is also known as DuPont identity, DuPont equation, DuPont model or DuPont method. The DuPont analysis is basically based as two tier i.e., n

User Instructions for 3M . Tychem et Tyvek sont des marques déposées de DuPont, utilisées sous licence au Canada. Tychem y Tyvek son marcas registradas de DuPont. Tychem e Tyvek são marcas co

DuPont Froth-Pak Foam Insulation DuPont LiquidArmor Flashing & Sealant DuPont Cavitymate Ultra Wall System Great Stuff Pro Gaps & Cracks DuPont Styrofoam XPS Insulation DuPont Tyvek Fluid Applied WB DuPont Thermax Wall System DuPont Ultra SL Wall System

DuPont /Imron Industrial Strength T 1 W n/a n/a DuPont /Imron 3.5 HG-D T 1 Bk n/a n/a DuPont /Imron 2.1 HG, SG, FT, ST T 21 Bk, W, Yel, Gr n/a n/a DuPont /Imron 2.1 Pr-P P 1 W n/a n/a DuPont /Imron 2.1 HG-D T 1 W n/a n/a DuPont /Imron 2.1 EZ-C C 1 Or n/a n/a Awlgrip /Awlcraft 2000 T 3 Bk, W

DuPont Tyvek proven durability 10 - ageing tests results Achieve optimal airtightness and long-term performance 12 Product Portfolio 14 Application table DuPont membranes 16 DuPont Tyvek roofing underlays DuPont Tyvek Supro / Supro Plus 18 DuPont Tyvek Metal 19 DuPont

HomeWrap, the Tyvek line includes flashing and sealant materials as well as other grades of weather and air barrier sheet products including: DuPont Tyvek CommercialWrap DuPont Tyvek ThermaWrap LE DuPont Tyvek CommercialWrap D DuPont Tyvek DrainVent Rainscreen DuPont

DuPont Flashing Products 10-Year Limited Warranty (Product & Labor): Subject to product label warnings and the specific terms and conditions below, when used in conjunction with DuPont Tyvek Commercial Wrap Products and/or DuPont Tyvek Fluid Applied WB Products and in conjunction with DuPont Thermal Product

- DuPont Safety Model Presentation to DOE Undersecretaries - 1. Topics to Consider DuPont (Tabs 2-4) 2. Felt Leadership and Safety Culture– Principles of an effective safety culture 3. DuPont 2015 Sustainability Goals –Outline and summary of DuPont’s goals for corporate growth, mar