11.17VRV T-SeriesWATER-COOLEDSYSTEMS

Why Consider a Daikin VRV T-SeriesWater Cooled System?One Flexible PackageThe Daikin VRV T-Series Water Cooled is a flexible and modular energy saving alternative to traditional centralized equipmentsolutions such a Chilled Water System or Water Source Heat Pumps (WSHP).The VRV T-Series Water Cooled provides all of the attributes of an Air-cooled VRV system such as low sound levels, advanced comfortcontrol and zoning but with the added application flexibility for cold climates, buildings with an existing water loop infrastructure orgeothermal applications.The long piping capabilities, small refrigerant pipes, compact condensing unit size and ability to take advantage of building diversityand 2-stage heat recovery provide great flexibility in applying the solution to your building whether existing or new constructions.This aids in reducing the overall construction complexity compared to traditional water based systems and helps optimize the totalcost of construction.VRV is built upon 4 basic “Building Blocks” — CondensingUnit, Indoor Unit, Piping, and Controls — providing theattributes of a central chilled water system but with the simplicityof a split system.IndoorUnitThis enhanced system offers energy-efficient and comfortablecooling and heating for many types of applications such as offices,hotels, high-rise buildings and large commercial applications.PipingControlsCondensing UnitVRV T-Series Water Cooled Main Features›› Flexible System design with increased diversityup to 150%*›› Can be applied to both geothermal and boiler/towerapplications as standard with condenser water inlettemperature as low as 14 F* in heating and 23 F* incooling is possible›› Triple-stack capable to deliver up to 36 tons injust under 11 feet ceiling height thanks to thecompact design* Conditions/rules apply. Refer to Installation andEngineering Manual for further details.›› Engineered with heat rejection cancellationtechnology* to eliminate mechanical roomconditioning requirements›› 2-9V variable water flow control logic* as standard toincrease waterside system operational efficienciescompared to previous models›› Drop-down electrical box for easy service tokey components›› Field selectable top or front refrigerant connectionsfor flexible and easy �›››OfficesHotelsHigh-rise buildingsMulti-family complexesShopping mallsOther largecommercialapplicationsVRV T-Series Water Cooled3

What is Daikin VRV T-Series Water Cooled?OverviewCOMMERCIALThe VRV T-Series Water Cooled offers an energy savingalternative to traditional centralized equipment. The systemdesign is based on a modular design concept. It is composedof unified condensing units that require simply connecting a2-pipe refrigerant network for heat pump applications or a3-pipe refrigerant network for heat recovery applications. Thecondensing units are conveniently compact, which not onlyenables transport by elevator possible, but also effectivelysimplifies installation in mechanical rooms. This also savesa great deal of time and labor labor when compared totraditional water based equipment.VRV Water Cooled systems are equivalent to 2-pipe or 4-pipechilled water systems, but also offer a viable alternative toWater-Source Heat Pump solutions. Each connected IndoorUnit can provide heating and cooling independently tosuit zone requirements making these systems suitablefor both open plan, or cellular applications with differentoperation requirements.Geothermal ApplicationThe VRV T-Series Water Cooled system can connect to ageothermal water loop as standard, which makes it one ofthe most energy-efficient air-conditioning systems availablein the market.Underground temperatures remain relatively constant allyear round. They are warmer than the air above it during thewinter and cooler than the air above it during the summer.Standard Operation13465This helps reduce the load on the compressor andprovides substantial energy savings over traditional coolingtower/boiler installations.Geothermal Application(Cooling Tower/Dry Cooler, Boiler)2VRV Water Cooled systems are capable of utilizing thisconstant temperature by exchanging heat with the earththrough a ground heat exchanger.3351 Cooling Tower or Dry Cooler 2 Boiler 3 Indoor Units 4 Refrigerant Pipes5 Condensing Units 6 Water Loop PipingWhy select a VRV T-Series Water Cooled System?›› The efficiency and capacity of air-cooled systems reduce at extreme ambient conditions, causing systems to beoversized and increasing initial cost. Water cooled VRV operation is not affected by outside air temperatures.›› Geothermal energy can be used to heat and cool your building, which can help you gain more LEED points.›› Extreme piping lengths in applications such as high-rise buildings cause capacity reductions. Positioning watercooled condensing units floor-by-floor reduces the capacity reduction and improves the system efficiency.›› Water cooled VRV systems typically require less base refrigerant charge than that of a similar air-cooled VRVsystem and thus can be used in applications with limited allowable refrigerant within the building.›› Condensing units can be linked to existing water piping and utilize the existing heat source to reduce initial costs.›› No external operation sound produced by condensing units to disturb your building neighbors since water cooledVRV systems are installed indoors only.4

Features and BenefitsGeothermal Operation and AdvantagesVRV T-Series Water Cooled can use lakes, rivers and ground loops to takeadvantage of the Earth as a natural heat sink or heat source, eliminatingthe need for equipment such as boilers, cooling towers, or dry coolers.14ºFExtended Water Temperature Operation Range50ºF95ºF 113ºFStandardCondenser water inlet temperature can be as low as 23 F in cooling and14 F in heating. Please note that glycol usage is required when enteringcondenser water temperature is below 50 F. Please refer to EngineeringManual for further details.GeothermalHeating (EWT)23ºF50ºF113ºFStandardGeothermalCooling (EWT)Variable Water Flow ControlCondensing unit can control water control device such as an inverterpump or modulating valve via 2-9V signal based on capacity requirement.This increases waterside system operational efficiencies by reducingthe water flow when possible.Flow ValveInput SignalVariableWater FlowValveInverterPumpIndoor installation makes unit invisible from the outsideBecause the system is water cooled, outside air temperature doesnot affect system capacity. Condensing units are installed inside thebuilding, which enhances design flexibility and makes it easier to adaptto different buildings types.›› Great solution for sound sensitive environments as there is no noisemitigation outside to disturb building neighbors›› Superior efficiency, even in the most extreme outside conditions,especially in geothermal operationHeat Rejection Cancellation TechnologyEngineered with heat rejection cancellation technology to minimize heataddition to mechanical rooms** This function needs to be enabled through field settings.VRV T-Series Water Cooled5

Features and Benefits (Cont.)VRT modecontrol selectionto match userpreferencesThis chart reflects theoperation trend of a VRVsystem when in normaloperation and under VRTcontrol. Actual energysavings through VRT varybased on the buildinglocation, load characteristics,occupancy and systemusage conditions.Basic mode is selected to maintain optimal comfort. VRT is selected to save energy and prevent excessive cooling.Capacity priorityEnergy saving priorityFixed Refrigerant TemperatureVariable Refrigerant TemperatureBASIC MODEAUTO MODEFixed Te - Standard controlFloating target Te depending on heat loadHIGH SENSIBLE MODEFixed target TeSelecting VRT enables operation to be optimised for either energy efficiency or rapid cooling.Floating TePOWERFUL MODEReaction speedVery Fast» Can boost capacity above100% if needed.The refrigerant temperaturecan go lower in cooling thanthe set minimum.» Gives priority to very fastreaction speed.The refrigerant temperaturegoes down fast to keep theroom setpoint stable.Fixed TeQUICK MODEReaction speedFast» Gives priority to fastreaction speed.The refrigerant temperaturegoes down fast to keep theroom setpoint stable.ECOECO MODEMODEMILD MODEReaction speedMediumUnable to change Te» Gives priority to efficiency.The refrigerant temperature goesdown gradually giving priority tothe efficiency of the systeminstead of the reaction speed.2-Stage Heat (Energy) Recovery2-Stage Heat (Energy) Recovery is available betweenindoor units on the same VRV system and then acrossall the systems connected to a common water loop. Thishas a dramatic impact on power consumption and helpsimprove energy efficiency.Stage 1: Heat recovery between indoor units inthe same refrigerant circuit — available on heatrecovery units.Heat rejected from indoor units in cooling mode istransferred to units in areas requiring heating. Thiswaste heat utilization leads to maximizing energyefficiency and reducing electricity costs.Stage 2: Heat recovery between condensing unitsvia the water loop — available on both heat pumpand heat recovery units.Second stage heat recovery is achieved within thewater loop between condensing units, reducingthe use of cooling tower/boiler for more energyefficiency.Stage 2Stage 1Heat recovery between indoor unitsHeat recovery between condensing units(available on heat recovery units)(available on both heat pump and heat recovery units)Cooling tower (Closed type), boilerAll indoor unitsin cooling modeHeat rejectedto loopVRV WCIndoor unitsmainly cooling,partly heatingHeat rejectedto loopVRV WCFull HeatRecoveryVRV WCIndoor unitsmainly heating,partly coolingHeat absorbedfrom loopVRV WCAll indoorunits inheatingmodeHeat absorbedfrom loopVRV WC6* Above system configurations are for illustration purposes only.

Features and Benefits (Cont.)Space Saving – Compact Design & Stacked ConfigurationsCompact casing (Height: 38-9/16” Width: 30-1/8” Depth: 22-1/16”) allows for stacking of the units to maximize spacesaving. Stacked systems can easily fit in mechanical rooms with under 7 ft. (dual stack) or under 11 ft. (triple stack) ceilingsthanks to the reduced unit height.RWEYQ144PCRWEQ144TCeiling39-3/8”12 TON38-9/16”Ceiling12 TON12 TON10.3 ft.6.8 ft.12 TON61-1/2”22-21-11/16”12 TON22”Floor30-1/8”Footprint: 9.3 sq. ft.Weight: 686 lbsFootprint: 4.6 sq. ft.Weight: 423 lbs50% Decrease38% Decrease12-Ton VRV IV PC vs New VRV T-SeriesIdeal Retrofit to ExistingWater Cooled Systems22”Floor30-1/8”30-1/8”24-TonDual Stack Installation36-TonTriple Stack InstallationRetainedcooling towerVRV T-Series Water Cooled can utilizethe existing systems such as coolingtowers, dry coolers and boilersduring renovation for further costsavings.New available spaceAfter renovationBefore renovationEasy Installation and ServicingDeveloped for easy installation and servicing: options tochoose between top or front connection for refrigerantpiping and drop-down switch box for easy access tocomponents.Drop-DownElectrical BoxTop SideRefrigerant PipingConnectionFront SideRefrigerant PipingConnectionSimplified Commissioning and Servicing›› New configurator software designed to simplify thecommissioning and maintenance of the system.›› 3-digit 7-segment digital display on the unit forimproved and faster configuration, commissioning,and troubleshooting compared to previous model.DigitalDisplayProgrammingSwitchesBS1 BS2 BS3VRV T-Series Water Cooled7

Specifications (Cont.)Refrigerant Piping LimitationsLiquid Line Max (feet)ABCDEAVertical Drop164BBetween IDU98CVertical Rise130DFrom 1st Joint130 (295*)ELinear Length540 Actual623 EquivalentTotal one-wayPiping Length980* Upsizing is required. Please refer toInstallation Manual for further details.Service Space Requirements*18VRV T-SeriesWater Cooled

Specifications (Cont.)VRV T-SERIES UNIFIED HEAT PUMP AND HEAT RECOVERY 208-230V & 460V6 72PCYD6ModelCombinationRated Cooling Capacity ¹BTU/hBTU/hPerformance Rated Heating Capacity ²Sound Pressure Level @ 3 ft.dB(A)System Configuration: Heat Pump:HP, Heat Recovery: HRRefrigerantLiquid Pipe (Main Line)in.PipingSuction Gas Pipe (Main Line)in.Discharge Gas Pipe (Main Line)in.%Connection Standard Connectable Indoor Unit Ratio3RatioMaximum Number of Indoor UnitsQty.in.BPHE Inlet Pipe (Female Thread)BPHE Outlet Pipe (Female Thread)in.Drain Pipe (Female Thread)in.Maximum System Water Pressure (BPHE) psiWater Side Standard Inlet Water F(Standard)Temperature Range CoolingStandard Inlet Water FTemperature Range HeatingRecommended Inlet Water FlowgpmRate per Module (minimum)Inlet Water Temperature Range Cooling 4 FWater SideInlet Water Temperature Range Heating4 F(Geothermal)Water Flow Rate5gpmUnitWeight 55138,000154,00060.516 TonRWEQ192TATJURWEQ192TAYDU2 x 1/8N/A1/27/81-1/850 - 8184,000206,00057HPHR5/85/81-1/81-1/8N/A1-1/850 - 150332 x 1-1/42 x 1-1/42 x 3/8536.6251-1/41-1/43/818 32,00057.520 Ton22 TonRWEQ240TATJU RWEQ264TATJURWEQ240TAYDU RWEQ264TAYDURWEQ120T2 x 1-1/81-3/83/41-3/8N/A3/41-1/81-3/8372 x 1-1/42 x 1-1/42 x 3/8412 x 1-1/42 x 1-1/42 x 3/8452 x 1-1/42 x 1-1/42 x 3/850 - 11350 - 11315.9 - 39.6 (13.2)27 - 11323 - 11314 - 9521.2 - 39.6419 / 426423 / 430423 / 4302 x 419 / 2 x 426in.VAAA39-3/8 x 30-3/4 x 21-11/163022.41510.23528.8151338-9/16 x 30-1/8 x 22-1/164536.52016.55044.62520.2%23 - 10016 - 10014 - 10011 - 10035 3528.8 28.815 1513 13Inverter8 - 100208-230V/3Ph/60Hz460V/3Ph/60Hz24 TonRWEQ288TATJURWEQ288TAYDUCombination2 x RWEQ144T26 TonRWEQ312TATJURWEQ312TAYDU2 x RWEQ96TRWEQ120T298,000334,00059Rated Cooling Capacity ¹BTU/hBTU/hPerformance Rated Heating Capacity ²Sound Pressure Level @ 3 ft.dB(A)System Configuration: Heat Pump:HP, Heat Recovery: HRRefrigerantLiquid Pipe (Main Line)in.PipingSuction Gas Pipe (Main Line)in.Discharge Gas Pipe (Main Line)in.%Standard Connectable Indoor Unit Ratio 3ConnectionRatioMaximum Number of Indoor UnitsQty.in.BPHE Inlet Pipe (Female Thread)BPHE Outlet Pipe (Female Thread)in.Drain Pipe (Female Thread)in.Maximum System Water Pressure (BPHE)psiWater SideStandard Inlet Water F(Standard)Temperature Range CoolingStandard Inlet Water FTemperature Range HeatingRecommended Inlet Water FlowgpmRate per Module (minimum) FInlet Water Temperature Range Cooling 4Water SideInlet Water Temperature Range Heating 4 F(Geothermal)Water Flow Rate5gpmElectrical(208-230V)Electrical(460V)12 TonRWEQ144TATJURWEQ144TAYDU330 / 343Dimensions (H x W x D)Maximum Overcurrent Protection (MOP)Minimum Circuit Amps (MCA)Maximum Overcurrent Protection (MOP)Minimum Circuit Amps (MCA)Compressor TypeCompressorCompressor Capacity ControlUnit10 )Electrical(460V)Model8 TonRWEQ96TATJURWEQ96TAYDU274,000308,00063.528 TonRWEQ336TATJURWEQ336TAYDURWEQ96T2 x 1-1/81-3/8492 x 1-1/42 x 1-1/42 x 3/8543 x 1-1/43 x 1-1/43 x 3/8583 x 1-1/43 x 1-1/43 x 3/830 TonRWEQ360TATJURWEQ360TAYDU3 x /850 - 150623 x 1-1/43 x 1-1/43 x 3/8536.6419 423 /2 x 423 / 2 x 430426 43038-9/16 x (30-1/8 x 2) x 22-1/1635 4545 4528.8 36.536.5 36.515 2020 2013 16.516.5 16.58 - 10032 TonRWEQ384TATJURWEQ384TAYDU2 x RWEQ120TRWEQ144T366,000410,000622 x 423 / 2 x 43045 5036.5 44.620 2516.5 20.27 - 10034 TonRWEQ408TATJURWEQ408TAYDURWEQ120T2 x RWEQ144T388,000435,000646 - 10036 TonRWEQ432TATJURWEQ432TAYDU3 x 3/81-5/8643 x 1-1/43 x 1-1/43 x 3/8643 x 1-1/43 x 1-1/43 x 3/8643 x 1-1/43 x 1-1/43 x 3/83 x 423 / 3 x 4303 x 423 / 3 x 4303 x 423 / 3 x 43045 50 5036.5 44.6 44.620 25 2516.5 20.2 20.250 50 5044.6 44.6 44.625 25 2520.2 20.2 20.24 - 1004 - 10050 - 11350 - 11315.9 - 39.6 (13.2)23 - 11314 - 9521.2 - 39.6Weight (230V/460V)lbs.2 x 423 / 2 x 4302 x 419 4232 x 426 430419 2 x 423426 2 x 430Dimensions (H x W x D)Maximum Overcurrent Protection (MOP)Minimum Circuit Amps (MCA)Maximum Overcurrent Protection (MOP)Minimum Circuit Amps (MCA)Compressor TypeCompressor Capacity Controlin.VAAA50 5044.6 44.625 2520.2 20.235 35 4528.8 28.8 36.515 15 2013 13 16.535 45 4528.8 36.5 36.515 20 2013 16.5 16.5%5 - 1005 - 100¹ Indoor temp.: 80 FDB, 67 FWB/inlet water temp.: 85 F/ Equivalent piping length : 25 ft., level difference : 0 ft.² Indoor temp.: 70 FDB, 60 FWB/inlet water temp.: 70 F / Equivalent piping length: 25 ft., level difference : 0 ft.3Varies based on indoor and condensing unit model selected; refer to Engineering Manual for details.4Application rules apply below 50 F. Please contact your local Daikin office for design assistance and approval.5 - 1003 x 423 / 3 x 43038-9/16 x 30-1/8 x 22-1/1645 45 4545 45 5036.5 36.5 36.536.5 36.5 44.620 20 2020 20 2516.5 16.5 16.516.5 16.5 20.2Inverter5 - 1004 - 100Please note that a water strainer (standard accessory for the T-Series, field supplied for the PC-series) is requiredfor each condensing unit.6PC series model. Some features and benefits may not be available for this model.5VRV T-Series Water Cooled9

VRV Indoor UnitsDesigned for premium comfort and versatility, Daikin's wide selection of ducted and duct-free indoor units witha sleek and sophisticated design provides zoning flexibility and comfort control for almost any application.INDOOR UNIT 362.53423.5484544.5605726968FXMQ-PBVJUDC-Ducted Concealed Ceiling(Medium Static)DUCTEDFXDQ-MVJUSlim Duct Built-InConcealed Ceiling UnitFXTQ TAVJUMulti-Position Air Handling Unit(Upflow, Downflow, Horizontal Leftand Horizontal Right)FXMQ-MVJUConcealed Ceiling Unit(Medium Static)FXNQ-MVJU9 ConcealedFloor- Standing UnitFXFQ-TVJURound Flow Sensing Cassette,Ceiling MountedFXUQ-PVJU4-Way BlowCeiling-Suspended CassetteDUCT-FREEFXZQ-MVJU92' X 2' 4-WayCeiling-Mounted CassetteFXEQ-PVJUCeiling-Mounted Cassette(Single Flow)FXHQ-MVJUCeiling-Suspended UnitFXAQ-PVJUWall-Mounted UnitFXLQ-MVJU9Floor-Standing UnitComfort cooling/heating (12 types 70 models)Condensate pump standardOutside air connection possibleDZK (Daikin Zoning Kit)The optional DZK increases the flexibility of the Daikin VRV and SkyAir systems in both residential andcommercial applications by adding a Zoning Box to an indoor unit fan coil (FXMQ-P or FBQ-P series,respectively) allowing several separate ducts to supply air to different individually controlled zones.DAIKIN ZONING KIT (DZK) – KIT STRUCTURE AND GENERAL TECHNICAL DATAZoning Box with Control BoxDZK Product red Thermostat Wireless Thermostat Wireless Lite ThermostatDZK-MTS-3-WDZK-ZTS-3-WDZK-LTS-3-WBACnet InterfaceDZK-BACNET-3

Air Treatment SystemsDaikin’s Outside Air Processing Unit can combine fresh air treatment and air conditioning, supplied from a single system.The compact Energy Recovery Ventilator is designed to improve indoor air quality while reducing the overall HVAC system powerconsumption. This is achieved by providing fresh outside air and recovering waste heat from exhaust air leaving the conditioned space.VRV Refrigerant PipingVRV Control WiringHigh Efficiency Filter (MERV 8 and MERV 13)Ventilation SystemPower SupplyAirflow RateOUTSIDE AIR PROCESSING UNIT, FXMQ-MFVJUENERGY RECOVERY VENTILATOR, VAM-GVJUConnectableNot connectableConnectableOptionAir supplyNot availableAir supply and Air 0/600/5001200/1200/9306359881236CFMVRV ControlsOptimized for VRV technology, Daikin controls provide highly scalable solutions for all applications and budgets. VRV controls offersolutions to meet your project controls needs from individual zone control with local controllers to centrally controlling the buildingwith Centralized Controllers and/or interfacing with Building Management Systems (BMS) for comfort control in an easily managedand operated system.PROJECT REQUIREMENTSDAIKIN VRV CONTROLSNavigationSimplified RemoteintelligentControllerRemote ControllerTouch ControllerIndividual zone controlIndependent cool and heat setpointsIndividual zone control with weeklyprogrammable schedulingBasic central point on/off control of allair handling unitsAdvanced multi-zone control of small tomedium size projectsAdvanced multi-zone control of largecommercial projectsAdvanced multi-zone control with schedulinglogic and calendarAutomatic cooling/heating changeoverfor heat pump systemsSingle input batch shutdown of all connectedair handlersWeb browser control and monitoringvia Intranet and InternetE-mail notification of system alarms andequipment malfunctionsMultiple tenant power billing for sharedcondenser applicationsTemperature set-point range restrictionsGraphical user interface with floor plan layoutStart/stop control of ancillarybuilding systems*Daikin VRV integration with BACnet basedautomation systemsDaikin VRV integration with LonWorks based automation systemsDaikin VRV integration with Modbus basedautomation systems* intelligentTouch ManagerBACnet InterfaceLonWorks InterfaceModbusInterface n nnn nnn nnnnnn nnn Requires one or more DEC102A51-US2 Digital Input/Output units or WAGO DO module (for use with iTM only). Native application or feature for this device. n Dependent upon capabilities of the third party energy management systemVRV T-Series Water Cooled11

About Daikin:Daikin Industries, Ltd. (DIL) is a global Fortune1000 company which celebrated its 90thanniversary in May 2014. The company isrecognized as the largest HVAC (Heating, Ventilation,Air Conditioning) manufacturers in the world. DILis primarily engaged in developing indoor comfort systemsand refrigeration products for residential, commercial andindustrial applications. Its consistent success is derived, inpart, from a focus on innovative, energy-efficientand premium quality indoor climate and comfortmanagement solutions.Before purchasing an appliance in this document, read importantinformation about its estimated annual energy consumption,yearly operating cost, or energy efficiency rating that is availablefrom your retailer.WARNINGS:››››Always use a licensed installer or contractor to install thisproduct. Do not try to install the product yourself. Improperinstallation can result in water or refrigerant leakage, electricalshock, fire or explosion.Use only those parts and accessories supplied or specifiedby Daikin. Ask a licensed contractor to install those parts andaccessories. Use of unauthorized parts and accessories orimproper installation of parts and accessories can result inwater or refrigerant leakage, electrical shock, fire or explosion.››Read the User’s Manual carefully before using this product.The User’s Manual provides important safety instructions andwarnings. Be sure to follow these instructions and warnings.››For any inquiries, contact your local Daikin sales office.The “Daikin” and “VRV” trademarks are owned by Daikin Industries, Ltd. andRegistered in the U.S. Patent and Trademark Office.2017CB-VRVWT 11-17

The Daikin VRV T-Series Water Cooled is a flexible and modular energy saving alternative to traditional centralized equipment solutions such a Chilled Water System or Water Source Heat Pumps (WSHP). The VRV T-Series Water Cooled provides all of the attributes of an Air-cooled VRV

Related Documents:

VRV IV HP VRV IV HR ASHRAE 90.1 2016 Air Cooled HP ASHRAE 90.1 2016 Air Cooled HP. 7. SYSTEM OVERVIEW. Simple Modular Design. The Features of . VRV. Features & Benefits to Using . VRV . The benefits of . VRV. equipment can be categorized by three core features: Drei ct expansoi n systems (those . that use refrigerant to directly . condition the .

3. Hi-VRV The complete air conditioning system 44 Variable Refrigerant Volume 46 VRV Inverter heat pump series 46 VRV Heat recovery series 47 VRV Plus series using R-407C 48 VRV Plus series using R-22 49 VRV Indoor units 50 Heat Recovery Ventilation 57

VRV IV heat recovery, heat pump, replacement and water cooled VRV IV 360 efficiency 152392 VRV IV HEAT RECOVERY

Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 80 F chilled water. MAXIMUM SERIES † Air & Water-Cooled † 1/4 to 40 Tons † 20 F to 80 F † Using Non-Ozone Depleting Refrigerants 10 ton air-cooled model 10 ton water-cooled model 2 ton water-cooled model 1 ton air-cooled model

A VRV system is similar to a chiller but circulates refrigerant to each zone instead of water A VRV heat pump system has performance and design attributes similar to a 2 pipe chiller A VRV heat recovery system has performance and design attributes similar to a 4 pipe chiller system ¡ Industry Leade

VRV Pricelist 2019-2020 3 Highlights NEW VRV IV C series RXYLQ-T VRV IV heat pump, optimised for reliable heating in extreme conditions ʯ Guaranteed operation down to -25 C and stable heating capacity available down to

VRV indoor units combine with residential indoor units, all in one system PCV1131. 1 Meet the new single outdoor unit series, connectable to both VRV and residential indoor units First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for nearly 30 years. Now,

Box 1.1 The power of language Former Russian satellite countries Estonia and Latvia have made fluency in Estonian and Latvian, respectively, a requirement of citizenship, thus creating a potential problem for millions of Russian-speaking citizens who have lived in these countries for years. An Amsterdam city councilor proposed a law mandating that Dutch be spoken in Islamic mosques in his city .