Single Phase Multi-Tariff ANSI MeterEDMI NC30Single Phase Multi-Tariff ANSI MeterUser ManualPDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterContent1. Product Description . 12. Total kWh Register . 23. Meter Memory . 24. Event Record . 25. LCD display during power off. 26. Maxim Demand. 27. Multi-Tariff energy, maximum 4 tariff (TOU) . 28. Programming Password Protected . 29. LED indicator . 310. LCD display. 310.1.The main symbol explanation: . 310.2.Normal scroll mode (Table 1) . 410.3. Default Display scroll mode . 411. Communication Port . 512. Dis-connect Relay. 513. Wiring Connect. 514. Component Descriptions . 615. Meter Outline Size. 916. Default Parameter Setting . 9Appendix 1: Specification . 10Appendix 2: Faceplate . 13PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterSingle Phase Multi-Tariff ANSI MeterVersion1.0.21.0.31.0.41.0.51.0.6Date 3.21Description of RevisionAdd New DetailsRenameAdd Link optionalAdd maxim demand1. Product DescriptionSocket type, OutdoorComplied with C12.1 C12.10 C12.18 C12.19 C12.20LCD 6 1 Energy display way, Display instantaneous item:Voltage,Current, Active Power.Communication port: optical port,RS485,RF,and PLC OptionalMax 4 rates can be set, default T1Max Demand display2 levels of password12 months History metering data and 50 events of power on/off and meter resetDis-connect Relay optionalThe NC30 meterFigure 1-1 NC30 Meter1PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI Meter2. Total kWh RegisterThe total kWh is displayed on the LCD by 6 digits with one decimal.The total kWh register range is 000000.0-999999.9 kWh.3. Meter MemoryThe history data can store 12 months .The history data include: Accumulative total and max 4 rates of Wh[abs(Wh ) abs(Wh-)];Accumulative total Wh-.4. Event RecordThe energy meter can record below events with time stamp;total 50 events.Power on.Power off.Reset Energy data.Reset event log.Reset [energy data event log].5. LCD display during power offThree display modes(can be set):1. Always display Accumulative Wh[abs(Wh ) abs(Wh-)].2. Displaying Accumulative energy for setting time then no display.3. No Display.Default LCD display during power off is Mode 1.6. Maxim Demand1.2.3.4.Record T1 active (abs(Wh ) abs(Wh-))maxim demand ,T2 active maxim demand,T3active maximdemand,T4 active maxim demand,and the time of the corresponding maxim demand.Use the slip mode, demand cycle / slip time 15 min; demand cycle 60 min, sliding time demand cycle.Demand decimal use 4 digits,Save one historical demand data,and clear the demand data when power energy save auto.7. Multi-Tariff energy, maximum 4 tariff (TOU)The meter can be up to 4 tariffs per days. And the time interval can be programmed by software.Default Tariff is Single Tariff, T1.8. Programming Password ProtectedMeter must first through the password confirmation, then do the programming or other special operations.There are two meter securities.Level 1, for all permissions. 1122334455;Level 2, Read only permission, 1111111111.2PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI Meter9. LED indicatorA high light LED is mounted on the front of the meter, it will blink/pulse at a rate proportional to themeasured load if the current through the meter more than starting threshold. The pulse value is identifiedon the meters nameplate. The pulse can be used for checking the meter accuracy.10. LCD displayThe meter LCD shows 6 1 digits power consumption in kWh, without backlight. The big size of the digits(13mm 6mm) and clearly identification of display value make meter reader easily to get the data indistance.View direction: 6 o'clockPolarizer mode: Reflective (long life and UV)Operating temperature :- 40 C 80 CStorage temperature:- 45 C 85 CFigure 9-1 LCD symbol10.1. The main symbol explanation:SymbolExplanationLCD display 7 digits;The energy display as 6 1 digits.(000000.0 999999.9kWh)Display kWh energy value & date and time.Mode 1: Display instantaneous item:Voltage,Current, Active Power.Mode 2: Display data identification(see table 1)Disconnect Relay DisplayExport/import energy symbol;Simulation and percentage of energy accumulated comparison to KhvalueCommunication symbol (display when comm)Program symbolCurrent running Tariff indicationUnit of Instantaneous Voltage,Unit of Instantaneous Current,Unit of Instantaneous Active Power.Unit of energy3PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI Meter10.2. Normal scroll modeNo. Data Identification(Table 1)Normal scroll mode10.1.0Import Energy (Tariff 1 Tariff Display)20.2.0Import Energy (Tariff 2 Tariff Display)30.3.0Import Energy (Tariff 3 Tariff Display)40.4.0Import Energy (Tariff 4 Tariff Display)50.5.0Import Export Energy (Tariff 1 Tariff Display)60.6.0Import Export Energy (Tariff 2 Tariff Display)70.7.0Import Export Energy (Tariff 3 Tariff Display)80.8.0Import Export Energy (Tariff 4 Tariff Display)90.9.0Import Energy (Total) Voltage101.0.0Import Energy (Total) Current(Total)111.1.0Import Energy (Total) Current(I1)121.2.0Import Energy (Total) Power131.3.0Import Export Energy (Total) Voltage141.4.0Import Export Energy (Total) Current(Total)151.5.0Import Export Energy (Total) Current(I1)161.6.0Import Export Energy (Total) Power171.7.0Date181.8.0192.0.1TimeT1 maxim demand202.0.2T2 maxim demand212.0.3T3 maxim demand222.0.4T4 maxim demand232.1.1T1 maxim demand Date242.1.2T2 maxim demand Date252.1.3T3 maxim demand Date262.1.4T4 maxim demand Date272.2.1T1 maxim demand Time282.2.2T2 maxim demand Time292.2.3T3 maxim demand Time302.2.4T4 maxim demand Time10.3. Default Display scroll modeNoStatus1Power on2Power offPDF pdfFactory ProNormal scroll modeImport Export Energy (Total) VoltageImport Export Energy (Total) Current (I1)Import Export Energy (Total) PowerImport Export Energy (Total) Voltage4www.fineprint.cn

Single Phase Multi-Tariff ANSI Meter11. Communication PortNo1234Optical portRS485 portRFportPLCportexplanationANSI type 2 with 9600bpsBaud Rate 9600 BPS (Optional)Optional (RF915MHZ)Optional12. Dis-connect RelayDis-connect Relay : Optional.13. Wiring ConnectFigure 12-13-wire, 1-phaseFigure12-2 Internal connect(FM2S without Dis-connect Relay)Figure 12-4Figure12-3 Internal connect(FM2S with Dis-connect Relay)2-wire, 1-phase5PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterFigure12-5 Internal connect(FM2S without Dis-connect Relay)Figure12-6 Internal connect(FM1S with Dis-connect Relay)14. Component DescriptionsThe components descriptions of the meter are shown in Figure 13-1 Figure 13-8.Figure 13-1: Basic NC30 Meter Components FM2SFigure 13-2:Dis-connect Relay NC30(100A) Meter Components FM2S6PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterFigure 13-3:Dis-connect Relay NC30(200A) Meter Components FM2SFigure 13-4: Basic NC30(100A/200,Current Transformer) Meter Components FM1SFigure 13-5: Basic NC30(100A,Shunt) Meter Components FM1S7PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterFigure 13-6: Dis-connect Relay NC30(100A,Shunt) Meter Components FM1SFigure 13-7: Dis-connect Relay NC30(100A,Current Transformer) Meter Components FM1SFigure 13-8: Dis-connect Relay NC30(200A,Current Transformer) Meter Components FM1S8PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI Meter15. Meter Outline SizeFigure 14 Meter Outline Size16. Default Parameter SettinglDefault Tariff setting:Single rate; T1;lDisplay alternation:5 seconds.lDefault LCD display during power off:Accumulative Wh[abs(Wh ) abs(Wh-)].lLCD Display during power on:Accumulative Wh[abs(Wh ) abs(Wh-)] Active power/ Voltage/ Current.lSecurity password:Level 1: 1122334455;Level 2: 1111111111.lMeter RTC:Philippines Time;lCommunication Port :Optical portlDis-connect Relay:NO.lMeter No.:According to the bar code on the meter.9PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterAppendix 1: SpecificationItemParameterANSI standards complied withC12.1 C12.10 C12.18 C12.19 C12.20AccuracyMeet ANSI C12.10 class 0.5MountingSocket typeFM2S, CL200Meter type, form designationand current classFM2S, CL100FM1S, CL200FM1S, CL100Operating Voltage80% 120%UnCL200: 30ATest Current(TA)CurrentCL100: 15ACurrent range that guaranteesaccuracyStarting CurrentTestConfidenceTemperatureCommunication PortSecurityCL200: 0.6 200A (2%TA Imax)CL100: 0.3 100A (2%TA Imax)CL200: 0.030A(30mA)CL100: 0.015A(15mA)Frequency60Hz 5%Kh10Kt1.0Power supply typeTransformer typeCurrent sampling modeCurrent transformerPower ConsumptionVoltage circuit: 1W, 5VACurrent circuit: 0.25VA/EachImmunity to impulse voltageSurge 8kV(1.2/50US)Insulation strength4kV,60Hz for 1 minRelative humidity0% 95% no condensationOperating Temperature- 40 C 80 CStorage and TransportationTemperature- 45 C 85 CLCD Operating Temperature- 40 C 80 CClock accuracy 0.5 s/d, at 23 CBatteryLi-SOCI2, 3.6V,1200mAh for clock and LCD displayduring power off.Optical portANSI type 2 with 9600bpsRS485 portOptionalRFportOptionalPLC portOptionalMeter security2 levels of password:Class 1:All permissions.10PDF pdfFactory Pro(Un 240V/120V)www.fineprint.cnDefault:1122334455

Single Phase Multi-Tariff ANSI MeterClass 2: Read only permission. Default:1111111111DemandMaxim demandMaxim demand ;date; time;Dis-connectRelay15(100)A30(200)AOptionalLCD layout and characters &symbols on LCD's meanings(Please see 9. LCD Display)LCD size54mm x 34mmLCD biggest characters' size13.0mm x6.0mmLCD biggest characters'segment width1.7mmLCD with backlightNoNumber of LCD display digits7Energy display way6 integers 1 decimalVoltage,Current & Active Power3 digitsDisplay wayLCDLCD display item ID3 (No ID when display voltage,current,and power )Display interval5sDisplay data update rate1sSign 'Yes' at 'metercolumn can be optionaldisplayed on LCDdata'YesDefault LCD displayduring power onAccumulative Wh[abs(Wh ) abs(Wh-)] RMS VoltageAccumulative Wh[abs(Wh ) abs(Wh-)] RMS CurrentAccumulative Wh[abs(Wh ) abs(Wh-)] RMS PowerT1 (Please see 9. LCD Display)Default LCD display duringpower offAccumulative Wh[abs(Wh ) abs(Wh-)]LED1 LED (Active Energy Pulse),1000imp/kWhAccumulative total and 4 ratesYesof Wh[abs(Wh ) abs(Wh-)]Accumulative total and 4 ratesYesof (Wh ) and (Wh-)Meter dataMaterialInstantaneous frequencyYesInstantaneousVoltage,Current,Active PowerYesCurrent date & timeYesEnergy data resetYesHistory metering data12 monthsEvent logRecord latest 50 events (power on,power off,energyreset events with time stamp)Single layer of upper coverTransparent flat face coverUpper coverFull Circle; Color White11PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterOptical port metal plate430 grade stainless steel,thickness min 1.2 (inner)Number of sealable position1Max 4 rates (each rate's period isTariffFaceplateprogrammed by software)Default rate setupT1 (Single rate)Faceplate colorColor:WhiteFaceplate layoutRefer to Appendix 2New EDMI logo on faceplateSerial numberBar codeMCULinkYesto be nominated by EDMIto be nominated by EDMI39 codeNEC 78F0485;Outside, insideoptional12PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI MeterAppendix 2: 12.13.14.15.16.17.18.10111213WindowsMeter typeNumber of wires for the metered serviceNominal VoltageCurrent ClassTest amperesNominal FrequencyANSI C12.10 Form NumberWatthour constantAccuracy classMeter ConstantOptical portMonth and Two digit year of manufactureEDMI logo / Manufacture of meterWiring connectUtility information and bar code area /Meter serial numberTest constantMeter Pulse13PDF pdfFactory Prowww.fineprint.cn14

Single Phase Multi-Tariff ANSI Meter19.FCC Caution.§ 15.19 Labelling requirements.This device complies with part 15 of the FCC Rules. Operation is subject to the followingtwo conditions: (1) This device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may cause undesired operation.§ 15.21 Information to user.Any Changes or modifications not expressly approved by the party responsible forcompliance could void the user's authority to operate the equipment.§ 15.105 Information to the user.Note: This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, the useris encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver isconnected.-Consult the dealer or an experienced radio/TV technician for help.14PDF pdfFactory Prowww.fineprint.cn

Single Phase Multi-Tariff ANSI Meter 1 Single Phase Multi-Tariff ANSI Meter Version Date Used Description of Revision 1.0.2 2013.01.06 1.0.3 2013.02.21 Add New Details 1.0.4 2013.06.17 Rename 1.0.5 2013.08.20 Add Link optional 1.0.6 2014.03.21 Add maxim demand 1. Product Description Socket type, Outdoor Complied with C12.1 C12.10 C12

Related Documents:

electronic distance measuring instruments (EDMI). Regular checks and documentation of EDMI calibration over a CBL provides surveyors with valid evidence of the proper function of their distance measuring equipment. To assure the measuring capabilities of an EDMI have not significantly deteriorated, known distances forming a

Rick Oliver NC30 Conversions, Spares & Advice Tel: 44 (0)1603 720387 email: RickNC30@gmail.com Carb needle shims (precision machined) 0.5 or 1.0mm 4/set of 4 Main jets (up to #160) - Std Keihin type - 12/set Dynojet - 20/set (Honda & Keihin jets have the same 2.5 size inc

Maximum air volume 250 l/s Minimum air volume 60 l/s Minimum air volume 120 l/s (in case of reheat) Terminal size 200 mm Max. pressure loss 38 Pa Max. discharge sound index NC30 (@250Pa p) Max. radiated sound index NC30 (@250Pa p) Ordering example: type - model - handing NBOJAOB - 200R Manufacturer: HC Barcol-Air Installation .

wound 3 phase motors. Rotary Phase Converter A rotary phase converter, abbreviated RPC, is an electrical machine that produces three-phase electric power from single-phase electric power. This allows three phase loads to run using generator or utility-supplied single-phase electric power. A rotary phase converter may be built as a motor .

A static phase converter is one that externally changes a three phase motor to a capacitor-start, capacitor-run single phase motor; running at approximately the same amperage as a single phase motor of the same horse-power. The single phase amp draw of a three phase motor on our Phase Splitter is 1 1/2 times the three phase name-plate amps.

6.2.1.Conventional Single Phase to Three-Phase Power Converter Circuits In the classical method of single-phase to three-phase conversion the single-phase power supply is given to the converter, which can either be full, or half bridge type, in cascade with a three-phase inverter with a dc link capacitor in between. The

individuals out of the system. 2) Single Channel - Multi Phase . The term multiphase show there are two or more services are executed sequentially. 3) Multi-channel systems - single phase . Multi-channel systems - single phaseoccurs where two or more service facilities fed by a single queue. 4) Multi Channel - Multi Phase . This system shows .

Beste Freude Sprachniveau: B1 2 bis 4 Unterrichtseinheiten Sprachmaterial: Texte auf PASCH-net zum Thema: „Beste Freunde“: Lernziele Die Lernerinnen und Lerner setzen sich mit dem Thema „Beste Freunde“ auseinander; - lernen Wortschatz zum Thema „Freundschaft“; - verstehen Interviews zum Thema; - formulieren ihre eigenen Vorstellungen zum Thema; - tauschen sich über die eigenen .