Fire Solutions - Fire-Lite Alarms

2y ago
21 Views
3 Downloads
2.25 MB
12 Pages
Last View : 17d ago
Last Download : 3m ago
Upload by : Kaleb Stephen
Transcription

Fire SolutionsInnovation That Endureswww.firelite.com1

Fire-Lite Alarms has a legacyof simple, reliable life-safetysystems. By designing advancedtechnology that’s also easy to use,Fire-Lite makes protecting whatmatters most easy – year afteryear. In a world where anything canchange in an instant, you can counton the consistency of Fire-Lite.Fire-Lite - Innovation that Endures.Table of Contents3 Addressable Fire AlarmControl Panels4 Emergency Command Center6 Conventional Fire AlarmControl Panels7 Releasing Control Panels8 Sychronized Power Supplies,Pull Stations, and Annunciators9 Addressable Smoke Detection,Wireless Technology,and Communicators10 Complete Fire Alarm System11 Quick Reference Guide2

Addressable Fire Alarm Control PanelsFire-Lite Alarm’s innovative, addressable control panels offer a wide rangeof capabilities to provide superior value and flexibility. They are easy to installand program with notification appliance circuit (NAC) synchronizationand enable emergency personnel to quickly locate a fire. The built-inLiteSpeed protocol ensures the fastest possible device responsetimes to help reduce property damage and save lives.MS-9600LSand MS-9600UDLSEndurance SeriesES-50X and ES-200X Single SLC that provides support for 50 (ES-50X)or 198 (ES-200X) addressable devices. Upload/download panel programming databaseand flash firmware with USB thumb drive. Support for addressable multi-criteria fire and CO detector. 4 programmable function keys to save time. Built-in Class-A capability for all 4 NACs; no optional card required. Trouble indication for SLC devices not programmed. Integrated SWIFT display driver and annunciator built-in to panel. Notification appliance circuits have built-in sync for the industry’sleading manufacturers including System Sensor , Wheelock ,and Gentex . Up to 159 detectors and 159control/monitor modules.(total of 318 devices) per SLC(636 with SLC-2LS option card). LiteSpeed protocol for SLCcommunication polls 10 devicesat a time and operateson standard, unshielded wire. Auto-programmable functionreduces installation time. Advanced fire technologyincludes sensitivity testingand automatic drift compensation. 4 programmable Class Band 2 Class A NACs.3

Emergency Command Center (ECC)Fire-Lite Alarm’s Emergency Command Center (ECC) leverages advanced technology and 60 years of life-safetyexperience to deliver critical messages through non-proprietary systems. The ECC is ideal for any building that needsa flexible, multi-zoned, and highly configurable fire evacuation and mass notification system that’s easy to maintain.ECC-50/100 PrimaryOperator Console Seamless integration and controlwhen connected to select Fire-Liteaddressable panels through theANN/ACS communication bus. May be used with any UL-listedcontrol panel (messages canbe initiated by using a dry contactor via a fire alarm NAC circuit). Includes a single 25 volt, 50 wattspeaker circuit (upgradableto 100 watts and 2 speakercircuits with optional amplifier). Speaker circuits are expandableby up to 8 outputs (withan optional ECC-CE6 module). Can support up to 14 prerecordedmessages that are fieldprogrammable for up to 60seconds of message playback.4ECC-FFTFire Fighter Telephone Built-in 2 Amp NAC outputwith sync generator. 8 Command Input Circuitsthat can be used to activatemessages 1 to 8. Optional amplifier can beconfigured as a backup in theevent the primary amplifier fails.Amplifiers are independentlypowered to eliminate systeminterruption during a short circuitcondition. Optional transformer conversionmodule available for 70.7 voltspeaker operation. Supports charging up to 26AHbatteries. Provides supervision, annunciation,and control for up to 24 remotetelephone handsets. Built-in auto-program featurefor quick installation. Can be wired for class A (Style 6or Style 7) or class B (Style 4)configuration. Can be configured for Multi-PhoneJack Audio Circuit supervision. Allows simultaneous operationof up to 10 firefighter remotehandsets.

ECC-RPUECC-LOCLocal Operator Console Remote Page Unit Provides complete controland has an interface similarto the ECC-50/100 Includes built-in microphonefor ALL CALL paging along withmessage and zone control. A maximum of 8 ECC-LOCs(or combination of other remotedisplay consoles). Includes built-in microphonefor ALL CALL paging alongwith message control. A maximum of 8 ECC-RPUs(or combination of other remotedisplay consoles). Additional 9th button can be usedto activate an optional monitormodule that can be mountedinside the cabinet for applicationssuch as HVAC shutdown.ECC-RM Remote Microphone Includes built-in microphone for ALL CALLpaging over available speaker zones. A maximum of 8 ECC-RMs(or combination of other remote display consoles).ECC-50DA, ECC-50BDA,and ECC-125DADistributed AudioAmplifiers Externally mounted amplifiersprovide an additional 50 or 125watts of addressable audiopower when connectedto the ECC-50/100. Up to 8 distributed amplifierscan be connected to theECC-50/100 for a total of 1100watts of audio power. Includes 4 built-in speakercircuits, which are expandableto 8 circuits with an optionalECC-CE4 module (a maximumof 24 audio circuits). Speaker output voltage is fieldconfigurable on ECC-50DA for either25 volts or 70.7 volts of operation. Includes a built-in power supplyand backup battery charger. ECC-50BDA provides 50 wattsof power with 50 watts as backup.It can also provide 100 watts ofpower (100 watts primary and 50watts of backup power requiresECC-50WBU).5

Conventional Fire Control PanelsFire-Lite’s 24-volt conventional fire alarm control panels (FACPs) bring the latest in microprocessor technologyto conventional fire controls. With 2-zone, 4-zone, 5-zone, and 10-zone configurations, these units offeroptions to meet most local, state, and national requirements in the most efficient and effective way possible.MS-2MS-5UD 2 initiating zones that are compatible with 2- and 4-wire smokedetectors, 1 zone programmablefor combo, supervisory,and waterflow. 5-zone Style B (Class B) or 5-zone Style D (Class A)with optional module. 1 Notification Appliance Circuit(NAC) with built-in horn/strobesynchronization. 3.0 amps maximum alarm current.MS-4 4 initiating zones that are compatiblewith 2- and 4-wire smoke detectors,1 zone programmable for combo,supervisory, and waterflow. 2 Notification Appliance Circuits(NAC) with built-in horn/strobesynchronization. Optional module converts all 4 initiating zones and 2 NACs to Class A. 3.0 amps maximum alarm currentexpandable to 6.0 amps withoptional second transformer. 3.0 amps maximum alarm current.MS-10UD 10-zone Style B (Class B) or 10-zone Style D (Class A)with 2 optional modules. 7.0 amps maximum alarm current.MS-5UD/MS-10UD Shared Features and Specifications 4 NAC Circuits Style Y (Class B) or 4 NACCircuits Style Z (Class A) with optional modules. Built-in horn/strobe NAC synchronizationwith Remote Synchronization Output. Integral 80-character LCD display with backlighting and keypad. Annunciator bus supports up to 8 devices, including ANN-80LCD Remote Annunciator, ANN-S/PG remote serial or parallelprinter gateway, ANN-RLY, 10 form C relay board, ANN-LEDZone annunciator, and ANN-I/O LED driver board for graphicannunciators. Built-in 2-line digital communicator for off-premises monitoring. 3 Form-C programmable relays.All Conventional Fire Control Panels Support System Sensor , Wheelock , Gentex , Faraday , and Amseco devices.6

Releasing Control PanelsDesigned to meet the most demanding conventional releasing applicationswith the flexibility and reliability typically found only in advanced systems,Fire-Lite’s Deluge/Preaction and Agent Release models offer rich featuressuch as built-in, easy-to-use programming templates, adjustable delaytimers, and more for customized protection.MRP-2001Deluge/PreactionControl PanelMRP-2002Agent ReleaseControl Panel 6-zone Style B (Class B)or 6-zone Style D (Class A)with optional modules. 4 Programmable Output CircuitsStyle Y (Class B). Outputs programmablefor Releasing Solenoids. Dual hazard operation. Adjustable waterflow dischargetimer and 2 soak timers. Cross-zone capability. Pre-programmed and customapplication templates. Built-in NAC synchronization. Built-in programmer. Annunciator bus supports up to 8devices, including ANN-80 LCDRemote Annunciator, remote serialor parallel printer gateway,and LED graphic annunciator. 6-zone Style B (Class B)or 6-zone Style D (Class A)with optional modules. 4 Programmable OutputvCircuitsStyle Y (Class B). Outputs programmablefor Releasing Solenoids. Dual hazard operation. Adjustable pre-discharge,discharge, and waterflowdelay timers. Programmable Abort operation. Cross-zone capability. Pre-programmed and customapplication templates. Built-in NAC synchronization. Built-in programmer. Annunciator bus supports up to 8devices, including ANN-80 LCDRemote Annunciator, remote serialor parallel printer gateway,and LED graphic annunciator.7

Remote Power SuppliesPull StationsThe FL-PS6 is a 6 amp and the FL-PS10 is a 10 amp, remote power supplywith battery charger that may be connected to any 12 or 24 volt fire alarmcontrol panel (FACP) or used as a standalone power supply. The PS Seriesprovides 24 VDC power for NACs (notification appliance circuits) configuredas either Class B or Class A (requires the ZNAC-PS optional card) withmultiple sync protocol options.FL-PS6FL-PS10 12 or 24 volt, 6 or 10 ampversions available. 4 Class B (Style Y)Class A (Style Z) outputs. Built-in Strobe Synchronizationfor ADA Compliance. Built-in 18 amp HourBattery Charger. Operates as a sync followeror a sync generator (default).BG-12 SeriesThe BG-12 is a cost-effective, noncoded series of fire alarm pull stations.They are available in both conventionaland addressable versions, includingsingle and dual action, with eitherkey lock or hex key. The BG-12 seriesis typically specified and is a go-tofor most architects and engineers.BG-8The BG-8 is a conventional, single-actionmetal fire alarm pullstation for jurisdictionswhere metal pull stations are required.Annunciators8ANN-80 and ANN-100ANN-LEDANN-I/OThe ANN-80/100 are compact,backlit 80-character LCD fireannunciators. Both mimic the FACPdisplay and provide system statusindicators for AC, power, alarm,trouble, supervisory and alarmsilence conditions. ANN-100is FM and ULC approved.The ANN-LED annunciator moduleprovides LED annunciation of generalsystem faults, and input zones andpoints when used with a compatibleFACP. It provides alarm, trouble,and supervisory indication for upto 10 input zones or addressablepoints.The ANN-I/O is a LED drivermodule that can be used witha FACP to drive most customizedgraphic annunciators. It comesin a plastic enclosure that maybe mounted inside a customannunciator or accessory cabinet,and can drive up to 40 LEDs.

Addressable Smoke DetectionH365SD365SD365COFire-Lite is always at the forefront of future detection coderequirements. Our new line of addressable detectors, bases,and accessories maintain the same performance offered byprevious core devices, now with a more modern look.SWIFT – Smart WirelessIntegrated Fire TechnologyLTE Commercial FireAlarm CommunicatorsHW-TG7L SeriesCLSS LTE FireCommunicatorsCommunicator Features Verizon (HW-TG7LVF02) and AT&T(HW-TG7LAF02) models available Manufactured by Telguard ; designed forcompatibility with Honeywell Connected LifeSafety Services (CLSS) Provides sole, primary, or backup pathcommunication Supports most common alarm formats,including Contact IDSoftware Features CLSS Site Manager provides dealers witha “bird’s eye” view of all accounts and real-timeevent information CLSS Facility Manager provides end users withaccess to inspection reports and event alertsSWIFT wireless addressable devices provide secure communicationto the FACP across a Class A mesh network. SWIFT technologycan be used in parallel with wired systems, allowing wirelessdevices to be added alongside wired devices on the same system.SWIFT GatewayUsing the W-GATE gateway, the FACP views SWIFT wirelessdevices as additional addressable devices on the system, providingsimilar detection functions and outputs as a wired counterpart.SWIFT DevicesThe SWIFT line offers a variety of device options including photoelectric, photo/thermal, fixed heat, and rate-of-rise heat detectors,pull stations, AV bases, and relay, monitor and sync modules.SWIFT ToolsEmploy a wireless transmitter (W-USB) to aid in the site survey,mesh formation, and diagnostics of the system.HWF2-COM Series LTE FireCommunicatorsThe HWF2V-COM (Verizon) and HWF2A-COM (AT&T)LTE fire alarm communicators represent a leadingedge internet and/or LTE cellular communicationssolution for monitoring fire alarm systems and easily install using AlarmNet. Fast, secure, and effectivealarm communications technology enables connection to any Contact-ID fire panel.9

ES-50XFire AlarmControl PanelExample of a Complete Fire Alarm SystemECC-50/100Primary Enabled LTE FireCommunicatorECC-FFTFire Fighter TelephoneECC-50DAECC-50BDAECC-125DADistributed AudioAmplifiersANN-80AnnunciatorECC-LOCLocal OperatorConsoleSD365Photo D365COMulti-criteriaDetectorECC-RMRemote MicrophoneECC-RPURemote Paging UnitP2RL StrobeH365H365RH365THeat DetectorMDF-300Dual MonitorModuleP2RL-LFLow FrequencyNotification DevicesPower 300Monitor ModuleMulti-Modules CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit SupervisedControl Module MMF-302-6 Six-Zone Interface Module MMF-300-10 Ten Input Monitor Module ISO-6 Six Output Isolator ModuleHWL-LFSWIFT Wireless Mesh NetworkW-GATEWirelessGatewayW-SD355WirelessPhoto DetectorW-H355WirelessHeat DetectorSLMMF-3022-Wire DetectorMonitor ModuleWAV-CRL with SCRLWirelessAV Base and StrobeCLoopW-MMFWirelessMonitor ModuleOSI-RI-FLBeam DetectorD355PLDuct DetectorBG-12LXPull Station10W-SYNCWirelessSync ModuleW-BG12LXWirelessPull StationCDRM-300Dual Relay/MonitorModule

Quick Reference GuideConventional Fire Alarm Control PanelsFeaturesMS-2MS-4MS-5UDMS-10UDAddressable Fire Alarm Control PanelsES-50XES-200XMS-9600UDLSPanel Voltage24242424242424Addressable PointsN/AN/AN/AN/A50198636 (2 Loops)LiteSpeed ProtocolN/AN/AN/AN/AYesYesYesNumber of Zones2451050100100Class A/B Initiating Zones/LoopsB OnlyB or A OptionB or A OptionB or A OptionA or BA or BA or BSupports System Sensor i3Detectors with Freeze WarningYesYesYesYesN/AN/AN/ANotification Circuits124 (A or B)4 (A or B)2 (A or B)4 (A or B)4 (A or B)Notification Power (Amps)3.03.0-6.03.07.02.53.0-6.07.0Communicator411 Series411 orts Upload/DownloadNoNoRemote or LocalRemote or LocalRemote or LocalRemote or LocalRemote or LocalWorks with IP ery Range (in Amp 18.07.0-26.0Alarm rogrammableProgrammableTrouble rvisory ogrammableProgrammableReverse Polarity ionTemporal ogrammableProgrammableOptional Remote AnnunciatorNoYesYesYesYesYesYesBuilt-in Sync-Selective SilenceYesYesYesYesYesYesYesSupports PrinterNoNoOptionOptionOptionOptionYesListingsUL, CSFM,MEAUL, CSFM,MEAUL, CSFM,MEA, FMUL, CSFM,MEA, FMUL, CSFM,MEA, FMUL, CSFM,MEA, FMCSFM,MEA, FMDigital Alarm Communicator TransmittersReleasing Control -2002Input DC Voltage12/2412/241212/242424Number of Zones/Channels344Addressable66Class A or Class B ZonesBBB (One A)N/AB or A OptionB or A OptionControl CommunicatorSlaveComm.SlaveComm.Stand-Aloneor Slave Comm.Slave Comm.Contact ID OnlyNoNoRemote Upload/DownloadNoYesYesYesNoNoSupports System Sensor i3Detectors with Freeze WarningN/AN/AN/AN/AYesYesNotification CircuitsN/AN/AN/AN/A44Notification Power (Amps)N/AN/A1N/A77Battery Range (in Amp Hours)N/AN/AUp to 14.0N/A7.0-26.07.0-26.0Auxiliary InputNoNoNoYesN/AN/AAlarm ContactNoOption (Prog.)Option (Prog.)NoProgrammableProgrammableTrouble ContactNoOption (Prog.)Option (Prog.)NoProgrammableProgrammableSupervisory Contact/OutputNoOption (Prog.)Option (Prog.)YesProgrammableProgrammableOptional Remote AnnunciatorNoNoNoNoYesYesSupports PrinterNoNoNoNoYesYesListingsUL, ULC,CSFM, MEAUL, ULC,CSFM, MEAUL, ULC,CSFM, MEAUL, CSFMUL, CSFM,MEA, FMUL, CSFM,MEA, FM11

For more information visit:firelite.comContact our sales team:firelite.com/SalesMapFire-Lite Alarms1 Fire-Lite Place, Northford, CT 06472USA - Phone: (203) 484-7161 www.firelite.com12FL BR ProductCatalog Rev 04 12/2020 2020 Honeywell International, Inc.

Fire-Lite Alarms has a legacy of simple, reliable life-safety systems. By designing advanced technology that’s also easy to use, Fire-Lite makes protecting what matters most easy – year after year. In a world where anything can change in an instant, you can count on the consistency of Fire-Lite. Fire-Lite - Innovation that Endures.

Related Documents:

French doors bring more options for interior spaces. CraftMaster offers clear pine or primed available in 1-Lite, 5-Lite, 6-Lite, 10-Lite, 12-Lite, 15-Lite and 18-Lite doors. CraftMaster offers a complete selection of interior doors to fit any home

CNC software 4.4 SINAMICS S120 4.4 09/2011 6FC5398-6BP40-2BA0 Preface Introduction 1 NCK alarms 2 Cycle alarms 3 HMI alarms 4 SINAMICS alarms 5 Drive and I/O alarms 6 PLC a

7 STEP BOSS / LITE ONE MONTH ROTATION WEEK 1 WORKOUT Monday Step Boss IMAX4 Step Boss Bonus Abs 2 Tuesday LITE PHA 2 Wednesday Step Boss Step Sync Thursday LITE Metabolic Blast Friday LITE Rev'd Up Rumble LITE Bonus Six Pack Abs #1 Saturday Step Boss PHA3 Sunday OFF or Step Boss Bonus Extended Chair Stretch WEEK 2 WORKOUT Monday LITE Cardio Party -

CounterPath X-Lite 3.0 4 Auto Update Upon startup, X-Lite will check for updates and—if found—will prompt users for authorization to install them. Uninstalling X-Lite Uninstall X-Lite like any other program: launch the Windows Control Panel from the Start menu, then select Add or Remove Programs. Follow the prompts. 2.3 Configuring X-Lite 1.

NetSuite WMS Lite Version Notes 1 NetSuite WMS Lite Version Notes The information and procedures in this guide are specific to NetSuite WMS Lite Version 16.1. For Version 15.2 information and procedures, see the NetSuite WMS Lite User Guide — Version 15.2. This section summarizes the changes to NetSuite WMS Lite between the noted version and the

Alarm Fatigue Too many alarms lead to people ignoring alarms and potentially dangerous situations Graded Alarms Alarm information is coded in multiple ways: –Alphanumeric data –Color coding –Differential auditory alarms Machines grade alarms by the severity of the proble

Jun 12, 2018 · 15. The main ScaleLink Pro 5 Lite application opens. Figure 11. ScaleLink Pro 5 Lite Startup Screen If a firewall is installed on your PC, the firewall software may display popup windows when ScaleLink Pro 5 Lite is first run asking whether to allow ScaleLink Pro 5 Lite to have access to the network; always permit access.

An Alphabetical List of Diocesan and Religious Priests of the United States REPORTED TO THE PUBLISHERS FOR THIS ISSUE (Cardinals, Archbishops, Bishops, Archabbots and Abbots are listed in previous section)