Foxfire Pellet Stove

2y ago
5 Views
2 Downloads
5.52 MB
52 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Mariam Herr
Transcription

FoxfirePellet Stove Horizontal or Vertical Vent Freestanding Stove Mobile Home Approved Class A Chimney Retrofit Hearth Stove into ExistingMasonry Chimney , MasonryFireplace, or Z.C. Fireplace-- Please read this entire manual beforeinstallation and use of this pellet fuelburning room heater. Failure to followthese instructions could result inproperty damage, bodily injury, or evendeath.Tested and Listed by:ASTM E1509-12 ULC-S627-- Contact local building or fire officialsabout restrictions and installationinspection requirements in your area.-- Save these instructions.Installer: After installation give this manual to the homeowner and explain operation of this heater.Consumer: Retain this manual for future reference. 10.00 Copyright 2018, T.I.Part # 100-014022/18/19www.travisproducts.com12521 Harbour Reach Drive SWMukilteo, WA 98275

Introduction2IntroductionWe welcome you as a new owner of a Foxfire pellet stove. In purchasing an pellet stove you havejoined the growing ranks of concerned individuals whose selection of an energy system reflects botha concern for the environment and aesthetics. The Foxfire pellet stove is one of the finest homeheaters the world over. This manual will explain the installation, operation, and maintenance of thispellet-burning heater. Please familiarize yourself with this Owner's Manual before operating yourheater and save the manual for future reference. Included are helpful hints and suggestions whichwill make the installation and operation of your new heater an easier and more enjoyable experience.We offer our continual support and guidance to help you achieve the maximum benefit and enjoymentfrom your heater.Important InformationNo other Foxfire pellet stove has the same serialnumber as yours. The serial number is on the safetylabel on the back of the appliance.Register your warranty online at:This serial number will be needed in case you requireservice of any type.Save Your Bill of Sale.Model:Serial Number:Purchase Date:Foxfiretraviswarranty.comTo receive full warranty coverage, you will need toshow evidence of the date you purchased yourheater.We suggest that you attach your Bill of Sale to thispage so that you will have all the information youneed in one place should the need for service orinformation occur.Purchased From: Travis Industries2/18/19 - 1402Foxfire Stove

Table of ContentsIntroduction . 2Important Information . 2Heating Specifications . 7Dimensions . 7Electrical Specifications . 7Fuel. 7Emissions . 7Efficiency . 7Before You Begin . 8Packing List . 8Installation Options. 8Planning the Installation . 9Stove Placement . 9Floor Protection Requirements. 9Electrical Requirements . 9Clearances . 10Straight Installations . 10Corner Installations . 10Venting the Pellet Stove . 11Maximum Venting Distance . 11Pellet Vent Type. 12Installing the Pellet Vent . 12Pellet Vent Termination . 12Mobile Home Requirements . 13Outside Air Requirements (Used for Combustion Part #99200139). 13Alcove Installation Requirements. 14Restrictor Adjustment . 14External Thermostat Installation . 15Installation Examples . 16Installation Example: Direct "Through-the-wall"Installation . 16Installation Example: Interior Vertical Installation 17Class A Chimney Retrofit . 18Installation Example: Masonry Fireplace HearthStove . 19Installation Example: Zero-Clearance (Metal)Fireplace Hearth Stove . 20 Travis Industries3Installation Example: Freestanding MasonryChimney . 21Safety Notice . 22Touch Screen Controls . 22Loading Pellets. 23Starting the Heater for the First Time . 23Curing the Paint . 23Modes of Operation – Manual or Thermostat . 24Manual Mode . 24Thermostat Mode . 24Manual Mode . 25To Start . 25To Shut Down . 25Adjusting the Heat Setting. 25Thermostat (T-stat) Mode . 26Fan Setting . 28Manual Adjustments . 28Auto-Fan . 28Heater Status . 29Standby . 29Start-Up. 29Heating . 29Cool-Down . 29Fault . 29Menu Button . 30T-Stat Temperature . 30T-Stat Source . 30T-Stat Program . 30Screen Lock . 30Power Outages . 31Manual Mode . 31TSTAT Mode . 31Normal Operating Sounds . 31Stove Maintenance. 32Replacement Parts . 47Door Parts . 47Wiring Diagram. 482/18/19 - 1402Foxfire Stove

Safety Precautions4HOT WHILE IN OPERATION.KEEP CHILDREN, CLOTHING,AND FURNITURE AWAY.CONTACT MAY CAUSE SKINBURNS.Educate all children of the danger ofa high-temperature heater. Youngchildren should be supervised whenthey are in the same room as theheater.Contact your local building officialsto obtain a permit and informationon any installation restrictions orinspection requirements in yourarea. Notify your insurancecompany of this appliance as well.Do not operate the heater if yousmell smoke coming from theheater. Press the “STOP” button,monitor your heater, and call yourdealer.Never use gasoline, gasoline-typelantern fuel, kerosene, charcoallighter fluid, or similar liquids to startor “freshen up” a fire in this heater.Keep all such liquids well away fromthe heater while it is in use.Do not store solid fuel or place suchfuel within heater installationclearances or within the spacerequired for charging and ashremoval.Do not unplug the heater if yoususpect a malfunction. Press the“STOP” button and periodicallyinspect the heater.Do not alter this appliance in anyway. Travis IndustriesAshes should be placed in a metalcontainer with a tight-fitting lid. Theclosed container of ashes should beplaced on a noncombustible floor oron the ground, well away from allcombustible materials, pending finaldisposal. If the ashes are disposed ofby burial in soil or otherwise locallydispersed, they should be retained inthe closed container until all cindershave been thoroughly cooled.Never try to repair or replace anypart of the heater unlessinstructions are given in thismanual. All other work should bedone by a trained technician.The viewing door and ashpan mustbe closed and latched duringoperation.This unit must be properly installedto prevent the possibility of a housefire. The instructions must be strictlyadhered to. Do not use makeshiftmethods or compromise in theinstallation.This heater is designed and approvedfor pelletized wood fuel only.2/18/19 - 1402Foxfire Stove

Safety PrecautionsAllow the appliance to coolcompletely before carrying out anymaintenance or cleaning.5Maintain the door and glass sealand keep them in good condition.Do not operate this heater withbroken or missing glass.Do not slam the door or strike theglass.Notify your dealer to replace theglass if glass on this appliance isbroken or damaged. Travis IndustriesDo not operate the heater if theflame becomes dark and sooty or ifthe burn platform overfills withpellets. Press the “STOP” buttonand periodically inspect the heater.Do not place clothing or otherflammable items on or near thisappliance.The heater will not operate during apower outage.This heater must be connected to astandard115 V., 60 Hz groundedelectrical outlet. Do not use anadapter plug or sever the groundingplug. Do not route the electrical cordunderneath, in front of, or over theheater.Keep foreign objects out of thehopper.The exhaust system must becompletely airtight and properlyinstalled. The pellet vent joints mustbe sealed with RTV 500 F. (260 C.)silicone sealant.Your heater requires periodicmaintenance and cleaning (see"Heater Maintenance"). Failure tomaintain your heater may lead toaccumulation of soot, creosote, andash, and smoke spillage or fire inyour home.When installed in a mobile home,the heater must be bolted to thefloor, have outside air, and NOT BEINSTALLED IN THE BEDROOM(per H.U.D. requirements). Checkwith local building officials.2/18/19 - 1402Foxfire Stove

Safety Precautions6Do not throw this manual away.This manual has importantoperating and maintenanceinstructions that you will need at alater time. Always follow theinstructions in this manual.Disconnect the power beforeperforming any maintenance.The exhaust system should bechecked at least twice a year forany build-up of soot or creosote.Travis Industries, Inc. grants nowarranty, implied or stated, forthe installation or maintenance ofyour appliance, and assumes noresponsibility of anyconsequential damage(s).DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.Soot and Flyash: Formation and Need for Removal – The products of combustion will containsmall particle of flyash. The flyash will collect in the exhaust venting system and restrict theflow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, orincorrect operation of the room heater will lead to some soot formation which will collect inthe exhaust venting system. The exhaust venting system should be inspected at least twiceevery year to determine if cleaning is necessary.NEVER USE SUBSTITUTE MATERIALS FOR ANY PURPOSE ON THIS APPLIANCE.Establish a routine for fuel and firing technique. Check for creosote build-up daily until youknow how often to clean the appliance for safe operation. Be aware that the hotter the fire, theless creosote is deposited, and weekly cleaning may be necessary in mild weather eventhough monthly cleaning may be enough in the coldest months. Contact your municipal orprovincial fire authority for information on how to handle a chimney fire. Have a clearlyunderstood plan in place for how to handle a chimney fire.Do not burn this heater if unburned pellets are in the ashpan. These should be removed as theymay ignite.Smoke and CO Detectors: Make sure your home has a working smoke detector, especially near any bedrooms. Werecommend having a smoke and/or CO detector in the same room as the wood heater for additional safety.Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels,contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.California Health & Safety Code Sec. 25249.6This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations toalter this setting otherwise operate this wood heater in a manor inconsistent with operating instructions in this Manual.U.S. and Foreign Patents Pending. Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)7Heating SpecificationsApproximate Maximum Heating Capacity (in square feet)* . Up to 2,500 Sq. FeetBTUs Per Hour. 13,940 to 49,200 **Burn Rate (Pounds per Hour)*** . 1.7 to 6Maximum Burn Time on Low Burn*** . 47 HoursHopper Capacity . 80 PoundsTurn-Down Ratio . 67%*Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It isalso affected by the fuel size, quality, and moisture level.**Based on 8,200 BTUs per pound***Small pellet size will decrease the stated burn rates and burn times. Differences of plus or minus 20% depending onfuel quality may occur.DimensionsElectrical SpecificationsElectrical Rating . 115 Volts, 4 Amps, 60 HzWatts during Start-Up Sequence . 480 (approximately)Watts during Operation . 300 (approximately)FuelThis heater is designed and approved for pelletized wood fuel only (all grades). Travis Industries Inc.recommends using only fuel that is certified by the Pellet Fuels Institute (PFI).EmissionsThis heater meets the 2020 U.S. EPA’s emission limits for pellet stoves.Report# 0028PS120ETested to ASTM E2779-10, ASTM2515, CSAB415.1-10 this heater has been shown to deliver heat atrates ranging from 15,868 to 47,604 BTU/hr and an emission value of 0.90g/h.EfficiencyThis model was tested for efficiency using method B415.1-10and was determined to have a weightedaverageHigher heating value (HHV) Overall Heating Efficiency (OHE) of 72%. Overall efficiency of the heater maybe lower if the heater is operated with the heat exchange blower on low. Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)8Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TOFOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVENDEATH.Check with local building officials for any permits required for installation of this pellet heater andnotify your insurance company before proceeding with installation.Packing ListCleaning toolBottle BrushBurn PlatformWedgeBrush5 AmpFusesInstallation Options Residential or Mobile Home (see the section "Mobile Home Requirements")Alcove Compatible (see the section "Alcove Installation")Horizontal or Vertical VentVent with L-Vent, L-Vent Fireplace Liner, or Type “A” Chimney (with adapter) Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)9Planning the InstallationHINT:Have an authorized Travis Industries dealer install this heater. If you install theheater yourself, have your dealer review your installation plans.HINT:Sketch out a detailed plan of the installation including dimensions. Then verify thedimensions with the requirements listed in this manual.HINT:When determining the location of the stove, locate the wall studs (for horizontalpenetrations) and ceiling trusses (for vertical penetrations). You may wish to adjustthe stove position slightly to ensure the vent does not intersect with a framingmember.The location of your wood heater in your home will decide how effectively the heat produced willspread throughout your house. Attention to the home design with consideration of natural convectionand air circulation should be taken into account when choosing the placement of your heater withinthe home.Stove Placement Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes,doors), 36" (915mm) of the front of the heater.If the stove is placed in a location where the ceiling height is less than 7' (2.134 M), it must followthe requirements in the section "Alcove Installation Requirements".Heater and floor protection must be installed on a level, secure floor.Floor Protection Requirements The heater must be installed on a non-combustible floor protector extending the full width anddepth of the heater and extending 6" (153mm) in front (minimum .018" thick - 26 gauge).Must extend under and 2" (51mm) to each side and rear of a "Tee" (if used).Electrical Requirements This heater requires a standard 120 volt, 60 Hz grounded electrical outlet. Do not use anadapter plug or sever the grounding plug. This heater requires correct polarity. The line (hot) is on the right and has a smaller plug. Theneutral (common) is on the left and has a larger plug. Use a circuit tester (available at hardwarestores) or contact an electrician to verify correct polarity and ground.WARNING: Connection to a reverse polarity or un-grounded circuit may damage your heater’scircuit board. This may cause a safety hazard, improper operation, and void your warranty. Do not route the electrical cord underneath, in front of, or over the heater. Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)10ClearancesStraight InstallationsCorner Installations***Install the vent at the clearance specified by the vent manufacturer.NOTE: If an interior vertical vent is used, the stove to backwall dimension is determined by thevent being used. This dimension will vary depending on the brand of pellet vent used. Todetermine the distance from the backwall to the stove, connect the "Tee" and add the ventclearance.The floor protection must extend 2” (51mm) beyond the pipe – all vent clearances must be met. Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)11Venting the Pellet Stove INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE ORSTOVE.DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS ANDA CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGHCEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).No more than one tee and 180 of elbows (one tee with two 90 elbows, one tee with one 90 andtwo 45 elbows, etc.).Maximum Venting Distance Vent must have a support bracketevery 5' (1.524 M) of pellet vent whenon exterior of structure.NOTE: Travis Industriesrecommends a minimum vertical ventof 5’ to ensure adequate draft duringa power outage.The vent height andrun must not exceedthe distance shown inthe shaded regionindicated to the rightRestrictor adjustmentmay be requireddependent on the ventconfiguration. See thesection “RestrictorAdjustments” fordetails.Note: To achieveoptimum performance,we recommendkeeping the vent asshort as possible(horizontal runespecially). Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)12Pellet Vent Type Must be 3" (76mm) or 4” (102mm) diameter Type "L" (except for masonry fireplace installations) or - connect the vent to a factory built type "A" chimney.Installing the Pellet Vent Secure each vent section (including the connection to the heater, adapters, elbows, etc )following the directions provided by the vent manufacturer or by using 3 sheet metal screws (1/4”Max.).Horizontal sections must have a 1/4" (6.4mm) rise every 12" (305mm) of travel.Install the vent at the clearances specified by the vent manufacturer.Pellet Vent Termination Vent must terminate on the exterior of the dwelling. Horizontal terminations must protrude aminimum of 12" (305mm) from the wall. Vertical terminations must protrude a minimum 24"(610mm) from the roof surface. In addition, all clearances listed below must be met.Must have an approved cap (to prevent water from entering) or a 45 downturn with rodentscreen.If the termination is located on a windy side of the house, an approved house shield isrecommended to prevent soot from building up on the side of the house.Must not be located where it will become plugged by snow or other material.ABCDEFGHXMinimum 4' (1220mm) clearance below or beside any door or window that opens.(This clearance may be reduced to18” if using outside air (see page 13) – we recommendthe door or window be kept closed during operation.Minimum 1’ (458mm) clearance below or beside any window that does not open.Minimum 1' (458mm) clearance above any door or window that opensMinimum 2' (610mm) clearance from any adjacent buildingMinimum 7' (2.134 M) clearance above any grade when adjacent to public walkwaysNOTE: Vent may not terminate in covered walkway or breezeway.Minimum 2' (610mm) clearance above any grass, plants, or other combustible materialsMinimum 3' (915mm) clearance from any forced air intake of any other applianceMinimum 2' (610mm) clearance below eaves or overhangsMinimum 1' (458mm) clearance horizontally from combustible wallMust be a minimum of 2' (610mm) above the roof Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)13Mobile Home Requirements Outside air is required (used for combustion) - see the directions below.The heater must be bolted to the floor (Some states do not require this; check with your local buildingdepartment).The heater must be grounded to the steel chassis of the mobile home (Some states do not require this;check with your local building department).DO NOT INSTALL IN SLEEPING ROOM.CAUTION:THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, ANDCEILING/ROOF MUST BE MAINTAINED.Outside Air Requirements (Used for Combustion Part #99200139) Outside air is required. This reduces noise levels inside the house and prevent smoke spillageduring power outages.Must not be drawn from an enclosed space (garage, unventilated crawl space).Must not be over 48” (1220mm) longMust be made with 3” (76mm) diameter or larger metal or aluminum duct with a metal screenattached to the end to keep out rodents (P.V.C. or other combustible materials may not be used).We recommend the Travis Industries Outside Air Kit (part # 99200139).Must not terminate above or within 1' (305mm) of the chimney termination.Must have a rain cap or down-turned elbow to prevent water from entering.Must be located so that it will not become plugged by snow or other material.A screen is required to preventrodents from entering.3" Air DuctAir may be drawn from a ventilated crawl space.Outside air entrance must be placed so itdoes not become blocked by snow. Travis Industries2/18/19 - 1402Foxfire Stove

14Installation (For Qualified Installers Only)Alcove Installation RequirementsWhen the pellet stove is placed in a location where the ceiling height is less than 7' (2.134 M) tall, it isconsidered an alcove installation. Because of the reduced height, the requirements listed below must bemet.37-1/2“Minimum Width48”Maximum Depth60“Minimum HeightRestrictor AdjustmentFor installations with a tall flue, the restrictor may be needed to adjust airflow to the burn platform. Thiskeeps the burn platform and glass as clean as possible.For low heat output settings the restrictor may need to be closed or near closed to limit the amount ofair. This helps prevents the heater from burning the pellet fuel faster than it is fed.For medium heat output settings the restrictor may need to be opened to a medium position.For high heat output settings the restrictor may need to be opened to a high position. This helpsprevent the burn platform from over-filling with pellets and becoming clogged with ash clumps.Keeping your burn platform clean is the most important step to maintaining a safe and efficient heater.Check and clean your burn platform daily until you find the correct restrictor settings and appropriate burnplatform cleaning interval.Not Enough AirIf clinkers (ashes that solidify into a clump)develop or the flame appears lazy and slowto blow the ash out of the burn platform,push the restrictor in until the flamebecomes active and the burn platformholes remain clean.NOTE: If the restrictor is fully in, yet theburn platform does not remain clean, theheater should be cleaned and checked forair leaks (see “Maintenance” section of thismanual).Too Much AirIf the flames are too active (small, flickeringflames), move the restrictor rod out untilthe flame slows down.NOTE: It is acceptable to have “glowingembers” jump out of the burn platform.Another symptom of too much air is theheater “blowing the fire out” – a condition inwhich the pellets burn faster than they arefed (this is most common on low heatsettings). Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)15External Thermostat Installation This heater may be used with an external thermostat or remote.WARNING: Use only a dry-contact thermostat or remote (also called millivolt thermostat/remote).Use of a voltage producing thermostat (24v, 120v AC, etc.) will damage the appliance. Connect the leads from the thermostat to the two quick-connect tabs on the back of the heater.Once the external thermostat is installed, you will need to configure the heater to disable theinternal thermostat. See the instructions on page 26. Travis Industries2/18/19 - 1402Foxfire Stove

16Installation (For Qualified Installers Only)Installation ExamplesInstallation Example: Direct "Through-the-wall" InstallationNOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during apower outage.Install the vent at the clearance specified by the vent manufacturer. Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)17Installation Example: Interior Vertical Installation* Travis IndustriesInstall vent at clearance specified by the vent manufacturer.2/18/19 - 1402Foxfire Stove

18Installation (For Qualified Installers Only)Class A Chimney Retrofit* Travis IndustriesInstall vent at clearance specified by the vent manufacturer.2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)19Installation Example: Masonry Fireplace Hearth Stove Travis Industries2/18/19 - 1402Foxfire Stove

20Installation (For Qualified Installers Only)Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove Travis Industries2/18/19 - 1402Foxfire Stove

Installation (For Qualified Installers Only)21Installation Example: Freestanding Masonry Chimney* Travis IndustriesInstall vent at clearance specified by the vent manufacturer.2/18/19 - 1402Foxfire Stove

Operation22Safety NoticeREAD THIS ENTIRE MANUAL (ESPECIALLY THE "SAFETY PRECAUTIONS" ON PAGES 4 AND5) BEFORE USING THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULTIN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.DO NOT UNPLUG THE HEATER TO TURN IT OFF. THIS HEATER RELIES UPONELECTRICITY TO PUSH THE FLUE GASES OUT THE PELLET VENT – UNPLUGGING ITMAY LEAD TO SMOKE ENTERING YOUR ROOM.FAILURE TO MAINTAIN YOUR HEATER WILL LEAD TO A RESTRICTED COMBUSTION AIRSYSTEM, LEADING TO POOR PERFORMANCE AND IN SOME CASES, SMOKE SPILLAGEINTO THE ROOM. SEE THE "MAINTENANCE" SECTION FOR DETAILS.DO NOT USE CHEMICALS OR FLAMMABLE FLUIDS TO START THIS HEATER.Touch Screen ControlsThe touch screen is located on the hopper lid.Fan Setting SliderT-stat 72Room Temperature 68 Digital DisplayHeat Setting SliderOn/Off ButtonThermostat ButtonMenu Button Travis Industries2/18/19 - 1402Auto-Fan ButtonFoxfire Stove

Operation23Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper.NOTE:If the hopper lid is opened for more than 1 minute, the heater will enter shut downcycle. If this happens, simply restart the heater.WARNING: The heater top becomes hot during operation. Make sure to keep any flammable items(bag of pellet

installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. -- Contact local building or fire officials about restrictio

Related Documents:

Santa Fe Pellet Stove R R R 1 Listing and Code Approvals Model: Santa Fe Pellet Stove Laboratory: OMNI Test Laboratories, Inc. Report No. 061-S-53-2 Type: Solid Fuel Room Heater/Pellet Type Standard: ASTM E1509 and ULC/ORD-C1482 Room Heater Pellet Fuel Burning type and (UM) 84-HUD, Mobile Home Approved. A. Appliance Certification C. Glass .

electricity for ignition and stove operation is a disadvantage of pellet stoves especially with regard to fail-proof and independent heating systems. In order to enable the operation of a pellet stove without electric grid connection, a new micro CHP technology for a pellet stove based on a thermoelectric generator has been developed. 3

When first operating the pellet stove, switch it to manual mode, so you can have full control of the pellet stoves control board functions and familiarize yourself with how the pellet stove works. It is in this mode that the heat level for the AUTO and T-STAT mode is set. To Start up a Cold Stove Press and release the On/Off button.File Size: 930KB

of burning pellet fuel. PELLETS This pellet stove is designed and approved to burn wood pellets, that comply with pellet fuels industry standards. Minimum of 40 lbs. density per cubic feet, 1/4 to 5/16 in diameter, with a maximum length of 1-1/2, and less than 1% ash. Pellet fuel

Paladin pellet mill Paladin 600 Paladin 1600 02. 03 Paladin 1600 ES Paladin 2000 Paladin 3000 Paladin pellet mill series. Features that make the difference 1 3 2 . Paladin pellet mill, Paladin, andritz pellet mill, feed pelleting, pelleting, pelletizer, andritz pellet Created Date:

OWNER’S MANUAL Freestanding and Fireplace Insert . Insert: The rating label is located on the hopper cover. PeLLet QuaLity: Pellet quality is important, please read the following: Your Hudson River pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel

Nov 02, 2005 · SANTA FE PELLET STOVE Owner’s Manual Installation and Operation SANTAFE-B1 . Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home . ASTM E1509, ORD-C-1482-M199 0 Room Heating Pellet Burning Type, APFI, (UM) 84-HUD FOR USE ONLYWITHPELLETIZED WOOD

this pellet fuel burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. . FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel