1719 Ex I/O - Rockwell Automation

3y ago
128 Views
3 Downloads
2.41 MB
30 Pages
Last View : 23d ago
Last Download : 3m ago
Upload by : Kelvin Chao
Transcription

Technical DataOriginal Instructions1719 Ex I/OCommunication Adapter Catalog Number 1719-AENTRI/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IBN8, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4HPower Supply Catalog Number 1719-PSDCBackplane Catalog Numbers 1719-A22, 1719-A8, 1719-A24Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2SA, 1719-TB8x2, 1719-TB6F, 1719TB8F, 1719-TB8x2FConnection Cable Catalog Number 1719-CBLPlaceholder Module Catalog Number 1719-ARMSeparation Plate Catalog Number 1719-SP1TopicSummary of Changes1719 Ex I/O Communication Adapter1719 Ex I/O Digital Input1719 Ex I/O Analog Input/Output1719 Ex I/O Digital Output1719 Ex I/O Power Supply1719 Ex I/O Backplane1719 Ex I/O Terminal Blocks1719 Ex I/O Connection Cable1719 Ex I/O Placeholder1719 Ex I/O Separation PlatePage2581720222425262727

Summary of ChangesThis publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflectall changes.TopicAdded Separation Plate specifications2Page27Rockwell Automation Publication 1719-TD001G-EN-E - November 2020

1719 Ex I/O Products1719 Ex I/O ProductsCommunication AdapterType1719-AENTRFunctionFeaturesThe EtherNet/IP adapter forms the interface between the I/ Communication via EtherNet/IPO modules on the backplane and the process control system. HART communication via EtherNet/IP Interface between the I/O modules and the PCS/PLCIt supports all single width and dual width I/O modules.Thereby signals from NAMUR sensors, mechanical contacts, Installation in Zone 2 or Class I, Div. 2, or safe area Nonvolatile memory for configuration and parameter settingshigh-power solenoid drivers, power relays, sounders, andalarm LEDs are transported to the higher-level bus system. Permanently self-monitoringThe adapter supports HART. Permits vertical or horizontal mounting in Zone 2(1)(1) If you mount the backplane vertically, position the power supplies at the top to achieve a favorable heat distribution.Digital Input res 1-channel (1719-IJ); 8-channel (1719-IBN8B, 1719-IBN8) Input Ex ia Input for frequency, counter, direction of rotation (1719-IJ)The device accepts digital input signals of NAMUR sensors or Digital input max 15 kHz (1719-IJ)mechanical contacts from the hazardous area. Dry contact or NAMUR inputs (1719-IBN8B, 1719-IBN8)Open and short-circuit line faults are detected. Installation in Zone 2 or Class I, Div. 2, or safe areaThe intrinsically safe inputs are galvanically isolated from Line fault detection (LFD)the bus and the power supply. Permanently self-monitoring Permits vertical or horizontal mounting in Zone 2(1) Module can be exchanged under voltage when the area is nonhazardousAnalog Input ModulesTypeAnalog he transmitter power supply feeds 2-wire transmitters.Active signals from separately powered field devices and 4wire transmitters can be connected.Open and short-circuit line faults are detected.The intrinsically safe inputs are galvanically isolated fromthe bus and the power supply.The RTD converter accepts 2-, 3-, 4-wire RTD signals (Pt100.Pt1000) and slide-wire sensors from the field. Ni100 throughNi1000 can also be connected.Open and short-circuit line faults are detected.The intrinsically safe inputs are galvanically isolated fromthe bus and the power supply.The thermocouple converter accepts thermocouple or mVsignals from the field.Open circuit line fault alarms are detected.The intrinsically safe inputs are galvanically isolated fromthe bus and the power supply. There is a functional isolationbetween the channels. 4-channelInputs Ex iaPower supply for 2-wire transmitters with 4 mA.20 mA (1719-IF4HB)Converter for 2-, 3-, and 4-wire RTDs (Pt100.Pt1000), slide wire sensors and so on(1719-IR4B)Converter for thermocouples and mV-signals (1719-IT4B)Supply circuit 15V (20 mA) (1719-IF4HB)Input from active signals of 4-wire transmitters (1719-IF4HB)Installation in Zone 2 or Class I, Div. 2, or safe areaHART communication (1719-IF4HB)Line fault detection (LFD) (1719-IF4HB, 1719-IR4B, 1719-IT4B): one LED per channel(1719-IF4HB)Permanently self-monitoringPermits vertical or horizontal mounting in Zone 2(1)Module can be exchanged under voltage when the area is nonhazardousConfigurable Analog Input/Output ModulesType1719-CF4HFunctionFeatures 4-channel Inputs Ex ia, Outputs Ex iaThe device is a configurable analog input/analog output Installation in Zone 2 or Class I, Div. 2, or safe areamodule. The module can operate in the following modes: Analog input, analog output As an analog input (AI) it feeds 2-wire transmitters. Supply circuit 21.5V (4 mA) As an analog output (AO) it can drive proportional valves, I/ HART communicationP converters, or local indicators. Line fault detection (LFD): one LED per channelThe intrinsically safe signals are galvanically isolated from Permanently self-monitoringthe bus and the power supply. Permits vertical or horizontal mounting in Zone 2(1) Module can be exchanged under voltage when the area is nonhazardousRockwell Automation Publication 1719-TD001G-EN-E - November 20203

1719 Ex I/O ProductsDigital Output ModulesType1719-OB21719-OB2LFunctionThe digital output features two independent channels.The device can be used to drive solenoids, sounders, or LEDs.Open and short-circuit line faults are detected in on and off state.The intrinsically safe outputs are galvanically isolated from the busand the power supply.The output can be switched off via a contact. This can be used forsafety applications.Features Outputs Ex ia Installation in Zone 2 or Class I, Div. 2, or safe area 2-channel Line fault detection (LFD); one LED per channel Positive or negative logic selectable Permanently self-monitoring Output with deactivation feature Can be configured in High Current mode Permits vertical or horizontal mounting in Zone 2(1) Module can be exchanged under voltage when the area is nonhazardousPower Supply ModuleType1719-PSDCFunctionThe power supply provides power for the I/O modules andadapters mounted on the backplane.Power supplies can be connected in parallel to achieveredundancy. Two power supplies may be needed, dependingon the number and power consumption of the modules used.A third power supply then handles redundancy.Input supply and output supply are galvanically isolated fromeach other (EN 61010-1).Features Permits vertical or horizontal mounting in Zone 2(1)Installation in Zone 2 or Class I, Div. 2, or safe areaUse up to three 1719-PSDC power supplies for N 1 redundancyPower supply of I/O modules and adaptersModule can be exchanged under voltage when the area is nonhazardousTerminal TB8x2FFunctionFeatures Side screw terminal (1719-TB6, 1719-TB8, 1719-TB8x2) Front screw terminal (1719-TB6F, 1719-TB8F, 1719-TB8x2F) Spring terminal (1719-TB6S,1719-TB8S, 1719-TB8Sx2,1719-TB8x2SA)Terminal blocks are wired to the field devices, attached to For 1719 modulesthe front sockets of the I/O modules, and tightened using the 6-pole, Labeled 1.6 (1719-TB6, 1719-TB6S, 1719-TB6F)screws. Terminal blocks can come in the form of side screw 8-pole, Labeled 1.8 (1719-TB8, 1719-TB8S, 1719-TB8F)terminals, front screw terminals, or spring terminals. 2 x 8-pole, Labeled 1.8 and 9.16(1719-TB8x2, 1719-TB8Sx2, 1719-TB8x2SA, 1719-TB8x2F) Color blue For Ex ia or Ex ib applicationsConnection CableType1719-CBLFunctionExtension backplanes are delivered with a 1-m-long doubleended cordset. The double-ended cordset establishes theconnection to the base backplane.FeaturesFunctionPlaceholder modules are used to cover empty slots on thebackplane and fix unused field wiring, if needed.This module does not reserve an address.This module can be placed in any sequence on the chassis.Features Connection of base and extension backplanes For 1719 Ex I/OPlaceholderType1719-ARM Placeholder module Blue screw terminal Permits vertical or horizontal mounting in Zone 2(1)Separation PlateType1719-SP14FunctionFeaturesThe separation plate helps ensure that intrinsically safe and Ensures a clearance of 50 mm between intrinsically safe circuits and nonnon-intrinsically safe circuits meet the minimum distance.intrinsically safe circuits, as required by IEC 60079-14 and IEC 60079-11.Rockwell Automation Publication 1719-TD001G-EN-E - November 2020

1719 Ex I/O Products1719 Ex I/O ModulesTypeCatalog NumberCommunication Adapter 1719-AENTR1719-IJDigital Input1719-IBN8B1719-IBN81719-IF4HBAnalog Input1719-IR4B1719-IT4BConfigurable1719-CF4HAnalog Input/Output1719-OB2Digital Output1719-OB2LPower 9-TB61719-TB6S1719-TB81719-TB8S1719-TB8x2Terminal 9-TB8x2FConnection Cable1719-CBLPlaceholder1719-ARMSeparation Plate1719-SP1DescriptionEx I/O EtherNet/IP AdapterEx I/O Frequency CounterEx I/O 8 Point Digital Input NAMUR WideEx I/O 8 point Digital Input NAMUREx I/O 4 Channel HART Analog Input WideEx I/O 4 Channel RTD Input WideEx I/O 4 Channel Thermocouple Input WidePage5Ex I/O 4 Channel HART Analog Configurable17Ex I/O 2 Point Digital Output 23VEx I/O 2 Point Digital Output 16.5VEx I/O DC Power SupplyEx I/O 22 Slot Base ChassisEx I/O 8 Slot Base ChassisEx I/O 24 Slot Extension ChassisEx I/O 6 Pole Screw TerminalEx I/O 6 Pole Spring TerminalEx I/O 8 Pole Screw TerminalEx I/O 8 Pole Spring TerminalEx I/O 2x8 Pole Screw TerminalEx I/O 2x8 Pole Spring TerminalEx I/O 2x8 Pole Spring Terminal for 1719-IBN8Ex I/O 6 Pole Front Screw TerminalEx I/O 8 Pole Front Screw TerminalEx I/O 2x8 Pole Front Screw TerminalEx I/O Chassis Extension Cable 1 mEx I/O Empty Slot CoverEx I/O Separation Plate8912202224252627271719 Ex I/O Communication AdapterCOMµCE the rN e t/IPCOM1719-AENTR Ex I/O EtherNet/IP Adapter - Connectionto I/OZone 2Div. 2Rockwell Automation Publication 1719-TD001G-EN-E - November 20205

1719 Ex I/O ProductsTechnical SpecificationsAttributeSupplyConnectionRated voltage Un1719-AENTRPower dissipationPower consumptionFieldbus interfaceFieldbus typeEthernet interfaceConnection typeTransfer rate maxStation connectionBus lengthAddressingEthernet addressSupported I/O modulesHART CommunicationInternal busConnection3.0 W3.0 W6Backplane busUse only in connection with the power supply module 1719-PSDCEtherNet/IPRJ-45, via front connectorFull Duplex 10 Mbps; Full duplex 100 Mbps; Half Duplex 100 MbpsDirectly to PCS or PLC or via hubs or switches 100 m ( 328 ft) (CAT 7 cable) SF/UTP in accordance with ISO/IEC 11801IP address assigned via EthernetIP V4 address (ex works standard: 0.0.0.0, auto IP, DHCP)All 1719 remote I/O modulesVia EthernetBackplane busRockwell Automation Publication 1719-TD001G-EN-E - November 2020

1719 Ex I/O ProductsTechnical SpecificationsAttributeIndicators/settingsLED indicatorDirective conformityElectromagnetic compatibilityDirective 2014/30/EUConformityDegree of protectionFieldbus standardEnvironmental testShock resistanceVibration resistanceDamaging gasRelative humidityAmbient conditionsAmbient temperatureStorage temperatureRelative humidityShock resistanceVibration resistance1719-AENTROK LED (Adapter Status):Steady off: No Power - The Adapter has no power.Steady green: Adapter and Rack operational - Adapter and all modules in the rack are operating without fault.Steady red: Fault - At least one module in the rack has detected a fault. Examine the display or the other modules in the rack fortheir status indicator condition.Flashing green/red: Self test - The adapter is booting up or performing power on self tests.NET LED (Network Status):Steady off: No power, no IP address - The adapter has no power or no IP address has been assigned or obtained.Steady green: Connected - The adapter has at least one established connection (either to itself or to an I/O module).Flashing green: No connections - The adapter has an IP address, but there are no established connections (either to itself or an I/Omodule).Flashing red: Connection timeout - One or more of the connections (either to itself or to an I/O module) has timed out.Steady red: Duplicate IP - The adapter has detected that its IP address is already in use.Flashing green/red: Self test - The adapter is booting up or performing power on self testsLINK1 LED (Link Status Port 1):Steady off: No Link - No Link is established on this port.Flashing green: Activity - Indicates activity on this port.LINK2 LED (Link Status Port 2):Steady off: No Link - No Link is established on this port.Flashing green: Activity - Indicates activity on this port.EN 61326-1:2013IEC 60529IEEE 802.3EN 60068-2-14EN 60068-2-27EN 60068-2-6EN 60068-2-42EN 60068-2-56-20. 60 C (-4. 140 F)-25. 85 C (-13. 185 F)95% noncondensingShock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18Frequency range 10.150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration 0.075 mm/1 g; 10 cyclesFrequency range 5.100 Hz; transition frequency: 13.2 Hz amplitude/acceleration 1 mm/0.7 g; 90 minutes at each resonanceDesigned for operation in environmental conditions according to ISA-S71.04-1985, severity level G3Damaging gasMechanical specificationsDegree of protectionIP20 (module), mounted on backplaneConnectionVia backplaneMass approx150 g (5.29 oz)Dimensions approx32 x 100 x 103 mm (1.26 x 3.9 x 4 in)Data for application in connection with Ex-areasDEMKO 16 ATEX 1780XType Examination CertificateGroup, category, type of protectionII 3 G Ex nA IIC T4 GcDirective conformityDirective 2014/34/EUEN 60079-0:2012 A11:2013; General RequirementsEN 60079-15:2010; Potentially explosive atmospheres, protection "n"International approvalsUL approvalIECEx approvalApproved forE106378IECEx UL 16.0141XEx nA IIC T4 GcRockwell Automation Publication 1719-TD001G-EN-E - November 20207

1719 Ex I/O ProductsTechnical SpecificationsAttributeGeneral Information1719-AENTRThe module has to be mounted in appropriate backplanes (1719-A**) in Zone 2, Div 2 or nonhazardous areas. The correspondingdeclaration of conformity has to be observed.For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. For use innonhazardous areas, the modules must be installed in a cabinet; no hazardous area rating is required for the cabinet.EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructionshave to be observed where applicable.For certification information and links to control drawings with complete entity parameter details, see the 1719 CertificationBulletin, publication 1719-CT001.System informationSupplementary information1719 Ex I/O Digital Input1719-IJ Ex I/O Frequency Counter – ConnectionAssociated ApparatusI/O ModuleR1 2.2 kΩR2 10 kΩDir.R2R1IR254 21 Zone 0, 20Div. 18COMR1Zone 2Div. 2Rockwell Automation Publication 1719-TD001G-EN-E - November 2020

1719 Ex I/O Products1719-IBN8B Ex I/O 8 Point Digital Input NAMUR Wide – ConnectionAssociated ApparatusI/O ModuleR1 2.2 kΩR2 10 kΩIVR1IIIR2R1IIR2R1IR287 65 43 21 VIIIVIIVIV1615 1413 COMR1R21211 109 Zone 0, 20Div. 1Zone 2Div. 21719-IBN8 Ex I/O 8 Point Digital Input NAMUR – ConnectionAssociated ApparatusI/O ModuleR1 2.2 kΩR2 10 kΩIVR1IIIR2R1IIR2R1IR287 65 43 21 VIIIVIIVI1615 1413 COMR1R21211 10-V9 Zone 0, 20Div. 1Zone 2Div. 2Technical SpecificationsAttributeSupplyConnectionRated voltage UnPower dissipationPower consumptionWiresTerminal screw torqueWire typeWire size1719-IJ1719-IBN8B1719-IBN8Backplane bus12V DC, only in connection with the power supply 1719-PSDC0.6 W0.6 W1.0 W1.0 W1.5 W1.5 W0.22.0.25 N m (1.95.2.21 lb in)Shielded—0.14.1.5 mm2 (26.16 AWG)0.14.0.5 mm2 (26.20 AWG)Rockwell Automation Publication 1719-TD001G-EN-E - November 20209

1719 Ex I/O ProductsTechnical SpecificationsAttributeInternal busConnectionInterfaceInputNumber of channelsSuitable sensors1719-IJ1719-IBN8B1719-IBN8Backplane busManufacturer-specific bus to standard adapter1Frequency, counter, direction of rotation,NAMUR proximity switches,mechanical contacts8Mechanical contacts, NAMUR proximity switchesChannel I: 1 , 2-; Channel II: 3 , 4-; Channel III: 5 , 6-;Channel IV: 7 , 8-; Channel V: 9 , 10-; Channel VI: 11 ,12-; Channel VII: 13 , 14-; ChannelVIII: 15 , 16-ConnectionChannel I: 1 , 2-; Direction: 4 , 5-Rated valuesSwitching point/switching hysteresisVoltageInternal resistorLine fault ing to EN 60947-5-6 (NAMUR)1.2.2.1 mA / 0.2 mA8.2V1 kΩCan be switched on/off for each channel via the Add-on ProfileMechanical switch with additional resistors (see connection diagram), proximity switches without additional wiring 360 Ω 0.35 mA0.15 kHz in frequency mode—0 40 Hz in frequency counter mode1 ms15 ms—Operating frequencyMinimum pulse durationIndicators/settingsLED indicatorPower LED (P) green: supplyStatus LED (I) red: line faultPower LED (P) green: supplyDiagnostic LED (I) red: module fault, redflashing: Communication error, whiteflashing: requests parameters fromadapterStatus LED (1.8) red: line fault (leadbreakage or short circuit), yellow: signal(per channel)CodingOptional mechanical coding via front socket using coding pins (1719-CP).For more information see 1719 Ex I/O Installation Instructions, publication 1719-IN001.—Directive conformityElectromagnetic compatibilityDirective 2014/30/EUConformityElectromagnetic compatibilityDegree of protectionEnvironmental testShock resistanceVibration resistanceDamaging gasRelative humidityAmbient conditionsAmbient temperatureStorage temperatureRelative humidityShock resistanceVibration resistanceDamaging gasMechanical specificationsDegree of protection10EN 61326-1:2013NE 21IEC 60529EN 60068-2-14EN 60068-2-27EN 60068-2-6EN 60068-2-42EN 60068-2-56-20. 60 C (-4. 140 F)-25. 85 C (-13. 185 F)95% noncondensingShock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18Frequency range 10.150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration 0.075 mm/1 g; 10 cyclesFrequency range 5.100 Hz; transition frequency: 13.2 Hz amplitude/acceleration 1 mm/0.7 g; 90 minutes at each resonanceDesigned for operation in environmental conditions per ISA-S71.04-1985 severity level G3IP20 when mounted on backplaneRockwell Automation Publication 1719-TD001G-EN-E - November 2020

1719 Ex I/O ProductsTechnical SpecificationsAttribute1719-IJConnectionRemovable front connector with screw flange (accessory)Wiring connection (for all terminals): 0.14.1.5 mm² (26.16 AWG)Mass approxDimensions approx90 g (3.17 oz)16 x 100 x 103 mm (0.63 x 3.9 x 4 in)Data for application in connection with Ex-areasPTB 03 ATEX 2042EC-Type Examination CertificateII (1) G [Ex ia] IICGroup, category, type of protectionII (1) D [Ex ia] IIICInputVoltageUo10.5VCurrentIo23.3 mA61.2 mW (linear characteristic)PowerPoStatement of conformityGroup, category, type of protection,temperature classElectrical isolationInput/power supply, internal busDirective conformityDirective 2014/34/EUInternational approvalsUL approvalIECEx approvalApproved for1719-IBN8B130 g (4.59 oz)32 x 100 x 103 mm (1.26 x 3.9 x 4 in)1719-IBN8Removable front connector (accessory)Wiring connection via spring terminal only:0.14.0.5 mm2 (26.16 AWG)90 g (3.17 oz)16 x 100 x 103 mm (0.63 x 3.9 x 4 in)EXA 13 ATEX 0036XII 3(1) G Ex nA [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC14.9V15.7 mA58.2 mW (linear characteristic)PF 08 CERT 1234 XII 3 G Ex nA IIC T4 Gc10V13 mA33 mW (linear characteristic)—Safe electrical isolation according to EN 60079-11, voltage peak value 375VEN 60079-0:2012 A11:2013; General RequirementsEN 60079-11:2012; Equipment protection by intr

Backplane Catalog Numbers 1719-A22, 1719-A8, 1719-A24 Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719 -TB8, 1719-TB8S, 1 719-TB8Sx2, 1719-TB8x 2SA, 1719-TB8x2, 1719-TB6F, 1719 - TB8F, 1719-TB8x2F Connection Cable Catalog Number 1719-CBL Placeholder Module Catalog Number 1719-ARM Separation Plate Catalog Number 1719-SP1 Topic Page

Related Documents:

Texts of Wow Rosh Hashana II 5780 - Congregation Shearith Israel, Atlanta Georgia Wow ׳ג ׳א:׳א תישארב (א) ׃ץרֶָֽאָּהָּ תאֵֵ֥וְּ םִימִַׁ֖שַָּה תאֵֵ֥ םיקִִ֑לֹאֱ ארָָּ֣ Îָּ תישִִׁ֖ארֵ Îְּ(ב) חַורְָּ֣ו ם

Optional Accessories for Rockwell/Rockwell Superficial Type Hardness Testing Machines Order No. Scale 64BAA072 C 64BAA073 N 64BAA086 A 64BAA071 C & N 3/8" 15/32" 7/16" 1/4" Rockwell Type Diamond Indenters Order No. Hardness 64BAA159 HRA81/86 Rockwell Test Block 64BAA160 HRA75/79 Rockwell Test Block

1. ROCKWELL HARDNESS TEST 1. AIM: To determine the Rockwell Hardness of a given test specimen II. APPARATUS: Rockwell Hardness testing machine, Test specimen. III. THEORY: HARDNESS- It is defined as the resistance of a metal to plastic deformation against Indentation, scratching, abrasion of cutting. The hardness of a material by this Rockwell .File Size: 860KB

1. ROCKWELL HARDNESS TESTS Aim: To determine the Rockwell hardness number on B and C scales for a given metallic specimen. Test Setup: Rockwell Hardness Testing Machine. Indenters: i) For Rockwell – B Test: Steel ball indenter of diameter (1/16)th inch. ii) For Rockwell – C Test: Ro

Rockwell Hardness Testing Machine. HR-530 Series. Unique electronic control makes the HR-530 series of hardness testers . capable of Rockwell, Rockwell Superficial, Rockwell testing of plastics (A & B) and Light Force Brinell hardness testing. HR-530 (810-237) Maximum specimen size: Height 250 mm, Depth 150 mm. HR-530L (810-337) Maximum .

HR Series Portable Rockwell/Superficial Rockwell Hardness Tester . HBR Series Brinell & Rockwell Hardness Tester . Caution: 1. Safety goggles must be worn to prevent possible injury. 2. Gloves and the handing handle must be used during the hammer impact test. Attention: Check and confirm to bring the thin screw about 10-20mm up above the .

Metallic materials - Rockwell hardness test - Part 2: Verification and calibration of testing machines and indenters (ISO 6508-2:2015) Matériaux métalliques - Essai de dureté Rockwell - Partie 2: Vérification et étalonnage des machines d'essai et des pénétrateurs (ISO 6508-2:2015) Metallische Werkstoffe - Härteprüfung nach Rockwell - Teil

state’s content standards in ELA and Mathematics –Grades 3 – 8 ELA and 9th and 10th grade literature and American Literature –Grades 3 – 8 Mathematics and Coordinate Algebra, Analytic Geometry and Advanced Algebra Created for exclusive use in Georgia classrooms Piloted with Georgia students Reviewed by Georgia educators