Home Fire Sprinkler Display Guide

1y ago
4 Views
1 Downloads
1.32 MB
23 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Ellie Forte
Transcription

Home Fire Sprinkler Display Guide A C OMP LETE G UIDE T O BUILDIN G AND USIN G A N FPA 1 3D DISP LA Y TO EDUC A T E YOU R C OM M UN ITY US E THIS KIT TO C U STO M IZE T H E H O M E F IRE S P RINKL ER DIS P L A Y TO M ATC H THE RE QUIREM ENT S IN Y O UR J URIS DICT IO N. H o m e F i r e S p r i n k l e r. o r g

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y T A BL E O F CO NT ENT S INTRODUCTION 3 DISPLAY MATERIALS YOU’LL NEED 4 PREFERRED TOOLS LIST 5 SIGNAGE YOU’LL NEED 6 FRAME CONSTRUCTION OVERVIEW 7 DISPLAY COMPONENT PREPARATION 8 SHORT WALL ASSEMBLY 9 LONG WALL ASSEMBLY 10 TOP ASSEMBLY 11 UNIT ASSEMBLY 12 RISER INSTALLATION OVERVIEW 13 RISER INSTALLATION MATERIAL LIST 14-15 13D RISER 3D VIEW - BYPASS METERS 16 TOP VIEW - BYPASS METER 17 FRONT VIEW - BYPASS METER 18 SIDE VIEW - BYPASS METER 19 SIGNAGE INSTALLATION 20 USING YOUR HOME FIRE SPRINKLER DISPLAY H o m e F i r e S p r i n k l e r. o r g 2 21-23 K I T

T H E H F S C H O M E F I R E S P R I N K L E R I NTR ODUC TIO N The Home Fire Sprinkler Display Kit contains instructions for building a portable display that shows the inner workings of an NFPA 13D home fire sprinkler system, various sprinkler options and how to do a flow test. It can be customized to match local system requirements. Refer to page 21 for ideas on using the display to improve home fire sprinkler awareness in your community. The display can be constructed by personnel with moderate to good carpentry skills. Riser installation should only be done by an qualified home fire sprinkler installer. The nonprofit Home Fire Sprinkler Coalition (HFSC) is a 501(c)(3) charitable educational organization and the leading resource for independent, noncommercial information about residential fire sprinklers. HFSC was formed in 1996 in response to the tremendous need to inform the public about the lifesaving value of home fire sprinkler protection. Development of this kit was funded through a grant from State Farm. HFSC thanks Tom Lia and the Northern Illinois Fire Sprinkler Advisory Board for technical assistance. H o m e F i r e S p r i n k l e r. o r g 3 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T DI S PL A Y MATE RIALS Y OU' L L N E E D (1) 1/4" x 4' x 8' plywood (paint white on one side) (6) 2" x 4" x 8' (7) 2" x 6" x 8' (1) 2" x 10" x 8' (4) 2" Medium Duty Caster Wheels H o m e F i r e S p r i n k l e r. o r g (1) box 11/4" Screws (1) box 3" Screws (1) box of sheet metal screws (1) pint of white paint (1) 31/4" x 10" x 5' HVAC Duct Work (optional) (1) Box 11/4" common nails or gun nails (1) paintbrush or paint roller Zip ties or double stick tape for signage attachment (1) paint tray Literature holder 4

T H E H F S C H O M E F I R E S P R I N K L E R PR E FER R ED TO O LS LIST Table saw (preferred) or circular saw Miter saw for angular cuts Jig saw for curved cuts (optional) Impact driver for drywall screws Hammer or nail gun Square Tape measure Hole saw 21/4" 2 saw horses Power drill with screwdriver bit H o m e F i r e S p r i n k l e r. o r g 5 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T S IGNA G E Y OU 'LL N E E D Concealed Pendant Sprinkler Concealed Sidewall Sprinkler Pendant Fire Sprinkler Sidewall Sprinkler 6" Inside Alarm Bell (NFPA 13D Option) Spare Fire Sprinkler Box H o m e F i r e S p r i n k l e r. o r g Water Flow Switch (NFPA 13D Option) Fire Sprinkler Pipe Inspector Test Valve HVAC Duct Work (optional) Backflow Preventer (NFPA 13D Option) Sump Pump 6 Floor Drain Pressure Gauge Control Valve Underground Water Supply Potable Water Supply Water Meter Department Information

T H E H F S C H O M E F I R E S P R I N K L E R F RA ME CONS TRU C TIO N OV ER VIE W Construction of the display frame starts with cutting the individual components to the correct length and angles. The components are then assembled into a Long Wall, Short Wall and the Top. Finally the three pieces are assembled into the display frame. In addition there are flat panels that simulate the home's drywall. These panels can be either square cut or curved cut depending on preference. Optional HVAC duct work can be added, particularly if the mounting of a fire sprinkler alarm is to be demonstrated. H o m e F i r e S p r i n k l e r. o r g 7 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T DI S PL A Y COMP O N E N T PR EPA R ATIO N Construction should begin by cutting out each of the components. It is helpful to layout the components as they are finished. S Q U AR E CUT PIE C E S Cut (4) two-by-fours to 68" Cut (2) two-by-fours to 32" Cut (2) two-by-sixes to 29" Cut (4) two-by-sixes to 68" Cut (1) two-by-six to 441/2" Cut (1) two-by-six to 48" Cut (1) two-by-six to 4" Cut (1) two-by-ten to 441/2" A N G L E CUT PI E C E S Cut (1) two-by-four to 493/4" with 65 and 22 end cuts (see illustration) Cut (1) two-by-six to 463/4" with 22 end cuts (see illustration) Cut (1) two-by-six to 241/2" with 90 and 22 end cuts (see illustration) 2" X 4" 65 Cut (1) two-by-six to 181/4" with 90 and 22 end cuts (see illustration) Cut (1) two-by-six to 111/4" with 90 and 22 end cuts (see illustration) PL YW OOD PA N E L P IE C E S Paint one side of 4' x 8' panel white and let dry. Cut (2) 12" X 441/2" panels Cut (2) 12" X 261/4" panels 2" X 6" 22 22 46 3 4" 22 90 24 1 2" 90 22 11 1 4" Cut (1) 12" X 281/2" panel H o m e F i r e S p r i n k l e r. o r g 22 493 4" 8 90 22 18 1 4"

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T S H O R T WA L L ASSE MBLY 16” on center 1. On saw horses, lay out (4) 68" two-by-four studs 16", 101/2" and 51/2" on center. 2. Attach (1) 32" two-by-four stud to each end using 3" screws. 32” 10½” on center 5½” on center 68” H o m e F i r e S p r i n k l e r. o r g 9

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T L ONG W A L L ASSE MBLY 16” on center 1. On saw horses, layout (4) 68" two-by-six studs 16", 16" and 121/2" on center. 2. Attach (1) 441/2" two-by-six stud to top of studs using 3" screws. 3. Attach (1) 441/2" two-by-ten stud to bottom of studs using 3" screws. Align the studs along the back edge of the two-by-ten. 16” on center 44½” 12½” on center 68” H o m e F i r e S p r i n k l e r. o r g 10

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T 4" T OP A S S E MBLY 46¾" 1. On saw horses, lay out (1) 48" twoby-six stud. 2. Attach (1) 29" two-by-six stud to end using 3" screws. 29" 3. Attach (1) 4" two-by-six stud to end using 3" screws. 24" 18¼" 4. Attach (1) 29" two-by-six stud to connect 4" and 48" studs using 3" screws. 11¼" 5. Attach (1) 141/2" angle cut two-bysix stud to other end of 48" stud using 3" screws. 48" 6. Attach (1) 463/4" angle cut two-bysix stud to connect 141/2" and 29" studs using 3" screws. 7. Slide (1) 241/2" angle cut two-bysix stud and (1) 181/4" angle cut two-by-six stud into position (see illustration) and attach using 3" screws. H o m e F i r e S p r i n k l e r. o r g 11

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y UNI T A S SE MBLY 1. Place Long Wall on sawhorses backside down. 2. Position Short Wall as shown. 3. Attach using 3" screws. 4. Position (1) 493/4" angle cut twoby-four as shown. Steps 1-3 Steps 4-5 Steps 6-7 Step 8 Step 9 Steps 10-11 5. Attach using 3" screws. 6. Position Top as shown. 7. Attach using 3" screws. 8. Attach (4) casters to bottom as shown using 11/4" screws. 9. Attach (5) plywood panels whiteside out as shown using 11/4" screws or nails (optional). 10. Stand Unit upright. 11. Attach HVAC duct work as shown using 11/4" screws (optional). 12. Install smoke alarm. Step 12 H o m e F i r e S p r i n k l e r. o r g 12 K I T

T H E H F S C H O M E F I R E S P R I N K L E R RI S ER I NS TALLATIO N OV ER VIE W The Riser should be installed by an qualified fire sprinkler installer using the following diagrams. The drawings illustrate installing the riser bypassing the water meter. If local ordinances require the meter to be inline, adapt the installation to reflect that. H o m e F i r e S p r i n k l e r. o r g 13 D I S P L A Y K I T

THE HFSC FIRE AND SPRINKLER BURN DEMONSTRATION KIT RI S ER I NS TALLATIO N MA T ER I AL LIST ITEM # QUANTITY 1 (1) Water Meter 2 (1) Domestic Shutoff Valve 3 (1) Double Check Valve Assembly 4 (1) 1" x 0'-4" Blk Sch 40 Nipple 5 (1) 1" D.I. Threaded 90 Degree Elbow 6 (2) 1" x 1'-4" Black Sch. 40 Pipe 7 (2) 1" D.I. Threaded Tee 8 (1) 1" Flow Switch - Optional 9 (2) 1" x 0'-4" Blk Sch 40 Nipple 10 (1) 1" Test and Drain Valve w/Orifice to smallest sprinkler 11 (1) 1" x 1" x 1/2" D.I. Threaded Tee 12 (1) 1/2" x 1/4" D.I. Threaded Bushing 13 (1) 1/4" x 0'-2" Brass Nipple 14 (1) 1/4" 3-Way Valve 15 (1) 1/4" Brass Plug 16 (1) 1/4" Pressure Gauge - Optional 17 (1) 1" x 0'-8" Black Sch. 40 Pipe 18 (1) 1" Steel to CPVC Adapter cont'd H o m e F i r e S p r i n k l e r. o r g 14 DESCRIPTION

THE HFSC FIRE AND SPRINKLER BURN DEMONSTRATION KIT RI S ER I NS TALLATIO N MA TER I A L LIST cont'd H o m e F i r e S p r i n k l e r. o r g 19 (1) 1" x 0'-10" CPVC Pipe 20 (4) 1" CPVC 90 21 (1) 1" x 0'-3" CPVC Pipe 22 (2) 1" x 0'-9" CPVC Pipe 23 (2) 1" CPVC Tee 24 (2) 1" x 0'-3" CPVC Pipe 25 (1) 1" x 1" x 1/2" Sprinkler Head Tee 26 (2) 1" x 0'-6" CPVC Pipe 27 (3) 1" x 1/2" Sprinkler Head 90 28 (2) 1" x 1'-3" CPVC Pipe 29 (1) 1/2" Residential Concealed Sidewall Sprinkler 30 (1) 1/2" Residential Semi-Recessed Sidewall Sprinkler 31 (1) 1/2" Residential Concealed Pendent Sprinkler 32 (1) 1/2" Residential Semi-Recessed Pendent Sprinkler 33 (1) 6" Alarm Bell — Optional 34 (1) Emergency Sprinkler Cabinet with Wrench — Optional 35 (10) 15 1" No-Block CPVC Pipe Hanger

T H E H F S C H O M E F I R E S P R I N K L E R 1 3D R I S ER 3D VIE W B Y PA S S M E TE R H o m e F i r e S p r i n k l e r. o r g 16 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R TOP V I E W B Y PA S S ME TE R H o m e F i r e S p r i n k l e r. o r g 17 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R FR ONT VIE W B Y PA S S ME TE R H o m e F i r e S p r i n k l e r. o r g 18 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R S I DE V I E W B Y PA S S ME TE R H o m e F i r e S p r i n k l e r. o r g 19 D I S P L A Y K I T

T H E H F S C H O M E F I R E S P R I N K L E R D I S P L A Y K I T S I GNA GE INS T A L L A TIO N Place the signs on the appropriate components using zip ties or double stick tape. Local fire departments can create and post their own sign that includes their contact information; Fire Department name and logo, address, phone number, email address, website address, QR Code, etc. H o m e F i r e S p r i n k l e r. o r g 20

T H E H F S C H O M E USING Y OUR HOME FIRE SPR INKL ER DIS P LA Y F I R E S P R I N K L E R D I S P L A Y K I T Now that you’ve assembled your display, it’s time to plan how you’ll use it. The display is portable and it works with a wide range of audiences and many types of events. Here are some examples: C O MM UNIT Y EVENT S State Fair Home Shows and Building Trade Shows Fire Prevention Week Activities Safety Fair Fire Station Open Houses SC HOO L A CT IVIT IES Vocational-technical high school competitions Parent-Teacher conferences Safety Day HO MEBUIL DERS Partner with a homebuilder who offers sprinklers as a way to educate during open houses. Bring the display to area chapter meetings of your local homebuilders’ association to accompany your presentation. M U N ICIP A L A CT IVIT IES Present the display at the Building Department so homebuilders can see it when they bring plans in for approval. Get on the agenda of your Planning and Zoning Boards and bring the display to explain the value of trade ups to encourage sprinklering of new developments. Present the display at your Town/Village Hall. Share the display during Town/Village meetings, elections and other public events. H o m e F i r e S p r i n k l e r. o r g 21

T H E H F S C H O M E USING YOUR HOME FIRE SPRINKLER DISPLAY cont'd F I R E S P R I N K L E R D I S P L A Y K I T U SE T H E DIS P L A Y T O EDUCA T E O T H ER P RO F ES S IO NA L S A T T H EIR O F F ICES A ND M EE TI N G S Insurance agents Real Estate agents Water suppliers O TH ER F IRE DEP A RT M ENT S The portability of this display is one of its best features. If there are other departments near your jurisdiction, offer to share your display when they have public education opportunities in their jurisdictions. E VAL UA T E T H E DIS P L A Y ’ S EF F ECT IVENES S It’s important to know whether public education work is effective and to make changes to improve it. Evaluation is also important (often essential) in order to obtain municipal and grant funding. Pre- and posttests give you a quick answer to how much your audience learned after their exposure to the Display. Using these tests is an easy way to help you determine how well the display meets your educational goals. You can modify these sample test questions based on your audience and the purpose for using the display. Please share your evaluation results with HFSC so we can improve the resources we create and offer to the fire service. SAMP L E P RE- A ND P O S T -T ES T 1. Do you have fire sprinklers installed at home? Yes/No 2. Would you buy a home with fire sprinklers installed? Yes/No/Maybe 3. True or False: Home fire sprinklers are triggered by the smoke alarm. 4. True or False: If fire breaks out, all the fire sprinklers flow water at once. 5. True or False: Home fire sprinklers work automatically, preventing flashover and controlling the heat, smoke and flames until the fire department arrives. M E D IA When you bring the display to a public event, inform your local media ahead of time to encourage coverage of this public safety activity. Let them know that you will be providing a unique hands-on educational resource for the event’s audience. Be sure to mention that the Display makes a great visual backdrop for print and television. H o m e F i r e S p r i n k l e r. o r g 22

T H E H F S C H O M E USING YOUR HOME FIRE SPRINKLER DISPLAY cont'd F I R E S P R I N K L E R D I S P L A Y K I T GE T LO CA L H EL P F O R Y O UR DIS P L A Y If your jurisdiction doesn’t have the budget to purchase the construction materials, reach out to businesses and groups for funding. Be sure to publicly thank your sponsors during events, in local media coverage and you may want to post the names and logos of your sponsors on the side of the display. HE RE A RE S O M E IDEA S : Sprinkler Contractors You’ll need to partner with a sprinkler contractor experienced in NFPA 13D installations to build the Display. They may also be able to help you acquire the sprinkler components by sharing their industry contacts. Lumberyards/Big Box Stores Call the manager at your local retailer and request to meet him/her at the store. Bring the list of tools and construction materials and be prepared to explain what the display is and how it can be used to conduct life safety education in your community. Ask the manager if there are any tools or materials that the store can donate to support this permanent public safety resource. Offer store name and logo recognition in return for their support. Insurance Companies If your local residential property insurers offer a discount for homes protected by fire sprinklers, contact area offices to request a donation and/ or participation in your educational events. (Note: State Farm is HFSC’s sponsor for this display but you can work with any home insurer.) H o m e F i r e S p r i n k l e r. o r g 23

fire sprinkler awareness in your community. The display can be constructed by personnel with moderate to good carpentry skills. Riser installation should only be done by an qualified home fire sprinkler installer. The nonprofit Home Fire Sprinkler Coalition (HFSC) is a 501(c)(3) charitable educational organization and the leading resource for

Related Documents:

Antifreeze Solutions in Home Fire Sprinkler Systems 100138.04.000 May 28, 2010 CODE CONSULTANTS, INC. Page 1 Executive Summary NFPA 13, Standard for the Installation of Sprinkler Systems, has included guidance on the use of antifreeze solutions in fire sprinkler systems since the 1940 edition.1 Antifreeze solutions may be used in fire sprinkler systems where the piping system, or File Size: 942KBPage Count: 100Explore furtherNFPA 13: Standard for the Installation of Sprinkler .archive.orgNFPA 13: Standard for the Installation of Sprinkler Systemswww.nfpa.orgNFPA 13-2010: Installation of Sprinkler Systems (The .rtmconsultants.comNFPA 13 Standard For The Installation Of Sprinkler Systems .nfpa13.engineeringdesignresources. NFPA 13-2019: Installation of Sprinkler Systems Standard .blog.ansi.orgRecommended to you b

CPVC Pipe 20mm CPVC Fire Sprinkler Pipe [4.5M Length] 3/4" 555 15 25mm CPVC Fire Sprinkler Pipe [4.5M Length] 1" 448 8 32mm CPVC Fire Sprinkler Pipe [4.5M Length] 1 1/4" 300 6 40mm CPVC Fire Sprinkler Pipe [4.5M Length] 1 1/2" 250 5 50mm CPVC Fire Sprinkler Pipe [4.5M Length] 2" 165 3 65mm CPVC Fire Sprinkler Pipe [4.5M Length] 2 1/2 .

threads only, while taking care not to allow a build-up of compound in the sprinkler orifice. D. Use ONLY sprinkler wrench 13635W/B (shown in Figure 1) for installing ESFR Sprinkler VK510! With the sprinkler contained in the protective cap, install the sprinkler onto the piping by applying the sprinkler wrench to the sprinkler

1. An automatic sprinkler system for a Small House is an improvised sprinkler system which mainly comprises sprinkler heads, sprinkler pipes, a set of sprinkler control valves, a sprinkler pump and a sprinkler tank. 2. For the design and main components of an automatic sprinkler system, reference shall be made to the attached Schematic Drawing for

sprinkler system freezing. The steps to take depend on the type of fire sprinkler system you have installed. The Two Types of Fire Sprinklers Reducing the risk of your fire sprinkler system freezing depends on the type of fire sprinkler system installed. The type that is found inside many fraternity houses is a wet system. In a wet system, the .

performance from your sprinkler system. This has benefits for firefighting and is likely to lead to better fire outcomes. Figure 2 - Typical sprinkler system components Full or partial sprinkler system temporarily disabled Sprinkler systems are usually disabled for maintenance, or during non-sprinkler-related construction in the building.

Central Sprinkler Corporation GEM Sprinkler Company Globe Fire Sprinkler Corporation Reliable Automatic Sprinkler Co. Star Sprinkler Corporation Victaulic Fire Safety Company,LLC The Viking Group ASSOCIATE MEMBER API Fire Protection Group t an r G y et af S and n io t n e v e r P e ir F y b ed t por up s is am r og pr his T

Andreas Wagner { Integrated Electricity Spot and Forward Model 16/25. MotivationFrameworkModel and ResultsConclusions Volatility of supply-functional This observation motivates the following volatility structure (as in Boerger et al. [2009]) Volatility structure ( ;t) e (t ) 1; 2(t) ; where 1 is the (additional) short-term volatility, is a positive constant controlling the in .