A-8 Sump And Riser Calculations For SCA Final Cover Design - Lake Cleanup

10m ago
7 Views
1 Downloads
602.38 KB
14 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Rosa Marty
Transcription

ONONDAGA LAKE SCA FINAL COVER DESIGN REPORT A-8 Sump and Riser Calculations for SCA Final Cover Design PARSONS P:\Honeywell -SYR\448533 SCA Final Cover Design\09 Reports\9.10 2016 Final Design Submittal\Final Submittal\SCA Final Design Report 05 2016.docx May 2016

2 Page Written by: Client: Ray Wu Honeywell Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: SUMP AND RISER CALCULATIONS FOR SCA FINAL COVER DESIGN INTRODUCTION This package was prepared in support of the final cover design of the Sediment Consolidation Area (SCA) for the Onondaga Lake Bottom Site, located on Wastebed 13 (WB-13). This package presents an analysis of the existing liquid management system (LMS) sumps and risers in the SCA, which collect the liquids from dredged material dewatering and rainfall/infiltration and pump them out of the SCA. The purpose of the analysis presented in this package is to estimate the liquid storage volume and typical pump off and on times for the sump pumps after placement of the final cover. METHODOLOGY The sump and riser calculations in this package include estimating the LMS sump pump size and storage volume after placement of the final cover. Sump Volume and Pump Sizing: The storage volume of the sump is calculated as the volume between the pump off level and the top of the low permeability soil liner outside the sump area. This volume is a combination of open area inside the riser pipes and pore volume of areas outside the risers that are filled with gravel. Pump on time is calculated by dividing the storage volume by the selected pumping rate minus the design inflow rate. Pump off time is calculated by dividing the storage volume by the inflow rate to the sump. INPUT PROPERTIES As shown in Figure 1, the constructed sumps are each 5 ft in depth and contain four risers. The bottom of each sump has dimensions of approximately 55 ft long by 40 ft wide. Each riser is connected to other lateral collection pipes to collect flow. The existing risers are 5 ft diameter, high density polyethylene (HDPE) manholes with a standard dimension ratio (SDR) of 26. As shown in Figure 2, the risers are located on a 6-inch concrete pad (for anti-flotation purposes), GA140560/SCA Final Cover Sump and Riser Package 03

3 Page Written by: Client: Ray Wu Honeywell Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: with a 2-inch HDPE flat stock riser base and a 6-inch working space between the bottom of the riser and the pump bottom. The existing pumps were designed for the current operational conditions (i.e., each pump is capable of pumping up to approximately 1,600 gallons per minute of leachate flow). These pumps are not considered appropriate for conditions after placement of the final cover with minimal leachate flow, and therefore a lower capacity piston pump can be used. The calculated liquid inflow rate for the entire SCA after final cover placement was 0.1 gal/min, as presented in the calculation package titled “Evaluation of Hydraulic Performance for SCA Final Cover Design”. It is noted that this inflow rate has been computed for conditions after placement of the geomembrane in the final cover system and does not consider leachate flow during final cover placement. Based on information provided by site operations, it is expected that the leachate flows during final cover placement will be relatively minimal and can be handled using the existing pumps or additional temporary pumps, as needed. Liquid inflow due to continued consolidation of the geotextile tubes is expected to be minimal based on observations during the winter shutdown periods in 2012/2013, 2013/2014, and 2014/2015 (i.e., precipitation generally accounted for the liquid flows recorded over the shutdown periods) and was therefore not considered herein. However, leachate flows during final cover installation will be monitored and, if necessary, the inflow rates assumed and calculations performed herein will be modified. It is further noted that although each sump was constructed with four risers, two risers at each sump were cutoff and decommissioned during the 2015 construction season. It was assumed that only one of the remaining two risers per sump would have an operating pump after the final cover has been installed. As presented in Figure 3, the post-settlement as-built liner contours indicate that the total water infiltration will be split between the western sump area and the eastern sump area. Based on the relative areas, it appears that approximately 60% of the infiltration will drain to the western sump area and approximately 40% to the eastern sump area. Therefore, the volume and pump off and on time calculations use a target liquid inflow rate of 0.06 gal/min for the western sump area and 0.04 gal/min for the eastern sump area (i.e., 60%/40% split of the 0.10 gallons per minute total inflow rate described above). CALCULATIONS The calculation worksheets for the sump volume and pump design are provided in Attachment 1. GA140560/SCA Final Cover Sump and Riser Package 03

4 Page Written by: Client: Honeywell Ray Wu Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: RESULTS OF ANALYSIS The results of the sump volume and pump sizing calculations are summarized in Table 1. For the conditions after placement of the final cover described previously (i.e., inflow of 0.06 gal/min to the western sump, 0.04 gal/min to the eastern sump, and a pump on level of 6 inches above the automatic off elevation of the pump), the configuration results in a fill time of approximately 56 days for the western sump and 85 days for the eastern sump. After final cover placement, if a pumping rate of 2 gal/min is selected, the western and eastern sumps will have a pump on time of approximately 42 and 41 hours, respectively. Different pump capacities and on/off times may be used as appropriate based on actual field conditions and recommended pump cycle times from the pump manufacturer. GA140560/SCA Final Cover Sump and Riser Package 03

5 Page Written by: Client: Honeywell Ray Wu Project: Date: Reviewed by: 09/11/2015 Onondaga Lake SCA Final Cover Design Tables GA140560/SCA Final Cover Sump and Riser Package Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: 03

6 Page Written by: Client: Honeywell Ray Wu Project: Date: Reviewed by: 09/11/2015 Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: Table 1: Pump Design Summary QDESIGN (gal/min) Pump Off Time [2] (days) Pump Rate (gal/min) Pump On Time (hr) West Sump 0.06 56 2 42 East Sump 0.04 85 2 41 Notes: 1. An automatic on level of 6 inches (0.5 ft) was assumed to minimize the water level within the sump. 2. This is the time taken for the liquid level to go from the minimum to maximum level within the sump area. 3. Different pump capacities and on/off times may be used as appropriate based on actual field conditions and recommended pump cycle times from the pump manufacturer. 4. The pump off and pump on times are calculated in Attachment 1. GA140560/SCA Final Cover Sump and Riser Package 03

7 Page Written by: Client: Honeywell Ray Wu Project: Date: Reviewed by: 09/11/2015 Onondaga Lake SCA Final Cover Design Figures GA140560/SCA Final Cover Sump and Riser Package Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: 03

8 Page Written by: Client: Honeywell Ray Wu Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: Figure 1: Sump Design Note: 1. Actual as-built dimensions and elevations of the sumps may vary slightly from the values shown herein. GA140560/SCA Final Cover Sump and Riser Package 03

9 Page Written by: Client: Date: Ray Wu Honeywell Project: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Primary Pump 13 of Date: 09/11/2015 Task No.: GD5497 03 Backup Pump Riser Pipe Geosynthetics Maximum Liquid Level Low Permeability Soil Minimum Liquid Level Automatic On[1] Gravel SOLW in WB-13 2 in Riser Base 5 ft Automatic Off[1] 6 in 5 ft 6 in pad Figure 2: Conceptual View of Sump Area (not to scale) Notes: 1. An automatic off height of 6 inches is sufficient for several commercially available piston pumps. An automatic on height of 6 inches is assumed, in order to minimize water buildup. 2. The side slopes of the sump area are 2.5 horizontal:1 vertical (2.5H:1V). 3. The width of the as-built sump bottom is approximately 40 ft, and the length of the as-built sump bottom is approximately 55 ft. 4. The geosynthetics near the sump include a geotextile, geomembrane, and geosynthetic clay liner. It is noted that the thickness of the geosynthetics is negligible for purposes of the sump and riser calculations. GA140560/SCA Final Cover Sump and Riser Package

10 Page Written by: Client: Ray Wu Honeywell Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: Sump Locations Eastern Drainage Area 20 acres Western Drainage Area 29 acres Figure 3: Estimated Post-Settlement Contour Map of the Top of Clay Liner (30 years after placement of the final cover) Notes: 1. The post-settlement contour map shown here is based on estimated elevations from settlement calculations, as described in the calculation package titled “Settlement Analyses for the SCA Final Cover Design.” 2. Approximately 60% of the SCA area will drain to the western sump area, and approximately 40% of the SCA area will drain to the eastern sump area. GA140560/SCA Final Cover Sump and Riser Package 03

11 Page Written by: Client: Honeywell Date: Ray Wu Project: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Attachment 1: Calculation Spreadsheets GA140560/SCA Final Cover Sump and Riser Package Date: GD5497 13 of 09/11/2015 Task No.: 03

12 Page Written by: Client: Honeywell Date: Ray Wu Project: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Date: Sowmya Bulusu / Jay Beech Project/ Proposal No.: GD5497 09/11/2015 Task No.: Sump Volume Calculations: Input Parameters[1,2] Gravel Porosity n West Sump East Sump 0.4 0.4 Distance between sump bottom and Automatic Off (ft) Length between Automatic Off and On L (ft) 1.67 1.67 0.50 0.50 Target Inflow Rate QIN (gal/min) 0.06 0.04 Pumping rate QPUMP (gal/min) 2 2 Riser Nominal Diameter DR (ft) 5 5 Length of Sump at Maximum Liquid Level a (ft) 65.83 65.83 Length of Sump at Minimum Liquid Level b (ft) 63.33 63.33 Width of Sump at Maximum Liquid Level c (ft) 50.83 50.83 Width of Sump at Minimum Liquid Level d (ft) 48.33 48.33 Volume Calculations[3,4] Vol. of Sump from W MIN to W MAX (gal) VPY RAMID VPY RAMID (gal) (L /6)*(ad bc 2ac 2bd )/0.134 VPY RAMID (gal) 11950.7 11950.7 Storage Vol. inside Riser VRISER (gal) ((π/4*DR *L )/.134) * 2 risers 2 VRISER (gal) 146.5 146.5 Total Storage Vol. (gal) VSTORAGE (VPY RAMID -VRISER )*n VRISER Total Storage Vol. (gal) VSTORAGE 4868.2 4868.2 Pump On and Pump Off Time Calculations[5] Pump off time (hr) VSTORAGE/QIN Pump off time (hr) Pump off time (days) 1352.3 2028.4 56.3 84.5 Pump on time (hr) VSTORAGE/(QPUMP-QIN ) Pump on time (hr) GA140560/SCA Final Cover Sump and Riser Package 41.8 41.4 13 of 03

13 Page Written by: Client: Ray Wu Honeywell Project: Date: 09/11/2015 Reviewed by: Onondaga Lake SCA Final Cover Design Sowmya Bulusu / Jay Beech Project/ Proposal No.: Date: GD5497 13 of 09/11/2015 Task No.: Notes: 1. The distance between the sump bottom and the automatic off elevation is considered to be 20 inches (i.e., 6-inch concrete pad, 2-inch riser base, 6-inch distance working area beneath pump and 6-inch automatic off elevation). The distance between the automatic off elevation (i.e., minimum liquid level) and the automatic on elevation (i.e., maximum liquid level) is assumed to be 6 inches. 2. The lengths and widths of sump at minimum and maximum liquid levels are calculated assuming a 2.5H:1V side slope, an as-built sump bottom length of 55 ft, and an as-built sump bottom width of 40 ft (based on Figure 2). The calculated lengths and widths are as follows: a 55 ft 2*2.5*(1.667 0.50 ft) 65.83 ft b 55 ft 2*2.5*(1.667 ft) 63.33 ft c 40 ft 2*2.5*(1.667 0.50 ft) 50.83 ft d 40 ft 2*2.5*(1.667 ft) 48.33 ft 3. 4. 5. Two risers at each sump were cutoff and decommissioned during the 2015 construction season. The sump volume is calculated based on a truncated rectangular pyramid. The riser pipe volume is calculated based on a cylindrical pipe. The volume occupied by the riser pipe wall thickness is small relative to the overall storage volume and is ignored. Pump off time represents the amount of time necessary for the sump area to fill from the minimum water level to the maximum water level. The pump on time represents the amount of time that the pump runs to remove the liquid. GA140560/SCA Final Cover Sump and Riser Package 03

Sump and Riser Calculations for SCA Final Cover Design . Title: Microsoft Word - SCA Cover - Sump and Riser_05_04_16 Author: KYamamoto Created Date:

Related Documents:

ANALYSIS AND DESIGN OF SUMP With respect to the plan of the sump, structure is made with Loads which are acting on the sump are Dead Load, Hydraulic Load and Soil Load. AutoCAD Diagram: The following AutoCAD diagram shows the overview of Sump in the below figure. Fig.2. Overview of Sump SUMP DIMENSIONS Length 4 m Breadth 3 m Height 3 m

flow straighteners. In sump -2 at the testing time surface vortices and air entering at low intensity as compared to sump-1.due to this reason, In sump-3 some design changes, Pump Sump-3 are done according to HI (Hydraulic Institute) standard or ASME Criteria for a pump sump design. The computationa investigations were performed

General design rules for riser necks used in iron castings; a. general riser b. side riser for plates c. top round riser Risers and Riser Design . Mech 423 #2 2 Figure 5.10 (a) Castings with blind feeders, F2 is correctly vented but has mixed results on sections S3 . metal velocity and turbulence

S4 / S6 Riser Kits Installation 9329-66144-00 REV A 1 S4/S6 Riser Kit Installation This document provides instructions for inst alling Riser Kits in an Avid S4 or S6 c ontrol surface. Riser Ki ts raise modules whe n a better viewing and interaction angle is desi red. Riser Kits for S4 and S6 include 1- bay and 2-bay kits.

Clearwater sump having different shapes on the plan is considered for the design of 300kl capacity of treated water. A Pump house is mounted on top of the sump whose roof slab is designed as supported over beam and column frame arrangement. RCC columns are provided inside the sump to support the roof slab of the sump and pump house.

A battery backup pump is a secondary sump pump that runs on DC voltage. It is intended as a backup pump that would only turn on in an emergency, such as a power outage or primary pump failure, because usage will deplete the battery Water-powered Backup Sump Pump A water powered backup is a secondary sump pump that is powered by a municipal

The drain or sump pump discharge shall be into the sanitary or storm drainage system through an indirect waste connection. In elevators provided with Firefighters' Emergency Operation, a drain or sump pump shall be provided. The sump pump/drain shall have the capacity to remove a minimum of 3,000 gal/h per elevator (50 GPM). Oil .

Center for Japanese Language, Waseda University Japanese Language Program Admission Guide *This program is not a preparatory course for students intending to enroll in Undergraduate or Graduate programs in Japanese universities. April admission/September admission Center for Japanese Language, Waseda University Center for Japanese Language, Waseda University Address: 1-7-14, Nishi-waseda .