C21-2Electric Heaters for Navaland Marine Applications

IntroductionThis catalog represents over 80 years of experience in electric heating. Shortlyafter our founding in 1929, heaters for Naval and Marine use were added to ourproduct line. With over 400,000 square feet devoted exclusively to designing andmanufacturing electric heaters, a separate facility dedicated to electronic controls, astaff of experienced engineers and local sales support, we are able to satisfy anymarine application – large or small, custom designed or off-the-shelf.Table of ContentsShipbuilding Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Fluid Heating Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Vent Duct Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3MIL-SPEC Duct Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5Sample Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Space Heating Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-9Component Heating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

Shipbuilding ApplicationsShipyards and Shipbuilding Programs Using INDEECO HeatersShipyardsAustal USABAE Systems, San DiegoBAE Systems, Southeast ShipyardsBath Iron Works (General Dynamics)Bender ShipbuildingCoastal Dry DockCoastal MarineColonnas ShipyardsContinental MaritimeDerecktorDetyensEarl IndustriesElectric Boat (General Dynamics)Ingalls (Northrup Grumman)IntermarineLong Beach Naval ShipyardLyon ShipyardMarinette MarineProgramsAlaska State FerryAOE — Fast Combat Support ShipCG — Guided Missile CruiserCVN — Convection Heaters, Various SpacesDDG — Guided Missile DestroyerDDX — Navy Destroyer ProgramDREDGE (US Army)FFG — Guided Missile FrigateFishing BoatsIcebreakerLCAC — Landing Craft Air CushionLCS — Littroral Combat ShipsLCU — Landing Craft Utility (Army)LHA6 — Amphibious Assault ShipLHD — Amphibious Transport DockLHD-8 — Amphibious Transport DockLPD — Amphibious Assault ShipLSD — Landing Ship DockLST — Landing Ship TankMayport Naval ShipyardMetro Machine Corp.Marine Hydraulics (MHI)National Shipbuilding Co. (NASSCO)Newport News ShipyardNorfolk Naval ShipyardNorth American ShipbuildingNorthrop Grumman Ship SystemsAvondale OperationNorthwest MarinePhiladelphia Naval ShipyardPortsmouth Naval ShipyardPuget Sound Naval ShipyardSan Diego Naval StationTacoma BoatTampa ShipyardsTodd ShipyardTrinity MarineVT Halter MarineLT1 — US Army TowboatsMCM — Mine Counter Measure ShipMHC — Mine Hunter, CoastalMine Hunter, SweeperMSC Ships, VariousOffshore Drilling PlatformsPGF-2 — Guided Missile Frigate (TaiwaneseNavy)River Gambling BoatsSA’AR-5 CORVETTES (Israeli Navy)SSN-21 Seawolf Nuclear Attack SubmarineSubmarines (688 and Virginia Class)TAGS — Surveying ShipTAO — Fleet OilerTugboats — WLM/WLBTWR — Torpedo Weapons RetrieverT-AGOS — Oceanographic Survey ShipUSCG — DeepwaterWHEC-FRAM-USCG Coast Guard CutterYRM & YRB — Berthing Barges1

Fluid Heating EquipmentCirculation Heaters and ControlsWith complete in-house facilities to manufacture pressure vessels, immersion heaters,sheet metal enclosures and electronic controls,INDEECO offers a complete line of heatercontrol packages for water, oil, and other fluids.Typical applications for INDEECO circulationheaters include heating lube, hydraulic, andheavy fuel oils. Circulation heaters are alsoused to provide supplementary heat for freshwater makers and jacket heaters for radardomes. Our welding shop is ASME qualified toweld per Section IX. INDEECO ASME weldingstamps: “U” (Section VIII, Division I). INDEECOcirculation heaters and remote control panelswith SCR’s have been shock tested per MIL-S901 and vibration tested per MIL-STD-167-1.From small pipe thread heaters for galley use to480 KW or larger flanged heaters for vapor compression water makers, our immersion heaterscan handle virtually any marine job. Special lubeoil heaters with hermetic seals and liquid-proofoutlet boxes are qualified per MIL-H-24299.Water purification heaters are qualified perMIL-H-22577 and MIL-S-16196D for vapor compression distillers. Hydraulic fluid heaters havebeen shock tested per MIL-S-901 and vibrationtested per MIL-STD-167-1. Pipe thread immersion heaters are listed by UL (UnderwritersLaboratories) per Standard 499, File #E23541and by CSA (Canadian Standard Association)per Standard Class 2871, Report #LR11895-35.Copper, stainless steel, Incoloy, Copper/Nickeland Monel sheathed heaters are available,along with liquid-proof and explosion-proof terminal boxes and hermetic seals.Flanged Immersion HeaterCirculationHeater2Immersion HeatersRemote Control Panelwith SCR’sFlanged Immersion Heater

Vent Duct HeatersDuct HeatersMarine Duct HeatersAs long time leaders in this field, we fabricateall essential components right through tofinal assembly and testing. We make our ownfinned tubular elements, weld and fabricate thesheet metal frames and manufacture electroniccontrols.Used on commercial and non-combat Navalvessels, these heaters are available with eitherside or bottom mounted terminal boxes housing control and safety components. They meetU.S. Coast Guard requirements per 46CFR111.87, are listed by UL per Standard 1996,File #E23192, and are ABS (American Bureauof Shipping) approved. Captive nuts may befurnished in factory-provided mounting holesto simplify installation. Built-in thermal cutouts,magnetic contactors, airflow switch, and controltransformer are standard. Our wide range ofoptional controls includes pilot lights, SCR’s, andelectronic step controls.MIL-SPEC Duct HeatersFully qualified per MIL-H-22594A and MIL-PRF22594B (all sizes), these heaters are madewith Monel 400 finned tubular elements withhermetic terminal end seals and stainless steelframes, qualifying them for standard or nonmagnetic installations and making them imperviousto salt water corrosion. They have been shocktested per MIL-S-901 and vibration tested perMIL-STD-167-1. Where required, they may bequalified for low magnetic permeability per MILI-17214. See heater listing on pages 4-5.Marine Duct Heater withSide Mount Terminal BoxMIL-SPECDuct Heater3

MIL-SPEC Duct Heaters4HeaterSize gInside FrameDimensions (Inches)KW3 666666666666666888886888888888Weight(Lbs)APL 017110182100431017210176100651005210066

MIL-SPEC Duct HeatersHeaterSize 183Inside FrameDimensions (Inches)3 8Weight(Lbs)APL 10148(1)(1)1014907A090021(1)1015107A020024(1)APL Number not yet assigned. Contact INDEECO for National Contract Number.5

Sample SpecificationMarine Duct Heater Sample SpecificationA specification to assure that the design and construction meet U.S. Coast Guard requirements canbe prepared for electric duct heaters by copying the appropriate numbered sections below. A checkbox has been supplied so that you may mark those sections which you require. Material which is partof the basic specification has already been checked. 1. Supply electric duct heaters of the finned tubular type. All exposed metal frame and elementsurfaces and/or electrical enclosures shall be Type 304 stainless steel. Galvanized or aluminized coatings are acceptable only if applied after equipment is fabricated. The heatersshall be:oFor flange mounting to external duct flanges.oFor slip-in mounting through side of duct. 2. Heaters shall be ABS approved, UL Listed to Standard 1996 and shall be in compliance withCFR Title 46 and all referenced Standards, including NEC, UL and IEEE-45. Heaters shall bemanufactured by INDEECO. 3. Heaters shall be rated for the KW, voltage, phase and number of heating stages indicated inthe schedule. Heaters shall be specifically designed for the airflow direction and terminal boxoverhang indicated in the schedule.4. Heaters shall be furnished with the Control Option indicated below:o Basic Option “G”To include thermal cutouts,airflow switch, disconnectingmagnetic contactors, fusesper NEC, fused and groundedcontrol circuit transformer,and disconnect switch withmechanical door interlock.Solid State ProportionalOption “K”To include thermal cutouts,airflow switch, solid state powercontroller/step controller, fusesper NEC, disconnect switch withmechanical door interlock and forheaters which exceed 277 volts,a fused and grounded controlcircuit transformer.oThe following shall be supplied withOption K:o Tamperproof room thermostat(standard).o Duct thermostat with remotesetpoint adjuster.o PE Transducer.5. The following additional special construction features shall be supplied:ooWatertight construction.Captive nuts for mountingheaters to duct work.(Flanged heaters only)ooInsulated terminal box.Bottom terminal box.ooZero overhang terminal box.(Heater frame will be extendedto match the terminal box width.Flanged heaters only).NEMA 3R construction.6. The heaters shall be supplied with the following control circuit special features:oo6Electronic step controller(Option G) Multistageheaters only.All controls to be mountedin remote panelboard.oooPilot lights.Delete transformer andcontactors.Fusing for heaters ratedunder 48 amps.oooFan relay in place of airflow switch.Delete transformer.Pilot switch.

Space Heating EquipmentTRIAD Washdown/CorrosionResistant Unit HeaterType “T” ConvectorNavy Sloped Top ConvectorsTRIAD Washdown/Corrosion ResistantUnit HeatersMIL-Spec ConvectorsThis stainless steel construction with non-metallicNEMA 4X enclosure can be hosed down forcleaning in dirty, wet, and corrosive marineapplications. TRIAD unit heaters are UL listed,File #E97759(N), meet U.S. Coast Guardrequirements, and are ABS approved. See catalog C23/90 for details.Two types are available. The new Navysloped top design, per NAVSEA document#59512-BS-MMA-010 includes both a built-inmanual reset over temperature cutout and athermostat. The Type T (turrett) construction per MIL-H-22663 has no built-in controls.Heaters are also available with a completebuilt-in control package to eliminate the needfor remote contactors and transformers.Navy Sloped Top ConvectorsReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 15CE 203.504.506.00Volts/PhaseDimensionsL” x H” x 440/3440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 748 x 21 x 179655252-179656252-179657252-179658Navy Sloped Top Convectors with ControlsReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 153.504.50Volts/PhaseDimensionsL” x H” x 440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 665252-179666252-1796677

Space Heating EquipmentType “T” Turret 1440/1440/1115/1440/1440/1DimensionsL” x H” x D”21.875 x 6.875 x 5.87521.875 x 6.875 x 5.87521.875 x 6.875 x 5.87521.875 x 6.875 x 5.87521.875 x 6.875 x 5.87521.875 x 6.875 x 21P18948-4252-X21P18948-8Commercial Marine Sloped Top ConvectorsINDEECO Commercial Marine Sloped Top Convectors are available with the same electrical ratingsand physical dimensions as their Mil-Spec counterparts and may also be provided with built-in controlsto allow for a single point electrical connection.Standard built-in controls include an adjustable thermostat with a range of 40 -100o F, a manual resetthermal cutout, main power terminal blocks and 440/24 control circuit transformer with fusing asrequired. Transformers are not required for 120 volts units (sizes CE 3/4 and CE 1-1/2) because alldevices are load carrying.The cabinet is manufactured of 316 series stainless steel and features a watertight control enclosure.The heating elements are made of 304 series stainless steel and have either Hermetic or RTV seals toprohibit the entrance of moisture. The use of stainless steel throughout guarantees rugged constructionand long life.Commercial Marine Sloped Top Convector SST Hermetically Sealed Elements8ReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 15CE 203.504.506.00Volts/PhaseDimensionsL” x H” x 440/3440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 748 x 21 x 179675252-179676252-179677252-179678

Component Heating ElementsCommercial Marine Sloped Top ConvectorSST Hermetically Sealed Elements with ControlsReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 153.504.50Volts/PhaseDimensionsL” x H” x 440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 685252-179686252-179687Commercial Marine Sloped Top Convector SST RTV Sealed ElementsReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 15CE 203.504.506.00Volts/PhaseDimensionsL” x H” x 440/3440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 748 x 21 x 179695252-179696252-179697252-179698Commercial Marine Sloped Top Convector withSST RTV Hermetically Sealed Elements with ControlsReferenceSizeKWCE 3/4CE 1-1/2CE 2-1/2CE 3-1/2CE 5CE 6CE 8.25.50.751.001.502.002.50CE 12CE 153.504.50Volts/PhaseDimensionsL” x H” x 440/3440/315 x 21 x 715 x 21 x 724 x 21 x 724 x 21 x 724 x 21 x 736 x 21 x 736 x 21 x 736 x 21 x 748 x 21 x 705252-179706252-1797079

Component Heating ElementsMIL-SPEC Finned Tubular ElementsThese hermetically sealed elements have Monel sheath and fins, continuously brazed together, tomeet the most rigorous Navy requirements. Qualified to MIL-H-22594A and MIL-PRF-22594B theyare available in straight or bent configurations.MIL-SPEC Finned Tubular ElementTubular/Finned Tubular ElementsTubular and finned tubular elements for general use are available to meet your specifications.UL recognized per Standard 1030, File #E78533. Options include many different terminations, insulators, seals, bending configurations and mounting assemblies.Two-Pass Finned Tubular ElementCustom Formed Tubular ElementINDUSTRIAL ENGINEERING & EQUIPMENT CO.425 HANLEY INDUSTRIAL COURTST. LOUIS, MO 63144314-644-4300Fax: 314-644-5332www.indeeco.com21-1100-80-21.5M0211

Heater From small pipe thread heaters for galley use to 480 KW or larger flanged heaters for vapor com-pression water makers, our immersion heaters can handle virtually any marine job. Special lube oil heaters with hermetic seals and liquid-proof outlet boxes are qualified per

Related Documents:

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

Safe area fan heaters, industrial convectors, in line heaters. Vented and unvented storage water heaters, vat heaters. Industrial, domestic, baptistry and portable immersion heaters. Externally adjustable flameproof immersion heaters, thermostats and radiators. Drum heaters silicone rubber an

However, electric furnaces can accommodate central cooling easier than zonal electric heating, because the air conditioner can share the furnace’s ducts. Electric resistance heat can be provided by electric baseboard heaters, electric wall heaters, electric radiant heat, electric space heaters, electric f

Nailor Industries Inc. Electric Duct Heaters have been tested and approved to the following standards by ETL Testing Laboratories Inc., Courtland, N.Y. (Listing Report No. 554250. Category: Duct Heaters 327 U.S.A. and 328 Canada) ANSI/UL Standard 1996, "Electric Duct Heaters" CSA Standard C22.2 No. 155-M1986. "Electric Duct Heaters"

Explosion-proof Unit Heaters Comparison Chart 6-7 Ultra-Safe EXP Explosion-proof Unit Heaters (233) 8-13 Compact Explosion-proof Unit Heaters (236) 14-16 Convector (254) 17-24 Fan Forced Heaters Comparison Chart 25 TRIAD Washdown/Corrosion Resistant Unit Heaters (234) 26-29 Industrial Unit Heater IUH Series (238) 30-32 Unit Heater UHIR Series .

Explosion-proof Unit Heaters Comparison Chart 6-7 Ultra-Safe EXP Explosion-proof Unit Heaters (233) 8-14 Compact Explosion-proof Unit Heaters (236) 15-17 Convector (254) 18-25 Fan Forced Heaters Comparison Chart 26 TRIAD Washdown/Corrosion Resistant Unit Heaters (234) 27-30 Industrial Unit Heater IUH Series (238) 31-33 Unit Heater UHIR Series .

Types of Portable Propane Radiant Heaters Currently, there are three types of portable propane radiant heaters available to consumers: (1) single burner radiant heaters, (2) radiant heaters that also function as cookers, and (3) radiant heaters equipped with an Oxygen Depletion Sensor (ODS). The singl

Conduct an API-653 inspection of your tank every five years as recommended by TFI (The Fertilizer Institute) WHAT IS THE API 650 SPECIFICATION API - AMERICAN PETROLEUM INSTITUTE Worldwide Standard for Above Ground Storage Tank Design and Construction Provides requirements for calculations of shell plate thickness, man-way and nozzle design Provides procedures for shell, roof and floor .